Loading...
HomeMy WebLinkAboutApplication-Permit.pdfGarfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81601 ~ Phone: (970)945~8212 Fax: {970)384~3470 Project Address Parcel No. Subdivision Section Township Range 207 Willow Creek TR Battlement Mesa, CO 81635-240707403013 WILLOW CREEK VILLAGE SEC. 7 7 95 Owner Information Elliott & Whitney Gross Address 71 Bryan LP Parachute CO 81635 Phone Cell 970-285-9068 Contractor(s ) Phone Primary Contractor Required Inspections: Elliott Gross (970)285-9068 Ves Proposed Construction I Details 8/17/09 Julie called owner with bal $1268.15 & ready for Pu. FEES DUE Fee Plan Check Fee Residential Building Fee Total: Friday, September 4,2009 Amount $871.62 $1,340.95 $2,212.57 Valuation: Total Sq Feet: FEES PAID Inv # BLRE-6-09-19502 $ 2,212.57 Check # 401 $ 161,161.88 2624.50 $944.42 $1;268.15 Fo"osp,,'!on, ,,", 1 (970)384-5003 Inspection IVR See Permit Record Building Department Copy 2 Garage: GARFIELD COUNTY BUILDING PERMIT APPLICATION 1088'" Street, Suite 401, Glenwood Springs, Cu 81601 Phone: 970-945-82121 Fax: 970-384-3470 Iinspoclion Line: 970-384-5003 ffiYj.v.flaJ"f!el.Q.:fou n1v,SQill the assessors Cr, Hwy or Street Name-& City) or and legal description AmJmrltr· Th~rf:'~~~;:'<~;:;~~":<~::~~~~:~~;~~~.~~:~:~~~~rty"d~~b~I~~<"n'm,anfu:nn~'.cr~ Legal Access. issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department Other Permits. Multiple separate penuits may be required: (1) State Electrical Permit, (2) County ISDSPcrmit, (3) anotherpermitrequired [oruse on the property identified above, e.g. State or . County Highway! Road Access or a State Wa':,1eW'.J.ter Dischruge Penuit. Void Permit. ABuilding Permit becomes null and void if the workautho:rized is not commenced within 180 days ofllie date of issuance and ifwork is suspended or abandoned for a period of 180 days af'tcr commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true-and correct I understmd that the Building Department accepts the; Application, along with the plans and specifications and other data submitted by me or on my bchalf(submittaIs), based upon my certificationas waccuracy. Assuming completeness of the submittals and apprm>al of this Application, a BuHdingPermit will be issued granting pennission tome., as Owner, to construct the strncturc(s) and facilities detailed on the submittals reviewed by the BuiJding Department In consideT'dlion of the L'>SUMce ofllie Building Permit. I ~e that! and my agents will comply with provisions of any federal state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (Counl¥ Regulation(s». I acknowlcdgcthat the Building Pen:nitmay be suspl.lndedor revoked, upon notice from the ('..QUIlty, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compli::mce with County Regulation(s) or any other applicable law. I hereby grant permi'iSion to the Building Department to enter Ihe property, described above, to inspect the work. I further acknowledge that the-issuance of the-Building Permit does not prevent the ~~~'~ ~O~ffi~'~';~aJ~i~ro~mi.~~req~umng(,~~f,u ~'~"'~,~=~~,= ~n~f~orr~o;":m:fu:,~""'::m::;uaJ:':;::f~any, inspections of the work by the Bduisicldoivnegr eDde apfatretrm isesnuta dnoc en;.o ot rC (Q2n) ssttitouptep ianng a ccmce<prttraunccteio on fo rre sups0el 1oSflt 'bhieli tsy1 orurc ltiuarbei(list)y o br yfa tchiel iCtyo(iuenst)y i of sfu ecrhro irss ,i no mviioslsaitoinosn , . with federal, state and local lam and County Regulations ~1. withme and my authori7..ed agents, including without THE NOTICE& CERTIFICATION ABOVE: STAFF USE ONLY Special Conditions: Mise --- The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structnre and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tnb or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all mc and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign offby the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (e.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A e.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C. O. for the building identified in the Building Permit. Applicant: Job Address: Suhd-Lotlhlock: FEE ESTIMATE FOR SIF STICK BUILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL PLANS ARE REVIEWED) 2..D] Wil1twV Cr«k Tea\! ) TOTAL VALUATION: \Cl \ I Qb,,! .~ THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: q 14, tfl"* PERMIT FEE: ,) ~ 02.q0 TOTAL: 12t17. 81 PERMIT: SEPTIC= PERC: GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE F AMIL Y DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough infonnation to design your project and provide adequate infonnation to facilitate a plan review. Also, please consider using a design pl'ofessional for assistance in your design and a construction pl"Ofessional for construction of YOllr project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Pl"Ofessional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appl"Opriate\y and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Pennit, must be ou drafting papel' at least 18"x24" and drawn to scale, 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and gnard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2003 IRC, and 2006 IECC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes ______ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes ~ 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes N .lu 4. Does the site plan indicate the location and direction of the County or private road accessing the property? ..-----Yes _v -----"'-__ 2 5. Have you provid~d any RESOLUTIONS and! or LAND USE PERMIT(S) associated with this property? tJ" II\-Yes if Yes please provide a COPY. No ~ 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Dci'/'O/'IGI.,!-~Mi+ SubmHk.cl \p) l"liC9 Yes ~ 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance }¥ith the IRC or per stamped engineered design? Yes ............-~~, .J 'u .h tJb vel'!l:s' -u,(\11\ ~)\D~OL 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and g~ vJ\ ~ clearances requi.red between wood and earth? -'Ie s Yes ~ No _______ __ ,..-Ri~ \/e.nt-9, Do the plans indicate the size and location of ventilation openings for the attic, roof joist sp'aces and soffits?-N trr Silt"'.)"" On Pla.t'l.S " on -tn.-lsS Yes No ......----\o.'1l>!A1-10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? ~ Yes ____ '--___ _ 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? _____ Yes ............ -----bY) +lbor"' jc.\sl-kA.,/6t.D-12. Does the building section drawing include size and spacing of fl~r joists, (Vall stndst ceiling joists, roof rafters or joists or trusses? ~ Dh ---\YuSs \ a.'11:>~-t-\ oerr s.hoU)n. DY'I rl ~> Yes .........---13. Does the building section drawing or other detail include the method of positive connection of all columns $beamS? -{:lcClf' )O'IS+ Ul.,":/l>U,T Yes' ~ 14, Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Buildin~eight measurement usually not to exceed 25 feet) Yes, ______ NU 3 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase. II cs :rti.f il catiOns or phase II EPA certification? Yes No_ __~ _ ___ 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the W.C? Yes N/It No. ____ _ 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rc;9ll1s and/or basements comply with the requirements of the IRC? Yes,-_=~_ ___ 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ______ 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adj acent to such doors; glazing ruljacent to any surface normally used as a walking surface; sliding glass doors; fixed glass paiIels; shower doors and tub enclosures and specify safety glazing for these areas? ~ Yes No_ ___~_ _ ___ 20. Is the location of all natural and liquid petroleum gas fumaces, boilers and water heaters indicated on the plan? Yes ---21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes .....-:---22. Do you understand that if you belong to a Homeowners Association (ROA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes ~ 23. Will this be the onlY residential structure on the parcel? Yes ~ No Ifno-Explain: ______ _ 24. Have two (2) complete sets of construction drawings been submitted with the application? Yes ....-------4 25. Do you unders~that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes,_-"--------'---__ 26. Have you designed or had this plan designed while considering building and other construction code require~ Yes,_~ _ _ 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes ...------28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes .........---29. Do you understand that approval for design and/or construction changes are required prior to the application ofjhese changes? Yes_..:.~=-_-__ 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes ~ 31. Are you aware that you must call in rOl' an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes ~ No ._-----32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes V-33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ~ 5 34_ Are you aware that the Pennit Application must be signed by the Owner or a written authority being given fo~ent and that the party responsible for the project must comply with the IRC? Yes_--= ___ _ 35_ Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are perfonning the work? The license number of the person perfonning the work will be required at time of applicable inspection_ Yes ....;---36_ Are you aware, that on the front of the Building Pennit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this pennit on prior to submittal of a building pennit llRplication? Your attention in this is appreciated_ Yes, __~ ~_~_ ____ 37, Do you know that the local fire district may require you to submit plans for their review of fire safety issues? ~ Y es ~ (please check with the building deparbnent about this requirement) 38_ Do you understand that if you are plauning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading pennit? Yes ~ 39 , Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes ~ 40_ If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service_ No building pennit application will be accepted without such a letter.'I'L Yes NI r-r ead, understand and answered these questions to the best of Date Phone: ('110) 2.1!P -")430 (days); 6 Project Name: bv=os.s R.e.S:lde,nc..e:.Project Address: .;lD"J Id i\ \OW ex-ld:; "\(0..1 \ , Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreqstMar2009 7 INGPE GARFIELD COUNTY, COLORADO INSPECTION wnlLn.. NOT BE MADE UNLESS nils CARD IS POSTED ON "iE JOB MIT Date Issued _~_Cf-,-·_4-1.'-",b~q-,-_______ Permit No • .B1,.j,E~ Cn-().3, ___ -_\~\>ZQ~"'_' _ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. ---Use Blr 00 crowl ~lottClClDed O;tWQ.%B K wjJ:.C.lLl: uncOlJ po1ID:;,,",,,~ __ _ Address or Legal Description 2.D} \hlllll'lvJ Ct 'en-=:Ii:Jlj4_BJ",)i1-cr.n.\e.4'MLU.JI'Ylut'--}\.LLI.'e'"'-~tI",~. ~ ____ _ Owner &()~ flliC)H r w'o\~ne~ Contractor QMJ 'lift \)~. _. Building PermitType J"CSIC) eVlliQ,J...' L' _________________________ _ This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway Foundation I Grouting Insulation Drywall Rough MechanicaI/O-f3-Cff~ Septic Final U C~""d .£Ck," 6-~ GasPiping (C)-/3-cf!~ (You Must Cart For Fina! Inspection) Notes (to include Roofl" place & Windows & Doors installed & Firestopping in place) APPROVED Date THIS PERMIT IS NOT TRANSFERABLE For inspection (.11970-384-5003 Office 9'70-945-8212 108 8th Sireet, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD 0.4.{)q PROTECTP:~X'~~~ (DO NOT LAMINATE) PRaIMINAAV PLEASE VEAlFV JOIST/BeAM SIZE ANI) P1.ACEMeNT. At.-SO '.'aIIFY PWMBING I..OCA'T!ONS. NOW THtS PLAN ASSUMES "lllWOf LOADS ARE ON MEl('TERiORWAU.5. ,.,.,~n:<llAL1 ~.,-,-'~'. "".~"",,,.~ .-...•..•.. -.,' .. ,., .... -, '~'-' ".' .-.... , '~-.... ,~ .. ".~ ... DESIGNI.OAf): fl.(1u,t «I PSf UYE LOAD 10 PSI" DEAl) WAD 50 1'51" TOTAll.OIID l00~tRJItAT!Ot-.l .~ .... ! ,I II MAIN FLOOR OJC".~~ TH1'S OIlAWlNG TO DE CJ.ICt:lCa) 8YOWN6tAt-.l/)~ REAOlNSTAUAttON~ PRIOR TO FAAIoIING. ,..,., II} IIPI'IWVEuse-Of9·lI1"saJ6000~ ltr~ac.s. B} BCIJOXSTNOTOESl6NEJ)T05UPPO IlT l.OAl)S FROM ABOVe. C) SEE AU. NQ1"i;S AND l'.IETAn.5 ON ~ S1'RVCTURAlDAAwtNGS.~l'.IETAn.s. AND BOISE tNSTAUATlON 6tJIDE. ''"--~ __ ~''2009,t9?..". _______________________________________________ _________________________________________ ~ _______ " BOISE CASCADE· BC FRAMER 2.0 US MAIN .. File Name: 09-237-VR.bcf 5/21/200911:46 AM BOISE· Customer: VALLEY RIFLE DENNIS Company: BOISE CASCADE Job Name: THE GROSS RESIDENCE City, State: GRAND JUNCll0N, CO '-..-. Address: Drawn By: BB Location: Mise: AJSTM, ALWOIST®, BC RIM BOARDTM, BCI®, BOISE GLULAMTM, VERSA-LAM®, VERSA-RIM PLUS®, VERSA-RIM®, VERSA-STRAND®, VERSA-STUD® are trademarks of Boise Wood Products, loloC. NOMINAUZED MEMBERS: Product Depth Tag Qty Length Total Len. 9·1/2" BCI® 6000·1.7 OF 9·1/2" 1 11 40'0" 440'0" 2 9 38'0" 342'0" 3 20 32'0" 640'0" 4 6 26'0" 156'0" 5 1 S'O" S'OH 6 1 S'O" 6'0" 7 1 4'0" 4'0" 49 1,596' 0" 1·314" x 9·1/2" VERSA·LAM® 2.0 2800 OF 9-1/2" 8 4 30'0" 120'0" 9 4 26'0" 104'0" 8 224'0" TOTAL LENGTH PRODUCTS: Product Depth Tag Totsl Len. H/8" x 9·1/2" BC RIM BOARD"" OSB 9·1/2" 10 120'0" Be FRAMER® 2002 5/2112009 12:07:48 PM 09-237-VR.bcf 1 of 1