Loading...
HomeMy WebLinkAboutApplication-Permit.pdfGarfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81601-Phone: (970)945-8212 Fax: (970)384-3470 Project Address [PARACHUTE, CO Owner Information Williams Production RMT Parcel No. Subdivision 240901400011 Address PO Box 370 Parachute CO 81635 Peimittvo:.BLC0-4~11:1975 Permit. Type; i;C?IJIIller~ial euUdh)g Work Classl#cation: .f>Jf!:~ Perinit status: Active::· Issue Date: 4/19/2011 Expires: 10/16/2011 Section Township Range Phone Cell 970-683-2288 Contractor(s l Phone Primary Contractor Required Inspections: Power Zone Equipment Proposed Construction I Details Pond #1, pump building FEES DUE Fee Commercial Building Fee Plan Check Fee Total: Tuesday, April19, 2011 (719)754-1981 Yes Valuation: $ 9,012.00 Total Sq Feet: 200 FEES PAID Amount lnv Total Paytype Amt Paid Amt Due $181.25 $117.81 $299.06 lnv # BLCD-4-11-20937 $ 299.06 Credit Card Credit Card $217.91 $81.15 $0.00 Fo""'P"Uo"' ""' 1 (888)868-5306 Inspection IVR See Permit Record Building Department Copy 2 I 108 B'h Street, Suite 401, Glenwood Springs, CO 81601 Ph:970-945-8212 Fx:970-384-3440 !nspectiof! Line:888-868-5306 www.garfield-county.com BUILDING PERMIT APPLICA TJON f_-z Block "No: Subd./Exemption: 2 Job Address: (if on address has not heen u.<.<ifl.ned. please prr>Yide C/1, HWY or Street Name & Cay) or and legal description 1" ~W~t'-'~ ",. "S::l , A C • 1 1 ::5e:> e·, S . .L . ..,... 0 . " '\ At <t"4 ~.0• .,(, ' "' !:iWS I.J 3 4 5 6 7 8 9 en,'o"': I '"«h"s ~,;p: 7 "''"'"t ~ 'lk> LoTS 'J~ S)l\IVJ S2N£' N.:l.SU tJ:l.~c. "'$o Q<..rx_ , Owner: (property owner) v Mailing Address: Ph: . All Ph: w~ ~~~ ~..,~ Pro ~"'+i'.,,., ewll (c-" ·~ "' P,.CY, t~ .. ~ 3 7o P"'"..k_,-\·~ (O ~ '';~'S' (q7o) .:n ~-.)-::so~ Contractor: Ma iling Address: Ph: . Alt Ph: {)ow~' Zc,"" Gc, .~l, m e.;\ 4/olt)O C. IZ E C{ "'f~,.. (.o ~ 11 ;> 5-Ute.) ~c, -· l n l Man ufactured home in! taller: Ma iling Addre ss: Ph: Lie II: Architect: Maili ng Address: Ph: Alt Ph: Engineer: Mailing Address: Ph: Alt Ph: Sq. ft. of Building: Sq. Ft. or Acres of Lot: 'f D... /3 Acn 5 Height: No. of f loors: J.co · II ' 8' 11 I Usc of Building: D Residcntial I Class of Work: • c ommerc ial D Other • New 0 Alteration 0 Addition DRepair DDemo DMove 10 Describe Work: IO' xJo ' ov""'c ~ · \.!,'-".c:. b.(.~o,J~> I ,. J Garage: 1 .J 1 Septic: D Attached DDetached I DISDS II 12 Driveway Permit: 1 Type ofHeat: OCommunity NOTICF. O Nat. Gas Owners va luation of Work: ·¢Jo 1oo.·~ DPropane DElectric OOther ~· Th.is application for a Building Pennit must be signed by the Owner of the property, described above , or an authorized age nt If the signature below is nol that of tl1e Owner, a separate letter of authority, signed by the Owner , must be provided with this Application. Legal Accw. A Building Pennit canoot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Depar1ment. Other P crrnju Multiplt separate penn it~ may he required : ( 1) State Electrical Penni(. (2) County 1SDS Permit. (3) another penn it requi_red for use on the property identified above, e.g. State or County Highway/Road Access or a State Wastewater Discharge Penni1. Void Permit. A Building Pennif becomes mill and void if the work authori zed is not commenced within J 80 days of the date of issuance and if work is suspended or abandoned for a period o f 180 days after commencement. ) · · CERTIFICAT ION I hereby certify that I have read this Application and that tlte infom10tion contained above is tn<e and correct. I understand that the Bui lding Department accepts the Applicatioh, along with the plans and specifications and other data submitted by me or on my behalf (submittals). based upon my certification as to accuracy. Assuming completeness oflhc submittals and approval of this Application, a Build.ing•Pennil will be issued granting pennission to me, as 0"11er, to conslruct the slnlclure(s) and facili ties detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulat ing the work and th~ Garfield County Building Code. ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Pennil may be suspended or revoked, upon notice from the County, if the location, COI)struction or use of the slntcture(s) and facility(ies). dcsctibcd •bove,""' not in compliance with County Regulation(s) or any other applicable law. · I hereby grant pennission to the Building Depanmenl to enter the property, described above, to inspect the work. I funher •<knowledge that the issuance oftl1e Building Permit does not prevent tl1e Building Official from: (1) req uiring the con·ection uf • •m rs in the submiJI•Is. if any, discovered after issu Hnce~ or (2) stopping construction or use of the slrucrure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Applic-ation, including submillals, and inspections of the work by the Buildu1g Deplll1mcnt do not consti tule an acoeplance of <esponsibility o< liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge tha( responsibility for compliance with federal. s tate and local laws and County Regulations rest wi_th me and my Authorized agents, including wi,hout limitation my architect designer, engineer andl~or builder. I HEf ACKNOWLED/ATHAT I HAVE READ AND U NDERSTAND~HE NTOTICE & C/ERTI FICATION ABOVE: ~ )_' )-_('" ) ("'~ -L _.t,~ I ~~ -J ;2<-( I{ c._\\~.&~\,S\~~-r-, ~~~-9-~c-~\\ \) __ OWP/1 l.S SI<fN't\TlJRE/T ATE 1 CQ.""C....'-... '-P L':II·_lP;.~ v f~ (...1-'a ~ ll · "' $ 'Z:{1 . 01 I 'K,(:, 'iTtS STAFF USE ONLY Special Conditions: Adjusted Valuation: ~012 , ()O Plan Check Fee: /1?.81 Pc.rmit Fcc: /81; z5 Manu h ome Fee: Mise Fees: Tota ll?ees: z_ 99.ob Fees l'aid: '2\l .C11 Bala nce Due: B !. ;..) .!!fli2 & Issue Daft: "IC1l5 ~e;~~s~ /Z-JO()~ S /OO /OCC G roup: F f Const Type: ::rz:-{3 ZoninRl I Building Plan Review Description of Work: Pond #1, pump building Bin#: db Location Address: PARACHUTE, CO Case Manager: David Bartholomew Plan Case Number: BLDG-4-11-6804 Parcel: 240901400011 Application Date: 04/06/2011 /Building ----:--Engineered Foundation __f. JA_,.t..t;..__ Driveway Permit ___/_ __ Surveyed Site Plan --~-~{._*_ _S eptic Permit and Setbacks ___/_ __G rade/Topography 30% __}_ .J__/If-_A ttach Residential Plan Review List __ /7___,.----Minimum Application Questionnare _____ Subdivision Plat Notes __l--"{f-_A_-_F ire Department Review --~__,. __ Valuation Determination/Fees --~--J.ti.:.....__Red Line Plans/Stamps/Sticker ---""'7T"""--'Attach Conditions _ __.71~r'"-_Application Signed -----'/---~_Plan Reviewer To Sign Application __ :__ __ Parcel/Schedule No. ~ 40# Snowload Letter-Manu. Homes _LSoils Report Contacts Owner: Williams Production RMT Applicant: Williams Production RMT Applicant Phone: 970-68~2288 Email: Planning/Zoning __ /---=-__ Property Line Setbacks __/_ __3 0ft Stream Setbacks + Flood Plain ---'----:--Building height /Zoning Sign-off __ M_,f.__A __ ,Road Impact Fees __M.. ....;~; '_4 _H OAIDRC Approval -~/'-__ Grade/Topography 40% --~___,//-_Planning Issues -----subdivision Plat General Comments: r/tt/urf/tlfJ1 /!/1#1/-jee (2w;{t() fee ~T/fl.-/fJ#ff'd -~OJ 2 .. ()0 /8/~z.,S _117,_§_/~r;t;.o/:; z, ;7, II I 8/./5 CONDITIONS OF PERMIT BLC0-4-11-1975 WILLIAMS PRODUCTION RMT Pond # 1 Pump Building, Power Zone Equip. Sect. 1, T7, R96 Lots 2, 4 Parachute, Colorado 1) ALL WORK MUST COMPLY WITH THE 2009 IBC AND MANUFACTURERS INSTALLATION SPECIFICATIONS. 2) ALL WORK MUST COMPLY WITH THE CONDITIONS OF THE CURRENT LAND USE CHANGE PERMIT. 3) ALL WORK SHALL COMPLY WITH STATE AND FEDERAL REGULATIONS. 4) EXCAVATION OBSERVATION REPORT REQUIRED FOR FOOTING INSPECTION. 5) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION. 6) LOCKS, LATCHES AND LANDINGS PER 2009 IBC, SECTION 1008. 7) LIGHT AND VENTILATION PER 2009 IBC, CHAPTER 12. March 3, 2011 Garfield County Building Department: ·~l."fll.~ rrllllams~ ~ Williams PRODUCTION RMT 1058 CR #215 Parachute, CO 81635 970-236-5305 This letter will serve as authorization for Power Zone Equipment, Inc. to act on behalf of Williams Production RMT in securing a building permit for the addition of buildings at the Parachute Water Management Facility located in Garfield County. If there are any questions or problems please contact me at 970-263-5305. Sincerely, Sincerely, Joseph J. Lobato Facilities Engineer Phil Vaughan From: Sent: Fred Jarman <fjarman@garfield-county.com> Tuesday, March 15, 2011 4:35 PM To: David Bartholomew; Andy Schwaller Cc: Phil Vaughan Subject: RE: Williams-Parachute Water Handling Facility Thanks Dave. From: David Bartholomew Sent: Tuesday, March 15, 2011 4:06 PM To: Fred Jarman; Andy Schwaller Cc: 'Phil Vaughan' Subject: RE: Williams-Parachute Water Handling Facility Thanks, I'll print a copy and insert it into the building application file. DB David Bartholomew, Plans Examiner Garfield County Building & Planning 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Offi ce: 970-945-8212 From: Fred Jarman Sent: Tuesday, March 15, 2011 2:05 PM To: Andy Schwaller; David Bartholomew Cc: Phil Vaughan Subject: FW: Williams-Parachute Water Handling Facility Hi Dave and Andy, This letter and plan from Phil Vaughan meets the zoning requirements and can serve as the zoning clearance. Thanks-Fred From: Phil Vaughan [mailto:phil@pvcmi.com] Sent: Tuesday, March 15, 201111:02 AM To: Fred Jarman Subject: Williams-Parachute Water Handling Facility Fred, Please find attached materials to assist in our phone call at 1:30 p.m. today. Thanks again for your assistance. Sincerely, Phil Vaughan 1 Phil Vaughan Construction Management, Inc. 1038 County Road 323 Rifle, CO 81650 970-625-5350 2 A Better Panel Inc. Box 6165 4006 -60th Ave. lnnisfail, AB, T4G 1S8 Maximum Allowable Span Table: Panel Specified Design Load (psf) Thickness 10 15 20 1 1/2" 11 '-2" 9'-6" 8'-4" @14'-0" 11'-10" 1 0'-3" 3" 17'-10" 14'-7" 12'-7" 4" 20'-6" 17'-0" 14'-6" 6" 25'-0" 20'-7" 17'-10" 25 30 35 7'-8" 7'-1" 6'-7" 9'-2" 8'-4" 7'-9" 11 '-3" 1 0'-4" 9'-6" 13'-0" 11 '-1 0" 1 0'-1 0" 15'-11" 14'-6" 13'-5" Note: 4" calculations are to be used ONLY as a guideline as they are only preliminary Design Parameters: -Maximum simply supported spans based on the lesser of bending capacity, shear capacity, or defection of span/180, whichever governs, under uniformly distributed load. -Spans are centre-line of bearing to centre-line of bearing. -26 Ga. Steel Skins (minimum 0.019" thick) each face. Minimum yield strength 33ksi. -Polyurethane Foam Core, minimum density = 2.5 lbs/cu.ft. -Factor of Safety of 2.5 used on strength controlled values. -Panel self weight must be deducted from specified values for horizontal applications. Phone: (403)-227-4545 Fax: (403)-227-4535 Toll Free: 1-877-352-7979 ( ·4a ) 45 6¥ 5'-11" rv ) 6'-1 0" __, 8'-11" 8'-5" 1 0'-0" 9'-6" 12'-7" 11'-10" -Thermal effects (thermal bowing) and the possible limiting capacity of connections to, or bearing on, the primary structural system have not been considered in above values. Fire testing in accordance with CAN/ULC S1 02-M88 (panel with joint): Flame Spread: Smoke Developed: 65 210 Canadian Food Inspection Agency (CFIA) approval on selected panels. (A399) A Better Panel Inc. Box 6165 4006 -60th Ave. lnnisfail, AB, T4G 1S8 Maximum Allowable Span Table: Panel Specified Design Load (psf) Thickness 10 15 20 1 1/2" 11 '-2" 9'-6" 8'-4" 2" 14'-0" 11'-10" 1 0'-3" 3" 17'-10" 14'-7" 12'-7" 4" 20'-6" 17'-0" 14'-6" 6" 25'-0" 20'-7" 17'-10" 25 30 35 7'-8" 7'-1" 6'-7" 9'-2" 8'-4" 7'-9" 11 '-3" 1 0'-4" 9'-6" 13'-0" 11 '-10" 10'-10" 15'-11" 14'-6" 13'-5" Note: 4" calculations are to be used ONLY as a guideline as they are only preliminary Design Parameters: -Maximum simply supported spans based on the lesser of bending capacity, shear capacity, or defection of span/180, whichever governs, under uniformly distributed load. -Spans are centre-line of bearing to centre-line of bearing. -26 Ga. Steel Skins (minimum 0.019" thick) each face. Minimum yield strength 33ksi. -Polyurethane Foam Core, minimum density= 2.5 lbs/cu.ft. -Factor of Safety of 2.5 used on strength controlled values. -Panel self weight must be deducted from specified values for horizontal applications. Phone: (403)-227-4545 Fax: (403)-227-4535 Toll Free: 1-877-352-7979 40 45 6'-3" 5'-11" 7'-3" 6'-1 0" 8'-11" 8'-5" 1 0'-0" 9'-6" 12'-7" 11'-10" -Thermal effects (thermal bowing) and the possible limiting capacity of connections to, or bearing on, the primary structural system have not been considered in above values. Fire testing in accordance with CAN/ULC S102-M88 (panel with joint): Flame Spread: Smoke Developed: 65 210 Canadian Food Inspection Agency (CFIA) approval on selected panels. (A399) Inspection Report CO~ORADO STATE ELECTRICAL BOARD INSPECnoN REPORT I CORRECTION NOTICE ~ Date Received: 18-AUG-11 Permit Number: 704192 Jl Contractor/HomeOWner: SOUTHWEST ELECTRIC ll{C 0172 Hays Gulch Road Complete Final Address: TYpe of Inspection: Action: Accepted Comments or Corrections: New permit will be pulled for heat trace and ligllUng Inspectors Name: Gary Freeman Phone Number: 970-Sfk-9525 Date: 18-AUG-11 COLORADO STATE ElECTRICAl BOARD DI:PARTMENT OF REGULATORY AGENCIES 1580 logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https:l/www.dora.state.co.uslpls/real!Ep_Web_lnspection_GUI.Process_Page Page 1 of I 8/26/2011 Permit Card POST ON SITE --Garfield County PermitNO. BLCQ-4-11 .. 1975 Building and Planning Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone: (970)945-8212 Fax: (970)384-3470 •''; ;·~ Issue Date: 4/19/2011 ... AGREEMENT Permit Type: Commercial Building Work Classification: New Expires: 1 0/16/2011 In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulati ons related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Commercial Building Parcel #:240901400011 Owner's Name: Williams Production RMT Owner's Phone: 970-683-2288 Job Address: PARACHUTE, CO Total Square Feet: 200 Contractor(s} Phone Primary Contractor Work Description: Power Zone Equipment (719)754-1981 Yes Inspection Scheduling Code _Inspection ~· • ! IVR Comments Pass Date Footers '105 ):~/r\-t'r tJic 2/r~~ ol( /nr'Z 5"-;);/1 Foundation Walls 110 1-B-~~ ~ ~ ~,l;,y~ ~ Framing 115 (I 1/Drywall 120 Final 125 0~ /?~ Vo-?-lt Mise 135 Insulation 160 Grout 175 Mechanical 405 UG Plumbing 605 Rough Plumbing 610 Gas 620 ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For Inspections Call: 1-888-868-5306 I Account Account: R006514 Parcel Number 2409-014-00-011 Situs Address City Parachute ZipCode 81635 Tax Area 026-16-BHFZDF-026 Qvmex lnformatioo Owner Name WILLIAMS PRODUCTION RMTCOMPANY In Care Of Name SANDY HOTARD, MGR-LAND DEPT Owner Address PO BOX 370 PARACHUTE, CO 81635 Legal Summary Section: 1 Township: 7 Range: 96 LOTS 2,4,S2NW, S2NE, N2SW, N2SE. ALSO, 26 AC. IN THE SWSE AND 32 AC IN THE SESE. ALSO A TR IN THE SWSW CONT. 5.03 AC. Iransi!>J"J; Sale Price IaxJ::Ii.,tory Tax Year Taxes Sale Date 11/1_8/2010 '!Q/H/200_8 1_0/2_1'a_O_Ql! 0411412008 Images • ms Doc Type m £:.6;> RQ_W El\S Page 1 of 1 ,O.s_s_essf11ent History Actual (2010) $5,340 Primary Taxable $1,550 Tax Area: 026 Mill Levy: 39.2830 Type Actual Assessed Acres Land $5,340 $1,550 432.130 Book Page https://act.garfield-county. com/assessor/taxweb/accou nt.jsp?accountN um=R006514 4/6/2011