ACOUSTICAL CONSULTANTS INC.
Date: March 20, 2008
To: Mr. Preston Nelson
EnCana Oil & Gas (USA) Inc.
2717 County Road 215
Parachute, Colorado 81635
From: Tim Simmons, Ph.D.
HFP Acoustical Consultants Inc.
Re: Pre- Construction Sound Level Prediction
Computer Noise Model for COGCC Compliance
South Middle Fork Compressor Station
Garfield County, Colorado
HFP File No. 6466 -1
TECHNICAL MEMORANDUM #6466 -1A -I
A three - dimensional computer noise model was created for the proposed EnCana South
Middle Fork Compressor Station. The design goal is that the total compressor station
sound level contribution be less than or equal to 50 dB(A) at a distance of 350 feet from
noise sources or at the property line, whichever distance is greater. This is in accordance
with the Colorado Oil and Gas Conservation Commission ( COGCC) nighttime noise
limit for a neighboring residential /agricultural /rural zone.
The model was developed using Cadna/A, version 3.7.123, a commercial noise modeling
package developed by DataKustik GmbH. The software takes into account spreading
losses, ground and atmospheric effects, shielding from barriers and buildings, and
reflections from surfaces. The computer noise model calculations are based on "ISO
9613 -2: Acoustics — Attenuation of sound during propagation outdoors." Digital terrain
elevation data, derived from USGS data was downloaded and incorporated in the
computer noise model.
The facility is currently in preliminary design stage, so specific equipment has not been
selected. The analysis is based on currently available equipment lists and drawings.
Scheduled equipment includes:
• Eight 7500 hp electric -drive compressors
• Eight 156 -3 -Z air coolers
• Two CAT 3516 Gensets
• Three CAT 3616 -drive compressors (temporary units)
• Three 144 -2 -Z air coolers (temporary units)
6001 Savoy Drive, Suite 115
Phone: 713.789.9400
#1 140, 10201 Southport Road S.W.
Phone: 403.259.6600
Houston, Texas 77036
Fax: 713.789.5493
Calgary, Alberta. Canada T2W 4X9
Fax: 403.259.6611
March 20, 2008
EnCana Oil & Gas (USA) Inc.
South Middle Fork CS
Technical Memorandum 6466 -1A -1
HFP File 6466 -1
Page 2
The attached Figure 1 shows the compressor station site property line and equipment
layout. The attached Figure 2 shows the predicted A- weighted sound level contributions
from the compressor station at several locations along the property line. The predicted
contributions range from 36.0 dB(A) at the south to 46.5 dB(A) at a location which is 350
feet south/southeast of the air coolers for Compressor Building 1. This location falls just
outside the station property line. These levels are based on the noise control measures
listed in Table 1. All compression and genset equipment is modeled as enclosed in
acoustically treated buildings, in order to meet the noise goal. The air coolers also will
require noise control treatments. Figure 3 (on the following page) shows a 3 -D
rendering of the compressor station and vicinity.
Table 1: South Middle Fork CS - PRELIMINARY DESIGN
Noise Source
Treatment Description
Compressor Building_l
Walls and Roof
Minimum STC -45 absorptive acoustical building
Ventilation Wall Inlets Openings
High Performance Acoustical Louver
Ventilation Roof Exhaust Openings
Ventilation Silencer, 3' long
Personnel Doors
Standard STC -32 Man Door
Equipment Doors
STC -24 Roll Door
Coolers: 156 -3 -Z
Required DIL overall 26 dB reduction
Compressor Building 2
Walls and Roof
Minimum STC -45 absorptive acoustical building
Ventilation Wall Inlets Openings
High Performance Acoustical Louver
Ventilation Roof Exhaust Openings
Ventilation Silencer, 3' long
Personnel Doors
Standard STC -32 Man Door
Equipment Doors
Double Roll Door
CAT 3616 Exhaust
GT 6100 Series High Performance Muffler
Coolers: 144 -2 -Z
Required DIL overall 26 dB reduction
Generator Building
Walls and Roof
Minimum STC -45 absorptive acoustical building
Ventilation Wall Inlets Openings
Enviro Noise Control Air Inlet Hood
Ventilation Roof Exhaust Openings
Ventilation Silencer, 3' long
Personnel Doors
Standard STC -32 Man Door
Equipment Doors
Double Roll Door
H F P
ACOUSTICAL CONSULTANTS
March 20, 2008
EnCana Oil & Gas (USA) Inc.
South Middle Fork CS
Technical Memorandum 6466 -1A -1
HFP File 6466 -1
Page 3
Figure 3: 3 -1) rendering of the proposed South Middle Fork Compressor Station
looking from the southeast.
This completes Technical Memorandum 6466 -1A -1. Please call if you have any
questions or comments.
Respectfully submitted,
HFP ACOUSTICAL CONSULTANTS INC.
)'j .
Tim Simmons, Ph.D.
Senior Project Consultant
Attachments: Figures 1 and 2