HomeMy WebLinkAboutOWTS Installation Observations 11.23.2013ALL 33 Four Wheel Drive Rd
Carbondale, CO 81623
470.389.5259
SIRYIC[6 hp 1 1i
November 23; 2013
Dale Titus
Drtitus0171(a&,gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
171 Fairway Lane
Garfield County, Colorado
Septic Permit SEPT 10 -13 -3012
Dale,
CfrifIr
DEC 0 4 7013
GARF ELL) COUNTY
)MMUN1 T Y DEVELOPMENT
Project No. C1058
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system
(OWTS) on October 19 and 25, 2013 for the subject property. Native Excavation installed the system.
The addition to the house had not been constructed at the time of the OWTS installation.
The installation included a new 1250 - gallon, two - compartment Roth® poly septic tank with an
effluent filter on the outlet tee. The line from the house to the tank appeared to be well - bedded. The
septic tank lids must be no more than 8- inches below grade; however, we recommend accessibility at
grade. There is an effluent filter inside the second compartment of the septic tank. This filter
must be cleaned annually or more frequently, if needed.
Effluent gravity flows to a 20 -foot x 20 -foot x 8.5 -feet deep below the inlet drywell for a total of
1080 square feet of infiltrative area. Irrigation over the drywell should be limited.
The OWTS was generally installed according to specifications. This observation is not a guarantee
of workmanship and /or parts and materials. ALL SERVICE septic, LLC should be notified if
changes are made to the OWTS in the future. Any additional OWTS construction must be according
to the county regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer
must have documented and demonstrated knowledge of the requirements and regulations of the
county in which they are working. The quality of the installation is dependent of the expertise of the
installer, soil type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
eek.A Cep Ds -t-&uts
Carla Ostberg, MPH, REHS
Reviewed 13y:
Richard 11. Petz,
Line from house to septic tank Inlet tee
View of 1250 - gallon septic tank
Pipe coming into drywell
Effluent filter on outlet tee
Septic tank with risers
Measuring area of drywell (notice observation port)
me-
Fabric over dispersal gravel
Measurement o drywell (over 20 -feet)
Inlet of drywell
Extent of drywell measures 8.5 -feet below inlet
LOT 29�
2
1-150' MIN.
O
PROPOSED
ADDITION
20' x 20' x 8.5' DRYWELL-
WITH 4' CONCRETE
PERFORATED RISERS
4" DIA SDR 35 SEWER
LINE (SLOPE 2
1% MIN TO DRYWELL)
1250- GALLON,
TWO - COMPARTMENT,
CONCRETE SEPTIC TANK
WITH EFFLUENT FILTER
4" DIA SDR 35 SEWER
LINE WITH CLEANOUT
(SLOPE 2% MIN TO TANK)
0' 15' 30'
Scale: 1" = 30' =0"
LOT 30
1.131 ACRES
THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE
NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE
APPROXIMATE. IT I5 THE HOMEOWNERS DUTY TO ENSURE ALL
CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL
SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION.
CD RECORD DRAWING
Date: 11/23/13
Designed By: CBO
Checked By: RHP
Drawn By: ANG
fl
MICE
33 Four Wheel Drive Road
Carbondale, CO 81623
970.704.0484
Titus Residence
171 Fairway Lane
Garfield County, Colorado
Project Number: C1058
record