HomeMy WebLinkAbout1.1 Typical Trench DetailOPEN F1EtD New Street Surface Per Plans ' 1 Existing Street Surface Compact to 95% Proctor or as specified by Geotechnical Engineer �Tl IN STREET Trench Resurfacing Uniform Cut Line Asphalt /Concrete Trench Min /Max Per Table A e 6' 1 Existing Bose Course 3/8" Screened Rock TYPICAL TRENCH SECTION • NOT TO SCALE Pipe Diameter Minimum Width Maximum Width 4" 1' -4" 2'-4-" 8., 1._8„ 2'-6" 8" 1' -8" 21 -8n 12" 2'—O" 3'_0" 16" 2'_4" 31_4„ 20" 2'_8" 31_8„ 24" 41 -0" 5' -0" PO Box 1301 COLORADO Rifle, CO 81650 RIVER Te1970- 625 -4933 ENGINEERING Fax 970 - 625 -4564 Civil Engineering .Water Rights, Augmentation Plans .Groundwater, Well Permitting Hydrology, Flood Plain Analysis .Canals, Pipelines, Dams FIGURE NO. TYPICAL TRENCH DETAIL File Name: TypTrench.dwg Job No: 600 Drawn by: MH I Aprvd by: CM Date; Dec 03, 2004 Client: Regulski