Loading...
HomeMy WebLinkAboutApplication.pdfcG Garfield County Community Development Department 108 81h Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-8212 www.garfield-county.com ·-·---·¥¥••··------------~--------··-·--··--·---·-··-------····-------··-------···----------·--·---···-·-··----·--------·-·-··-·------···--------------·---·------~- TYPE OF CONSTRUCTION D Commercial/Multi-Family I D Demolition D Manufactured Home (SF or Duplex) J2I' Residential (SF , Duplex, or Town home) I D Re roof ·- INVOLVED PARTIES "' Property Owner: A-nfk a'd c , t fhmefo M . S~l d afi: Phone: ( 9Jo ) 3 0'1-S 7 'to Mailing Address: 55 B ea~e c:. L1:1 ~ Ccv-\i&\dct.\~ LO / gn~3 Contractor: Re5o d:. be.llt'h41roel6.+ & v1 l,l1 ~S A,,,-/llc.n c.f c · S e!l do.#-Phone: ( 9 10 ) 3 e>'i-S1'fD Mailing Address: 5S Bea.ver Lb ' Ca --b c:od,1 ie ((). g f b J.J ,. Architect: ::I]'('(i-: Phone: ( q 70 ) Cfa 1 -$1 (,I ~ J G 3 ~ ~o -# 1 l . ~a ~() H Co g/6J I Mailing Address: -~~o ~I ~1 e.c.J: ' 7 -, Engineer: \K'&-A Phone: ( '1 )Q ) 9-J.1 -3 16 1 Mailing Address: ~ s.J 'i?O ":(. I 1 ·~w t} R\~r~ \'.;2_d 1 I _e~·g.lb ((') f_lt,J' Manufactured Home Installer: Phone : ( ) Mailing Address: PROJECT NAME AND LOCATION Describe Work: So\do -Ff r1 e s'.1 &e ~ '-E 7 S I~ l ~ +a h'\,1 t 1-t heme Job Address: q~ E \-h~ \'\ )n r A , G-\.D \11 \~"'Ii-I r)l'j " ,, l;;L-K Sl°R.\ N C·S \:LG S Assessor's Parcel Number: 5'LJ1qo Sub. L.~ ~ A ll:l i~a.I ru"'~ Lot ~ X. Block ~ Owner's Valuation of Work:$ d,00, ODO 1 00 Property Size @ r Acres): 15'/,(..5'1 SF? ' Sq .Ft of Building: 'Ji 6 Cf I Cf_ Height: 0-~ 1 # of Floors : ~ - J2I New I D Alteration I D Add ition ---0 Repair I D Class of Work: Move/Relocation Garage: ja' Attached D Detached Septic: 0 ISDS .0 Community Type of Heat: 0'Natural Gas I D Propane I D Electric I D Other Driveway Permit: D Exempt D Permit#: ~---~~~~~~~~-~~~~~-~~~~-~~~~~~--.~.~--~-~~~~~~~~~·---. NOTICE Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. If the sig nature below is not that of the Owner, a separate letter of authority, signed by the Owner , must be provided with this Application . Legal Access. A Building Permit cannot be iss ued without proof of legal and adequate access to the property for purposes of inspections by the Building Divi sio n . Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Acce ss or a State Wastewater Di scharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of iss uance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plan s and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Perm it will be iss ued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Divi sion. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regu lations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Divi sion to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issua nce; or (2) stopping construction or use of the structure(s) or faci lity(ies) if such is in violation of County Regulation(s) or any other app li cable law. Review of thi s Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance of resp onsibility or liability by the County of errors, omissions or di sc repancies. A s the Owner, I acknowledge that responsibi lity for comp liance with federal , state and local laws and County Regulations re st with me and my authorized agents, including without limitation my architect d es igner, engineer and/ or builder. I hereby acknowledge that I have read and understand the Notice and Certification above as well as have provided the required information which is correct and accurate to the best of my knowledge. l>+m~tt fA. • So1 do++ ~~tandSign OFFICIAL USE ONLY Special Conditions: Adjusted Valuation : Plan Check Fee: Permit Fee: M anu home Fee: '26~015. 12 I '25~. 82 } q ;Z.8 , q5 Total Fees: Fees Paid: B :<, Balance Due : BP No: -;Jez .. 1'1 ~rolsis. lq Z S . q5 Setbacks: OCCGroup: .If2c BUILDING/PLANNING DIVISION ' ~ Signed Approval Date Misc Fees : ISDS No: oi; I VALUATION FEE DETERMINATION Applicant Address Date So ldoff Reside nce Subdivis ion -------------~ _T_B_D"'"'",_G_le_n_w_o_o_d_S.._pr_in_.g._s ______ Lot!Bl ock 5/27/20 14 Contractor ~------------- Finished (Livable A rea): Ma in Upp er Lowe r Oth er Total Tota l Basement: Unfini shed Squa re Fee t Valu at ion Co nve rs ion of Unfini shed to Fi nis hed Othe r Total Valu ation Garage/S torage (wood frame d) Co nve rs ion of garage to fini s hed livin g Carpo rt Ot her Tota l Va lua tion Craw l Space Total Va luat ion Decks/ Pa ti os/Porches Covered Op en Oth er Total Va lu at ion Typ e of C on s truction: Occ upancy: Total Val uation Total Valuation 176 1 sq.ft sq.ft 1523 sq.f t sq.f l X $74.68 3284 sq .ft sq.fl X $41 .00 sq.fl X $33.68 sq.fl X 680 sq.ft X $18.0 0 sq .ft X $56.68 sq.ft X $12.00 sq.ft X 238 sq.ft X $9.00 266 sq.ft X $24.00 sq .ft X $12.00 sq.ft X C ommercial sf x sf x sf x s f x s f x sf x Los Ami gos Ranch Lot# 49 Ow ner 245,249.12 0.00 12 ,240.00 2,142 .00 6,384.00 0.00 266,015.12 Building Plan Review Description of Work: new s/f dwelling with partial crawl space, walkout basement and atta• Bin#: Location Address: TBD Elk Springs/ Los Amigos GLENWOOD SPRINGS, CO Case Manager: David Bartholomew Plan Case Number: BLDG-5-14-7930 Parcel: 239305107013 Application Date: 05/19/2014 Building / Engineered Foundation P/11 I Driveway Permit / Surveyed Site Plan fJ/A Septic Permit and Setbacks / Grade/Topography 30% / Attach Residential Plan Review List / Minimum Application Questionnare / Subdivision Plat Notes JJ/// ' Fire Department Review / Valuation Determination/Fees / Red Line Plans/Stamps/Sticker / Attach Conditions C Application Signed /' Plan Reviewer To Sign Application / Parcel/Schedule No. !f A 40# Snowload Letter -Manu. Homes / Soils Report Tuesday, May 27, 2014 Contact s Owner: Pamela Soldotf Applicant: Pamela Soldoff Applicant Phone: Email: soldoff5@aol.com Planning/Zoning I Property Line Setbacks I 30ft Stream Setbacks / Flood Plain / Building height ( Zoning Sign-off / Road Impact Fees #'?J'?.tJ7 I HOA/DRC Approval 7 Grade/Topography 40% / Planning Issues I Subdivision Plat General Comments: The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Septic or Road Impact fees will be collected when the permit is issued . The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied until a Certificate of Occupancy (CO) is issued . Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises . (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowledge I have read, understand, and will abide by the requirements of this checklist. Date cG Garfield County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-8212 www.garfield-county.com SINGLE FAMILY OR DUPLEX BUILDING PERMIT APPLICATION CHECKLIST In order to understand the scope of work intended and to expedite the issuance of a permit , it is important that complete information be provided. Please review this document to determine if you have adequate information to design your project and to facilitate a plan review. APPLICATION FORM: Please make sure the following information is provided on the application. / • Parcel number obtained from the County Assessor's Office. v • Job address (assigned physical address) v-• Legal Description: lot, block, filing, subdivision or tract, section, township and range . ~ Owners name, mailing address, phone, fax, or cell. v • Contactors name, mailing address, phone, fax, or cell. / • Architect/Engineer's name, mailing address, phone, fax or cell. v • Building size, height, number of stories, lot size. " • Use of building (residential) ,,,,,.. Class of Work (new, addition, alteration, repair, demo, move, other) .,.....-Description of work. ~·--Type of heating (natural gas, propane , electric, other). ~ Sewer system (Community or ISDS), also see other items below. --<" Garage (attached or detached) . ....-Driveway permit (please see other items below) V Valuation (labor and materials) see attached worksheet. OTHER ITEMS: • If you anticipate obtaining a water-tap from the City of Rifle, please provide a letter indicating that the City will provide water service . (Required to submit building permit application). • ISDS requires a septic permit application to be submitted with the building permit application. • A separate electrical permit must be obtained from the State of Colorado Electrical Board. • At the time of building permit submittal, you are required to show proof of legal and adequate access to the site. This may include proof of right to use a private easement, County Road & Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The County Road & Bridge Department can be reached at 970-625-8601 . • If you anticipate excavating or grading prior to issuance of a building permit, you will be required to obtain a separate grading permit. • If you belong to a Homeowners Association (HOA), it is your responsibility to obtain written approval, if required. • Provide copies of any Resolutions and/or Land Use Permits associated with this property. • Additional Dwelling Units may require Administrative Review. • Minimum dwelling dimension is 20 ft wide x 20 feet long. • A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups, unless the homeowner is performing the work. BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete, identical, legible, and to scale. All plans will be checked at the counter for completeness. If any of the required information is missing, the building permit application cannot be accepted. SITE PLAN: Please make sure the following information is provided on the site plan. • Property address/legal description. • North Arrow and Scale on each page. • Show all property lines, building envelopes, flood plain, and easements. • Provide setback distances from boundaries, buildings, septic, well, and waterways. • Location and direction of the county or private road and driveway accessing the property. • Proposed and existing structures include sheds, barns, decks, patios, and any other buildings. • Existing and proposed grade, positive drainage around structure (to be contained on site). • Streams, rivers, creeks, springs, ponds and ditches. • Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable) • Retaining walls (engineer stamped detail required for walls over 4 ft, measured from bottom of footing to top of wall). NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property line or not within an established building envelope shall be prepared, stamped, and signed by a licensed surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision final plat with the proposed structure located in the building envelope. ARCHITECTURAL PLANS: Please provide the following information on the architectural plans. • Minimum four (4) elevations (N,S,E,W) Indicate height of building measured from existing grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat roof. • Floor plans for each level including dimensions and scale noted. • Clearly label each room or space (bedroom, bath, kitchen, closet, etc). • Show the location of the mechanical equipment. • Building cross sections with construction details. • Window sizes, types, and operation noted on the floor plans or elevations. • Specify roof slope/pitch, roof covering, and siding materials. • Stair and guard details specifying rise, run, height and spacing. • Attic, roof, and crawlspace ventilation details. Indicate size and location of ventilation openings. • Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces. • Provide stove and fireplace make, model, EPA or Colorado Phase II Certification. Masonry fireplaces shall be designed to the International Residential Code (IRC) requirements. STRUCTURAL PLANS: Please provide the following information on the structural plans. • Design specifications to include roof and deck snow load, wind and seismic design, frost depth. • Foundation plan showing complete footing and foundation dimensions. • Footing and foundation details specifying reinforcement and referenced on plans. • Framing plans for each floor level and roof. All beams, columns, joists, rafters, and trusses specified. Pre-manufactured structures require the engineers stamp, signature, and date. • Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: If any required information is missing, delays in issuing the permit are to be expected. If determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit.