HomeMy WebLinkAboutApplication.pdfGarfield County
Community Development Department
108 81h Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-countv.com
TYPE OF CONSTRUCTION
INDIVIDUAL SEWAGE
DISPOSAL SYSTEM
{ISDS)
PERMIT APPLICATION
cg, New Installation I D Alte r ation I D Repair
WASTE TYPE
$-Dwelling I D Tran sient Use I D Comm/Industrial I D Non-Domestic
D Other Descr i be
INVOLVED PARTI
Property Owner: *="''""'=-ir-~..._+-><:-+-__..,._,...._"-+--__,,,_+-"'--""'--~--Phone : 7 Q )__,.-"<-<-=-----'.,ll-1---""''-'-I
Mailing Address: .tf,"3 6() ,3 I ;<; +eJ ,
Mailing Address:-------------------------------
Engineer : D C..V e c Phone: ( __ --"'-... :S"'-°':..:....;_vn___;._L.=---=-----
Mailing Address :-------------------------------
PROJECT NAME AND LOCATION
Job Address: _......_........_......__ ....... ..__ ________________________ ----i
Assessor's Parcel Number: 25CJ 'j,;J ~OlCb ld9.iub . Lot Block
Building or Service Type : Ho\')'\'£,_.. #Bedrooms : 3 Garbage Grinder®
Distance to Nearest Community Sewer System: l 3 lfY) { le S ,
Was an effort made to connect to the Community Sewer System: __ ..... AJ ___ +(_A-_,__ ___ ___,... ___ _
J
Type of ISDS ~Septic Tank 0 Aeration Plant 0 Vault 0 Vault Privy 0 Composting Toilet
D Recycling, Potable Use D Recycling D Pit Privy D Incineration Toilet
D Chemical Toilet D Other _______________ _
Ground Conditions Percent Ground Slope --Ci!!>----.•
Final Disposal by ,ig. Absorption trench, Bed or Pi t D Underground Dispersal D Above Ground Dispersal
D Evapotranspiration D Wastewater Pond D Sand Filter
D Other ________________________ _
Water Source & Type Cl. Well D Spring D Cistern
Effluent Will Effluent be discharged directly into wate D Yes t,l!!(. No
CERTIFICATION
Applicant acknowledges that the completeness of the application is conditional upon such further
mandatory and additional test and reports as may be required by the local health department to be
made and furnished by the applicant or by the local health department for purposed of the evaluation
of the appli cation; and the issuance of the permit is subject to such terms and conditions as deemed
necessary to insure compl iance with rules and regulations made, information and reports submitted
herewith and required to be submitted by the applicant are or will be represented to be true and
correct to the best of my knowledge and belief and are designed to be relied on by the local
department of health in evaluating the same for purposes of issuing the permit applied for herein. I
further understand that any falsification or misrepresentation may result in the denial of the
application or revocation of any permit granted based upon said application and legal action for perjury
as provided by law .
I hereby acknowledge that I have read and understand the Notice and Certification above as well as
have provided the required information which is correct and accurate to the best of my knowledge.
6~rl'i Cor. ell f "--e(?. .5 ·~+i . S _ I q _ I Zf'
~ rl~ · te
Special Conditions:
Permit Fee : l :$ f7!2-Perk Fee: I fJO .~ Total Fees: 113.~ Fees Paid:
Building Permit Issue Date : Balance Due: 173 .~
APPROVAL
Garfield County
Community Development Department
108 81h Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-county.com
SEWAGE DISPOSAL PERMIT CHECKLIST
INDIVIDUAL SEWAGE
DISPOSAL SYSTEM
(ISDS)
APPLICATION CHECKLIST
Permit applications can be obtained and submitted to the Garfield County Community
Development Department at 108 ath Street, Suite 401, Glenwood Springs, Colorado . See
below for additional information . All applications are requ ired to be submitted in person .
PERMIT APPLICATION & SUBMITTAL REQUIREMENTS:
• Complete application.
• 1 Copy of a Site Plan that includes well , all streams, irrigation ditches, and any
water courses. Draw in your house, septic tank & system, detached garages,
and driveway. If a change of location is necessary, you must submit a corrected
drawing.
• Engineered System will need copy of perk rate and design for our records prior to
final inspection.
FEES. FEES ARE NOT REFUNDABLE
Make Check payable to: "Garfield County Treasurer"
• Septic Permit for a New installation ...................................................... $73.00
• Septic Permit for alteration and/or repair ............................................... $73 .00
• Septic Perk test .............................................................................. $100 .00
ATTACHMENTS
• Percolation Test Instructions
• Recommended minimum requirements for Individual Sewage Disposal System
(ISDS).
FINAL INSPECTION
• When all components are in place, co nnected and ready to cover, req uest a final
inspection by the County Inspector.
• DO NOT backfill any part of the system prior to the inspection .
• The initial fee covers the percolation test and one ( 1) inspection before cov er up.
Any additional percolation t est will be charg ed at $100 .00 each and additional
inspections will be charged at $50.00 each.
• Upon final approval, carefully cover the entire system .
• Engineered Systems are inspected by the Engineer prior to backfill . A final sealed
letter by the Engineer is required to be submitted to Garfield County.
PERCOLATION TEST INSTRUCTIONS
• The successful operation of your septic system depends on the rate the soil in which your leach
field will be installed will accept water.
• THIS IS CRITICAL If instructions are not followed completely, technician may not do the
perk test and you will be charge a $50.00 fee for 2"d visit.
• The rate of absorption is called the percolation rate and it determines the size of the leach field
needed for a particular flow of sewage and in some cases even determines the feasibility of the
installation of a septic tank and leach field system .
• PERCOLATION TEST MUST BE DONE AT THE GROUND DEPTH WHERE ABSORPTION
WILL TAKE PLACE. STANDARD LEACH FIELDS ARE INSTALLED THREE FEET DEEP,
SO THE 3 PERCOLATION HOLES ARE DUG FOUR FEET DEEP, AT LEAST 20 FEET
APART , IN A TRIANGLE SHAPE. THE PERCOLATION TEST IS DONE IN THE BOTTOM
ONE (1) FOOT OF THE HOLE .
~I
Post Hole
i'i\').11
"'pa----
1
I
I
I
I I
l)~i1~-iiii-1 -w-~~-, ~ ......
I clttP J \./ ---
(o~)
Backhoe Hole
'-'>(.\"\t( 11 1~11 fo11 11 J \ .... _gtt.f .. J. ---
~'
A posthole digger, auger or backhoe can be used to dig the percolation test holes . If a back hoe is
used , dig the backhoe hole 3 feet deep, with 2 steps or a ramp . Put a test hole 1-foot deep and 8 to 12
inches in diameter in the bottom . Installation of absorption areas (i.e. drywells) deeper than three 3 feet
require the permission of the Environmental Health Department. All dry wells shall be designed by an
Engineer registered in the State of Colorado .
Saturation with water will affect the percolation rate, and since the system will be expected to operate
when the soil is saturated with water, THE LOWER TEST HOLE MUST BE FILLED WITH WATER AT
LEAST 8 HOURS BEFORE THE TEST AND ALLOWED TO STAND. More water will be needed to
perform the percolation test, so AT LEAST 5 GALLONS OF WATER PER HOLE SHOULD BE ON HAND
WHEN THE TEST IS PERFORMED .
AN 8 FOOT PROFILE HOLE IN THE LEACH FIELD AREA IS REQUIRED BY THE STATE OF
COLORADO TO DETERMINE THE PROXIMITY OF GROUND WATER AND BEDROCK. (One soil
profile hole shall be dug to provide observation of the soil profile of the area of the soil absorption system.
The hole shall be prepared at least 8 feet deep. The hole may be terminated when ground water or
bedrock is encountered . The hole shall be prepared in such a way as to provide identification of the soil
profile 4 feet below the bottom of the soil absorption system .)
If ground water is found in any perk or profile hole, an engineered systems is required. Percolation
rates faster than 5 minutes per inch or slower than 60 minutes per inch require engineered system
and/ or Board of Health approval.
(Applicant's Copy)
RECOMMENDED MINIMUM REQUIREMENTS FOR
INDIVIDUAL SEWAGE DISPOSAL SYSTEMS llSDS)
Before construction is started, the Inspector must be contacted for approval and detailed information concerning the proposed
disposal system is needed . Higher standards than those wh ich follow may be required in individual cases to assure attainment of
the objective . Those objectives are to locate, construct and maintain indiv idual sewage disposal systems in such a manne r that
existing or contemplated water supp lies will not become co nta minated and so that sewage will not overflow the ground surface
and result in a nuisance or health hazard .
LIQUID CAPACITY OF TANK (GALLONS)
(Provide for use of garbage grinder, automatic clothes washer and other water us in g household appliances).
Number of Bedrooms Recommended Minimum Tank Caoacitv
2 or less 750 gallons __
3 or less 1,000 gallo ns
~
4 or less l 1,250 qallons
For each additional bedroom, add ' 250 qallons I
Dwe lli ng on less th an two acres, areas of high water tables, or areas with a percolati on test rate faste r than 1" in 5 minutes must
have alternative sewage facilities, i.e ., central collection , holding tanks , individual treatment, etc .
EXEMPTION: Abso rption areas may be allowed with percolation rates faster than one (1) inch in five (5) minutes provided the
soil is a sandy texture and no water table problems are encountered. An Engineer is required .
Slopes gre ater than 30% also require an Engineered System .
1. Ma ximum lenqth of drainaqe line : I 100 lin ea r feet
2. Minimu m width of drainaqe trench: I 18 inches
3. Minimum spacinq between trenches or pipes : ; 6 feet
4. Maximum qrade of drainaoe system: I As level a~ossib l e
5. Minimum depth rock under dra in PVC : I 6" under PVC, 2" over PVC
6. Minimum dep th of cover over distribution lines : ! 12 inches
7. Maxim um depth of cover over distr ib ution lines : I Variable
8. Minimum orade of house sewer: I 1/8 to Y." per linear ft .
9. Minimum distance of sewaoe disposal system from dwellinq : ~ 20 feet
10 . Minimum distance of septic tank from dwelling : I 5 feet
11. Minimum distance of leac hin g area to a well : I 100 feet
12. Minimum distance of septic tank to a we ll: 1 50 feet
13 . Minimum distan ce of le ac hin q area to a stre am of water course: I 50 feet
14. Minimum distance from septic tank and disposal field to property lines: f10teet for drywell
i 10 feet for leach field .
15 . Minim um sewer pipe and distribution pioe : I 4 in ch diameter
Septic tank const ruction should be of conc rete , conc rete block or of a materia l that will resist dete riora tion and which
ca n be made reasonable watertight.
• Acceptable drain field pipe mat eri als include plastic, terr acotta or co ncrete . If th e house sewe r lin e is longer than 10
feet betwee n house and septic tank, a clean-out Y should _b e installed ou tside as near as prac tical to the house .
• Septic tanks should be inspected once a year and cleaned when necessary. Cleaning is recommended when space
between the scum accum ulat ion and sludge residue on the tank bottom is less th an eig hteen (18) inches .
• The Department recommends pumping a septic tank once every fo ur (4) years, when a yea rly inspection by the owner is
not practical.