HomeMy WebLinkAboutApplication.pdfOb En GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Permit 4225 Assessor's Parcel No. This does not constitute a building or use permit. s , (p Ce, �' S7 Co- s/oz Owner's Nameiv ��� 1—DP Address ) one System Location 1 t S(L) ( R 3G,‘ Legal Description of Assessor's Parcel No .79'--)90-0O-(00 SYSTEM DESIGN Septic Tank Capac Other Percolation Rate (mi • - h) Number of Bedrooms (or other) Required Absorption Area - See Attached Special Setback Requirements: Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements Other (gallon) Date -5—'3v—°9— Inspector U iL �oqe Cmqmeer) RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE 1-! *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT OWNER ADDRESS " INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION + J :2,, ,1. &eLC/V' I l .h 6 c. R. 352 - CONTRACTOR 52 CONTRACTOR C,4),€ ({i� F,4/49,A / PHONE C/'7 0 511OF ADDRESS cos -c/ c P PERMIT REQUEST FOR (4) NEW INSTALLATION PHONE ?7 ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town R. ,` f ` -C CO Size of Lot / Sce,(-- Legal Description or Address / / ,.6- 6: C k - ;'� � /4,? ��'l� C C) WASTES TYPE: ( ) DWELLING ( ) TRANSIENT USE (X) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER—DESCRIBE BUILDING OR SERVICE TYPE: G -Cf =, r e / S -h vg Number of Bedrooms Number of Persons / — /F ( ) Garbage Grinder ( ) Automatic Washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ( ) WELL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: /ice / p), Was an effort made to connect to the Community System? N 0 A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 2 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: SEPTIC TANK VAULT PRIVY PIT PRIVY CHEMICAL TOILET( ) ( ) AERATION PLANT ( ) COMPOSTING TOILET ( ) INCINERATION TOILET OTHER -DESCRIBE FINAL DISPOSAL BY: ( ABSORPTION TRENCH, BED OR PIT ( ) UNDERGROUND DISPERSAL ( ) ABOVE GROUND DISPERSAL ( ) OTHER -DESCRIBE VAULT RECYCLING, POTABLE USE RECYCLING, OTHER USE ( ) EVAPOTRANSPIRATION ( ) SAND FILTER ( ) WASTEWATER POND WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? /1/ 0 PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. _ Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed Ue1<-6 - Date F_ -0 6 PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! 3 CIVIL ENGINEERING May 23, 2007 An Employee -Owned Company. Andy Schwaller Garfield County Environmental Health 108 8th Street, Suite 201 Glenwood Springs, CO 81601 Re: Elder Property HCE Project Number 2061010.00 Dear Andy: LAND SURVEYING RECEIVED MAY 3 0 2007 LD ,.'OUNTY uviLDING & PLANNING The following letter is to confirm the engineer's acceptance of the designed septic system of the Elder property, 1156 CR 352, Rifle Co 81650. The design included a 1,000 gallon septic tank, and bed system. A 1,500 gallon septic tank was installed instead of the 1,000 gallon septic tank, and the bed system configuration was moved about 165 feet south and rotated per site conditions per the attached as built drawings. The pond was re -located as well to best fit the topography and maintain the 50' setback distance from the field. All of the inspection wells, infiltrators, manifolds, and cleanouts were inspected and were installed satisfactory. With the above noted changes, the system has been completed with the intent of the original design. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENG . ' V ' 1 G, INC. oger ► eal Se Project Manager 1517 BLAKE AVENUE, SUITE 1 01 GLENWOOD SPRINGS, CO 81601 970-945-8676 • PHONE 970-945-2555 • FAX WWW 1-IrFNr rnU 14 INVERNESS DRIVE EAST, SUITE F-120 ENGLEWOOD, CO 80112 303-925-0544 • PHONE 303-925-0547 •FAX High Country Engineering, Inc. 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 (970) 945-8676 Field Report Conditions: /° l/oupY Project Name: fi_ckt /� ,nuc. t5n 5 Project Number: dao /o/o. en Contractor: Subcontractor: PA Report Prepared By: 7Z0 Attachments: Yern/�S • (r) -7)J rcc-7roo _21-5-P5 fS Y�au_ou s: t5-; t -U[ JT j-y,_yct /1Jb7,4 .� c-c—r / LI!?L N STic Date: 4-/ �U y Lrt-tucvr f' [ uS7Zt 73 142-1127)v-roa 1-7)-7‘,6 Scrn c_ Fij-cO. Scrirc, ba -c7 /51A, anai, 1/0 w/ fez' ,w ,4. /3cir�-� So (-7 L 7ro;-) ANC oF' n-ks."Aus:D /cT rcz,G> 'Ste -hi A-5 231I/Cr IGrrce T�"�` L7 SNnr Photo Documentation: CYTS a uear Fi�7 04 0- / thutiZw/ 7Y7741c. rsa2z7160 Loi3c. 607' E17alt1a/rLrpc/3(ue"3 /ea 008 - flan Temp: 6,C' High Country Engineering, Inc. 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 (970) 945-8676 Field Report Conditions: Project Name: jictr_ / nos Project Number: /O / U, oo Contractor: r Fj Date: A2,5% Subcontractor: Temp: s / e Report Prepared By: Attachments: Ti2w�Sr7C 64/7) Qu 5(Tz ) `-(7_4° ✓a) t y SL /3,e4 -r �F �Ur� /���V✓�y\ C�vSrny�Tio� ✓tel 43k-/ir UY' 0r T.C) Ft L7324 71-0 /3&_)---7 7s .' Ki ) tir 7s-n2._,c.TiOnJ or ff, w/ L11.0—z 7;- 1-7/10-77/ J C/ / /-7211 6P--/(00-26, f_JG . /4-)/L j2f'Y 27/9 1-- T72; _4hz^r Jtx 51-6".)°/= -70p3 �(n� Sr Tc /tel / 1,..° m FT -M-0 l /3c. G .J —CUP ICL l r FGG tifV /" Uf-7 F%Lc w C..._ l� .r u (7�� Photo Documentation: - Stone - war- Bw& T of /3L -G 0/� A=m 0I2- X-)16P-7,4Vat) t-7F2w 0) 3 - l ouo Cb,u>Te-re C> (4 ( MO 7&'J ,% &7LL1> )D 100 LF OF 4" PVC 0 2% MINIMUM GRADE PROPOSED CLEANOUT 100 LF OF 4" PVC 0 2% MINIMUM GRADE co 0 0 ic=aco�td/ oDo 1R6POSEDLf GALLON SEPTIC TANK WITH BAFFLE Gni G ? rThi PROPOSED BED SYSTEM_\i EXISTING RESIDENCE 1 44' 47 LF OF 4" PVC 10 2% MINIMUM GRADE 50' MINIMUM PROPOSED RETE SECTIONS 20 & 21, TOWNSHIP 8 5, RANGE 83 W, 6TH P.M. CONTRACTOR TO VERIFY SETBACKS FROM ADJACENT PROPERTY MINIFY MAP SCALE: 1" — 2000' PROPERTY BOUNDARY EXISTING RESIDENCE RESIDENCE 2 CEIERAL NOTES I. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE GARFIELD COUNTY AND THE CDPHE REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. UKELY CONFIGURATION FOR THE PROPOSED RESTROOM FACILITIES. OPTION ONE: 4 8-1-1OUR SHIFTS FOR ONE FACTORY AND 2 8—HOUR SHIFTS FOR ONE OFFICE BUILDING PER CDPHE GUIDELINES FOR COMMERCIAL CONFIGURATION, THE AVERAGE FLOW 15 170 GALLONS PER DAY OPTION TWO: 3 BEDROOM SINGLE FAMILY RESIDENCE WITH 2 PERSONS PER BEDROOM PER CDPHE GUIDELINES, THE AVERAGE FLOW 15 450 GALLONS PER DAY. OPTION TWO WAS USED DUE TO THE HIGHER FACTOR OF SAFETY THEREFORE, THE AVERAGE DAILY FLOW EQUALS 300 GPD DESIGN FLOW = 1.5 * AVERAGE = 675 GPD (Q) SEPTIC TANK SIZING 0 * 1 DAY/24 HRS * 30 HRS = 844 GALLONS INSTALL ONE 1000—GALLON TANK WITH BAFFLES INFILTRATION TRENCH SIZING A = Q „fT Q=MAXIMUM FLOW t=PERCOLATION RATE = 27 min./in. 675 5- = 702 SF' 3, CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING, 6. INSTALL RISERS AS NECESSARY TO BRING WITHIN ONE—HALF FOOT OF FINAL GRADE 7. LOCATIONS OF ALL COMPONENTS MAY BE AS ALL MINIMUM DISTANCES AND SLOPES ALL ACCESS POINTS TO OR HIGHER FOR INSPECTION WELLS. VARIED AS NECESSARY AS LONG MEET THOSE REQUIRED. �.-�-✓ J�,�,��y�ry [' �. ice,% / f c D(7 C7 r 5630 ----- 5 /3 Cr 26 LF OF 4" PVC —PROPOSED WAREHOUSE & OFFICE PROPOSED TRUCKWASH & BARN 1,500 GALLON SEPTIC TANK WITH BAFFLE 5 ) 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9, SOILS AND PERCOLATION INFORMATION PROVIDED BY H,P GEOTECH, INC., JOB NO. 105 694, DATED AUGUST 31, 2005. 10. 11H15 DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM CLIENT, 13. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 14, THIS SYSTEM IS DESIGNED FOR TYPICAL DOMESTIC WASTES ONLY. THE OWNER IS RESPONSIBLE FOR TIGHT PLUMBING FIXTURES. I.E. HISSING TOILETS AND RUNNING WATER IS NOT ACCEPTABLE AND MAY OVERLOAD THE 15. HIGH COUNTRY ENGINEERING RECOMMENDS CONCRETE SEPTIC TANKS OR FIBERGLASS EQUIVALENT. 16, THE ISDS SHALL BE LOCATED MORE THAN 100' FROM ALL EXISTING WELLS. 17. CONTRACTOR TO VERIFY SETBACK. REMOVABLE CAP 4 — 1/2"0 HOLES SOLID CAP FOR — SUPPORT @ BOTTOM OF TRENCH OR BED (BOTTOM OF SAND) SCHEDULE 40 PVC COUPLING PERFORATED PIPE WRAPPED WITH FILTER FABRIC COMBINATION AIR VENT & INSPECTION WELL DETAIL N.T.S. Cp 9,c9)(--cf -64.0 yr f PROPOSED BED SYSTE 44, .....,44016cri'4P• s'„ moi.. 162 LF OF 4" PVC 56' RETENTION POND GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. TABLE II TABLE OF MINIMUM HORIZONTAL DISTANCES IN FEET BETWEEN COMPONENTS OF A SEWAGE DISPOSAL SYSTEM AND PERTINENT PHYSICAL FEATURES Sip r T K RECORD DRAWING 5/30/07 THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS, WHILE THIS INFORMATION 15 BELIEVED TO BE RELIABLE, THE ENGINEER 15 NOT RESPONSIBLE FOR ITS ACCURACY, NOR FOR ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT AS A RESULT. REMOVABLE PVC CAP— INSTALL MARKER IF CAP IS TO BE BURIED FINISH GRADE 4' SEWER LINE A 44' GLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. EDGE OF GRAVEL INSTALL INSPECTION WELL. INSTALL INS19ECTION WELL 3' MAX. A BACKFILL —I' MIN. BED PLAN N.T.5, DRAINAGE TRENCH AROUND— HIGH SIDES OF BED —INSPECTION WELL WITH AIR TIGHT CAP FILTER FABRIC `y Cit_ Q'7' 00000 00 3, 4.5' - PERFORATED 1 1/2" SCREENED ROCK) 4"0 PIPE (TYP.) -24/ Or) �•o 00 0 00 SECTION A -A N.T.S. " (TYP.) i ti 00 w u 0. 1-- 0 CV Zu (:)? c -ix 0 ° pLif Cn0 Z , ¢0� ri. V I..1 z 2 W W z w z 0 3 1�1 0 03 U O R zrc L9■ W e LLi 2i I: Wf ct 0 W ,J dcc U PROD] 2061' IS Spring, Wells, Suction Lines Drinking Water Supply Line (1) Drinking Water Supply Cistern Dwelling Occupied Building Property Lines, drain tides, Piped, Lined or IntermittentCourse, Irrigation Ditch Lake, Water Irrigation Ditch or Stream Dry Gulches Septic Tank Absorption Trench, Seepage Bed, Sand Filter, Sub -surface 25 25 20 10 6 Dispersal System or 100 50) 25) Orywetl Seepage Pit 100 (2) 50 25 20 25 (2) 50 (2) 25 6 Lined Evaportranspiration Field or Lined 60 10 25 15 10 25 10 5 Wastewater Pool Unlined or Partially Lined Evapotranspiration System Wastewater 25 25 15 1t? 25 15 10 Pond, or Surface 100 Disposal System Other than Aerosol Lined Sand Fitter 60 10 25 15 - 10 I 25 10 _ 5 Unlined Sand in 5011 With a Perc Rate Slower than 60 minutes per inch (2) 100 25 25 15 10 25 15 10 Dispersal System Using (2) (2) (2) Aerosol Method 100 10 50 125 10 25 10 10 Vault Privy 50 10 25 15 10 25 10 - Septic Tanks, Treatment Plants, 50 10 25 5 10 50 10 - Dosing Tanks, Vaults Building Sewer or 50 10 25 0 10 50 10 - Effluent Lines (1) Sip r T K RECORD DRAWING 5/30/07 THIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS, WHILE THIS INFORMATION 15 BELIEVED TO BE RELIABLE, THE ENGINEER 15 NOT RESPONSIBLE FOR ITS ACCURACY, NOR FOR ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT AS A RESULT. REMOVABLE PVC CAP— INSTALL MARKER IF CAP IS TO BE BURIED FINISH GRADE 4' SEWER LINE A 44' GLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. EDGE OF GRAVEL INSTALL INSPECTION WELL. INSTALL INS19ECTION WELL 3' MAX. A BACKFILL —I' MIN. BED PLAN N.T.5, DRAINAGE TRENCH AROUND— HIGH SIDES OF BED —INSPECTION WELL WITH AIR TIGHT CAP FILTER FABRIC `y Cit_ Q'7' 00000 00 3, 4.5' - PERFORATED 1 1/2" SCREENED ROCK) 4"0 PIPE (TYP.) -24/ Or) �•o 00 0 00 SECTION A -A N.T.S. " (TYP.) i ti 00 w u 0. 1-- 0 CV Zu (:)? c -ix 0 ° pLif Cn0 Z , ¢0� ri. V I..1 z 2 W W z w z 0 3 1�1 0 03 U O R zrc L9■ W e LLi 2i I: Wf ct 0 W ,J dcc U PROD] 2061' IS