GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 4 22 6
108 Eighth Street, Suite 201
Glenwood Springs, Coloradof 81601
Phone (970) 945-8212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Owner's Namel tY - r S4-111 p. -n Present Address
l moi. 11 -
System Location
Assessor's Parcel No.
This does not constitute
a building or use permit.
5 / PhoneJCl _ a� INVz _
tit
Legal Description of Assessor's Parcel No Z--1 - t - .51D2--- C) Q - JQ 9
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other)
Required Absorption Area - See Attached
Special Setback Requirements:
Date Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
Septic Tank Capacity
Septic Tank Manufacturer or Trade Name
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Adequate compliance with County and State regulations/requirements
Other /} %/f� �' �/ �y�
Date a3 _ Inspector I 64,1)§,a f . %t /Rf -
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE .31a. -C -!/' D
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER Steven and Cynthia Tanis
ADDRESS P 0 Box 551 Rifle, CO 81650
PHONE 379-0365 or 625-8032
CONTRACTOR
Tapestry Builders
ADDRESS P 0 Box 6065 Battlement Mesa 81636 PHONE 285-0398 or 250-3449
PERMIT REQUEST FOR ( ) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town Rifle Size of Lot
Legal Description or Address Parcel 3
WASTES TYPE:
11.4 acres
McKee Subdivision Exemption
(xQ DWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER -DESCRIBE
BUILDING OR SERVICE TYPE:
Number of Bedrooms 3 Number of Persons
(X) Garbage Grinder (x) Automatic Washer (X) Dishwasher
SOURCE AND TYPE OF WATER SUPPLY: ( ) WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
2
A site plan is required to be submitted that indicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System (septic tank & disposal field) to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
2
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
SEPTIC TANK
VAULT PRIVY
PIT PRIVY
CHEMICAL TOILET(
FINAL DISPOSAL BY:
ABSORPTION TRENCH, BED OR PIT
UNDERGROUND DISPERSAL
ABOVE GROUND DISPERSAL
OTHER -DESCRIBE
AERATION PLANT
COMPOSTING TOILET
INCINERATION TOILET
OTHER -DESCRIBE
VAULT
RECYCLING, POTABLE USE
RECYCLING, OTHER USE
( ) EVAPOTRANSPIRATION
( ) SAND FILTER
( ) WASTEWATER POND
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? ti
PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the
Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole No. 3
Minutes per inch in hole No. 2 Minutes per inch in hole No.
Name, address and telephone of RPE who made soil absorption tests:
Name, address and telephone of RPE responsible for design of the system:
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and famished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and ;,, egal action for perjury as provided by law.
Signed
Date
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
7
T -MANIFOLD Distribution scheme
for 2 Trench system layout.
The manifold is to be level at
each T Group, to promote even
fluid ftod to the trenches.
OUTFALL LINE - 4'0 Standard PVC Pipe
Not Perforated and Minimize Pipe Bends.
Min, Grade - QRZ Max, Grade - L•FG
6' Minimum
SEPTIC TANK to FIELD
10' Minimum
HOUSE to SEPTIC TANK
PLOT PLAN
RESIDENCE
Living Area 2944 sq.ft.
HAS NOT BEEN PREPARED.
Drawing to be
determined.
Reissued When Plot layout is
Mln. 71'
ran!
an!_
=PROPOSED FIELD
I REPAIR AREA
e
r N
PRECAST SEPTIC TANK \ Cap the ends of
all distribution pipes.
1000 GAL, CAPACITY, n n.
4'0 PVC DISTRIBUTION PIPE
Must have 2' of Gravel Cover.
ORIGINAL
GROUND SURFACE -
3 min
FILTER FABRIC for SEPARATION.
Non -Woven, minimum Grab Strength of 120 lbs.
such as Amoco 4547, Contech C-5ONW or Miraf 1 140N.
12' Thick 'TOPSOIL'
Do not tightly compact,
Plant with grass, lightly irrigate.
3 min
-j„ 1'ORIGINAL
GROUND SURFACE
Each Trench to be 36' wide,
30' deep and 71' long.
3 3 6'
3 3
FREE WATER TABLE a eater Than 10 feet, 6-21-2006
SPECIFICATIONS:
- Traffic compact the trench gravel & imported silty sand to at least 8596 of Maximum Standard Proctor, ASTM D-698
or 'water settle' the sands, prior to placing the screened grovel and distribution piping.
- Bottom of trenches to be graded to 0.04%, away from the distribution pipe.
- Soil type & conditions must be the same across the trenches and is to be confirmed by the Design Engineer.
- Do not compact or smear the native soils in the trenches during the excavation and installation process.
- Outfall lines from the house and the septic tank to be 4" dia. PVC.
- Perforated pipes to be 4" dia. and placed with the perforations down (5 & 7 o'clock positions).
- Sand Filter to be a Clean, Coarse Sand, Effective Size between 0.25 & 0.6 mm & Cu = 4.0 or less.
- Screened/Washed Gravel to be placed around the Piping, Minimum 2" cover on Sides and Base.
- Cover the Sand Bed & Gravel with Filter Fabric, Nonwoven, min. Grab Strength of 120 lbs.
Use Amoco 4547, Contech C-50NW, Mirafi 140N, or equal.
- System to be inspected by Design Engineer at:
1) bottom excavation, 2) bottom sand, gravel & pipe in-place, 3) silty sand in-place & 4) final.
- Final Surface to drain water off and away from the mound/bed/trench area.
- Gravel and silty sand to be graded to meet the following criteria:
Screened or Washed Gravel Silty Sand Suggested, Others may Work,.
Sieve 3/4" 100% passing Sieve 1/2" 100% passing
#4 1% passing #4 7096 - 100%
#10 20%-60%
#40 8%-30%
#100 2%-20%
#200 0 % - 696
DATA:
- Building 3 Bedrooms @ 150gal/day/bdrm = 450 gal/day
AVERAGE SEWAGE FLOW = 450 gal/day
1.5 S.F. for MAXIMUM SEWAGE FLOW = 675 gal/day
Increase Area - washing machine (40 %) = 180 gal/day
& garbage disposal (20 %) = 90 gal/day
MAXIMUM FLOW for Design = 945 gal/day
- Septic Tank 1.25 X 675 gal/day = 844 gal/day
Septic Tank to be 1000 gal. capacity, min.
- For Design, Use PERCOLATION RATE of 5 min/inch
Design will Require a 24" Thick Sand Filter Bed Beneath the
Piping and The Screened/Washed Rock Pipe Cover.
- Absorption Area A=(945 X 2.236)/5 = 423 sq.ft.
use 2 - 3 ft. wide trenches (422/3)/2 = 71 ft/trench
ENGINEERS' CERTIFICATE:
I HEREBY CERTIFY THAT THIS
SEWAGE5F-WALE_EIELLLQUI.21 WAS
PREPARED BY ME or UNDER
MY DIRECT SUPERVISION.
By.
"
N:
30590
EDWARD M. MORRIS, Registered Professional Engineer
State of Colorado - Number 30590
SEWAGE FIELD DESIGN — TANIS RESIDENCE
Parcel 3, McKEE Sub. 317 CR, RIFLE, COLO.
TAPESTRY CONSTRUCTION, Battlement Mesa, CO.
GRAND
JUNCTION
LINCOLN
DeVORE
1441 MOTOR STREET
GRAND JCT., COLORADO
970-242-8968 (fax 970-242-1561)
•
92503 -GJ
DRAWN er: E. M. MORRIS
SCAU:
PLAN - 1"=40'
SR EE1 6
1
DAT[
8-8-2006
a
ED ar.E. M. MORRIS
FlRE
925031S0S
REV.
May 25 07 04:03p Witt/Tapestry 9702857596 p.2
p.1
May 25 07 03:11p 6 .1
Lincoln-DeVore Inc. (9701 242-1551
GRANT) .1UUNCTI0N
LINCOLN - 1)cVOIt1L, Inc.
GK(rro l IN I( 411. EN( 1 NEEI4? • 11K(11,11G:1M.:
I .1.11 .71oe)/- SI.
/rind Jun et in*. (A 7 R I SDS
May 25, 2007
Tapestry Builders
P.O. Box 6065
Battlement Mesa, CO 81636
Rc: Residential Sewage Disposal System (ISM)
Tanis Residence, 410 County Road 317, Rifle, CO
TE1.: 1971)1 >L' WHOt
t1tX: 19701 ].I2-151.1
Gentlemen:
Pcrsannel of Grand Junction Lincoln DcVore observed the mostly constructed but not backfilled Individual
Sewage Disposal System at the above -referenced site on October 16, 2006. The system was observed
utilizing the sewage field design prepared by Grand Junction Lioaeoln DeVore, Job #92503-Gi, dated August
8, 2006. The excavation for the piping and tranches encountered silty sands with gravels. and some sandy
clays, similar to those described in tht Report of Subsurface Soils Exploration and the soils that were tested
for a soil percolation rate. The soils in lite bottom of the trenches were somewhat sandier, containing less
clay, than those described in the soil profile log for soil percolation teeing at this depth. The soils were
observed to be slightly loosened by thee xeavation process but were not "smeared" or excessively compacted,
neither on the base nor on the trench sides.
The sou Is observed during our observation on October 16,2006 appeared to fit the design parameters and our
findings during the ensile percolation testing, Basal upon aur observations, no modifications to the sewage
Geld design performed by Grand Junction Lincoln DeVore are required as of the date of our observations.
It is believed that all pertinent points have been addiesxed. If any farther questions arise regarding this
project, or if we can be of any further assistance, please do not hesitate to contact this office at any time.
Respectfully submitted,
GRAND JUNCTION
LINCOLN DeVORE, INC.
by: Edward M. ams. P.
Principal Engineer
GJLD Mb No. 92503•G I