Loading...
HomeMy WebLinkAboutApplication.pdfGARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8" Street, Suite 401, Glenwood Springs, CO 81601 PPhonee:: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 Permit No: 160& Parcel/Schedule No: -1...1-u) W/z3 PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. r(911j." I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): eil(-4' 1 ° ')\ 1 3 I X518.5 ',MU t]uuICSS: 1"4 G2 137 1,JCO 2S SI&OI 1 Lot No: Block No: Subd. / Exemption: 2 Owner:f''(� •NF -V -'N 1L1i),,1 Address --7 1.?4B �� 1 / ,j �7 Ph:9Tc "�ZIG;Z/ ^� 3f*- 374 / 3 Contractor wr� -C SS 9K-04- Address:. z Address: p� Ph: °I 6—OCA, Ph: Lic. No. 319-03) Lic. No. 4 Archi ct/Engineer: 5 Sq. Ft. o in Sq. Ft. of Lot: d C 4C Height: No. of Floors: ti Use of Building: �i btbv , k Pfrav4,Jc, 7 I Describe Work: / C��AIN ( 114 OF /`L, l Ci Q.44A6' 4 R p(�, —mow S Class of Work: IN New Alteration Remove U Addition J Move 9 10 Garage: ❑ Single VI- x. Double Carport: �(� ❑ Single �)`' ❑ Double Ali/A_ Driveway Permit ❑ On -Site Sewage / V �� N/�" Disposal Site Plan 11 Valuation of Work: $ Adjusted Valuations: S C, 12 Special Conditions: Fee: 02k'i»/ -� // O' Permit Fee: 9%(.• 15— rISSUED NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUEDBY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLE1J;D WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. P' Plan Check 7 Z2.3 1 ....)...4444,,,,,— Total Fee: J 3 3 '7 e� [3 Dated Permit Issued: Cis pq O) OCC Gro p: /` Const. Type: Zoning: Setbacks: Manu. Home: AllAllAPP ISDS No. & Fee: SIGNATURE OF OWNER "" DE• DATE % / // DAT _ 7 /2 04 BLDG :• %EFT PLNG. APPROVAL DATE PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. r(911j." I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): eil(-4' 1 ° ')\ 1 3 I X518.5 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupanc Certificate of Occupancy for the dwelling under building permit # Signa Bpapplicationfeb2006 Date he issuance of a VALUATION/FEE DETERMINATION Applicant %Ccs 6/ nS,Or Address /✓4f $ CA Date $^Zs-p(v Subdivision --- Lot/Block Contractor All 15'474 Crny4• Finished4biviosizzo,S rai Main 4s l 0 X -vet =. {,,e—J4/ 5W 0, 01) Upper Lower Other Total Square Feet Valuation Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: gln xr5°: /� 520. Valuation Crawl Space: Valuation Decks/Patios: Covered Valuation Open Valuation Total Valuation / 26,4' y/ 60 027 A ®, (/� GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the enyel'ope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes 2 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and thearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffs? Yes i/ Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan inclu p' building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building ction drawing include size and spacing of floor joists, wall studs, ceiling joists, roof raft s or joists or trusses? Yes 11. Does the building section drawing or other detail include the method ofpositive connection of all columns and beams? Yes 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed gra a to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat ro f? (Building height measurement usually not to exceed 25 feet) Yes 13. Does the plan in ude any stove or zero clearance fireplace planned for installation including make and mo 1 and Colorado Phase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No 15. Does the plan inc de a window schedule or other verification that egress/rescue windows from sleepin ooms and/or basements comply with the requirements of the IRC? Yes No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventila ion for all habitable rooms? Yes V No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify saf glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on t plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an app 'cation for a building permit? The building permit application will not be accepted wi ut it. Yes No 21. Will this be the only residential stry.eture on the parcel? Yes No / If no -Explain: C- t k1 iSrL c r� Cafe, l<g, r' (a (r� (t- 22. t-22. Have two (2 omplete sets of construction drawings been submitted with the application? �v'( Yes 23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes � No 24. Have you designed or had this plan designed while considering building and other construction co requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone nct? Yes No 26. Does the plan accu tely indicate what you intend to construct and what will receive a final inspection by t Garfield County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the application these changes? Yes 1 No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building perm Yes ✓ No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made fro 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 4-5003. Yes No 30. Are you aware tha questing inspections on work that is not ready or not accessible will result in a $50.1 i re -inspection fee? Yes No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of uilding? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes 1/ No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a drivew y access permit or obtain a statement from the Garfield County Road & Bridge Departm t stating one is not necessary? You can contact the Road & Bridge Department at -8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of plicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel le Number for the lot you are applying for this permit on prior to submittal of a building perTapplication? Your attention in this is appreciated. Yes c/ No 36. Do you know that the local firer ' may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Date // G Phone: '3 -- 3 `Zi ') (days); q%o - 959s - " (evenings) Project Name: F�etx. Oeln QeD 4ms'�� 2 . Project Address: s49:` C -IL A-51 tMtnAr }c1A (2G , 00 1161) Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, FPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload: 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 75PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R -Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R -values are R-19. • Basement wall R -values are R-10 below grade, R-19 above grade. • Slab perimeter R -value and depth is R- 10/36in. • Crawl space wall R -values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant /'M 41.$?9,t% Date 8 -2-5--o Building > ngineered Foundation —Driveway Permit t -/Surveyed Site Plan —Septic Permit and Setbacks G ade/Topography 30% t -Attach Residential Plan Review List c__—Minimum Application Questionnaire t, ---Subdivision Plat Notes Fire Department Review t -Valuation Determination/Fees Red Line Plans/Stamps/Sticker Mach Conditions ‘,-Application Signed lan Reviewer To Sign Application ✓Parcel/Schedule No. ///4 —40# Snowload Letter- Manf. Hms. iIs-Report GENERAL NOTES: Planning/Zoning Property Line Setbacks ,J 30ft Stream Setbacks J/AQiFlood Plain `B-uilding Height Zoning Sign -off /ii oad Impact Fees h/17 HQA%DRC Approval Grade/Topography 40% &Planning Issues �V N Subdivision Plat Notes STATE ELECTRICAL BOARD INSPECTION REPORT / CORRECTION NOTICE Date Rec. e7/'T !0 7 PERMIT #G = (O/ Contractor/Home Owner: 77L r'' 1/4-2:c Address: • TYPE OF INSPECTION: Partial Rough in Underground Final \x/ ACTION: Accepted / Rejected Remarks REINSPECTION FEE Comments or Corrections: JO -1t tc ( rx.-x 4 Inspector's Name Phone # Date i FORMS:EHINSP NOTICE. DOC STATE ELECTRICAL BOARD INSPECTION REPORT / CORRECTION NOTICE Date Rec. ,--7• ) 7 PERMIT # Contractor/Home Owner: Address: /277 • TYPE OF INSPECTION: Partial Rough in Underground Final ACTION: Accepted %c Rejected Remarks REINSPECTION FEE Comments or Corrections: Inspector's Name Phone # Date - • , • / FORMS:EBINSPNOTICE.DOC No j COS2L Assessor's Parcel No.a a f Ob —I):3 Date 9 Jg/6 C / BUILDINQ PERMIT CARD t7 Job Addres / C Rte, 13 9 2-dx ,4k in- a Ri b b 1 Owner YN )8-ki'i,c-�-e��-d -u .dress )SSE1c°Zt31 S Phone #+15"8,441 Contractors (_dY)44t u--c-iv-Address Pic • ✓S,Y Su} CS 1fb'hone #3 d'f 4 RH LH Zoning 0 INSPECTIONS Setbacks: Front UQ -yU 15LJ Soils Test Footing q -0-1- 0 _ Foundation Q-.2.7.06- Sri Grout Underground Plumbing *Rough Plumbing A/,4 Framing l.- -7e-D6 Os.._ Insulation (2'2/ - //goofing Drywall )2-2 -°' oaO7.41 Gas Piping Rear 'Sr 06gAZ /.J? on/2/a, ='60x „0✓ Sae -a2 -/-off vine), EXTERIOR Address No. Drainage Decks -support & clearance to wood Decks -stairs & rails Exterior locks Flashing around doors & windows. Insect screens —�— INTERIOR GARAGE Fire wall separation Service doors -11" min. — Door (20 min.) wlauto closer -13/4" min. Mech. equip. 16" above floor Noopening into sleeping area BASEMENT -CRAWL AREA Access Insulation HeadrOomlStalrs Ventilation — Weatherproofing Mechanical Electrical Rough (State) /2- ?VG tiF Electrical Final (State) fJ91l -Final 8/07 /Checklist Completed'? Certificate Occupancy # Date Nl4 Septic System # Date Final Other NOTES FINAL CHECKLIST MECHANICAL ROOM Boiler Hot water F.A. gas/oiler----- Floor drain_------ _ Clearances--- Air con. system _ Hot water heater Combustion air Gaspiping, valves LPG Drain FIREPLACEISTOVE _ Clearance to combustibles_ _ Termination of chimney Combustion air _ Hearth (12" or 20" on sides) Glass doors Certified by:� REMARKS (continue on back) STAIRWAYS • _ 'Headroom (6'6") _ Railing & guardrails _ Width---� _ Rise & run KITCHEN Clearance above grill _ Exhaust fan _--- _ Broiler exhaust (1 hr. chase) BEDROOMS Egress _------ Smoke detector BATHROOMS Exhaust fan— Shatterproof glass OTHER Nit. • S Utldl INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS i BUILDING PERMIT GGARFIELD COUNTY, COLORADO Date IssueJt�.:lf.�.'.A zoned Area Permit No /0099 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building InspectororandmeIMMEDIATELY BECOME NULL AND VOID. Use ll Addre Legal Description Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing 9.Z/.06 Sm_ Driveway Foundation 9- a7.-0,6 4 Underground Plumbio —/-67Insulation rz -z1 Rough Plumbing ,y�q Drywa11 c,12 --M- toi9m�, / /9r�; Chimney & Vent NA9 Electric Fina (by State Inspector) Gas Piping A//A Final g) -c27 %j /dt Electric Rough (By State Inspector) Septic Final Framing ), - fg 96,Q94..- (To include Roof in place and Windows and Doors installed). Notes* ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 108 8th Street Glenwood Springs, Colorado APPROVEDDO NOT DESTROY THIS CARD Date9-3'n(IBy F5 FE IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property _Search 1 Assessor Subset Query 1 Assessor Sales Search Clerk .& Recorderr_ Reception Search Basic Building_ Characteristics 1 Tax Information Parcel Detail 1 Value Detail 1 Sales Detail 1 Residential/Commercial Improvement Detail Land Detail 1 Photographs Tax Area Account Number Parcel Number Mill Levy 004 R040334 212324300123 63.403 Owner Name and Mailing Address ROBINSON, RICHARD BRUCE & DAYLE V. 1548 COUNTY ROAD 137 GLENWOOD SPGS, CO 81601-9767 Legal Description SECT,TWN,RNG:24-5-90 DESC: TR IN SW COMM. AT W1/4 COR. PRE:R040313 BK:0789 PG:0798 BK:0789 PG:0795 BK:1767 PG:990 RECPT:691371 BK:1628 PG:205 RECPT:661067 BK:1411 PG:253 RECPT:615497 BK:1238 PG:859 RECPT:577861 BK:0983 PG:0936 BK:0983 PG:0933 BK:0938 PG:0689 BK:0847 PG:0424 BK:0787 PG:0460 Location Physical Address: Subdivision: Land Acres: Land Sq Ft: 1548 137 COUNTY RD GLENWOOD SPRINGS 38.71 0 II http://www. earcoact.com/assessor/parcel.asn?ParcelNumher=212324300123 7/14/2006 Parcel Detail Page 2 of 3 Section 11 Township II Range 24 5 90 Property Tax Valuation Information Sale Date: Sale Price: 6/27/1996 900,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 2 0 Actual Value Assessed Value Land: 3,390 980 Improvements: 523,020 50,370 Total: 526,410 51,350 Sale Date: Sale Price: 6/27/1996 900,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 2 0 httn://www.earcoact.cam/assessor/arcel.asn?ParcelNumher=212324300123 7/14/2006 Residential Building Occurrence 1 Characteristics TOTAL HEATED AREA: 2,797 ABSTRACT CODE: FARM/RANCH RESIDENCE - ARCHITECTURAL STYLE: 1 -STORY EXTERIOR WALL: LOG ROOF COVER: PREFAB MET ROOF STRUCTURE: GABLE INTERIOR WALL: DRYWALL FLOOR: HARD TILE FLOOR: CARPET HEATING FUEL: GAS HEATING TYPE: HT WTR RAD STORIES: STORIES 1.0 BATHS: 3.2 ROOMS: 7 UNITS: 1 BEDROOMS: 3 YEAR BUILT: 1991 httn://www.earcoact.cam/assessor/arcel.asn?ParcelNumher=212324300123 7/14/2006 Parcel Detail Page 3 of 3 Tax Information Tax Year Transaction Type Amount 2005 Tax Payment: Whole ($3,255.74) 2005 Tax Amount $3,255.74 2004 Tax Payment: Whole ($3,251.42) 2004 Tax Amount $3,251.42 2003 Tax Payment: Whole ($2,864.32) 2003 Tax Amount $2,864.32 2002 Tax Payment: Whole ($5,460.76) 2002 Tax Amount $5,460.76 2001 Tax Payment: Second Half ($2,747.93) 2001 Tax Payment: First Half ($2,747.93) 2001 Tax Amount $5,495.86 2000 Tax Payment: Second Half ($2,204.12) 2000 Tax Payment: First Half ($2,204.12) 2000 Tax Amount $4,408.24 1999 Tax Payment: Second Half ($2,032.26) 1999 Tax Payment: First Half ($2,032.26) 1999 Tax Amount $4,064.52 Top of Page Assessor Database Search Options Treasurer Database Search Options Clerk & Recorder Database Search.. Options Garfield County Home Page The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 - 2006 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www.earcoact.com/assessor/parcel.asv?ParcelNumber=212324300123 7/14/2006