HomeMy WebLinkAboutPlans.pdfCONDITIONS OF PERMIT
BLM F-7-14-3287
Meeney Residence
46007 Hwy 6&24
GWS, Colorado
1) SEE PLAN ATTACHMENTS FOR BUILDING REQUIREMENTS .
2) INSPECTORS DISCRETION TO REQUIRE ENGINEER APPROVAL OF EXIST ING FOOTINGS IF
DAMAGED BY FIRE OR IF BEARING SOIL IS DISTURBED .
3) PLUMBING/GAS PIPING MUST BE PERFORMED BY A COLORADO LICENSED PLUMBER .
4) ELECTRICAL WORK MUST BE PERFORMED BY A COLORADO LICENSED ELECTRICIAN .
5) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION .
6) VERIFY C.D.0 .H. INSTALLATION INSIGNIA IS AFFIXED PRIOR TO CO/F INAL INSPECTION .
7) A CURRENT PROPERTY SURVEY SHOWING ALL STRUCTURES AND IMPROVEMENTS,
SEALED BY A COLORADO LICENSED SURVEYOR , IS REQUIRED FOR CO/FINAL INSPECTION .
8) DEBRIS MUST BE REMOVED FROM PROPERTY PRIOR TO CO/FINAL INSPECTION , TO
INCLUDE , BUT NOT LIMITED TO, MISCELLANEOUS TRASH , VEH ICLES, TIRES, 5 TH WHEEL
TRAILER , AND FALLEN TREE . THISTLES MUST BE CUT DOWN AND REMOVED . BUILDING
OFFICIAL WILL INSPECT REMOVAL OF BEBRIS PRIOR TO CO/FINAL INSPECTION .
5°Be. &~~M~ of' h;-m1/ /OJL
gi£l~t4-/ ~U/l'ePH~~.
/_ ~'
c.o.o* f/. /1t1/A-l/4-fl//J11Jt?1f JI/~
MP1 I ~e /1-#1 r-e rl 17~1()/l lo
co//'/14/fl /H5j/'~c/;t!J'1.
~ ell
M ~ ~
~ ~ I
""" c.tl :E
~ ta ca >
' !:""-= "' = c ta ~ ..i:r
·c l!!J
0 cu
E c.t:J :f! en m -= e f ~ .a
CJ
m RI
c '"$ m c m RI
::::E :E
DRAWING INDEX WINDOW /DOOR SCl-IEDULE SYMBOLS ELECTRIC AL SC ~ED UL E
PAGE NO . DESCRIPTION DESCRIPTION LI Gl-ff VENT (h CIRll DESCRIPT ION BREAKER VOLTS WI RE W-2 24 x 27 l-IORIZONTAL SLIDER 2 .83 l.C>I Q -CFL LIG~T db -IS AMP RECEPT. -GFC I RECEPTACLE I GENERAL AND ELECTRICAL NOT ES W-3 4"' x 8 l-IORIZONTAL SLIDER 1.10 .7S (IS OR 20 AMP) I FURNACE (GAS) IS 120 14/2
2 FLOOR PLAN w-s 40 x 36 l-IORIZONTAL SLIDE R 7.4"1 4 .06 <9-EX~AUST FAN b dlh 2 GROUND FAULT CIRCUIT 20 120 12/2
W-10 10 x 74 SL FI XED SAFE TY GLAZED He> 0.0 -20 AMP RECEPT. -240 VOL T RECEPTACLE 3 GENERAL LIGl-I TING (AFCI) IS 120 14/2 3 ELECTRICAL W-14 14 x 14 FIXED 0."12 0 .0
4 EXT ER IOR EL EVATION W-33 36 x IS FI XED 2.8"1 0 .0 @ -SMOKE ALARM $ -WALL SW ITCl-I I -- ---, _ FL UORESCENT 4 GENERAL LIGl-ITING (AFCI) IS 120 14/2
W-34 36 x S8 VERTICAL SLI DER 11.l>S l>.l"I l_!~E~~-J LIGl-IT s GENERAL LIGl-ITING (AFCI) IS 120 14/2 s FOUNDAT ION LAYOUT W-3S 30 x S8 VERTICAL SLI DER "l.48 S.08 " PORT ABLE APPLIANCES 20 120 12/2
(, PL UMB ING-WATER W-40 40 x 18 FIXED FUL L EYEBROW 3.27 1.86 E!l -M.ttlN ELECTRICAL dJ>MT -l-IEAT TAPE RECEPT. db -ARCl-I FAU LT RECEPTACLE 7 PORT ABLE APPLIANCES 20 120 12/2
W-S2 46 x S8 VERTICAL SLI DER IS .27 8.04 PANEL BOX(200 AMP) (IS OR 20 AMP)
8 PORT ABLE APP LIANCES ( AFC I) 20 120 12/2 7 PLUMBING-DvN W-127 30 x 12 FIXED 77 0.0 Q-WIRE 4 BRACE CD -Tl-IERMOSTA T db GD-GARBAGE DISPOSAL
8 PLUMBING-GAS W-125 30 x IS FIXED 2.37 0.0 LOCATED PER CODE W!l q FREEZER (GFC I) 20 120 12/2
W-12'1 4C> x IS FIXED 3.7S 0 .0 10 WA~E R 20 120 12/2 q FLOOR FRAMING W-130 36 x 12 FIXED 2 .1"1 0.0 ~-COMM UNICATI ON .... -RETURN AIR ~ -SMOKE /CARBO N ALARM 11 D I S~WASl-I ER IS 120 14/2
10 ROOF PLAN 4 AIR RETURN W-136 36 x 80 VERTICAL SLIDER IC>.10 6 .1"1 JACK
PORT ABLE APP LI ANCES Q -SOLAR T UBE Q -JUNCTION BOX Q -RECESSED LIGl-IT 12 20 120 12/2 W-141 40 x IS FIXED 3.23 0.0 OVEN CS -BL CS FOR BLANKET INSULATION W-IS6 46 x 80 VERT ICAL SLIDER 21.04 8.04 CAN 13 40 240 6/3
·>
W-IS6 34 x 34 VERTICAL SLI DER 8 .0 4.0 ~ -WINDOW t t 1-l ~ -4 " x 10' FLOOR 14 DRIER 30 240 10/3
W-le>O 40 x 40 l-IORIZONTAL SLIDER 8.33 4.S DOOR DESIGNAT ION -OSE BIBB REGISTER IS WAT ER l-I EATER 2S 240 1012
W-AB 40 x 40 FIXED 8.33 0.0 E -EGRESS WINDOW @)-Sl-IEAR WALL ~ -2 1 x 12" FLOOR 16 COOK TOP 40 240 6/3 W-161 72 x S8 l-I ORI ZONTAL SLIDER 24 ."I 13 .02 SG -SAFETY GLAZE D 17 A/C CONNECT ION 30/W 240 {,/2 W-162 72 x IC> FIXED FULL EYEBROW S."16 0.0 REG ISTER
W-163 72 x 10 FI XED 0.0 16 EVAPO RATOR COOLER IS 120 14/2
W-23"1 16 x 40 FULL EIEBROW/ XOX 14 .84 3.Sl> ELECTRICAL NOTES: l"I FURNACE (ELECTRIC) 30/{,0 240 {,/2
D-1 % x 80 FRONT ENTRY DOOR 0.0 20.0 RECEPTACLE& IN DAMP OR ll.ET LOCAT ION& MU &T BE Ll&T ED WE ATHER RE&l&TANT. {ll.RJ 20 RANGE 40 240 8/3
D-2 36 x 80 ENTRI DOOR 0 .0 20.0 ALL IS I 20 AMP RE CEPTACL E& ARE TAM PER RE &l&TANT 21 TRASl-I COM PACTOR IS 120 14/2 D-3 24 x 72 W/1-1 DOOR 0.0 0.0
D-4 36 x 80 FI RE DOOR STEEL 0.0 20.0 ALL CIRCU IT& Tl-IAT ARE NOT GFCI PROTEC TED ARE AFC I PROTECTED 22 MICROWAV E IS 120 14/2
D-e> 74 x 80 DBLE . ATRIUM DOOR 1"1.2 40.0 &MOKE AND/OR CARBON MONOXIDE ALARM& &l-IALL NOT BE IN&TALL ED ON A CIRCUIT 23 GENERAL LIGl-IT ING (AFC I) IS 120 14/2 DEDICATED ONL Y FOR SMOKE AN D/OR CARBON MONOXIDE ALARMS. D-7 74 x 80 FRENCl-I DOOR 1"1.2 40.0 AN UP-TO-DATE, ACCURATE, AND LEGIBLE CIRCUIT DIRECTORY APPL IE& TO Tl-IE Tl-IE PANEL BOARD 24 GENERAL LI Gl-IT ING (AFC I) IS 120 14/2
D-8 72 x 80 SLIDING GLA SS DOOR 33 .37 ll>.3 AND WI LL BE DONE IN me FACTORY 2S GENERAL LI Gl-IT ING (AFC I) IS 120 14/2 D-16 32 x 80 ENTRI DOOR 0.0 0.0
D-17 36 x 80 SINGLE AT RIUM DOOR 8.4 20.0 26 GENERAL LI Gl-IT ING (AFCI) IS 120 14/2
27 GENERAL LI Gl-IT ING ( AFCI ) IS 120 14/2
State of Colorado 28 GENER AL LI Gl-ITI NG (AFCI ) IS 120 14/2
2'I GENERAL LI Gl-IT ING (AFC I) IS 120 14/2
Division of Housing 30 JACUZZ I BA n1 TUB PUMP IS 120 12/2
31 JACUZZ I BATl-I T UB l-I EATE R IS 120 12/2
FLOOR PLAN : GENERAL NOTES May 6 , 2014 32 FURNACE (GAS) IS 120 14/2
33 WATER l-IEATER 2S 240 1012
I. DESIGN COMPL IES II.HI-I 2011 IRC. 2011 NEC. 2~ IECC 34 A/C CONNECT ION 3 0/{,0 240 {,/2
2. DESIGN LOAD&: ~!'SE ~P£.! 3S FURNACE (ELECTR IC) 30/{,0 240 (:,/2
3. IS P&F DEAD LOAD, FLOOR LIVE LOAD , 40 P&F 36 UTILI T Y ROCIM IS 120 14/2 l-IORIZON TAL WIND LOAD -~ MPl-I EXPOSURE C. (3 SEC GUSTS) % SMOK E ALARM t COIA (AFCI) IS 120 14/3 4. OCCUPANCY , SINGL E FAMILY DURLING. SEISMIC ZONE A, B, C
S. PL AN MAY BE BUILT REVER&ED . 37 EXTER IOR GFC l(WEATl-IE R-RESISTANT 20 120 12/2
E>. WINDOJ.6 AND/OR DOOR& MAY BE RELOCATED WITl-llN A ROOM. ~~CL!J 36 GENERAL LIGHT ING (AFCI) IS 120 14/2
1. 2 x E> EXT ER IOR WALL FRAMING. 3q GENERAL LIGHT ING (AFC I) IS 120 14/2
8. t1ARRIAGE WALLS ARE 4" THICK• ALL OTHER INTERIOR WALL& ARE 4" THICK • UNLESS NOTED 40 GENERAL LIGHT ING (AFC I) IS 120 14/2 OTl-IERW15E. «NOM INAL)
'3. RANGE HOOD I& 100 CA1 AND I& EXHAU&TED TO EXTERIOR 4 1 PORTABLE APPLIANCES IS 120 14/2
10. BATl-IROOM VENT FAN& ARE DUCTED TO EXTERIOR 42 PORTA BLE APPL IANCES IS 120 14/2
It IF HOME I& PLACED ON &ITE Wl-IERE ANY WINDOW SILL I& LE&& THAN 24 " A60VE FINl&HED FLOOR AND PLANS APPROVED 12 ' OR GREATER A60VE Tl-IE EXTERIOR 6RADE , A WINDOW GUARD MUST BE IN&TALLED THAT COMPLIE& Subject to fie ld inspection P l-IY S ICAL ADDRESS WITH A&TM F200<:, OR A&TM F20'30.
12. Wl-IEN THERE I& 30 INCHES Cf UNOB&TRUCTED HEADROOM IN THE ATTIC &PACE, A ROUGl-l-FRAMED
STREET' 46007 I-IHI 6 ond 24 OPENING Cf 22"x30' &HALL BE FROVIDED.
LOCATla-1 a.I LQT : CITY : GLENWOOD SPR INGS STATE: CO
MINll1J1 DISTANCE Cf S' FROM BU ILDING TO PROFERTI AND ADJACENT BUILDING&. ZIP CODE, 61(:,01
L~Atla-1 ~ LQT: 513142 NOTES:
&ITE SPECIFIC FLOOD LOAD& l-IAVE NOT BEEN ASSES&ED IN Tl-I I& DESlc.N PACKAGE. FOR BUILDING& Garfield Covnty
LOCATED ON FLOOD HAZARD AREAS, AS E&TAB LISl-IED N SECTION R3012.4 SHOULD BE DE&lc.NED AND
CON&TRUCTED IN ACCORDAl-tE WITH SECTION R323 (2012 IRC)
( REV I S ION & le'T'I DATE I C:.ENERAL NO TE & DRAWIN:3 TITLE PRODUCT: SERIE&, I MODEL NO. K3076A
~ 5 ,\fNGINEERi~\~~l~~~~ORDERS\CO IRC Kovi'A MODULAR AL BUQU ERQU E KARSTEN MEENEY GENER AL 4 SQ. FT, ORAUIN6 FILE n-fOR"\ATION:
DATE PRINTED: 4ntlU>l4 2'26 A1 PLAN APPROVAL ELECTR ICA L NO TES 2 ,280 (CO) IRC He>-., PRINTED BY: Marllnez, Rlc:Nrd PAC KAGE ORAU.N er, DATE DRAl!N: 1 ~r of 2700 Karsten cl. S.E. Alb, NM. 87102 (505) 242-5580 ph. SAYED BY: MarllnezR ---4-17 -14 10
· 0 PDF created with pdfFact ory trial version www.pdffactory.com
.,
SU/·313
32? f'l.F
WAL L ~E IGHT •l02'
l l3'M N @
Oji
~ '~
/\ 16'·0 '
n·.4• b '·&' / A I 10'·0'
SUl·31J (!iv l!X?l PLF
WAL L HE IGHT•l"2' ® ~E 00 00 2U 'MIN
n M
MASTER BEDROOM IUARDR06E LIVING ROOM
~ SQFT.•148.'.I; WALK-IN ~ SQFT.•304.10
U'·0' &'·0 ' 121 ~0·
00 ffi •60' EW
I I I
BEDROOM 112
~&afT.•14'l.11
,----..., O[ oc BEDROOM •3 ;o; ROCM &afT.•14~30
::> ~ r;:::=:
m ~ 6 _,
1 ,. ·1 112 ' 't::::::::::ll
State of Colorado
Division of Housing
May 6 , 20 14
PLANS APPROVED
Subject to field inspection
5 13 142
oc~
~--,19 =~ ~
'
f ":~~. f ,.,. . """ _ •·->w _ '~"-19_·--1-v4_· _____ _,..",,~/u·.4;14 •
!31lx4•60" GSL !31lx4•&0" GSL L SET I 'I I
<11lx4t60" GSL Sl\JD SFf STUD SFf C O ' CLOSET ,t=~~~~=;=========~~~STUD SFF;~3;=:;::~=~"'""W ALL HEl6HT •l01' WALL ME16HT •l02~·,~======~=====~~, _-;;~=====;;::::::::::====-
PANTRY'<(,__ __ ~'X~'~M~1 ',~~', 15'X'l>"LYLeM. 15'Xl&'LYLe.'V"' ~~~4~651. ~ ~CLOSET,.Jc=~• E) f'~TT~~1 ~o I 'I I I • I I I ' I l~K~
8 ~~
-
10'·1 W
',~~,',, r-~/i WAL L 11E lU~T·!02 •
D INIW-ROOM : / : 15 'Xl1' LY\. eM. ~ ~' u ~ '. f<IXf"1 SQflo\Jab~ I KI TC~E ',~,, \ -R001 SQJ=T.1 112 2 ~ ',~J\ \
I I I
'' ' I I I
I I I
II I
I I I u I
I
I
I
I
I
I
I
I
I
I
I
I
I FAM ILY ROOM BEDROOM ~4
-!-
6168
14 '·1'
x
/'"
I
ROCM SQFT.•11&.01 ~OQFT.•14?30
sephc ~l'Wtlf # '32-9 5 r;er11Je~
~1")ttn? 1f~ff# tl~11f1t~ P-f 7'R..
U'·I'>'
SUI· 3l3 SUI· JIJ
1%> FLF Q 32? F!.F
WAL L HEIGMT •l02" ~ WALL HE IGHM!'Z'
2U' MIN 213' MN
~~
laY I DATE I GENE~AL NOTE& DRAW:NG llTLE ~T: SERIES• I MODEL NO. K3076A
MODULAR ALBUQUERQUE KARSTEN MEENEY
RE Y l510N&
FLOOR PLAN SQ.FL DRAWi!-(, FILE NFORMAT IOl,
FLAN APPROVAL 2,280 (co) IRC DATE PRINTED: 4!.?ln014 2:26 Fl1
2700 Ko,.,ftn et. S.E. Alb, HM . 87102 (505) 242-5580 ph. PACKAGE DRAl!.N 6 Y: DATE DRAIJN, I &Mzl at ---4-17-14 10
PRINTED 6'1": Martinez, Rlc:/iard
SAYED 6'1": MdrlinezR
· 9 PDF created with pdfFactory trial version www.pdffactorv.com
State of Co lorado
Division of Housing
May 6, 2014
PLANS APPROVED
Subject to field i nspection
513142
----@ ----
2700 Karsten ct. S.E. Alb, HM . 87102 (505) 242-5580 ph .
®._ ______ _
DATE PRINTED : 4121ntZll4 2:26 PM
PR INTED 6Y: Mort inez, Richard
SAVED BY: Mllrt lnezR
0 PDF created with pdfFactory trial version www.pdffactory.com
~.
' \, ~ ....... ____ c.Aij
I
\
/~
I
I
I
I
I
I
I
I
',
'
\,,,"@)
,,;'
/
I
I
I
I
I
I
I
I
I
I
I
I & I
I _,
-~
,/
' ' I
I
\
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
m----"/
36
~
CO/&A
• ELECTR ICAL PERMIITING & INSPECTIONS AR E
BYTHE COLOAAOO STATE ELECTRICAL BOARD
~ ELECTR ICAL FINAL APPROVAL IS
REQU IRED AT CO /FINAL INSP ECTION
ELECTRICAL PLAN
fl<ODUCT .
ALBUQUERQUE
2,280
DRAllN 8T:
SERIE &·
KARSTEN
DATE DRA!l.N•
4-17-14
MODEL NO. K3076A
MEE NEY
(co) IRC
Sl<EE T•
3 of 10
State of Colorado
Division o f Housing
May 6 , 2014
PLA N S APPROVED
Subject to field inspection
513142
~
>-
~
==--
~I
~
~ -
-~l 9 •"-
.; ~--~ /"
-~~~ '-
-I-~"-' \
I-~ -,___ '--
I-~~ I-
I-I-
I-I-
2700 Kari ten ct. S.E. Alb, NM. 87 t 02 (505) 242-5580 ph .
1111
a aJ 1 ~~
D DI
OD
I I I J
(£!;)
I
~
~
'-
DATE PRINTED: 412112014 2:26 PM
PJ;tlNTED Bl': Mart inez, Richard
SAYED Bl': Harl lnezR
· 0 PDF created with pdfFactory trial version www.pdffactorv.com
~
-
1111111
~
1 11 1111
-
-
1 1 1 I I I I I I I I I I I I I I 111111 1 J~J
~ ~ ~ ~~ ~ I"'-"
~ ~ 0,_"~ 1 111 1 11111111 1111111 I I I I
\
FRON T SIDEWALL E EVATION
4t>8
--= -
--~ -
--~~ -.~ ~~ ~~ ~ ~ ~·~-=
~ --------7 ~ -..; ~
I I ( ' -,µJ
~~~ A.
Ill/ [D [D -1--~~ -
\I -1------
10 D _j ---
I-,_ .__ I-
DD
,_ .__ I-.__ I-
-
RE AR SIDEWALL ELE VAT ION 110 1!)
FRODUCT· &ER Eo • MODEL NO. K3076A
ALBUQUERQUE KARSTEN MEENEY
ELEVATION 2,280 (CO) I RC
DRAl!N 6Y : DATE DRAU.N: Sl<EET:
4-17-14 4 of 1 0
~~
2700 Karsten ct. S.E. Alb, Htl. 87102 (505) 242-5580 ph.
REAR ENDWALL ELEVAT ION
State of Colorado
D ivis ion of Housing
May 6 , 2014
PLANS APPROVED
Subj ect to field inspection
513142
12 !;V'"
::;:( ====:;:;:R;;:;:E=v:;;;1 ;<;:5;;;;1 ;;;:o::;;;N;;;;e~===~l::::e=Y:=:I =DA=TE::::::::;l•1------c:.;;,__;_E_N-=E::....R'--'-A'-=L;__.:..:.N ...::.o-'t-=E=--5'---------l i DRAw1~ TITLE
1 s,\ENG1NEERi~~~¢.,~1~G~~ltl[:OROCRsW 1Rc K3076A M Q DUL AR
DATE PRINTED, 4/Zlfi€114 2:26 PM
PR IN TED B'r: Martinez, Rlchlrd
SAVED B'r: MartinezR
PLAN APPROVAL
PACKAGE
· 0 PDF created with pdfFactory trial version www.pdffactorv.com
-
FRONT ENDWALL ELEVATION
&ER IE&. I MODE L NO. K3076A
KARSTEN MEENEY
PRODUCT.
ALBUQUERQUE
ELEVATION 2,280 (co) IR C
I 4s of 10
DATE DRA!lN,
4-17-14
FOU NDATION GENERAL NOTES:
-ALL DESIGN DET AI LS AND NOTES ARE SUGGESTIVE ONLY AND ARE SUBJECT TO THE JURISDICT ION OF STATE AND L<X AL CODES. Cl-IANGES MUST BE MADE ACCORDINGLY. Cetl TACT YOU R L<XAL BUILDING DEPARTMENT
FOR FROST LINE AND SOIL REOO IREMENTS, FOR VENTI LATION REOOIREMENTS SEE STATE OR L<XA L CODES,---....,..--
-rns PRINT IS A TYPICAL FOUNDATION LAYOUT ONLY AND IS NOT INTENDED FOR CONSTRUCT ION DESIGN OUNDATIOO AND FOOTINGS MUST BE DESIGNED FOR SPECIFIC l-IOME BY A REGISTERED PROFESSIONAL ENGl~EER.
-FOUNDATION CONSTRUCTION, DAMP PROOFING AND DRAINAGE MUST BE PROVIDED IN ACCORDAN CE WITH THE 20!2 IRC REOOIREMENTS.
-PLEAS E REFER TO THE FOUNDATION PACKAGE FOR ALL OTH ER INFORMATION .
-TOTAL MAT ING WAL L RIM J?ISTS BEAMS' (4) 2xl0 #2 SPF
-RIM J?IST SPLICES ' h'xh' MITEK MT20 METAL PLATE S EACH SIDE
-FACTORY SUPPLIE D FURNAC E AND DUCTS AR E DESIGNED TO SUPPLY FACTORY BUILT FLOOR S ON LY. ALL OTH ER CON DITIONED SPACES 51-jALL REQU IRE HVAC DESIGNED SUPPLIED AND INSTALLED BY OTHERS ONSITE .
-DESIGNED FOR VENTILATED CRAWLSPACE.
-ALL FOUNDAT ION AND SITE WORK TO BE PERFORMED BY A CONTRACTOR LI CENSED IN THE STATE OF CO
FOJNDATION CONSTRUCTION LOADS ARE CALCULATED WI TH '° PSF GROUND SNOW LOAD (PG)
-HOR IZONTAL WIND LOAD -IOS MPH EXPOSURE C. (3 SEC GUSTS)
-SEISM IC ZON E DESIGN C MAX.
tf'nt~ lo .U/flt d f /)h/$ .
-----------~~~--~
r -------------------------------------------------------------------------------------------------------------------------,'--~~---'"--"-
State of Colorado
Division of Housi ng
May6, 2014
PLANS A PPROVED
Subject to field inspection
51 3 142
,---------------------------------------------------------------------------------------------------------------------1
~··b'
46 '·0' ,~
b '·"'
12 '·"' ;~
'I 'I 'I 1 1 ·1
~-----~------~-----~------111-----11-----11 ---------E.3 ---------111-------~-------11-----------111-------~------i
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I _____________________________________________________________________________________________________________________ J
1-----------------------------------------------------------~~:---------------------------------------------------------r
FROD\ICT , &ERIE&,
ALBU QUERQUE KARSTEN
PIER LEG END
0 = SUPPORl UNDER llATING OPOING
• = SUP!'ORT AT w.ITING ct\UllN
~ = SUP!'ORT lNlCR MolllllG \!JU
• • PIER POROl/RECESSl:D ENTRY
0 • PIER MIN BEMI
"" • PIER i'[R!Mffi R
I MODEL No. K3076A
MEENEY ~ MODULAR
PLAN APPROVAL
PACKAGE
FOUNDATION DRAU!NG FIL E INFORMATIC)-1,
'\=~--~ 2 ,280 DATE PR IN TE D: 412 112014 2:26 PM (CO) IRC
DATE DRA'J.N, PR INTED B Y: Martinez, Rlch:lrd
2700 Karsten ct. S.E. Alb, NM. 87102 (505) 242-5580 ph . 5AVE D BY: H~r llnezR 4-17-14
· 9 PDF created with pdfFactory trial version www.pdffactorv.com
I"
PRINTED BY : Martinez, Richard
2700 Karslen cl. S.C. Alb, NII. 87102 (505) 242-5580 ph. SAVED BY: MarllneZR
0 PDF created with pdfFactory trial version www.odffactorv.com
State of Colorado
Division of Housing
v-JATER SYSTEM
----COLD HATER LINES
---------1-lOT HATER LINES
- - --OPTIONAL HATER L INES
May 6, 2014
PLANS APPROVED
Subject to field inspection
513142
-80' DEVELOPED LENG.Tl-I
-17.1 FIXTURE UNITS "' 1" INLET
-40-4'1 PSI PRESSURE RANGE
1. THIS HATER SYSTEM IS DESIGNED FOR PEX .
2. ASTM F 215q LISTED FITTING FOR PEX .
3. ALL f.IATER LINES ARE 112' UNLESS NOTED OnlERWISE.
4. ALL RISERS ARE 24' TYPICAL .
WATER ~EATER PRESSURE RELIEF VA LVE TO DRAIN
TO T~E EXTERIOR OF THE UNIT
S. TH IS DRAHING IS NOT TO SCALE.
6. ALL VALVES ARE FULL WAY VALVES. ~UT OFF
VALVES AT ALL WATER CLOSETS,LAVYS AND SINKS.
MASTER VALVE AT WATER ~EATER. (REQU IRED)
7. ANTI-SCALD PROTECTION FOR TUB/~OWERS .
&. WATER ~AMMER ARRESTORS TO BE INSTALLED AT
WA~ING MAC~INES, Dl~WA~ERS AND IC E MAKERS.
'I. ALL RESIDENTIAL ~OT WATER PIPING, INCLUDING
CIRCULATING SUPPLY AND RETURN PIPING ~ALL BE
INSULATED TO A MINIMUM R-2
All t:b#He'Cjt?>-1~ ,;HP?I
J?~""~,,n-eA ~r "" a/pr~
Vtt'/!J-tc/ /%»'1~er.
314"
5eph~ Pet~1 + rl'-1;?-95 ver1f!e~
eJtl~ttP1 9 >lf";k~ 51~/ .(:/ 4-8R.
f'RODOCT , 5ERIE5•
ALBUQUERQUE KARSTEN
SQ.FT; DRAU!NCJ FILE lt.fORMATION•
MODE L NO. K3076A
MEE NEY
WATER 2,280 (CO) IRC
DATE DRAl1N· 5~EH
4-17-14 6 of 10
AAV
LAVY lln'
I In'
AAV
1 In'
LAVY lln'
I In'
I In'
3' VlR
OVAL TUB
I In' I In' 3' VlR
TOILET
DATE PRINTED: 4nln014 2:26 FH
PRINTED 8Y : Martinez, Rlch:lrd
2700 Ka1'lf1n ct. S.E. Alb, NM. 87102 (505) 242-5580 ph. SAVED BY: Mart lnezR
8 PDF created with pdfFactory trial version www.pdffactorv.com
OPT.
DAJJ
2'
State of Colorado
Division of Housing
May 6, 2014
PLANS APPROVED
Subject to field inspection
513142
SI»<. 1'
3'
1'
3'
NOTE$:
I. PIPE AND FITTINGS ARE SCJ.IEDULE 41i'> A85 DUN OR PYC.
2. ca-lNECTION Cf BUILDINc. DRAIN OUTLETS T06En.IER AND THE IR CCNNECTION TO BU ILD ING
SEWER TO BE DONE AT J06 SITE er onus.
3. OPTIONAL: HORIZONTAL DRAINAGE PIPING THAT Fil.NS BELOJ.I FLOOR JOISTS MAY BE Ct11TTED
AND ALL VERT ICAL DRA IN PIPES &TUBBED Cff AT OR ABOVE 60TTCt1 OF FLOOR JOIST&.
4. INVERT &LOPE OF ALL VENT FITTINc.5.
!:>. CLEANOJT& IN VERTICAL LINE& 51-lALL BE THROO:.H Y FITTINc.5.
6 . ALL DASHED LINE& AND FITTIN65 ARE 6ELOJ.I FLOOR AND ARE INSTALLED ON SITE.
1. 11> 4!:> DEGREE ELLS Wt 3.4 • Cf PIPE 6ETU.EEN MAY BE USED IN PLACE OF A '3li'> DEGREE ELL
UJ ITH A CLEANOUT.
8. A CLEANOUT IS TO BE PROVIDED AT THE BASE OF ALL WASTE OR SOIL &TACK&.
~-VERTICAL PIP ING SHALL BE SECURED AT INTERVAL& TO KEEP THE PIPE IN ALIGNMENT AND
CARRY THE u.EIGHT OF THE PIPE AT IT& MAXll1JM CAPACITY. &TACK& 51-lALL BE SUPPORTED AT
THEIR 6A5E.
Iii'>. ALL HORIZONTAL PIPING 51-lALL BE SUPPORTED AT INTERVALS Cf NOT MORE THAN FOUR < 4) FEET,
AT END& Cf BRANCJ.-IES. AND AT CHANGE& OF DIRECTION OR ELEVATICN TRAP ARMS IN EXCESS
OF THREE 131 FEET 51-IALL BE 5UPPORTED A& CLOSE AS P0551BLE TO THE TRAP.
II. HORIZC'NTAL DRAINAGE PIPING OF 3" OR LES& SHALL HAVE A MINIMl.N &LOPE Cf 114" FER FOOT.
ALL VENT AND BRANCH VENT PIPE& 51-lALL DRAIN BACK TO THE SOIL OR WASTE PIPE.
12 . OPT IONAL GARBAGE DISPOSALS 51-lALL BE TRAPPED 5EPARATEL Y FRCt1 ANY OTHER FIXTURE
AND MUST BE PROPERLY VENTED.
13. MIN 3' VENT THRCU:".H ROOF MRJ
14. IF l>JJTO VENTS ARE USED A CLEANOUT IS TO BE INSTALLED AT EACH AFFECTED VERTICAL DROP.
3'VTR
T/5 2'
3'VTR
3'
AAV
3' LAVY
I In'
3'
1 In'
PRODUCT :
ALBUQUERQUE
&E R:E&·
KARSTEN
MODEL NO. K3076A
MEENEY
WASTE &a.FL DRAU/1N6 FILE INFORMATION:
2,280 (CO) IRC
ORAi.iN BY· DATE ORA IJ..N: ~EE1'
4-17-14 7 of 10
State of Colorado
Division of Housing
May 6, 2014
PLANS APPROVED
Subject to field inspection
513142
4!;,000 BTU'& 3&,000 BTU'&
FURNACE W/1-1
TOTAL R UN =
~ '\=~-.,
2700 Kanltn el. S.E. Alb, NII . 87102 (505) 242 -S580 ph.
1 V4 63 1/4
!;4{1)00 BT U'&
RANGE
r
RE V IS IO N&
DATE PRINTED : 4nln014 2:26 A1
PRINTED 6'1": Mar\11\ez, Richa rd
SAYED 8'1": Mar\inezR
0 PDF created with pdfFactory trial version www.pdffactorv.com
11 MAX. B .T.U. --
leYI DATE I GENERAL NOTE& Dl<Au!N611TLE
MODULAR G A S PLAN APPROVAL
PACKAGE
34' INLET
SS{IJ00 BT U
G AS SYSTEM
TABLE 402 .4 (2 )
SCl-IEDULE 40 METALLIC P IPE
GAS• NATURAL
I NLET PRESSURE' L ESS Tl-IAN 2 PSI
PRESSURE DROP• O.S IN . H.E.
SPECIFIC GRAVI TY' O.~O
NOTE ,
F IFE LEGEND
1 "
Sl-I UT OFF VALVES AT ALL F IXTURES ABOV E F L OOR
3/4"---
1/2"---
f'RODIX:J,
ALBUQUERQUE
PLUMB ING SQ.FT,
2,280
DRAllN !lY: ---
!>ERIES.
0 1/2 " RISER
• 3/4 " RISER
KAR STEN
I t".oofl NO. K3076A
MEENEY
c:RAllJJNC. FILE l~F 0!<!1.Al lCN,
(CO ) IRC
DAT E DRAllN: 1 ~8'' of 4-17 -1 4 10
..
State of Colorado
Division of Housing
May 6 , 2014
PLANS APPROVED
ubject to field inspection
513142
BATT INSULATION
LENGTl-l OF 1-lOME
TURN UP AT
RIM JOIST
1\211 l-lC1245 POL ICl-lEM
ECONOBA ND STRAPING
RAN PARALLEL WITf-1 JOIST
AND SPACED AT 32 " O.C.
FULL LENGTl-l OF f-JOME
FASTEN EACf-1 STRAP
TO RIM JOIST AND TO
JO IST OUTSIDE EACl-l
Cf-JASSI BEAM WITf-1
l "x l "x16 GA . STAPLES
21 Wide
R-21=.04~2 LI -valu e
R=28=.0304 LI-val ue
S~EET: CS-BL
BLANKET INSULAT ION
LENGTl-l OF 1-lOME
BATT INSULATI ON
LENGT l-l OF 1-lOM E
FUL LY INSULATE
RIM
FAS TEN EACl-l STRAP
TO RIM JOIST AND TO
JOIST OUTS IDE EArn
Cl-lASSI BE AM HITl-l
l"x l"xl6 GA . STAP LE S
30 Wide
R-21=.04~~ LI-Value
R=28=.0308 LI -Val ue
Cf-IASSIS MAY BE
REMOVED ON -SITE
31 Wid e
R-21 =.0!;01 LI-Value
R=28=.03b~ LI-value
G PDF created with p ac ory na version www .p ac orv .com
BA TT INSULA TI ON
LENGTf-1 OF f-IOME
FULLY INSULATE
RIM
BLANKET INS UL AT ION / BATT INSULA TI ON
LENGTl-l OF f-J OME 1. LENGTl-l OF 1-lOME
TURN UP AT
RIM JOIST
1\2 11 l-lC1245 POL YC l-l EM
ECONOBAND STRAPING
RAN PARALLEL NITf-1 JOIST
AND SPACED AT 32" O.C.
FULL LENG Tl-l OF 1-lOME
FASTEN EACl-l STRAP
TO RIM JOIST AND TO
JOIST OUTS IDE EACl-l
Cl-lASSI BEAM WITl-l
l "xl"xl6 GA . STAPLES
R-6 CROSSOVER DUCT IN STA LLED ON SIT E
ATTACl-lED FROM FURNAC E TO EACl-l SIDE
OF RIGID DUCT PER FLOOR
40.!; Wide
R-21=.04~2 LI-va lue
R=28=.0364 LI-val ue
2700 Kersten ct . S.E. Alb, NM . 87102 (505) 242-5580 ph.
1,;-0·
L-------------------------------------
21'-0"
,------------------------------~-=~
: ~ I
~-------------~---------------------
r~5 pee:~> dt-x.re+ib'JA .f.o
&quire ener1Meer /!pp;zav,1-(
e)(lS/ll/1"/ ~t::Jfer5 r F pwe...
Ci!JYIA/ttf'fcl. <>Je. Bel?fZ..llA'J ~oil~
d.tSturbed I
CORNER REBAR
MATCH SIZE. NUMBER.
& LOCATION OF HOR
FOUNDATION SE CTION
112· • 1'-0"
-----------------------,
I
I
I
I
-----------------------~
a·.o· 12'·0"
""
-------------------~--~
I
1211
1 1)21
I
-----------------------~
1211
______ TOP_OF0:!~
WAL LREJNF, .-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--""""'--~~~~~~~~~~--.
TYPICAL CORNER REBAR
Floors over vented crawlspaces must be insulated; R-30 or enough to fill the cavity . Vents shall be
located below the bottom of the floor joist per IRC, R-408.1. As an alternative to i nsulating floors,
crawlspace walls shall be permitted to be insulated when the space is not vented to the outdoors and
meets the requirements of IRC, R-408.3. Take precautions to protect plumbing in these areas. 1". 1·-0·
3-0 VIEW
DESIG N DATA
1. ROOF LIVE LOAD• 20 PSF
2. ROOf SNON LOAO• 50PSF
3. BASIC WINO SPEED • 115 MPH
WINO IMPORTANCE FACTOR• t.O
'WINO EXPOSURE• C
INTERNAL PRESSURE COEF.• t0.18
4. EARTHQUAKE DESIGN DATA:
SEISM1C DESIGN CA TA GORY • 8
SITE ClASS • 0
GENERAL CON CRETE NOTES
1. WORK IN STRICT ACCORDANCE Wint THE LA TEST EDITION OF THE INT ERNA TIONAl
RESIDENTIAL COO E. ACI 332, ANO LOCAL ORDINANCES.
2. VERIFY Al l CONOITKJNS AN O DIMENSIONS PRIOR TO POURING CONCRETE.
3. USE GRADE eo REINFORCING STEEL.
4, use CONCRETE OF 3000 PSI MINIMUM COMPRESSIVE STRENGTH.
BEAR ALL EXTERJ OA FOOTINGS BELOW FROST DEPTH,
8. COORDINATE Wln-4 MECHANICAL ANO ELECTRICAL PRIOR TO POURING CONCRETE.
PROVlOE SLEEVES. BLOCKOUTS, ETC, AS REQUIRED,
1. CONTRA.CTOR IS RESPONSIBLE FOR PROPER PLACEMENT Of All ANC HOR SOL TS,
HCX.OO'NN ANCHORS. STRAPS, ETC. INSTALL PER MFR. REQUIREMENTS.
8. NOTIFY ENGINEER OF ADVERSE SOIL CONDITIONS ENCOUNTERED DURI NG EXCAVATION .
O, B EAR FOOTINGS ON UNOI STIJRBEO NATURAL MATERIAL, CA ON PROPERI. Y PLACED ANO
COMPACTED GRA NIAAR FILL
10, PROVIDE ALL NECESSARY CCllO WEA TliER PROTECTION FOR IN·PLACE CONC RETE
WHENEVER THE TEMPERATURE IS FORCAST TO FALL BEl.CIN 40"F WITli lN 14 DAYS OF
PLACEt'EN'T.
11. PROTECT CONCRETE AGAINST FREEZJNG UNTIL tT HAS CURED FOR NO LESS THAN FIVE
DAYS.
12. OONOTPLACECONCRETE INCONTACT'MTH FROZEN SURFACES.
GENERAL GRADING NOTES
1. SLOPE FINISH GRADE AWAY FORM THE FOUNOA TION AT A MINIMUM 2 PERCENT SLOPE
FOR A MINIMUM DISTANCE OF 10 FEET MEASURED FROM THE FOUNDATION.
2. FINISHED GRADE AT EXT. FOUNOATIONWAl l T08 EAMINIMUM81NCHES BELOW THE
TOP OF THE FOUNDATION WAll.
3. TOP OF FOONOATION WALL MUST B E A MINIMUM OF 12 INCHESABOVE THE DRAINAGE
CURB PLUS 2 PERCENT OF TliE DI STANCE FROM Tl<E ORAINAGE CURB TO Tl<E
FOUNDATION.
GENERAL FOUNDATION NOTES
1. PROV10E CRA'M.SPACE VENTS OR CONDITIONING
PER LOCAL COOES.
STRUCTURAL KEYED NOTES
MARK STRU CTURAL ITEM
1111 CONC, FTNG, • EXISTING 4
12tt STEMWALL ·a· WIDE ' CONT, w1 #4 VER TS ill z4• O,C, & (3) #4 HORS (I TOP, 1 BOT, & 1 MIOHT.)
ORILl & EPOXY YERTS 5" INTO EXISTING FOOTING.
1321 MUOSILL -TREATED 2X8 Wf 112" DIA. AN<;HORBot TS SPACED 72· O.C.AHD 12· EACH SIOE Of
SPUCES
2314 FRAMED WALL. htl's lb 1e· o .c . UN SHEATHED
2321 CQ.UMN • M'1.. Y 2.dl
..
~
"'
i " s: -uj
~
,;.; ~ t;
~ w x
0 c (/)
'•
16'·0'
~k .
~TI llC!§:lU IC§: ~ ICEiCi IC§: :'!
~ =' ='
-m c c
m ~ ~ ~ ~ :... :... :...
--
Q s e e e 66'-S" 1-iEAT DUCT 14xS. ALUMINUM e e w e
iD s: -~ ~
.1 -ill ·~ II 111111
:'! ~ ~ b
Q
~ ~ :'! ~ ~
-m ~ ~
j ~ l(l Sla te of Colorado
l ~
~ .. Divi sion of Housing ~ ~ -::-~~ ~ ~ Ma y 6, 2014 -~
~~ .~ b
Q s ::-. ~ l\l M ~ Ill m
-"1J "'
.! ii:. s: -::-2 -::-~ ''!.J q~ .,h ~g°2'.f "'' 66'-S' l-iEAT DUCT 14xS ALUMINUM
0 e e .•• 'ff! e e e e ::..
~ ~ PLANS APPROVED
~ ._------ill ;:: ~ ~ Subje<:l l o field inspection
~ ~ ~ :'! ~ ~ ~ :... ---513142
lcEi: :... icii: :... i:::ii::
16 )t) 10 16
~
~
NOTE : IRC '5 NOTES:
2xl0 lt2 SPF LUMBER fil 16 11 O.C. I. 403.2.1 -l-IEATING DUCTS ONLY-EX TERI O R : R-8
R-28 BLANKET INSULAT ION IN FLOOR 2. 403.b -FURNACE SIZE !?IZ> ,3~1 -1 1Z>,!?!?~
( RE VIS ION& leYI DATE I GENERAL NOTES DRA.WINCJ TITLE Fl<DD\JCf; &ERIE5' I l".OOEL NO. K3076A /(!?f#I 5;\ENGINW<i~'\!~~l~G~~~' ~"'~~\W ll<C. """''""' MOD ULAR ALBUQUERQUE KARSTEN MEE NEY
FLOOR FRAM ING SQ. FT, DRAW'NG FILE ~ATI CI<;
DATE PRINTED : 4n1n014 2:26 PM PLA N APPROVA L 2,280 (CO) IRC
He>-•I PRINTED BY: Martinez, Rlchlrct PAC KAGE I ~91' DRAll.N er , DATE DRAllN;
2700 Karste n ct. S.E. Alb, NM. 87102 (505) 242-5580 ph . SAVE D BY: MarllnezR ---4-17-14 of 1 0
· S PDF crea ted with pdfFactory t ria l ve rsion www.pdffactorv.com