Loading...
HomeMy WebLinkAboutApplication-PermitGarfield County Building & Sanitation Department 108 8`'' Street, Suite #401 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address r7,20 Nature of Work Building Permit Use of Buildin Owner NO. q�q c� 7 1 CD Ga-t,lgmQ G P/ 239/-1R[-Oo-036 I bit Or^a ��l �F.�-� ^ �cJ J Contractor Amount of Permit $ q Date -f— /SO. !R) , q C , 99 ‘, �-7 Clerk C2-1 /a/7-06 Permit No. GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8" Street. Suite 401. Glenwood Springs. CO 81601 at: 19970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 ) Parcel/Schedule No: p39 118 1000?SP Job Address. AGREEMENT PERMISSION IS HEREBY GRANTED 10 THE APPLICANT AS OWNER CONTRAt, IOR AND/OR THE AGENT OF THE CONTRA L I OR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORFIY GIVEN LN 30.28 201 CRS AS AMENDED THE SIGNER FURTHERAGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION. AND USE OF THE ABOVE DESCRIBED STRUCTURE THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPENCIES THE RESPONSI HILT' FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALL} WITH THE ARTICTECT DESIGNER BUILDER. AND OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST 1 HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) SI,(Q6 c{cl° /9 2.. g S J moi 0-4 ed . 100 Q l 01 a de Co go ?-7 1 Lot No. Block No' Subd. / Exemption. 12_ ►I N A fYlr,n. Wk -(731/44‘, 014.1 2 Owner -c m • Diw-tn Yweger Address iZol C.Q. loo Ph, `f49 -(12101- -1211: c14R 3 Contractor: bwri2v Address 5ct"'`te Ph• Lie. No 4 Archtect/Engineer: w'i ti Address. 4s S, amiu..4 - iitvorn rri Onx,ls Ph. 3b 3-1t,l.-lob K Lic No. 3S7 iq 5 Sq. Ft of Building: Sq. Ft. of Lot: it S RI -res Height No of Floors I 1. Use of Building RCS 7 ckvw, �i�l4Q ��wr4, i.! fi{4rv[Yv� waif O4etA-1' cON.) . 7 � O� Describe Work: tun kJ ek,.) L,nS'tVur.h6Y. h Class of Work bil, New ❑ Alteration o Remove J Addition J Move 9 10 Garage. 0 Single st J umbo 3 Cctx Double Carport: 0 Single J Double �. l Driveway Permit 0 .7 On -Site Sewage (X_- Lie Csev Pkr 14R."- Disposal bk.S1te Plan 11 Valuation of Work: SAdjusted 45-0, 600 , Valuations. 5 2/t) ��/ �J 12 Special Conditions: u)a A SEPARATE ISSUED TFISPERMIT AUTHORIZED CONSTRUCTION PERIOD I HEREBY APPLICATION PROVISIONS COMPLETED GRANTING TO VIOLATE LOCAL OF CONSTRUCTION v1 NOTICE ELECTRICAL PERMIT IS REQUIRED AND BY THE STATE OF COLORADO BECOMES NULL AND VOID IF WORK OR IS NOT COMMENCED WHHLN 180 DAYS OR WORE IS SUSPENDED OR ABANDONED OF 180 DAYS AT ANY TIME AFTER WORK 15 CERTIFY THAT I HAVE READ AND EXAMINED AND KNOW THE SAME TO BE TRUE AND OF LAWS GOVERN]NG THIS TYPE OF WORK WITHIN WHETHER SPECIFIED HEREIN OF A PERMIT DOES NOT PRESUME TO GIVE OR CANCEL THE PROVISIONS OF ANY OTHER LAW REGULATING CONSTRUCTION OR THE MUST BE CONSTRUCTION OR IF FOR A COMMENCED THIS CORRECT ALL WILL BE OR NOT THE AUFHORTTY STATE OR PERFORMANCE Plan Check Fee: /4 •7 Q • S� Permit Fee. 77Cj 7, 75 TO al Fee: J4,t, /so 3(0s�.l Dated Permit Issued: = 3776. ()CCG ou : .... Const. Type: Zoning: Setbacks: Manu. Home: ISDS No. & Fee: 15-01 �� )✓ . , SCIS/pb t L. tA— 3.0 , 1 it, DATrE� s P G DEFT. APPRO SE APPROVAL/DATE AGREEMENT PERMISSION IS HEREBY GRANTED 10 THE APPLICANT AS OWNER CONTRAt, IOR AND/OR THE AGENT OF THE CONTRA L I OR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORFIY GIVEN LN 30.28 201 CRS AS AMENDED THE SIGNER FURTHERAGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION. AND USE OF THE ABOVE DESCRIBED STRUCTURE THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPENCIES THE RESPONSI HILT' FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALL} WITH THE ARTICTECT DESIGNER BUILDER. AND OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST 1 HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) SI,(Q6 c{cl° /9 2.. g S J The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # 9 q Y7 ,,--f>t (nom Signature Date Bpapplicationfeb2006 FEE ESTIMATE FINISHED LIVING SPACE: S3R X 74.68 = ago/ &2/, W1 UNFINISHED BASEMENT: - X 41.00 = CRAWL SPACE: -- X 9.00 - GARAGE: / sm x moo = 1 R 4� UNCOVERED PATIO/DECK: / ? X 12.00 = IS- b (o COVERED PATIO/DECK: TI CM X 24.00 = % (4 YD MISC. MISC. TOTAL VALUATION: 31 L/ 651 . kV PLAN REVIEW FEE: 1,171 a 57 PERMIT FEE: ( /q7z_y TOTAL: -3‘.(340. .% MANUFACTURED HOME SET UP FEE: SEPTIC --- PERMIT: PERK: GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes ✓ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.5.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes ✓ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes ,/ 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes ✓ 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ✓ 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ✓ 8. Do the plans include design Toads as required by Garfield County for roof snow Toads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes ✓ 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes ✓ 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes ✓ 11. Does the building section drawing or other detail include the method of positive connection of al] columns and beams? Yes 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat of? (Building height measurement usually not to exceed 25 feet) Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes t/ No 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes / No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes i/ No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ✓ No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes i/ No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes L.7 No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes ✓ No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes ✓ No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimension a home can be on a lot is 20fl.wide and 20ft. long? Yes ✓ No 4 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes ✓ No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes ✓ No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes ✓ No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes ✓ No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -inspection fee? Yes 1✓ No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ✓ No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes ✓ No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes ✓ No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time off applicable inspection. Yes V No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcell Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes ✓ No 36. Do you know that the local fire dis ict may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. AAA, • /✓ 5IIS%0S Signature of Owner Date 944) - d126-1 9453- 9 34 45 Phone: nu -e, K.vtcjer- Ce.4 (days); »onn r -Cell (evenings) Project Name: Krat5er 2ebid.ence.. Project Address: -1 aryl f -*4 2d LOO C.arband&t,c CO Alto 2:3 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload: 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 75PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R -Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R -values are R-19. • Basement wall R -values are R-10 below grade, R-19 above grade. • Slab perimeter R -value and depth is R- 10/36in. • Crawl space wall R -values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. (F(10.' 6a/t)-(o6 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Permit 4 ! 8 2 Assessor's Parcel No. Owner's Namel� " ,^1 /�!/ r tArc+ (i)�res Pent t / Address w0�CvR t �'� Via le System Location / 1 �-^A �.'O7 'd4 rf ` o u 16a-3 Legal Description of Assessor's Parcel No. J,311- (81- 00-036 SYSTEM DESIG a 00 I Septic Tank Capacity (gallon) ./1/1/19 Other62 tect CPercolation Rate (minutes/inch) Number of Bedrooms (or other) 6 i` yO-r-447 L-.-f-se T A n /a- f ✓ ,/i)C Required Absorption Area - See Attached o? O3 0 NL S y 3 y,. - /03 4 Special Setback Requirements: , / 8 �7, Date 6 - / F- c 6 Inspector -2217421,e22,2 2 NC' /c 0-c-T,f1,-„-Z z i -T o..e n.0 FINAL SYSTEM INSPECTION AND APPROVAL (as Installed) Call for Inspection (24 hours notice) Before Covering Installation This does not constitute a building or use permit. phon'e'- 9d , System Installer 42'-- Septic Tank Capacity L, m r Septic Tank Manufacturer or Trade Name , i n Septic Tank Access within 8" of surface l i 4 1r Absorption Area Lr q LAM1 L^' fi Absorption Area Type and/or Manufacturer or Trade Name S111,.1 ✓ -Cl- Adequate compliance with County and State regulations/requirements (di`/ Other Date y�L4 / Ci Inspector /' (1» k 217 11 -64 - RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25. Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs.alters. or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense (5500.00 fine —6 months in jail or both). White - APPLICANT Yellow- DEPARTMENT PLAN REVIEW CHECKLIST Applicant ROC: it Date 6-3-0(to ilding At (Engineered Foundation Property Line S acks "C,1 Driveway Permit ba,_ 30ft Stream S [backs Planning/Zoning urveyed Site Plan eptic t and Setbacks rade opography 30% Zoni :Sign -off [tach sidential Plan Review List R•.d Impact Fees inimum Application Questionnaire OA/DRC Approval li.Mu/j bdivision Plat Notes Grade/Topography 40% Aire/Fire D artment Review Planning Issues a1u tion Determination/Fees Subdivision Plat Notes Flood Plai Buildin : Height :/Re ine Plans/Stamps/Sticker 7�Att ch Conditions Application Signed tan Reviewer To Sign Application Larcel/Schedule No. 0# Snowload Letter- Manf. Hms. Soils Report GENERAL NOTES: Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Property Search 1 Assessor Subset Query 1 Assessor Sales Search Clerk & Recorder Reception Search Basic Building Characteristics 1 Tax Information Parcel Detail 1 Value Detail 1 Sales Detail 1 Residential/Commercial Improvement Detail Land Detail 1 Photoeraphs Tax Area Account Number Parcel Number Mill Levy 011 R011013 239118100036 63.377 Owner Name and Mailing Address KROEGER, MARC ANTHONY & DIANN MICHELLE 1375 GREEN MEADOW ROAD CARBONDALE, CO 81623 Legal Description SECT,TWN,RNG:18-7-87 DESC: A TR IN LOT 12 & THE NWSE. BK:0514 PG:0205 BK:1769 PG:60 RECPT:691573 BK:0898 PG:0839 BK:0776 PG:0708 BK:0657 PG:0899 BK:0656 PG:0117 Location Physical Address: 7-87 SEC 18 TR IN LOT 12 Subdivision: Land Acres: 17.5 Land Sq Ft: 0 Section Township Range 18 7 87 Property Tax Valuation Information krt., !/..,.a.,, nnrnnont rnm/occs ccnr/narrPl acn9ParrrlNnm1m r-2 1Q 11 R 1 (l(N1lFi 11 /77/20066 Parcel Detail Page 2 of 3 Sale Date: Sale Price: 1/27/2006 360,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 0 0 No Building Records Found Tax Information Tax Year Actual Value Assessed Value Land: 300,000 23,880 Improvements: 0 0 Total: 300,000 23,880 Sale Date: Sale Price: 1/27/2006 360,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 0 0 No Building Records Found Tax Information Tax Year Transaction Type Amount 2005 Tax Payment: Whole ($1,513.44) 2005 Tax Amount $1,513.44 2004 Tax Payment: Whole ($1,614.02) 2004 Tax Amount $1,614.02 2003 Tax Payment: Whole ($1,356.94) 2003 Tax Amount S1,356.94 2002 Tax Payment: Whole ($1,399.28) 2002 Tax Amount $1,399.28 2001 Tax Payment: Whole ($1.407.06) 2001 Tax Amount $1,407.06 2000 Tax Payment: Whole ($1,408.26) 2000 Tax Amount S1,408.26 1999 Tax Payment Whole ($4,135.02) 1999 Tax Amount S4,135.02 Top of Page Assessor Database Search Options j Treasurer Database Search Options Clerk & Recorder Database Search Options �.._ ..... e,. o� nr..onnrrnIX,,,.,,r,Pr—)zoi lQinnnfiS 1 1/77/7006 Parcel Detail Page 3 of 3 Garfield Count) Home Page The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 - 2006 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. httn•//www earcoact com/assessor/narcel asoWarcelNumber=239118100036 11/22/2006 1— ' 0 Z a W 0 2 W o U ao� r � W 0 a C7 N Z Z 0, O N J0 mw m O N. U 0 mo a) w LT � 0o f0 WN �d 0 ote u H N Z t M co O co U c T r O 2 (112 5 Et W U O a V 0, Pi Z c 0 O co a J zv N O N ' a0 N T W a` CI 0on LL r m CC 00 a 3s a ill as pc 7 N D V o O o Ur Job located at 0 Job located N Permit No. Permit No. cted this structure and these m m m c 0 c O 0 d 1- O 0 co c O w m o. -.E. N � C 7 0� w g0 m0 c m A E I J r m Y c 'O 0 W O 3 m Ir 2 0 N pl o c L 03 Y m 0 m Y c c . c CO 0 CA Y {Q m w m t E — m 0. 0 O. 0 m .0 0 E c 0 0 `oci u c > > ° 0 CO u m ww m.0 L 0 c L d d d A >2 When correction(s) have been made, call for inspection at 970-384-5003. M d O 0 N 0. m O To it c Eo c 0 0 0. E'c O 8 a L p C 0 0 0 a o m u y m .c o E m E CO .0 C .0 d d L y C do `0 G' 0 U c Phone (970) 945-8212 W r 0 0 No. -Pl Y Assessor's Parcel No.0 h I ^ )'I -00 • Date n �/ BUILDING PERMIT CARD n Job Addre s d' CVL /CD C'cQ Co $/&a-3 y��6 c� � Owner LF ---- Address/23o7CR1 C' Pho # r�k.4ave? ' Contractor Addresss 2x 41= Phone # 9 > 9'3E74 Setbacks: Front Rear RH S/rd 225. W(d i' C 42 INSPECTIONS Soils Test Footing _ 6 /6 a e -see .�,G.,.(,l Foundation 7-r os�m Grout Underground Plumbing 7-//-06-7,am Rough Plumbing R -a9 -o# &» Framing '7406 *Ara Insulation 9 -/3-06 tora Roofing Drywall 9 -aa -c 4&n Gas Piping3o'71Z ciaq_,4 c7c -,nom ot. EXTERIOR Address No. Drains,' Decks -support & clearance to wood DeciO.etairs & rails agi✓gb Exterior lock. Fleshing Sound door 8 windows J/ Insect screens ✓ INTERIOR GARAGE Fire wall separation Service doors -1% min ✓ Door (20 min.) w/aulo closer -1W min Mech. equip. 18" above floor No opening into sleeping Seakt- BASEMENT-CRAWL AREA Access V / Insulation HeWroom/Stam Ventllstion LH Zoning Weatherproofing Mechanical Electrical Rough (State) 9 -R -C !3F Electrical Final (State) -' I2 Final //-/7-0C /Checklist 9ompletedl Certificate Occupancy # Date (( Septic System # (5?) - Date n6711 Final ! bA Other NOTES FINAL CHECKLIST MECHANICAL ROOM Boller Hot water K. FA gesroll Floor drain Clerance Air con system Hot water heater Combustion air Gee piping. valves LPG Drain FIREPLACE/STOVE Clearance to combustibles Termination of chimney Combustion air Hearth (12" or 20" on sides) GIw doors Certified by. REMARKS (continue on back) STAIRWAYS . Headroom (8'8") Railing 8 guardrails Width Rise 8 run KITCHEN Clearance above grill Exhaust fan Broiler exhaust (1 hr. chase) BEDROOMS Egress Smoke detector BATHROOMS Exhaust fan Shatterproof glow OTHER ✓l� I INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB L HOURS NOTICE IIIPLD FOR INSPECTIONS 20 NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO 0 Date IssuedPermit No.:[(^^ ,�I�..lII 0,1Gicc ... Zoned Area AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use , 1Cpwet c, +COc oS Add or Legal Description Owner Kitty r t' Llr (qc Vontrartor OW Oars Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing 6 /_ - Driveway Foundation ?-toc ! • pit/ Underground Plumbing 7 -i, -o6 - Insulation - _ 3_06 �,�. Rough Plumbing T_, -rob ��,s Drywall -, a -D isigliMill Chimney & Vent 9- 6, 4, ,,,1 ectnc ina (by State 4.Yrrigrffga Gas Piping ?_L -0C , Final /_/7-06 ,. Electric Ro h 5 or) g3 a ®G Septic Final 7- 3 -.- . Framing y -g-06, pre. (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTER1OR, UNDERGROUND OR ABOVE GROUND. IT IS NOT TRANSFERABLE For Inspections C41=3 108 8th Street Glenwood Springs, Colorado APPROVED DESTROY THIS CARD Da �a/r�/t��vl{SaR.n BY IF PLACED OUTSIDE - C VcreNVITH CLEAR PLASTIC