Loading...
HomeMy WebLinkAboutApplication-PermitPermit No: GARFIELD COUNTY BUILDING PERMIT APPLICATI0N 108 8'" Street, Suite 201, Glenwood Springs, CO 81801 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-8003 Parcel/Schedule No: i 3/ ( ] 3 Job Address: _ 1 00 6- Piell 1 Lot No: Block No: Subd. / Exemption:j 0 lUL& Cd:2,-e-k_ tr--ati. Wk Ph: L1t1 612 ti L Owner: Ali- .-t--C Address R t G L.1 1l- a 3"u .1.-r4S` tji _c4 LI Ph: '144 32`11 3 Contractor: -V Lc-lG -( v .1,'C . Address: Ph: ��I1�� Lie. No 4 Architect/Engineer: ikiktc Q 7155 NAI C_ Address:. 4-4o I' 1`t (1 S 'C et}V-.ge,r�-tyl Ph:. ct 3 t'r3 Lie. No. 5 Sq. Ft. of Building: Sq. Ft. of Lot: Height: a2 ii No. of Floors: 6 Use of Building: E.--spts b EA + t 1 cc FitHi L- ONO. C .cl,uc -<.>, 7 Describe Work: Iu (e V' , tAt- cii__ AI� (A.,�,Tl�-C l tv A. -.1U.3 3 Class of Work: q New O Alteration 0 Remove Addition ❑ Move• 9 10 Garage: ❑ Single U ' Double Carport: ID Single ❑ Double Driveway Permit ❑ On -Site Sewage I/A Disposal I Site Plan 11 Valuation of Work: $ %fo roi �, p it , �v P Adjusted Valuations: S Z -11 /73437- 12 Special Conditions: , e ` �`'e j wait,:s .t o-tLo_4 A 1 -,.1,, -es c,,,` norKin, C. a . NOTICE A SEPARATE ELECTRICAL PERMIT 1S REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK 1S COMMENCED. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLLIhD WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGU TING CON UCTION OR THE ERFORMANCE OF • r CTIO �t> A L 0 Plan Check Fee: /27Z,(J ^� Permit Fee: /QI ! 53 Total Fee: r �� DatedPermitIssued: OCC Group: Const. Type: Zone Setbacks: Manu. Home: ISDS No. & Fee: AUC& `.1 p 2,j. ER A BL G DEPT PLNG, DEFT. ,70,67 APPROV-./DATE APPROVAL/DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER. CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION. ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE !INITIAL): dh� Iln? �' ((�la� �b/ob The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until alI the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, anchor State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET, I understand and agree to abide by the above conditions for occupanujp and the issuance of a Certificate of Occupancy for the dwelling under building permit # Wt) 7-4 Signature BpcontOct2004 Date VALUATION/FEE DETERMINATION Applica t �P-44� Subdivision 75(..(11, et . Addresl b ( CCITC-4-4y Lot/Block `3 7 �.. �t Date Contractor ' SetukcrLuf C-v�,S 9a-6 Finished (Livable Area): Main W jy, Upper /OW Lower Other Total Square Feet 31 {o c1 y, Valuation Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Valuation 5'/( f Crawl Space: Valuation 2089 / / g 0 1 Decks/Patios: Covered (08 Valuation l38 2 x Z51 — 57°4 Open Valuation Total Valuation 271 /9 3:92 Applicant Building PLAN REVIEW CHECKLIST 8h4 Date '$-'/ Engineered Foundation Driveway Permit Site Plan (C,./(ASeptic Permit and Setbacks Grade/Topography 30% Attach Mtsi -o "• Minimum Application Questionnaire Subdivision Plat Notes k/4 Fire Department Review L.. 4 nation Determination/Fees Red Line Plans/Stamps/Sticker Attach Conditions Apple ation Signed Plan viewer To Sign Application arcel/Schedule No. a.4, 40# Snowload Letter- Manf. Hms. a-6" Soils Report GENERAL NOTES: Planning/Zoning -- Iiaeeppz4�.Line Setbacks ,64-1 lea. o6 Qft Stream Setbacks ood Plain uilding Height 'ning Sign -off e' Load Impact Fees #4----©A/DRC Approval (" adeiTopography 40% ✓Planning Issues Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes (, 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes iU J 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes Al 4.5 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes Lf 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes L/ 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes Ly` 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave ofa gable or shed roof or the top ofa flat roof? (Building height measurement usually not to exceed 25 feet) Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes Pr No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes No V 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes V No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes. No V 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes V No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes V No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes V No 21. Will this be the only residential structure on the parcel? Yes V No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimension a home can be on a lot is 2011.wide and 20ft. long? Yes V No 4 ■ Basement wall R -values are R-10 below grade, R-19 above grade. ■ Slab perimeter R -value and depth is R- 10/36in. ■ Crawl space wall R -values are R-10 below grade and R -I 9 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas, Division of Registrations Page 1 of 1 Colorado The Official State Web Portal Division of Registrations Electrical and Plumbing Permits Online View Inspection for Permit 636785 Indicates Required Field Inspection Permit #: 636785 Inspected Date: 04/1612008 Permit Holder: WEST WIRE, INC Site Address: Lot 41, Choke Cherry Court City: Carbondale State: CO Zip: 81623 Inspection Type: Final Status/Action: Accepted Reinspection Fee Paid $: Comments: Corrections: Inspector's Name: Robert Fuller Phone: 970 625-4561 Print for Display J OK A • Questions? Check out the Definitions Page or Frequently Asked Questions (FAQ). • Please take our Survey to tell us about your experience with the online permits site. Generated: 04/22/2008 06:53 a.m. Privy Statement 1 Disclaimer Technical Rssistance: E-mail Information Technology Section Federal Home Page 11 State Home Page 11 Department Home Page Top of Page E -Mail the Division of Registrations 1560 Broadway, Suite 1500 Denver, CO 80202 (303) 894-2985 - Phone (303) 894-2310 - Fax Rglay Colorado (TTY (English & Spanish),Voice, VCO, ASCII, STS Assistance Numbers) elk [nn4ume�POattlmn https://www.dora.state.co.us/pls/real/EP_WEB_Inspection_GUI. ShowPage?p_user_type... 4/22/2008 Dec. 5. 2006 10:40AM MAGGERT / LEONARD No•1151 P. 1/1 Ma etttructural Engineers 580 Main Street, Suite 300 (970) 963-9643. Fax (970) 963-0135 www.Ma ggertEngi neera.c oni Carbondale, Colorado • 81623-2065 December 4, 2006 Mr. Matt Provost Garfield County Building Department 108 8th Street, Suite 401 Glenwood Springs, Colorado 81211 Re: Proposed Residence, Permit #9946 Lot 37 - Blue Creek Ranch Subdivision 41 Chokecherry Court Carbondale, Colorado Dear Matt: RECEIVED DEC 0 5 2006 tiARF IELD COUNTY BUILDING & PLANNING On Friday, December 1, 2006 at the request of Peter Selucky of Selucky Construction, I conducted a visual observation of a roof joist bearing condition as listed on your in- spection correction notice sheet for the above mentioned residence, dated November 16, 2006. The location of the condition observed, was in the area of the upper bonus room of the structure. Bearing of the 2 x 12 @ 16" on center roof joists was atop a 51/8" x 18" glu- laminated beam and were cut horizontal at the heel and resting perpendicular to the beam. Additional 2 x 8 members approximately 4'-0" in length were placed and attached to the sides and flush with the bottom of the roof joists in place with a birds mouth cut at the end. "Simpson" hurricane ties at the bearing end of these joists were also added. Addition of the 2 x 8 members and framing ties adequately satisfies conditions of lateral stability and movement. If you have any questions regarding this report, or if we can be of further service, please contact us. Sincerely, wa ;MAW tr4'6W) Reviewed By: 10.100 .REGA, ,. ,,,,,„,,;;....,„,-. ... . Irk t41 . .. ,2371 e .44,...,2cON'i C:f;,,C111.d. j Alvin J. Rakowski Barry Maggert, alvin@maggertengineers.com barry@maggertengineers.com cc: Peter Selucky - Selucky Construction No. ,, p?CI() r Assess is r Parcel No 3 / - 3/ (I -4o - 0-3 eai%efvDate 62/5/e 6 P BUILDING PERMIT CARD • --- Job Address CC( [ ' - C .&‘Q ( (a-3 o- 3.7 6 -Lk c` = - Owner K C% 6 it LL -c- Phone # j 3 a`9 7 Contractor Co0 Address a ' Phone #9011 - Setbacks: Front Rear 51 (.....26\A„, Soils Test ksta. Footing Le— 7-19C¢ Foundation 6 -a 9-'6' ' - Grout Underground Plumbing /V/# Rough Plumbing JJ"5-06, I3. t e043 7 Framing /2--5=-06' Insulation IoZ� T-�69 Roofing Drywall AR -f4Y-eseivir452, Gas Piping Ga.-0691,72- RH LH Zoning INSPECTIONS ,U67 : P -c-') (.44,-tasz_e_.&4.1, to.> Weatherproofing Mechanical Electrical Rough (State) k� Electrical Final (State) pr nal +x3-08 /Checklist Completed? ' Certificate Occupancy # Date 't- -5\- -O �O15 P Y Septic System # SQP,� Date ` Final Other /V7i" (A1 -0,34,`q_` NOTES /aki/PfAffi RAN% kwit -q--�'6' (continue on back) COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at d2V/ C� Permit No. 9 0 yp I have this day inspected this structure and these premises and found the following corrections needed: A) 2 2P('-e4,v) eede‘e- 3Wt'u aAe 0(40-34 4I) eZee‘ -ZrX9/4-.( 41.;1 cs) iziv741 deterly 4441 4,,,4-7/ n Call for Re -Ins • ection ❑ $50.00 Re -Inspection Fee must be paid prior to Re -Inspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date //-06" 20 Building Inspector -P7iege,,a-e,zPhone (970) 945-8212 COUNTY OF GARFIELD - BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at Cady/ 66,4, 64.1.-z_y___ Permit No. 19y0 I have this day inspected this structure and these premises and found the following corrections needed: iJ get 6y0-e,46.e.4.eLeee.,� .o2i9/ You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for inspection at 970-384-5003. Date /-571n6 20 Building Inspector P7,' Phone (970) 945-8212 COUNTY OF GARFIELD - BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at G �f Permit No. FFVO I have this day inspected this structure and these premises and found the following corrections needed: 11ChalA a, 4.e_.-;e:.)-Afee-e-Z-€;-,-,/ oe,e, lee,eyede...e:g a,,•-d-I-e-e‘teleolealet-e-e--/0114-6;17 jc5-Z4d4'1 .fic At:44'j ,ee/e_-a. 20.--A-ree* 01 - ,04:0")/le- 6.' --y°``e'e2- .r-rt You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for inspection at 970-384-5003. Date I/%3 20 Building Inspector Phone (970) 945-8212 COUNTY OF GARFIELD - BUILDING PERMIT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 00`W G Permit No. ?9Y6 1 have this day inspected this structure and these premises and found the following corrections needed: Cis ,ng 3/4//4'?q 4441.e.yegige,-4,1,eze:;7..,;71d-r-etoti`e 7Wely 42To-s-r: You are hereby notified that the above correction must be inspected before covering. When corrections have been made, call for inspection at 970-384-5003. Date //--/6--06 20 Building Inspector Phone (970) 945-8212 Num....,....._ INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDINGPERMIT GARFIELD COUNTY, COLORADO Date Issue42.14C41 Zoned Area Permit No 9'9'40 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location-, construction and erection of the proposed structure for which this permit is granted, and further agrees that if the -above. said regulations are not fully complied with in the zoning, location, erection and :construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector andmeIMMEDIATELY BECOME NULL AND VOID. Use op, r _oVIP411i 4 - Address r Le Descriptioj� -F Oss iOF Owner Contractor �r UL IN C_ OS (- Rear Setbacks Front Side Side This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECT ON RECORD Footing 6.7 "06 ' Driveway Foundation 6-.29-06. "A / Underground Plumbing . Insulation is _- Rough Plumbing -5-06 *- - Drywall _ y oy . Chimney & Vent , , 5 Nva. --Electric Final (by State Insp ,; - _ - " i•IMO Piping v Final el.23-0ir - , `''% Electric Rou l h (B State Inspector) ''':_c, Septic Final r/,. Notes: /)/# Framing /2 - , � �,y� ..,-.7,----5......," � (To include Roof in place an t -----' -- and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED WHETHER INTERIOR OR EXTERIOR, AND APPROVED BEFORE COVERING - UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD Dat By494044- IF PLACED OUTSIDE - COVE WITH CLEAR PLASTIC Parcel Detail Page 1 of 4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Propea Search j Assessor Subset Query 1 Assessor Sales Search Clerk & Recorder Reception Search Basic Building Characteristics f Tax Information Parcel Detail 1 Value Detail 1 Sales Detail 1 Residential/Commercial Improvemen t Detail Land Detail 1 Photographs Tax Area 011 Account Number R009763 Parcel Number 239131420037 2007 Mill Levy 60.843 Owner Name and Mailing Address KOBA, LLC 1100 B RIVERSIDE ROAD ABBOTSFORD, BC VZS7P1 Assessor's Parcel Description (Not to be used as a legal description) SECT,TWN,RNG:31-7-87 SUB:BLUE CREEK ,RANCH LOT:37 ADDRESS PER PROJECT MANAGER PRE:R007827 BK:506 PG:570 BK:506 PG:569 BK:506 PG:567 BK:486 PG:723 BK:486 PG:721 BK:476 PG:147 BK:449 PG:141 BK:449 PG:139 BK:334 PG:378 BK:0506 PG:571 BK:1570 PG:918 RECPT:648763 BK:1450 PG:139 RECPT:623540 BK:1387 PG:101 RECPT:610821 BK:1209 PG:697 RECPT:570001 BK:1209 PG:694 RECPT:570000 BK:0932 PG:0775 BK:0840 PG:0215 BK:0828 PG:0837 Location http://www.garcoact.com/assessor/parcel, asp?ParcelNumber=23 9131420037 4/30/2008 Parcel Detail Page 2 of 4 Physical Address: 41 CHOKE CHERRY CT CARBONDALE Subdivision: BLUE CREEK RANCH Land Acres: 0.222 Land Sq Ft: 0 Section Township Range 31 7 87 2007 Property Tax Valuation Information Sale Date: Sale Price: 3/22/2004 160,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 1 0 Actual Value Assessed Value Land: 175,000 50,750 Improvements: 0 0 Total: 175,000 50,750 Sale Date: Sale Price: 3/22/2004 160,000 Basic Building Characteristics Number of Residential Buildings: Number of Comm/Ind Buildings: 1 0 http://www. garcoact.com/assessor/parcel.asp?ParcelNumber=23913142003 7 4/30/2008 Residential Building Occurrence 1 Characteristics TOTAL HEATED AREA: 3,989 ABSTRACT CODE: SINGLE FAM.RES- IMPROVEMTS ARCHITECTURAL STYLE: 2 -STORY EXTERIOR WALL: BOARD/BATT EXTERIOR WALL: CORG METAL ROOF COVER: COMP SHNGL ROOF STRUCTURE: i RIDGE FRME INTERIOR WALL: DRYWALL FLOOR: HARD TILE FLOOR: CARPET FLOOR: HARDWOOD HEATING FUEL: GAS f 11 http://www. garcoact.com/assessor/parcel.asp?ParcelNumber=23913142003 7 4/30/2008 Parcel Detail Page 3 of 4 HEATING TYPE: IIFORCED AIR STORIES: BATHS: ROOMS: UNITS: BEDROOMS: YEAR BUILT: STORIES 2.0 4.5 8 4 2007 Tax Information Tax Year Transaction Type Amount 2007 Tax Payment: First Half ($1,543.90) 2007 Tax Amount r $3,087.80 2006 Fee Payment ($33.15) 2006 Interest Payment ($149.04) 2006 Interest Charge $149.04 2006 Tax Payment: Whole ($2,129.08) 2006 Fee Charge $33.15 2006 Tax Amount $2,129.08 2005 Tax Payment: Whole ($1,950.74) 2005 Tax Amount $1,950.74 2004 Interest Payment ($47.85) 2004 Interest Charge $47.85 2004 Tax Payment: Whole ($797.56) 2004 Tax Amount $797.56 2003 Tax Payment: Whole ($16.48) 2003 Tax Amount $16.48 Top of Page Assessor Database Search Options j Treasurer Database Search Options Clerk & Recorder Database Search Options Garfield County Horne Page The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. http:I/www.garcoact.comlassessorlparcel.asp?ParcelNumber=239131420037 4/30/2008 Garfield County Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address 64 `-I I Ce - Nature of Work Building Permit .c -Q Use of Building V ?a4m4-17. Owner l(C)/Sil- L LC_. Contractor Amount of Permit $ 3 oma-' ! NO. cI9 (4 -- C ` C ?IC.e3 3 - - o37