Loading...
HomeMy WebLinkAboutApplication-Permit• Garfield County Building & Sanitation Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address (Ma -lei Ok (t t Cts NO. 9 Oma% Nature of Work Building Permit a9(de) - a- (3n - oao Use of Building -f3 CVS Owner rinQtA(.R Contractor l Jl iThn 2-C Amount of Permit $ (p($, Date - aC ' CY•ea Permit No: Job Address: GARFIELD COUNTY BUILDING PERMIT APPLICATION 10SW" ! Street. Suite 201, Glenwood Springs, CO 81801 Phone: 870-845-8212 / Per 970-384-3470 / Inspection Line: 970-384-5003 9% fro Parcel/Schedule No:aL4(03— I I oZ — V b —o ao 1 Lot No: • Block No: Subd. / Exemption: 2 er: K1ci, AaNtiti Oreo Address L I 1 e 0410 CZ, Il, Ph: 963-7`DG3 Wk Ph: art -4013 3 tractor: tcJ woosa LA) OT'£1e- Address: LocMt. Ph: `r- Lie. No. 4 chllect/Engines JO n . iM)� f.2T Address_ �Iv I" Ph: Lie. No. 5 Sq. Ft. of Build g: 113¢ Sq. Ft. of Lot: .081-X--1/ Height: / �� No. of Floors: /r 6 Use si Building: 7 Desgbe Work: 1 -�." 1�1Jc t.A tP {� -hp OQ li ' �htls le t r -l -t MJ11Jy� jJS a L EY -rt 2tv- 8 Class of Work: g New iJ ❑ Alt9ration o Remove U Addition U Move 9 10 Garage: ❑ Single ❑ Double Carport: ❑ Single U Double o Driveway Permit ❑ On -Site Sewage Disposal U Site Plan 11 Valuation of Work: $ GD` � ,,. C) _ �(,J Adjusted Valuations: S G 7 7 7- L 12 Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOD IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS. OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING C STRUCIION OR THE PERFO • CE OFC' N. Plan heck Fee: 27 , 0 I Permit Fee: 421. 55 - Total Fee: rP (93; 5( Dated Permit Issued: OCC Grp n • _.i�(��/ f�" Const. Type: Zoning: Setbacks: Manu. Home: ISDS No. & Fee: aOso r OF R /EFT•2Rcco om=3-2g-011e APPROVAL DATE ..OVAL/DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION. AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION THE REVIEW OF SUBMITTED PIANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABU IES BY GARFIELD COUNTY FOR ERRORS. OMISSIONS OR DISCREPENCIES THE RESPONSE BATTY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARFICTECT. DESIGNER. BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. Garton] .003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE IINmAL). -Qv C« 71 13409 S • The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily �L visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; ) OT GAZfrck� 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; N P- 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or ©ic_ decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; O r 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, anchor State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancyase and the issuance of a Certificate of Occupancy for the dwelling under building permit # "IW -0 p Signature BpcontOct2004 al 3 0 Date C)1 Applicant PLAN REVIEW CHECKLIST Date 3 -Z p . a, LL Building /E [ngineered Foundation , / v Driveway Permits /CL.{IC (ca (./Surveyed Site thpeptic Permit and Setbacks `'Grade/Topography 30% ✓Attach Residential Plan Review List L ----Minimum Application Questionnaire an Subdivision Plat Notes /`t/ee-Fire Department Review .✓ luluation Determination/Fees -Red Line Plans/Stamps/Sticker each Conditions Application Signed —4iaq Reviewer To Sign Application arcel/Schedule No. /11440# Snowload Letter- Manf. Hms. ,i 1 Soils Report GENERAL NOTES: /543-4 18 - 77, 77,1 Planning/ZoningPl ✓Property Line Setbacks /t(,430ft Stream Setbacks n At Flood Plain a k. Building Height ✓lining Sign -off Wit Road Impact Fees %//l HOA/DRC Approval -76Mde/Topography 40% //./Planning Issues a /Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind) speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of apr ligand not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the elope. Yes 2. Does the site plan also include any other buildings nn thethe n rt , setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do jpply. Yes ✓ 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent p operties), streams or water courses? Yes 13 /k 2 Does the site plan indicate the location and direction of the County or private road accessing the prope Yes 5. Do the plans include a foundation_plan indicating the size, location and gNeing of all reinforcing steel p accordance with the IRC or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and thyclearances required between wood and earth? Yes ✓ 7. Do the plans indicate the size and location of ventilation openings tor the attic, roof joist spaces andr flits? 7 Yes N 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 po aper sO1aTP foot up to & including 7,000 feet above sea level), floor loads and }rind loads? Yes 9. Does the plan include a building section drawing indicating foundatiolt, wall, floor, and roo construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roofrafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all column are Yes t/ — 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and gave of a gable or shed roof or the top of a flat r9of? (Building height measurement usually not to exceed 25 feet) Yes ✓ 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and odel and Colorado Phase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply wi the IRC? Yes L Q- No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleepi rooms and/or basements comply with the rermin-tYIPntc of the IRC? Yes No 16. Does the plan include a window schedule or other verification that windows provide natural light and v tilation for all habitable rooms? Yes No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes �i1pr No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be acceptewithout it. Yes t) Jk- No 21. Will this be the ou#Y residential_sucture on the parcel? Yes ✓ No Ja`� If no -Explain: 6l-rR-� t 22. Have two (22omplete sets of construction drawit3g,5 been submitted with the application? Yes 23. Do you understand that the minimum dimension a home can be on a lot is 208.wide and 2011. long? / Yes ✓ No 4 24. Have you designed or had this plan designed while considering building and other constructio code requirements? Yes V No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zo istrict? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27. Do you underst d that approval for design and/or construction changes are required prior to the applica ' of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your buildingpe rt? Yes No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to -5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $500 re -inspection fee? Yes t/ No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy o e building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC✓ Yes No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No , u.) sig 5 C 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parce1111111111111111t Number for the lot you are applying for this permit on prior to submittal of a building pe application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire district may require you t ubmit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? / Yes I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. 43-/0 C Signature ofOwner /, Dattel Phone: , f 1 - 4 0I (days); -1lQ1 _73g3 (evenings) Project Name: C' n Project Address: 02`/0 Ci• R . (`1 Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application 6 Assessor's Parcel N [ 13..ZL G9c Date CP BUILDING(��RMIT CARD Job Address n1I© n_P X01 C r� Owner'F L1 S±I.L.Jf gr_h n 7t Address - Phone #Ckrn3 7C)-13 Contractor )!blie Address Phone #379- 1-a Front Rear RH LH Zoning �� INSPECTIONS Soils Test"Weatherproofing Footing r_:-040 et, Mechanical Foundation 5- 1. V Electrical Rough (State) A --- Grout Grout Electrical Final tate) Underground Plumbing Final 'cr2&Gly hecklist Completed? t --- Rough Rough Plumbing 69-24000 711- Certificate Occupancy # Framing Date Insulation Septic System # Roofing Date Drywall Final Gas Piping Other NOTES Setbacks: (continue on back) INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS r BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued3:'0.(.Zoned Area Permit No.925LXi AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use Address or Legal Description Ownergainke Contractor Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. 3 INSPECTION RECORD Footing 4.„.2,-7-0(p. 4 .s_ . Driveway Foundation s'_/S =o&y Underground Plumbing Insulation Rough Plumbing Drywall Chimney & Vent Electric Final (by State Inspector) Gas Piping Final (_ Zio -600— Electric Rough (By State Inspector Septic Final Framing (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call 384-5003 108 8th Street Glenwood Springs, Colorado APPROVEDDO NOT DESTROY THIS CARD Date BylakaWlild IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC