Loading...
HomeMy WebLinkAboutApplication-PermitGarfield County Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address Nature of Work Buildin NO. qq9 tt_s_0,W_O& .LK ci-LtL- Permit Use of Building0.12)t.)e-n Owner tioin bre 41,/_.Contractor Amount of Permit $ Ig- u3 Date - D (4D Clerk (80J6 Pe Job Address: GARFIELD COUNTY BUILDING PERMIT APP LI CATION 108 8"" Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970.945-6212 / Pas: 970.8843470 / Inspection Line: 970-384-5003 Permit No: 1 b9 Parcel/Schedule No: y. 3 q 5 g t13 1 Lot No: i i Block Na: Subd. /Exemption: .�� wsbr `dire.. Citl,,0 k 2 owner:.. -~ c]eilet t i ll V.Wve1"e' ddress 7,066 Gieuwmmj Ph 4 2.► 05 kza 5300. :3 ContractAddress: { _ Ph: Lic. No. Architect/Engineer: Address: Ph: Lie. No. 5 Sq. Ft. of Building: Sq. Ft. of Lot:4 I Height: No. of Flaors: 6 Use of Building silo coo f 7 Describe Work: {� �},�p i�ai 0"-4+* •6'n`5i r Lei R New go ID Alteration o Remove Addition 0 Move 8 Class of Work: i 9 10 Garage: 0 Single ❑ Double Carport: ❑ Single 0 Double o Driveway Permit 0 On -Site Sewage Disposal - l Site Plan 11 Valuation of Work: $ Adjusted Valuations: S g z.1— /03af 45-1 12 Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MOST BE ISSUED BY THE STATE OF COLORADO. Plan Check Fee: J 7! Permit Fee: % ] ) 5- (I I•� THIS PERMIT BECOMES NULL AND VOID IF WORE OR CONSTRUCTIONC� AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR. IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF I80 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TETE SAME TO BE TRUE AND CORRECT. ALL OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CON - i ON. Allik N..MIL ii,i °I U b Total Fee: ig 3, 50 Dated Permit Issued: ©C Giou�l : .� t' yam(, Const. Type: Zoning: pv0 Setbacks: Manu. Home: 0� ISDS No. & Fee: tj ( A .�% � �V[► i 1 BV re. ' d "PL DEPT, APP ' OVAL/ 1' - TE . • • OVAL/DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING TIIE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR L1ABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER. BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS LNTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): el The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; S. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, anchor State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy. s and :e issuance of a Certificate of Occupancy for the dwelling under building permit # Si ure pco Oct2004 Date d$, 0'66 FFA QST/MATE FINISHED LIVING SPACE: UNFINISHED BASEMENT: CRAWL SPACE: X 9.00 aArkLy X74.68= X 41.00 GARAGE:. X 18.00 =- UNCOVERED PATIO/DECk: X 12.00 = COVERED PATIO/DECK: / g X 24.00 = 47 3,3. MISC. MISC. TOTAL VALUATION: PLAN REVIEW FEE: '� a. 3 PERMIT FEE: Ins as TOTAL: 1-03, 5 C,) MANUFACTURED HOME SET UP FEE: SEPTIC - PERMIT: PERK: 2-1403a.d0 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to deteLuline compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. l . Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as itis shown on the final plat with the proposed structure located within the envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special sacksdoapply. 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes 2 4. Does the site plan indicate the location and direction of the County or private road accessing the property? es 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method ofpositive connection of all columns and beams? Yes 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase I1 certifications or phase 11 EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or ants? No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not .. cepted without it. No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. e two (2) complete sets of construction drawings been submitted with the application? 23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes No 4 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pickup your building permit? Yes No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -inspection fee? Yes No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the ParceliMINNIPt Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes hereby acknowledge that I have read, understand and answered these questions to the best of my ability. tune of Owner 3 t Cl 7.5 (days); Project Name: cfle 03 06 06 Date (Ik5 Ott45 (evenings) Project Address: OW W 6 L) ti c\ ? o s c tom. vkoe Elite & cc( Fr'itt5 G $l6n2 V Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a perrnit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC,.IMC, IPC,. Setbacks: Check subdivisions and zone district for setback requirements. Snowload: 40PSF up to 7000ft. elevation. 50PSF• 7001 to 8000ft. 75PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B nr C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R -Values: Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. w Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R -values are R-19. • Basement wall R -values are R-10 below grade, R-19 above grade, Slab perimeter R -value and depth is R- 10/36in. Crawl space wall R -values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Con mon walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas, No c -'l99 Assessor's Parcel No Date - " UILDING P RM1T CARD Q t .fob Addre s 0 \ t 1 � C. � - Owner �re- Co Y1lY5 i 1 Address �a pPhone #0 Contractor t) L Th -2- Address_ Phone #C — Setbacks: Front Rear rnjOC*6-1-9-1 CtP--L-PN,, Soils Test Footing Foundation Grout Underground Plumbing Rough Plumbing Framing Insulation Roofing Drywall Gas Piping RH LH Zoning INSPECTIONS Weatherproofing Mechanical Electrical Rough (State) Electrical Final (State) Finat3"Z0-077Checklist Completed9 Certificate Occupancy # Date Septic System # Date Final NOTES Other (continue on back) Garfield County i r � Date: March 12, 2009 To: Jesse & Jill Steindler PO Box 1465 Carbondale, CO 81623 Dear Permit Molder, Please refer to your building permit number BUILDING & PLANNING DEPARTMENT 9909 , issued 5/9/2006 A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since issued Please be advised that building permits expire, per Uniform Building Code, section 106.4.4 and International Code Section 105.5 " Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, provided no change have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. in order to renew action or a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work. If you have not responded within thirty (30) days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Clerk and Recorders office that indicates that the work permitted per Colorado Revised Statues 30-28-205 & 210, was not inspected, is not approved and the building or area is illegal to occupy and is subject to legal abatement action. Thank you for your cooperation. Sincerely, Jim Wilson Building Inspector 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 Jesse and Jill Steindler P.O.Box 1465 Carbondale, Colorado, 81623 March 13, 2009 Reference: permit # 9909, issued 05/06/2006 at 0106 Wild Rose Drive Dear Mr. Wilson, RECEIVED MAR 1 7 2009 GARFIELD COUNTY BUILDING & PLANNING This letter comes as surprise; 1 was under the impression that the porch roof for which the permit was acquired had been inspected. We built the porch during the summer of 2006 and called the Building. and Planning office upon completion. If need be please feel free to inspect it again as it is still standing. 1 will await your response in this matter, please feel free to call me or my wife Jill at home at 945 2105. We are not home during most days, but will return your call promptly the following day should we miss it. Respectfully, sse Steindler GOLF CLUB eiNI) MOUNTAIN cOMMUNft'Y 1 March 2, 2006, Builder Name: Jesse and Jill Steindler 0106 Wild Rose Drive Glenwood Springs, CO 81601, Re: Application No.: 5, Address of Submittal: 0106 Wild Rose Drivel Submittal Item: Shed Style Roof Over Existing Porre,.........._ Approval No.: 5, Dear Mr. Jesse and Mrs. Jill Steindler, The Design Review Board (the "DRB") for Ironbridge Property Owners Association has reviewed the shed style roof over the existing porch for the above -referenced addres The shed style roof over the existing porell,wo,APPROVRD with the following conditions,as provided in the list below,p Within the scope of our authority pursuant to the Declaration of Covenants, Conditions, and Restrictions — Section 16.1 for Ironbridge, and the Ironbridge Design Guidelines, Version dated June 2005, the Committee noted the following: A. All building material will match the existing building materials of the home. B. Ml colors will match the same colors as the existing home. C. The roof pitch of the structure will be at a MINIMUM of 4:12, preferably 6:12 as outlined in the Design Guidelines under section 15. D. The structure will correspond with the submitted plans., IMPORTANT NOTIFICATIONS 1) As outlined in the Design Guidelines of the Declaration of Covenants, Conditions, and Restrictions for Ironbridge ("Declaration"), the purpose of the approval process is to ensure a design consistency in the level of quality and image established for the Ironbridge community. This includes those identifiable and unifying elements that promote consistency within the community streetscape, while encouraging innovation through custom home building. Review and approval of any application is made on the basis of aesthetic considerations only. Strict compliance to the Design Guidelines and Declaration is the sole responsibility of the Owner. This approval only applies to those specific items outlined above. 2) Any contractor, subcontractor, agent, employee, or other invitee of an Owner who fails to comply with the terms and provisions of these Design Guidelines may be excluded from the DRB Approval letter 06/01/05 Page 1 of 2 Deleted: February 24, 2006 feted: September 26, 2005 Deleted: September 20, 2005 Deleted: Jurse 16, 2005 Formatted: indent: Left: 0.5', First line: 0.5" Deleted: (Builder Name)91 (Address) Formatted: Font: Bold Deleted: (Application No.) Deleted: (Address of Submittal) Deleted: (Submittal Items) Deleted: (Approval No.) Deleted: (Builder) Deleted: (list out submittal item Deleted: tat Deleted: Deleted: (Listed submittal items) Deleted: ere Deleted: /DISAPPROVED Deleted: (if approval was conditional) Deleted: 1 Formatted: Bullets and Numbering Formatted: Numbered + Level: 1 + Numbering Style: A, 8, C, + Start at: 1 + Alignment: Left + Aligned at: 1" + Tab after: 1.25" + indent at: 1.25" Formatted: Font: Bold Deleted: di>. (if conditional approval, list out conditions) (If disapproved, list out reasons why) Properties, subject to notice and hearing procedures contained in the By -Laws. Ironbridge Property Owners Association, Inc. has the authority and standing to pursue all legal and equitable remedies available to enforce the provisions of these Design Guidelines and the decisions of the DRI3. 3) Any variance to the Design Guidelines must be specifically identified and requested for consideration by the DRI3. 4) The applicable version of the Design Guidelines is the released version at time of Preliminary Plan submittal to the DRB. 5) Pee & Fine Schedule is attached. ITEMS NOT REVIEWED/APPROVED): • Setback compliance • Size (square footage) compliance • Grading & Drainage Plans (Note: All lots must drain to front street — not to Golf Course, River, Common Area or Adjacent lots) • Compliance to governmental regulations, codes, standards, etc. • Home configuration with respect to utilities (e.g. storm sewer, phone, etc.) • Easement recognition Sincerely, Authorized Representative DRB Approval Letter 06/01/05 Page 2 of 2 1 1:1 SUBJECT TO NOTED X;XCEPTIONS & INSPECTION:' • GARFIELD COUNTY BUILDING DEPARTM Atte 3L) By FIELD COPY INSPECTION \NOHOW/ AlESE PLANS ON SITE NAge neo -Com *o h — A=88'39'12" R=35.00 „/L=54.16 CB=S10'38'05"W C=48.91 wv wv SEWER MANHOLE ,EDGE OF A=10'54'07" PAVEMENT R= 280.00 L=53.28 CB N49'30'38"E 053.20 UTIL. PE i SEWER S MANHOLE ELECT. XFMR, BURIED GAS MARKER REBAR AND CAP LS #19598 (PND.) 4/ LOT 112 ogn SCALE: 1" = 30 CT. METER PVC RISER ROAD SIGN G ro�Q O o WATER SERVICE REBAR AND DAP LS #19598 (PND.) i .�O OQ�Cl 5e AGF REBAR AND CAP LS #19598 (END, LOT 114 NOTE: THIS PROPERTY IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS AND EASEMENTS OF RECORD OR IN PLACE, PROPERTY DESCRIPTION LOT 113, ACCORDING TO THE AMENDED & RESTATED FINAL PLAT OF IRONBRIDGE P.U.D. PHASE 1, RECORDED AS RECEPTION NO. 554210, COUNTY OF GARFIELD, STATE OF COLORADO IMPROVEMENT LOCATION CERTIFICATE I HEREBY STATE THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED BY HIGH COUNTRY ENGINEERING, INC. FOR WELLS FARGO BANK, N.A., THAT IT IS NOT A LAND SURVEY PLAT OR AN IMPROVEMENT SURVEY. PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. I FURTHER STATE THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE, OCTOBER 12, 2005, EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ' PAR SF SAID PARCEL, EXCEPT AS NOTED. 00 co uov 4",:,00111N4.4 HOE Nasfe B Y: JOB NO • 2041020.113 \LOT 113—ILC HIGH COUNTRY ENGINEERING, INC. 14 INVERNESS DRIVE EAST, STE F-120 1517 BLAKE AVENUE, SUFE 101 ENGLEWOOD, CO 80112 GLENWOOD SPRINGS, CO 81601 (303) 925-0544 (970) 945-8676 8/30/03 Single Family Residential Patio Covers SI Carports Directions Address: 1. Fill in the blanks with dimensions and materials which 0 06- E k 05c cwe will be used to build the structure. Please print legibly. Cr4�P,n (IJt 9(j FVi t S re '1.& 22 2. Indicate in the check boxes which details frompag e 3 will be used. Please note if any' f the sides of your carport addition are closer than 3'-0" to the property line, that side of the carport must be enclosed with a solid 1 hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. Zoning approval is required. 3. Roofing to be installed per manufacturer's instructions, including low slope application and required inspections made. Roof covering 111€ l L (example: Class A 3 tab shingles) Size a i r Amouij�t f La s Underlayment 3ef Tc) (example 15ft felt with l B" laps) Sheathing % 7 t& (example: 1/2 exteriorp{ywood) 12 pitch rafters spaced I " O.C. (example: 2 x 8 rafters spaced 24" O.C.) Few der. Existing building fee 2 line Beam splices to occur over posts with 1 t/2" bearing (/ ) L/ "x 12.. "beam (example: (2) 2"x10') Siding ,t1 4J Opal (for Alternate B only) Concrete Slab Minimum Diameter Pier 8" This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2003 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. "x ."posts example: 4"x4") spaced apart (example: 62 Footing . "x' (for Alternate C only)