HomeMy WebLinkAboutSoils Report.pdfHEPWORTH-PAWLAK GEOTECHNICAL, INC.
August 10, 1993
Larry and Dawn Thrun
P.O. Box 883
Silt, Colorado 81652
7840 Highway 82
Glenwood Springs, CO 81601
Fax 303 945-8454
Phone 303 945-7988
Job No. 193 151
Subject: Observation of Excavation, Proposed Residence, 8000 County Road
117, Garfield County, Colorado.
Dear Mr. and Mrs. Thrun:
As requested, Hepworth-Pawlak Geotechnical, Inc. observed the excavation at the
subject site on July 29 and August 4, 1993 to evaluate the soils exposed for foundation
support. The fmdings of our work and recommendations for the foundation design
are presented in this report. The work was done in accordance with our agreement
for geotechnical engineering services to Larry and Dawn Thrun, dated July 29, 1993.
The proposed residence will be a 1 1/2 story wood frame structure above a walk out
basement level. The garage will be on the upper main level.
At the time of our initial visit to the site, the foundation excavation had been cut in
two levels from 1 to 6 feet below the adjacent ground surface. The garage and
basement areas essentially daylighted to the west from their respective excavation
levels. The soils exposed in the bottom of the excavation were variable and consisted
mainly of clayey gravel with cobbles and boulders in the lower level and soft wet
clays in the upper (garage) level. The northwest corner of the basement frost depth
footing trench was based in organic sandy clay. Probing with a steel rod indicated the
clay depth is 1 to 3 feet in the garage area and one foot in the northwest basement
corner below footing cut grade. Results of consolidation testing performed on
samples taken from the site, shown on Fig. 1, indicate the clay soils are moderately to
highly compressible under conditions of loading and wetting. The test results are
summarized in Table I.
Most of the excavation was cut below the groundwater level, and drain gravel and
perforated pipes had been installed to collect and divert the water seepage to the north
of the building. The clays in the garage area were generally soft and wet and it was
recommended to construct an intercept trench drain just uphill of the garage. When
Larry and Dawn Thrun
August 10, 1993
Page 2
observed on August 4, the trench drain had been installed and the water seepage flow
in the garage footing area had essentially stopped. The water seepage from the uphill
basement cut had also diminished from that observed on July 29.
Considering the conditions exposed in the excavation and the nature of the proposed
construction, spread footings placed on the undisturbed natural soils and drain gravel
backfill designed for an allowable soil bearing pressure of 1500 psf should be
adequate for support of the proposed residence. The wet black clays in the garage
area should be subexcavated and replaced with drain gravel. The gravel backfill
should extend 1 to 2 feet beyond the edge of the footing. Footings should be a
minimum width of 18 inches for continuous walls and 2 feet for columns. Loose and
disturbed soils encountered at the foundation bearing level within the excavation
should be removed and the footings extended down to the undisturbed natural soils.
Exterior footings should be provided with adequate soil cover above their bearing
elevations for frost protection. Continuous foundation walls should be reinforced top
and bottom to span local anomalies such as by assuming an unsupported length of at
least 12 feet. Foundation walls acting as retaining structures should be designed to
resist a lateral earth pressure based on an equivalent fluid unit weight of at least
50 pcf for on-site granular soil backfill (excluding rock greater than 8 inches). A
perimeter foundation drain should be provided to prevent temporary buildup of
hydrostatic pressure behind the walls and prevent wetting of the lower level. The
drain gravel should extend to above the line of wetting in the excavation face. Garage
floor backfill can consist of the on-site gravelly soils compacted to at least 95% of
standard Proctor density at a moisture content near optimum. Backfill placed around
the structure should be compacted and the surface graded to prevent ponding within at
least 10 feet of the building.
The recommendations submitted in this letter are based on our observation of the soils
exposed within the foundation excavation and do not include subsurface exploration to
evaluate the subsurface conditions within the loaded depth of foundation influence.
H -P GEOTECH
Larry and Dawn Thrun
August 10, 1993
Page 3
This study is based on the assumption that soils beneath the footings have equal or
better support than those exposed. The risk of foundation movement may be greater
than indicated in this report because of possible variations in the subsurface
conditions. In order to reveal the nature and extent of variations in the subsurface
conditions below the excavation, drilling would be required. It is possible the data
obtained by subsurface exploration could change the recommendations contained in
this letter.
If there are any questions or if we may be of further assistance, please let us know.
Sincerely,
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
Steven L. Pawlak,
SLP/ro
Attachment
H -P GEOTECH
-alj
S11f1S3d 1S31 NOI1V0I1OSNO0-113MS
oil '1V3INH33103J
)IV1MVd-HJiJOMd3H
1.91. £61,
is)l — 31:1f1SS3 dd 0311ddV
oat Ot 01 t'0
5
b
£
6uiTIeM
uoissaadwop
uodn
Compression %
N — 0
NO,
aullooj
aauaoo
ARID
&'puss
wawaseq
;saran-low :wo d
oIUe6JQ
pd
wowed
b•
96
t
to aidwes
= 1t13 aM pun Ain
= luatuo3 alnlsiotiy
0ot
)S)1 — 31:1f1SS9EJd 0311ddV
of (it c0
0
E 0
ID
ID
6ulllan uodq
quawanoW ON
in
0
.6-g
+
I
6ulgooj abeieb IIPM Banos
:wo J
API3 £2IIS
0
:loaldwes
lad LOI = 146iaM pull Aio
luaaJad I, • 61, = lualuo3 a)nls!on
0)
c
0
m
r
D
0 —1
OD
W
—DIm
O -
cn
N
r
cncn
o
w
0
m
0
J
01
J
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
Northwest
Corner
Basement
Footing
South Wall
Garage Footing
North Wall
Garage Footing
SAMPLE LOCATION
N_
:piO
Na
co
11
NATURAL
MOISTURE
CONTENT
(%)
co
O
O
V
co
co
NATURAL
DRY
DENSITY
(pcf)
c
m
r•0
0
Z
Z
N
.R2
0
PERCENT
PASSING
NO. 200
SIEVE
.
"' i 5
4 O
1 ATTEBBERG LIMITS
2
deON
UNCONFINED
COMPRESSIVE
STRENGTH
IPSFI
organic sandy clay
silty clay
organic silty clay
SOIL OR
BEDROCK TYPE
0)
c
0
m
r
D
0 —1
OD
W
—DIm
O -
cn
N
r
cncn
o
w
0
m
0
J
01
J
HEPWORTH-PAWLAK GEOTECHNICAL, INC.