Loading...
HomeMy WebLinkAboutApplication-PermitProject Address Garfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81501 - Phone: (970)945-8212 Fax: (970)384-3470 000550 11TH ST W RIFLE, CO Parcel No. 217709300003 Subdivision issue Date: 7/2212010 Section Expires: 01/18/2011 Township Range Owner Information Address F�hone Cell Garold Warren 4,4 550 11th ST Rifle CO 81650 970-625-3963 Contractor(s) Phone Primary Contractor Golden Villa Homes (970)245-9039 Yes Proposed Construction / Details New HUD manufactured home & demo existing FEES DUE Fee !mount Manufactured Building Fee $125.25 Plan Check Fee $81.41 Single - Manufactured Home ; $400.00 Total: $606.66 Valuation: Total Sq Feet: $ 5,760.00 1230 FEES PAID iV Total i. Paytype ,:;Amt Paid At111 Due Inv # BLMF-7-10-20359 $ 606.66 Check # 2183 Check # 2179 $470.65 $136,01 $ 0.00 Required Inspections: For inspections cal[: 1(888)868-5306 nspection NR See Permit Record Building Department Copy Thursday, July 22, 2010 2 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-82121 Fax: 970-384-3470 / Inspection Line: 970-384-5003 www.gartield-countv.cotn 1 1< Parcel No: (this information is available at the assessors office 970-945-9134) air -no 9 3 Oboc)3 2 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description SSd tom. t t4—`' t Rpt ottoS0 3 K Lot No: Block 5 t ,q tiftc.> ,:..to it.GGAI. Mt , No: Subd./ Exemption: 4 A Owner: (property owner) Ga9.01-0 WAR Mailing Address: S5c, w. 11ats St PIFLfICo Ph: q lo-(aT39(03 Alt Ph; 5 Contractor: Goll...Otsi lit U.., iornts Mailing Address: a41s -k(G. k sb (....3;(0816-a Ph: InWV") 970-atoo- Baa 9 Alt Ph: q7-1&-9 6 2, Architect / n eeeer) Mailing Address: Suat P.D.Bo. t -75'a Vtat4A4-3UT Ph: 4SS'-7$9.5448 Alt Ph: Vf geE It1146 7 Sq. Ft. of Building: ►a3c, Sq. Ft. or Acres of Lot: d, 3t3 fl(a5 Height: ftp` -c. No. of Floors: 8 Use of Building: St14trtA FATh t( g€S)OtJ.1cE 9 Describe Work: Niro 1-1u0 OrNANvcocrucetc, 3-1om£. t DQlfo Xt5TiNC, % o1M - 1 0 Class of Work: VNew o Alteration o Addition 11 Garage:I t.//4 o Attached o Detached Septic: ext rsN& 'p' SDS o Community 12 Driveway Permit: Owners valuation of Work: $ [; , 1 `t Authority. This letter application for a Building Permit must be signed by of authority, signed by the Owner, must be provided A Building Permit cannot be issued without proof of Multiple separate permits may be required: (1) State NOTICE the Owner of the property, described above, or an authorized agent. If the signature below is not that ofthe Owner, a separate with this Application. legal and adequate access to the property for proposes of inspections by the Building Department, Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or Discharge Permit authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans based upon my certification as to accuracy. a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, are not in compliance with County Regulation(s) or any other applicable law. described above, to inspect the work. 1 further acknowledge that the issuance of the Building Permit does not prevent the if any, discovered after issuance; or (2) stopping construction or use of the stricture(s) or facility(les) if such is in violation work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without THE NOTICE & CERTIFICATION ABOVE: S- /d Legal Access. Other Permits. Void Permit. County Highway! Road Access or a State Wastewater A Building Permit becomes null and void if the work days after commencement. that I have read this Application and that the information and other data submitted by me or on my behalf (submittals), of the submittals and approval of this Application, reviewed by the Building Department, of the issuance of the Building Permit, I agree that 1 and applicable land use regulations (County or use of the structure(s) and facility(ies), described above, permission to the Building Department to enter the property, from: (I) requiring the correction of errors in the subtnittals, or any other applicable law. Application, including submittals, and inspections of the As the Owner, I acknowledge that responsibility for architect designer, engineer and/ or builder. ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND iAlen I hereby certify and specifications Assuming completeness the submittals In consideration Code, ISDS regulations construction I hereby grant Building Official of County Regulation(s) Review of this or discrepancies. limitation my 1 HEREB OWNERS SIGNATURE DATE STAFF USE ONLY Special Conditions: Adjuster) Valuation: S,76o 08 flan Check Fee: v.W Permit Fee: /Zv 25- lVlanu home Fee; y00." Mise Fees: ISDS Fee:Total Fees: 606, .66 Fees Paid: - `� ) Balance Due: 117a k' BP No & Issue Date: ISDS No & Issued Date: -1 (L9N- Setbacks: ` F 23 12, 1 z,5o to OCC Group: g Const Type: 6 �r�i u�,) Zoning: L BLD G DEPT: ,c e to -fry - 1 7i4 f IQ PLNG DEP : ,00,44x,S 094 APPROVAL DATE APPROVAL DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. /T012411 ) OWNERS SIGNATURE Bapplicationdecember2007 DATE VALUATION FEE DETERMINATION Applicant Garold Warren Subdivision NIA Address 550 W. 11th St. Rifle Lot/Block N/A Date 7/19/2010 Contractor Golden Villa Homes Finished (Livable Area): Main sq.ft Upper sgJt Lower sq.ft Other sq.ft X $74.68 Total Square Feet 0 sq.ft Valuation Basement: Unfinished sq.ft X $41.00 Conversion of Unfinished to Finished sq.ft X $33.68 Total Valuation Garage/Storage (wood framed) sq.ft X $18.00 Carport: sq.ft X $12.00 Total Valuation Crawl Space Total Valuation Z91/577/✓f sq.ft X Decks/ Patios/Porches Covered suit X $24.00 Open 480 sq.ft X $12.00 Total Valuation Commercial Type of Construction: Occupancy: 0.00 0.00 0.00 0.00 5,760.00 sf X sf X sf X sf X sf X sf X Valuation 0.00 Total. Valuation 5,760.00 Building Plan Review Description of Work: New HUD manufactured home & demo existing Bin #: Location Address: 000550 1 ITH ST W RIFLE, CO Genera Information Contacts' Case Manager: David Bartholomew Plan Case Number: BLDG -7-10-6506 Parcel: 217709300003 Application Date: 07/15/2010 ,..moo Building Owner: Garold Warren Applicant: Garold Warren Applicant Phone: 970-625-3963 Emelt Engineered Foundation Driveway Permit -.;Surveyed Site Pian - N7A — Septic Permit and Setbacks Grade/Topography 30% ^fp Attach Residential Plan Review List Minimum Application Questionnare Subdivision Mat Notes •)//_.. Fire Department Review Valuation Determination/Fees l / Red Line Plans/Stamps/Sticker Attach Conditions Application Signed ian Reviewer To Sign Application __,,.ParcellSchedule No. 40# Snowload Letter - Manu. Homes Ni 4Soils Report PlanninglZoninq Property Line Setbacks 30ft Stream Setbacks Flood Plain Building height Toning Sign -off it1G Road impact Fees ~` ` HOAIDRC Approval .-.__....._-...Grade/Topography 40% lanning Issues -Subdivision Plat General Comments:. 1/4.1,4,1b2• ' 5/ 760 . ©U Pemiti I- Pee ge-viv/i Pee- h t Boa.vo 66 P�1o"I Applicant: Job Address: Subd- Lot/block: wilVl (A. lGtawaJ FEE ESTIMA7�E FOR S/F STICK B UILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL PLANS ARE REVIEWED) Q L b w A (22t1 FINISHED LIVING SPACE: UNFINISHED BASEMENT: RAWL SPACE: GARAGE: 1 a3t> sf X 74.68= 'Ct ! %S L L. L jD sf X 41.00= sf X 9.00= � �-�- � W.) -- sf X 18.00= UNCOVERED PATIO/DECK: COVERED PATIO/DECK: MISC: MISC: Lig() sf X 12.00= S 1 top sf X 24.00-= 1 7-0 TOTAL VALUATION: THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: /c SEPTIC= PERMIT: PERC: GARFIELD COUNTY BUILDING Al\ 970-945-8212 D PLANNING MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2003 IRC, and 2006 IECC. 1 Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. �r Yes X 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties)) streams or water courses? Yes iC 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes X 2 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? Yes if Yes please provide a COPY. No 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes X 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes X No 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No X 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes X 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 13. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes NC„ , 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and cave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes X 3 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase 11 EPA certification? Yes No 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes X 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes X No 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes 23. Will this be the only residential structure on the parcel? Yes )( No If no -Explain: 24. Have two (2) complete sets of construction drawings been submitted with the application? Yes 4 25. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes X 26. Have you designed or had this plan designed while considering building and other construction code requirements? Yes 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes 29. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes X No 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -inspection fee? Yes 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes 5 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes �C 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes 39 . Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes K 40. if you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes hereby acknowledge that 1 have read, understand and answered these questions to the best of my ability. Signature of Owner 7'-16 Date /0 Phone: q.-7 - (a - 39 (03 (days); (evenings) 6 Project Name: GRIZ4c-0. u..flGaRZM DIA Cf - Project Address: SSC' �t� St X11 cut tp albs Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminregsfMar2009 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, 2006 IECC. Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof! Not ground): 40PSF up to 7000ft. elevation. 50PSF 7001ft to 8000ft. 75PSF 8001 ft to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe. Termite infestation probability: None to slight. Wind speed: 90mph. Decay probability: None Wind Exposure: 13 or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building official Ice shield under-layment required. Mean Annual temp: Variable Insulation: Windows/doors U=.35, Skylights U=.6, TBL 402.1.1, 2006 IECC. Minimum R -Values: • Ceilings/roofs R values are R-38 stick built structures. R38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing or R-10 sheathing for steel studs. • Floors R -values are R-30 or enough to fill cavity. • Basement wall R -values are R-10 below grade, R-19 above grade. • Slab perimeter R -values and depth is R-10/24in • Crawl space wall R -value are R-10 below grade and R-19 above grade. If floors over crawl space are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. bpminregsfMar2009 8 Permit Card Garfield County Building and Planning Department 108 8th Street, Suite 404 Glenwood Springs, CO 81601 Phone: (970)945-8212. Fax (970)384-3470 POST ON SITE Permit NO, B L M F -7 1 O 163 I Issue Date: 712212010 014 atclarficairil Expires: 01/1812011 AGREEMENT in consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Manufactured Building Parcel #:217709300003 Owner's Name: Garold Warren Job Address: 000550 11TH ST W RIFLE, CO Owner's Phone: 970-625-3963 Total Square Feet: 1230 . 11.,144 , Gontractor(s) Golden Villa Homes Phone Primary Contractor (970)245-9039 Yes Work Description: Inspection Scheduling Code Ll ���yy C.ni�fM, ..+.Fn','�r�+�;k+, i- �Yv .. (k�x�..��.n .F pp �4 i..A.�S 4G\. ro'i'G"`�firay jayty+.�' �� ,,. c v+r. 'r- . .... . .,,,....c �..r+k_�+r#c0.l_;��. 5 .-,w,.. ,:0? -,Ago r.,.�S.'..�1�� Nn. �F ! ��•,'.i: "5 �j�'��✓ }}� �,4 FM �'tloC r yy.�5t�. c�,1 _ )�:'.`L �:fJi/�j`�/S�_._ a,;?d n ....�.. .SFa�. .. Y{'��S , R..�rt e { -...�w �` YnHIGH .3u jp Yi'" .Y 5 t1 f i+.,��, - Na V V.M '$' "— � yv . �j-..9 ��.�...�a. .�_.�._, �...c.� l cY 3.f.� .L'✓iJ.'t�., 3`�`' Yf:; {.y ,���*, ...,.,.�. �4i°k� Footers `�T.UT FwOV �y/�f Js CY" f J / ' �f / .tl:.. ' ✓ i ^y 2 -,2v-2.-. / �� ��,-1� Foundation Walls ���ff/j-� r Final . a 'gl - - 4 C r 4, 1 , "/ Cy Q ae``�. Rough Plumbing5 5VMi1„,trj�i , Gas G' Neimg,o/&19-z Chi 4°4r -a#so3 F Com) FL-FATNLL- ivy 014 ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For inspections Call: 1-888-868-5306 4S {:5;740,F ...Mi ..... r.Z...., r.,,.''N:RWI ' i'''' -ii' 13,,,:'''','... c .-f....E ,� ,.:. . ni Address 000550 Street Direction W Street 11TH Street Suffix ST Vicinity RIFLE Business Name N/A Subdivision Name N/A Block N/A Lot N/A Condo Name N/A Condo Unit N/A Dwelling Units 1.00 Acres 2.313 Land Sq Ft N/A Owner WARREN, GAROLD Care of 1 NIA Care of 2 N/A Owner Address 550 WEST 11TH STREET Owner City RIFLE Owner State CO Owner ZIP 81650 :, , t „ Assessor..:, Parcel Number 217709300003 Tax District 21 Tax Exempt Entity PRIVATE OWNERSHIP City or County Unincorporated Garfield County Zoning Description Resource Lands Land Use 1 SINGLE FAM.RES-IMPROVEMTS Land Use 2 SINGLE FAM.RES.-LAND Land Use 3 N/A Land Use 4 N/A Land Use 5 N/A Reception No 769621 Book NIA Pa ce N/A -- Legal Description Section: 9 Township: 6 Range: 93 PARCEL PREV. DESC IN BK 1273, PG 384 !N THE NWSW. ALSO A TR. OF LAND CONT.086 AC /- AS DESC. IN BNDY LINE ADJ. AFFIDAVIT FIEC#769623 & OCD 4769621 & 769622 —WA ------- Section Township N/A Range N/A Jul. 8. 2010 2:35PM Garfield County Road & Bridge No, 4509 Golden Villa Homes Shawn Ruse 2475 Hwy 6 & 50 Grand Junction, CO 81505 Mr. Ruse, Garfield County Road and Bridge Department July 8, 2010 This letter is to confirm that you do not need a Garfield County Driveway Permit for the property located at 550 11t St, Rifle, CO 81650. Even though the actual property is in unincorporated Garfield County, the access is off Eleventh Street which is within the Rifle City Limits. Due to the above situation, any access or driveway permits will need to be obtained through the City of Rifle. If you have any questions or need further assistance, please call. Sincerely, J Kraig Kuberry Assistant Road & Bridge Director Garfield County cc: Building & Planning Department File 0298 County Road 333A; P.O. Box 426 Rifle, CO 81650 Phone: 970-625-8801 Fax: 970-625-8627 BOARD OF COUNTY COM MISSXONERS OF GARFIELD COUNTY CERTIFICATION AND AFFIDAVIT REGARDING ILLEGAL ALIENS The Contractor, whose name and signature appears belCw, certifies and agrees as follows: 1. The Contractor shall comply with the provisions of C.R.S. 8-17.5-101 et seq. The. Contractor shall not knowingly employ or contract with an .illegal alien to perform Werk for the Board of County Commissioners of Garfield County, Colorado ("BOCC") or enter into a contract with a subcontractor that knowingly employs or contracts With an illegal alien. 2. The Contractor represents, warrants, and agrees that it.'has Verified that it does not employ any illegal aliens; that it has participated or attempted to participate in the Basic Pilot Employment Verification Program administered by the Social Security Administration and Department of Homeland Security; and otherwise shall comply with the requirements of G.R.S. 8-17.5-102{2)(b) 3. The Contractor shall comply with all reasonable requests made in the course of an investigation under C,R,S. 8-17.5-102 by the Colorado Department of Labor and Employment. If the Contractor fails to comply with any requirement of this provision or C.R.S. 8-17.5-101 et seq., the BOCC May terminate Work for breach and the Contractor shall be liable for actual and consequential damages to the State. 4. If the Contractor is a sole proprietor, the undersigned hereby swears or affirms under penalty of perjury under the laws of the State of Colorado that (check one) I am a United States citizen, or airt a Permanent Resident Of the United States; or: I am lawfully present in the United States pursuant to Federal law. I understand that this sworn statement is required by law because I am a sole proprietor entering into a contract to perform work for the BOCC. I understand that state law requires me to provide proof that I am lawfully present in the United States prior to starting work for the BOCC. I further acknowledge that I will comply with the requirements of C.R.S. 24-76.5-101 et seq. and will produce the required form of identification prior to starting work. I acknowledge that making a false, fictitious, or fraudulent statement or representation in this sworn affidavit is punishable under the criminal laws of Colorado as perjury in the second degree under C.R.S. 18-8-503. CERTIFIED and AGREED to this c26 day of CONTRACTOR: GoLotto Vg -L4 ails iti o auNtE , 2010, lal(0%3°i (Contractor Full Legal l'iare) FEIN or Social Security Number By: gnature of Authorized Rep Title Ivr;ttax'tion F?ffJdi',jf (08/O61 Final EXMTh IT 108 8th Street, Suite 401, Glenwood Springs, Co 81 Phone: 970-945-82121 Fax: 970-384-3470 Inspection Line: www.Rarfield-county.com 5 t t g P' 2%i 70-384-5003 LACE_ GARFIELD COUNT( SEPTIC PERMIT APPLICATIQ 1 Parcel No: (this information is available at the assessors office 970-945-9134) 011101S0b0 3 """-- 2 Job Address: (if an address has not beenassigned, please SSo ti, ! 1tt 5� provide Cr, Hwy or Street Name & City) or and legal description SZ1cLti. CO lla5-0 Block No: Subd./ Exemption: 3 _ Lot Size: Lot No: A' 3 Q; �, 4 Owner: (property owner) Ca 2ac.,0 2R�� Mailing Address SWo W. I 44.Si 1Pu Co Ph: 9 76-1.07S-3163 , ....... , Alt Ph: SA -wt . 5 Contractor: Mailing Address i' Ph: Alt Ph: 6 Engineer: Mailing Address Ph: Alt Ph: 4110 PERMIT REQUEST FOR: () New Installation ( ) Alteration () Repair WASTE TYPE: pltwelling ( )Transient Use ( )Commercial or industrial ( )Non- Domestic wastes ( )Other — Describe 9 BUILDING OR SERVICE TYPE: SF ft Number of bedrooms s Garbage Grinder ( )Yes c)No 10 SOURCE & TYPE OF WATER SUPPLY: ( )WELL ( )SPRING ( )STREAM OR CREEK ( )CISTERN If supplied by COMMUNITY WATER, give name of supplier: CtTtt OF Air Lk_ 11 DISTANCE TO NEAREST COMMUNITY SEWER Was an effort made to connect to the Community System? SYSTEM: YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: Depth to 161 Ground Water Table Percent Ground Slope 13 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS} PROPOSED: (*Septic Tank ( )Aeration Plant ( )Vault ( )Vault Privy ( )Composting Toilet ( }Recycling, Potable Use ( )Recycling, other use ( }Pit Privy ( }Incineration Toilet ( )Chemical Toilet ( )Other- Describe 14 FINAL DISPOSAL BY: (?QAbsorption trench, Bed or Pit ( )Underground ( }Wastewater pond ( }Other- Dispersal ( }Above Ground Dispersal ( }Evapotranspiration ( }Sand filter Describe 15 Will effluent be discharged directly into waters of the state? ( )YES NNO 16 PERCOLATION TEST RESULT; (to be completed by Registered Professional Engineer, 4 the Engineer does the Percolation Test) Minutes per inch in hole No.1 Minutes per inch in hole No.3 No._ Minutes per inch in hole No.2 Minutes per inch in hole Name, address & telephone of RPE who made Name, address & telephone of RPE responsible soil absorption test: for design of the system: 17 Applicant acknowledges that the completeness of the local health department to be made and furnished issuance of the permit is subject to such terms and reports submitted herewith and required to be submitted and are designed to be relied on by the local department understand that any falsification or misrepresentation and legal action for perjury as provided by law. the application is conditional upon such further mandatory and additional lest and reports as may be required by by the applicant or by the local health department for purposed of the evaluation of the application; and the conditions as deemed necessary to insure compliance with rules and regulations made, information and by the applicant are or will be represented to be true and correct to the best of my knowledge and belief of health in evaluating the same for purposes of issuing the permit applied for herein. I further may result in the denial of the application or revocation of any permit granted based upon said application {iii i DATE 7.- l6--- OWNERS SIGNATURE Jj ��� STAFF USE ONLY Permit Fee: Perk Fee: Total fees: Building Permit #: Septic Permit #: Issue Date: Building & Planning Dept: APPROVAL DATE ,SEE, 8.2010sj12:40P "''''t*GOLDEN VILLA HOMES NO. 373 _ Yll of 1 COLORADO STATE' ELECTRICAL BOARD INSPECTION REPORT 1 CORRECTION NOTICE DaW Received: 03 -SEP -10 Permit Number: 693207 Contrector!Homet er: T & M ELECTRIC Address; 550 west 11th st Type of Inspection; Complete Filial Aetion: Accepted Comment or Carreotions: Inspectors Name; Cyrus Tuchscier Phone Number; 970-825-5055 Date; Q3 -SEP -10 COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Pions: (303) 894-2985 https://www.d.ora..state,co.us/pIerealp_Web Tngpeetion GULPraaess Page 9/7/2010 `, 9,4d-47 vJ >v� ..J1.-'C.a IS 6 X 5 w "d • 1 0 a ttCo X4. la IL' 0 5 0 ca c �Am m F w ***BUILD WITH 2X6 EXTERIOR WALLS*** 39 38 37 35 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 9 7 6 5 4 3 2 i 0 # i l l i# 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1.I 1 I I E 1 I 1 I 15'-3 5'-0 4! 147 29S2ER !!S5000 188.7 see 3060-5 ENING ROflO 109.2 50 19'-6 .3636 KI184641 100.9 sq{ 1 1# 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 39 38 3? 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19.19 17 l6 15 14 13 12 11 10 9 8 7 6 5 4 3 2 t 0 4454 'xou4 5€14404 944444 .5 to 1-m CUSTOMER WARREN MODEL: 1051ELM24523A WINDZONE1 1 ROOF LOAD; 400 51DEWALL5: 9611 RET500 404 410818EnENT3 I 20-. ie' uR I(( RE05IR(0 <7)09010;515 854214(3 4491.9 44 51505 IR (0504€ 4'5 10. 50414. 94 2 1,2 €300 424044541 0144 • 915141(511611 142304 0)009A 5) ruSi K 04024841 2 1,2- 0111. 1544 ?E 03 00(15 IN 04884 j 4'x29' 0.2 6'oN' 1804.1 K051120 IN (014005 0 51RI25 CLAYTON 1H24 0(41 5 1 0 44 5 G t 9 E R R 1. 44 6 5 E 5 CMH MANUFACTURING, INC ((011RG Kip1T . 55.00 REFER 1016P10 RM£ t0S-2.0 FOR pail t 1640 1 15414 REFER 10 Of914 4444( (1-1-2 504 5254. 50420( 6 1126444 510444u11 444438 41491 (4091! 5PWO* e €6 4044, 4140044 911 + 124.5 467 9251154 1114E MASTER PLAN 9542174138 443144. 90. 24x56 3BR-2BR BuC0O30IG 5015544 84 464344. 211( 19115 R41141EO 8441(1 442 - HM 06i22i2010 06723/2010 1-1 KIT SiTT7( Kli SINS GLAMOUR 13ATH 1H©T WRIER SUPPLY PLUNBING1 PIPE LEGEND WW LL HY T ON i1H2 T RE SiONS Li NERRE naIls CMH MANU ACTUR I NG , INC, 1465E 31385 YER SKCS CI4Af[14G TULE SUPPLY #2 EL TTHRfTGE 1213 FEW, 553 OESL4i9TNN 24x55" 38R -29H rWai. ro. 1 051 ELM24523R 9+ Ht MG. RITC 06/16/2010 A'11C mini D 06/22/2010 s£E1 no. 9-2 26' -10 - WATER 29'-I13 G85_ 1 1 I 1 1 1 I t 1 I 1 I 1 } 1 I i 1 11 ^i 20'-0 iib' LELEC T E 1 �0 -b D91V JROP { 20'-$1 718' t20 -1i 718•) 4S67ILOS 1 C i 1 \. I 1 i -1. 1 1 I' 3 518 I 1 1 - it' -5 58/8') -jar' i 9667 LHS ,t --i 1 1 1- 39' 10' DSIV MOP -I I I I i I I ( I t 1 ter. 1 I I i 1 1 I 52'-0" SERVICE ENTRANCE LEGEND = ELECTRiC(L 0ROP O. NATER 1010) ® = cwv Powioioc ORO' El. 000 1771E7 NOTE: ALL LOCr1T1005 RRC A Pt0Ox1rs7TC 00.71,1.10010 11 71101100 YER771.71i1W1 10 �0 60 111 11. Ix. 07 YCNI 108 (ART 107 50. OT 0010.011( 1050 11170 00P807l0 001100 (50000(0. 00110011L 0E ' 1 0E07 1-7151 05 01111110 3 n, 9C [RCM COATER 121) $0. CT. 01 CORLTIVa. RPEA 583 SO. 11. Of 15111 0(0111/0 11 3C11tS 10(050 8 02 09. IN. EACH 621 5S. IA. VEN(1L011IXV I181AL1(0 01011551 1p IC: 10E 8.000801I01 KIWI( 0 23'-1- 15 I0E013(1 I0 1311 0115001 10000 111218 Of 070 77771.-. 1011 101050071011 100 bE (6115100 E0 00' TO 1 1/2' 011:0511 00 5001106401 1000 000001)01 0 R 0555710.1 w01 10 (52'-4-) 18100 15(010 ®• 98011)01 01 01071016 (-01001 • SUPPORT ttv0(0 ,11971RG R1L ❑• SUPPORT 1110(0 0111 IRS 00(8100 5018001 RT PCR5RiR8.C(00(3 £0001 �• SWPORI 1110£0 MIR i-3(100 es• 500001 101058 P50111. CR R 1 - 5118000! RI (ROSS 1-0(08 SsISC11EN1 RRA*0 CLAYTON SERIES MH29 CMH MANUFACTURING, INC. R 5 0 1 0 1 0 N s 001 BATE G C.N [ R A L 11 0 1 0 0 YOoT Iol 0180 'M' 81550 011 5611 8[0011,1) 510501IT 000 P150 110005 0.1150 09 11519AR1111 TANA, 100 PROPER 111.31)0 010100 l 1 - 01151.5105 01113110 2006 1111(5 OP; VP 10G 11711 PIER SET 99 112 BEAM SPACING (11111 .+a0E EL MiRRGI 40. 1T. 1213 57.Rv1 951 001/02011100 207756' 38R-2BH HOS( 00. 105iEL121523R 11'4011'1 01 HM GRIL. 0110 C631C 17RINI(0 06/16/2010 06/21/2010 51001 1114, 21-P5-99 W/H 42M DIU DRYER 30H BTU INLET FROM HITCH END cc 29'_10" RANGE 54M BTU 1/2" x 40' Column 320MB10 (MAX) 228 HS SHOWN FP 321? BTU FR?W¢ CLAYTON MH24 RE, 550115 GEUL NOTES CMH MANUFACTURING, INC. 1" HIS &CCM SJNIS:1EO FR PIPE ©irD.iilEpS SKIT sv vii vt5 S FLEX U N,((I Im5 PER 3280.705 STIP LEG 0 taitO 1E OPER via 050050 oARs 005t000 RE031050015 0.00056 311 GAS SCHEMATIC L MIRAGE 00. 01. 1213 ALA. SER10110N 24X56" 39R-2 1m. 1051 024W311 101. 00 NM 0015. ROIL 06/16/2010 ORE 0000150 06/21/2010 10--1 12 CLAYTON 39 38 37 3-0 35 3. 13 32 31 30 29 28 72 26 25 24 23 22 21 22 12 18 17 18 15 14 13 12 11 10 1111111i11111111111111111!111111I111 111 521 52'-0' WI EA SIOCHRLL 9 -7 6 FLEX OCT - 5 x 19 x NOME 1 7 6' P LEX CQ ME MU t■fes■■NI �■■■I■�■■■1■■ ikIIIIiIIIIHhII 020CH777 1027 15' 111 02r 7222241 1111111111111111111I11111111111111111111 20 34 77 36 35 34 33 32 31 30 29 20 27 26 25 24 23 77 21 20 19 18 17 26 15 14 13 52 11 20 9 7 7 22 5 4 3 2 1 0 CRI MA1NUFACTURING, INC. 9S1 C£SCR171209 .24X56' 3 26 la_ 210.1E 06/16/010 143017 00. 1051ELE124$23A 031E 211,11719 06721/2010 [COLO WRIER SUPPLY PLUMBING' N/H *1N CU1-OFF NSI-',;{ KIT SIN{ KIT 5[I& UMO CLAYTON 5[RICS MH24 GLAMOUR BATF PIPE LEGENE] I" 374.. GENE RA L NOTES CMH MANUFACTURING, INC. w5Z si8N PV 9,V_5 SUPPLY f I L UMI3 I NG roXL WIZ EL M[REGE 1213 POET 95 CESCRIPtIGN 24X56" 3BR-2BF PO[EL H0. W51ELN24523R gr M M6. Okl ( 06/16/2010 MTE Yn'WE6 06/22/2010 9-1 0 46464 .0 • 6 V. 6 6 FOUNDATION PLAN GOLDEN VILLA HOMES w "9:1 Model # 1051ELM24523A Box Width = 480 " Box length W 52 fi. (1) 24"Skylights@: 30', 48" Front porch Joist Size = #2 spf 2x8 Wind Zone 1 Standard Roof Diaphragm Construction: Shearwatl Dist.! Hitch Length A 0' 84" B 51' 84" SHEARWALL DESIGN - HUD Joist Spacing 16" Double wide No Offset Sox 99.5" 10' MIN-iBEAM No Clerestory No Origami Dormer No Sunken Floor Lags 9Mx3" No Parapet Roof Version R1.5.9 (3/8" sheathing only with 1498. @ 6/6 ac) 1172 p8) Chords: 2x4 63 SPF Rail w/ 2x4 plate: spiced with pair of 3'x6" 20 Ga. connector plates PLF #of Joists Lags Notes 210 2 111 Start at marriage wall 90 inch sidewall 210 2 111 Wind Zone 1 Standard Roof (318" sheathing only with 14ga. @616 ac)[172 96 inch sidewalk pit] Chords: 2x4 63 SPF. Rail w/ 2x4 plate: spliced Diaphragm Construction: . with pair of 311x6'20 Ga. connector plates Shearwall Dist./ Hitch Length PLF # of Joists Lags Notes A 0' 88 " 210 2 2/1 Start at marriage wall 8 51' 88" 210 2 211 Wind Zone 1 Standard Roof (318" sheathing only with 14ga. @ 6/6 oa) [172 pl1j Chords: 2x4 #3 SPF Rail w/ 2x4 plate: spliced Diaphragm Construction: with pair of 3"x6" 20 Ga. connector plates Shearwail Dist./ Hitch Length PLF # of Joists Lags Notes A 0 96 " 210 2 2/1 Start at marriage wail B 51' 96" 210 2 211 102 inch sidewall Wind Zone 1 Standard Roof (318" sheathing only with 14ga. @ 0/0 vc) j1/2 108 inch sidewa€i elf! Chords: 2x4 63 SPF Rail wI 204 pfale: spliced Diaphragm Construction: with pair of 3"x6"20 Ga. connector plates Shearwalt Dist./ Hitch Length PLF 5 of Joists Lags Notes A 0' 100" 210 2 2(1 Start at marriage waft 5 51' 100" 210 2 2/1 1051 ELM24523A_skear_calc Designed by rIN1 0/21(2010 Iar e — �1C141 fn'- E" m,n Sppo