Loading...
HomeMy WebLinkAboutPlansAdo 3,7/d2t2 B66Z-EI-B 3fla ill'B IVa°I8 yin°5 alien al!!l.I 15 u4611!wail 18E rei Moan P°0M alaagai 'za a1-auaaaw 4 0 ; z >-, 9%0 -41555114N10°' - 4,1 1.4 UNCOVERED DECK POSTS AND PIERS LOCATION 03814 Remington St, Rifle CO 81650 .17's ,."X" , , •• ' Rcrlitue vi4-7-1287/97-51D z-429, columns 1,0101- 4/ 4 TilareD 12003 044 0/44 -DARE og., giqr-re4-- Single Family Residential Uncovered Decks and Porches Directions 1. Fill in the blanks. Please print legibly. 2. Indicate in the check box which detail from page 3 will be used. 5/18/10 (example: Tw6 1/2"x 4 1/2"fags @ 16" 0. C.) Electrical outlet required on decks over 20 sq. ft. 36" high guard with balusters spaced so that a 4 Inch diameter sphere cannot pass through Beam splices to occur over posts with 1 112" bearing 2x 8 joists spaced t s' " apart (example:2x 10° spaced 24° apart) (2) 2 x 8 beam (example: (2) 2 x 10 - see detail 8) Attach decking with non corrosive fasteners rim joist (example: 2 x 10 - see Alternate 81 & 132) ❑ Detail B ❑ Alternate Detail B1 0 Alternate Detail B2 (see page 3) _q_X posts spaced apart (example: 4 x 4posts spaced 8' apart) nditions such as attachment antilevers or veneers may uire Engineer's approval S'an Note: Emergency escape windows are alowed to be installed under decks and porches provided the location of the deck allows the emergency escape window to be fully opened and provides a path not less than 36" in height to a yard or court. 6'8" required for walk out basements or patios. Note: A plot plan (plan view) showing the dimensions of your project or additions and its relationships to existing buildings or structures on the property must be included. In addition to project dimensions, your plot plan must also show other details such as post locations and spacing, joist and beam spans, and any other pertinent information not shown on the section drawing. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2009 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 5/18/10 Single Family Residential Uncovered Decks and Porches Detail A Existing building Approved flashing required behind existing siding Attach to joists with non -corrosive fasteners Attach ledger to existing bldg. with non -corrosive lag bolts spaced min. 16" apart. Locate bolts to penetrate rim joist or wall studs. Non -corrosive metal joist hanger Approved flashing Conditions such as attachment to cantilevers or veneers may require Engineer's approval Alternate Detail B1 Beam splices to MAI occur over posts with 1 1/2" bearing Non -corrosive metal joist hanger 111 Alternate Detail l32 Secure balusters to beam Non -corrosive metal post/beam connector Secure balusters to beam Secure balusters to beam Beam splices to occur over posts with 1 1/2" bearing Non -corrosive metal post/beam connector Beam splices to occur over posts with 1 1/2" bearing Non -corrosive metal post/beam connector 1/2" (min.) diameter anchor bolt embedded 7" min. into concrete pier or the equivalent Finished rade 8" (min.) diameter pier Non -corrosive metal post anchor 8" min. If less than 8", post must be decay resistive This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2009 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements.