UNCOVERED DECK
POSTS AND PIERS LOCATION
03814 Remington St, Rifle CO 81650
.17's
,."X"
,
, ••
'
Rcrlitue vi4-7-1287/97-51D z-429, columns
1,0101- 4/ 4 TilareD 12003 044
0/44 -DARE og., giqr-re4--
Single Family Residential Uncovered Decks and Porches
Directions
1. Fill in the blanks. Please print legibly.
2. Indicate in the check box which detail from page 3
will be used.
5/18/10
(example: Tw6 1/2"x 4 1/2"fags @ 16" 0. C.)
Electrical outlet
required on decks
over 20 sq. ft.
36" high guard
with balusters
spaced so that a
4 Inch diameter
sphere cannot
pass through
Beam splices to occur over
posts with 1 112" bearing
2x 8 joists
spaced t s' " apart
(example:2x 10° spaced 24° apart)
(2) 2 x 8 beam
(example: (2) 2 x 10 - see detail 8)
Attach decking with non corrosive fasteners
rim joist
(example: 2 x 10 - see Alternate 81 & 132)
❑ Detail B
❑ Alternate Detail B1
0 Alternate Detail B2
(see page 3)
_q_X posts
spaced apart
(example: 4 x 4posts spaced 8' apart)
nditions such as attachment
antilevers or veneers may
uire Engineer's approval
S'an
Note: Emergency escape windows are alowed
to be installed under decks and porches provided
the location of the deck allows the emergency
escape window to be fully opened and provides a
path not less than 36" in height to a yard or court.
6'8" required for walk out basements or patios.
Note: A plot plan (plan view) showing the dimensions of your project or additions and its relationships to existing buildings or
structures on the property must be included. In addition to project dimensions, your plot plan must also show other details such as
post locations and spacing, joist and beam spans, and any other pertinent information not shown on the section drawing.
This handout was developed by the Colorado Chapter of the
International Code Council as a basic plan submittal under
the 2009 International Residential Code. It is not intended to
cover all circumstances. Check with your Department of
Building Safety for additional requirements.
5/18/10
Single Family Residential Uncovered Decks and Porches
Detail A
Existing building
Approved flashing required behind existing siding
Attach to joists with non -corrosive fasteners
Attach ledger to existing bldg.
with non -corrosive lag bolts
spaced min. 16" apart. Locate
bolts to penetrate rim joist or
wall studs.
Non -corrosive metal joist hanger
Approved flashing
Conditions such as attachment to cantilevers or
veneers may require Engineer's approval
Alternate Detail B1
Beam splices to
MAI
occur over posts
with 1 1/2" bearing
Non -corrosive
metal joist
hanger
111
Alternate Detail l32
Secure balusters
to beam
Non -corrosive
metal post/beam
connector
Secure balusters
to beam
Secure
balusters to
beam
Beam splices to
occur over posts
with 1 1/2" bearing
Non -corrosive metal
post/beam connector
Beam splices to
occur over posts
with 1 1/2" bearing
Non -corrosive metal
post/beam connector
1/2" (min.) diameter anchor bolt
embedded 7" min. into concrete pier
or the equivalent
Finished rade
8" (min.) diameter pier
Non -corrosive metal post anchor
8" min. If less than 8", post must be decay resistive
This handout was developed by the Colorado Chapter of the
International Code Council as a basic plan submittal under
the 2009 International Residential Code. It is not intended to
cover all circumstances. Check with your Department of
Building Safety for additional requirements.