Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5.0 Water Quality Data 2010
encana.. ural gas June 29, 2010 Garfield County Building & Planning Department 108 81h Street, Suite 201 Glenwood Springs, CO 81601 RE: Middle Fork Water Storage Pond Water Quality Data. Dear Sir or Madam: ) c o1/41, -) L '( 2717 County Road 215, Suite 100 Parachute, CO 81635 P: (970)285-2739 Please find the attached data summary table and laboratory analysis report for water samples collected from the Middle Fork Water Storage Pond on May 05, 2010. The data summary table also lists several reference standards for comparison with the analytical results. These standards are provided for relative comparison only, as the water is not intended to comply with any of the referenced regulatory standards. The water will be contained on site or used solely for natural gas exploration and production activities. As such, the water will not come in contact with the general public or with environmental receptors such as soil, ground water, or surface water. Please do not hesitate to contact our Parachute office should you have any questions or comments. Sincerely, Encaru - & G* s (U A) Inc. Brett Middleton EHS Field Coordinator Attachments Cc: David Grisso, Encana OiI & Gas (USA) Inc. Brenda Linster, Encana OiI & Gas (USA) Inc. File RECEJVEI) JUI.0?0111 GARFIELD COUNTY BUILDING & PLANNING Test Parameter Facility: Middle Fork Water Storage Pond Sample Date: May 5, 2010 Sample Identifier: MFPOND-050510 Sample Location: Storage Pond Laboratory Analytical Report Summary Analytical Regulatory Standards Units Result Level Reference Number Chloride mg/I 7,150 250 1,5 Fluoride mg/I 54.5 4.0 1 Bromide mg/I 0.10 none N/A Nitrate mg/l mg/I 0.12 0.12 10.0 1.0 1,2,3,4 1 Nitrile Sulfate mgll 5.0 250 1,5 Ammonia mg/1 3.0 none N/A pH su 6.92 6.5-8.5 1,3,5 Specific conductance pmhos/cm 24,500 none N/A Dissolved Solids mg/I 15,200 500 1,5 Arsenic mgll 0.0020 0.01 2 Barium mg/I 43.1 2.0 2,4 Cadmium mg/I 0.00030 0.005 2,4 Chromium mgt€ 0.0019 0.1 2,3 Copper mg/I 0.0059 1 4,5 Iron mg/I 6.02 5.0 3 Lead mg/I 0.0017 0.015 4 Magnesium mg/I 19.3 none N/A Manganese mg/I 0.621 0.05 5 Selenium mg/I 0.0032 0.05 2,4 Potassium mg/1 83.4 none NIA Silver mg)] 0.00080 0.05 2 Sodium mg/I 4,800 none N/A Benzene mg/I 4.96 0.005 3 Toluene mg/I 9.07 1 4 Ethylbenzene mg/I BDL 0.7 4 Total Xylene mg/I 5.29 10 4 Methane mg/I 1.18 none N/A Sulfide mg/I 0.15 none N/A Methyl tert-butyl ether (MTBE) mg/I BDL none N/A Alkalinity mg/I 588 none N/A Alkalinity, Bicarbonate mgt€ 587 none N/A Alkalinity, Carbonate mg/I 0.66 none N/A Notes: mg/1= milligrams per liter pg/1 = micrograms per liter pmhos/cm = micromhos per centimeter NTU = nephelometric turbidity units pH = parts of hydrogen su = standard unit BDL = below detection limit Standard Reference Numbers, Standard 1 = Colorado Department of Public Health and Environment Drinking Water Regulations Maximum Contaminant Level Standard 2 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards - Human Health Standarc Standard 3 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards - Agricultural Standard Standard 4 = U.S. Environmental Protection Agency National Primary Drinking Water Standard. Standard 5 = U.S. Environmental Protection Agency National Secondary Drinking Water Standards N/A = No applicable standard exists in referenced regulations. Test Parameter Facility: Middle Fork Water Storage Pond Sample Date: May 5, 2010 Sample Identifier: MW10-050510 Sample Location: Up Gradient Monitoring Well Laboratory Analytical Report Summary Analytical Regulatory Standards Units Result Level Reference Number Chloride mg/I 40.7 250 1,5 Fluoride mg/I 0.89 4.0 1 Bromide mg/I 6.8 none NIA Nitrate mg/I 3.0 10.0 1,2,3,4 Nitrite mg/I 1.7 1.0 1 Sulfate mg/I 136 250 1,5 Ammonia mg/I 0.050 none NIA pH su 7.00 6.5-8.5 1,3,5 Specific conductance pmhoslcm 991 none N/A Dissolved Solids mgll 673 500 1,5 Arsenic mg/I 0.0020 0.01 2 Barium mglI 0.106 2.0 2,4 Cadmium mg/I mg/I 0.00037 0.0019 0.005 0.1 2,4 2,3 Chromium Copper mgll 0.0101 1 4,5 Iron mg/I 0.013 5.0 3 Lead mg/I 0.0017 0.015 4 Magnesium mg/I 52.9 none NIA Manganese _ mg/I 0.0076 0.05 5 Selenium mgh 0.0032 0.05 2,4 Potassium mg/I 2.84 none N/A Silver mg/I 0.00080 0.05 2 Sodium mg/I 63.2 none N/A Benzene mg/I BDL 0.005 3 Toluene mg/I BDL 1 4 Ethylbenzene mg/I BDL 0.7 4 Total Xylene mg/I BDL 10 4 Methane mg/I BDL none N/A Sulfide mgli 0.15 none NIA Methyl tert-butyl ether (MTBE) m911 BDL none N/A Alkarinity mg/I NT none N/A Alkalinity, Bicarbonate mg1I 349 none N/A Alkalinity, Carbonate mgll 1.2 none NIA Notes: mg/l » milligrams per liter pgll = micrograms per liter pmhoslcm » micromhos per centimeter NTU = nephelometric turbidity unit: pH = parts of hydrogen su = standard unit BOL = below detection limit Standard Reference Numbers, Standard 1 = Colorado Department of Public Health and Environment Drinking Water Regulations Maximum Contaminant Level Standard 2 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards - Human Health Standarc Standard 3 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards -Agricultural Standard Standard 4 = U.S. Environmental Protection Agency Nationat Primary Drinking Water Standard: Standard 5 = U.S. Environmental Protection Agency National Secondary Drinking Water Standards N/A » No applicable standard exists in referenced regulations. Test Parameter Facility: Middle Fork Water Storage Pond Sample Date: May 5, 2010 Sample Identifier: MW11-050510 Sample Location: Down Gradient Monitoring Well Laboratory Analytical Report Summary Analytical Regulatory Standards Units Result Level Reference Number Chloride mg/I 66.8 250 1,5 Fluoride mg/I 0.67 4.0 1 Bromide mg/I 0.10 none N/A Nitrate mg/1 0.78 10.0 1,2,3,4 Nitrite mg/1 0.32 1.0 1 Sulfate mg/I 83.8 250 1,5 Ammonia mgli 0.060 none N/A pH su 7.17 6.5-8.5 1,3,5 Specific conductance iimhos/cm 835 none NIA Dissolved Solids mg/l 494 500 1,5 Arsenic mg/I 0.0020 0.01 2 Barium mg/I 0.104 2.0 2,4 Cadmium mg/l 0.00030 0.005 2,4 Chromium mg/I 0.0019 0.1 2,3 Copper mg/I 0.0059 1 4,5 Iron mgll 0.013 5.0 3 Lead mg/I 0.0017 0.015 4 Magnesium mg/I 40.7 none N/A Manganese mg/I 0.0076 0.05 5 Selenium mg/I 0.0032 0.05 2,4 Potassium mg/I 2.14 none N/A Silver mg/I 0.00080 0.05 2 Sodium mg/I 49.6 none NIA Benzene mg/I BDL 0.005 3 Toluene mg/I BDL 1 4 Ethylbenzene mg/1 BDL 0.7 4 Total Xylene mg/1 BDL 10 4 Methane mg/I BDL none N/A Sulfide mg/1 0.15 none N/A Methyl tert-butyl ether (MTBE) , mg/l BDL none NIA Alkalinity mg/I NT none N/A Alkalinity, Bicarbonate mg/I 314 none N/A Alkalinity, Carbonate mg/I 1.9 none N/A Notes: mg/I = milligrams per liter }igil • micrograms per liter pmhos/cm = micromhos per centimeter NTU = nephelometric turbidity unit; pH = parts of hydrogen su = standard unit BDL = below detection limit Standard Reference Numbers: Standard 1 = Colorado Department of Public Health and Environment Drinking Water Regulations Maximum Contaminant Level Standard 2 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards - Human Health Standarc Standard 3 = Colorado Department of Public Health and Environment Water Quality Control Commission Ground Water Standards - Agricultural Standarc Standard 4 = U.S. Environmental Protection Agency National Primary Drinking Water Standard, Standard 5 = U.S. Environmental Protection Agency National Secondary Drinking Water Standards N/A = No applicable standard exists in referenced regulations. in Gulf Coast ACCUTEST e -Hardcopy 2.0 Automated Report FT'S ALL IN THE CHEMISTRY Technical Report for ENCANA GARCO Middle Fork Pond Sampling Accutest Job Number: T52142 Sampling Date: 05/05/10 Report to: EnCana 2717 Co, Rd. 215 Parachute, CO 81635 brett.middleton@encana.com; christopher.hines@eucana.com ATTN: Brett Middleton Total number of pages in report: 39 to ACco oit , e .:, Test results contained within this data package meet the requirements of the National Environmental Laboratory Accreditation Conference and/or state specific certification programs as applicable. Client Service contact: Sylvia Garza 713-271-4700 05/20/10 Paul Canevaro Laboratory Director Certifications: TX (r104704220.09C-TX) AR (88-0756) FL (E87628) KS (E-10366) LA (85695!04004) OK (9103) UT(7132714700) This report shall not be reproduced, except in hs entirety, without the written approval of Accutest Laboratories. Test results relate only to samples analyzed. Gulf Coast • 10165 Harwin Drive • Suite 150 • Houston, TX 77036 • lel: 713-271-4700 • fax: 713-271-4770 • http://www.accutest.com ® 1 of 39 AfCCUTEST, T52142 Accutest Laboratories is the sole authority for authorizing edits or modifications to Ibis document, Unauthorized modification of this report is strictly prohibited. Sections: Table of Contents -1- Section 1: Sample Summary 3 Section 2: Case Narrative/Conformance Summary 4 Section 3: Sample Results 8 3.1: T52142-1: MFPOND-050510 9 3.2: T52142 -1F: MFPOND-050510 (DISS©LVED) 12 Section 4: Misc. Forms 13 4.1: Chain of Custody 14 Section 5: CC/MS Volatiles - QC Data Summaries 17 5.1: Method Blank Summary 18 5.2: Blank Spike Summary 19 5.3: Matrix Spike/Matrix Spike Duplicate Summary 20 Section 6: Riet els Analysis - QC I)aita Summaries 21 6.1: Prep QC MPI 1742: As,Ba,Cd,Ca,Cr,Cu,Fe,Pb,Mg,Mn,K,Se,Ag,Na 22 Section 7: General Chemistry - QC Data Summaries 27 7.1: Method Blank and Spike Results Summary 28 7.2: Blank Spike Duplicate Results Summary 29 7.3: Duplicate Results Summary 30 7.4: Matrix Spike Results Summary 31 Section 8: Misc. Forms (Accutest Laboratories Southeast, Inc.) 32 8.1: Chain of Custody 33 Section 9: GC Volatiles - QC Data (Accutest Laboratories Southeast, Inc.) 35 9.1: Method Blank Summary 36 9.2: Blank Spike Summary 37 9.3: Matrix Spike Summary 38 9.4: Duplicate Summary 39 D 00 /MIN 2 of 39 ACCUTEST. 152142 D Accutest Laboratories Sample Summary ENCANA GARCO Middle Fork Pond Sampling Job No: T52142 Sample Collected Matrix Client Number Date Time By Received Code Type Sample ID 152142-1 05/05/10 14:15 AS 05/06/10 AQ Water MFPOND-050510 T52142 -IF 05/05/10 14:15 AS 05106/10 AQ Water Filtered MFPOND-050510 (DISSOLVED) em® 3of39 AST T52142 C ACCU TEST. Laboratories SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ENCANA site: GARCO Middle Fork Pond Sampling Job No T52I42 Report Date 5/19/2010 3:53:29 PM 2 Sample(s), were collected on 05/05/2010 and were received at Accutest on 05/06/2010 properly preserved, at 2.2 Deg. C and intact. These Samples received an Accutest job number of T52142. A listing of the Laboratory Sampk ID, Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below, all method specified calibrations and quality control performance criteria were met for this job. For more information, please refer to QC summary pages. Volatiles by GCMS By Method SW846 8260B Matrix AQ Batch ID: VX536 ■ All samples were analyzed within the recommended method holding time. ■ All method blanks for this batch meet method specific criteria. • Sample(s) T51846-1MS, T51846-1MSD were used as the QC samples indicated. Volatiles by GC By Method RSKSOP-147/175 Matrix AQ Batch ID: F:GXY1823 ■ T52142 Analysis performed at Accutest Laboratories, Orlando, FL. Metals By Method SW846 6010B Matrix AQ Batch ID: MP 11742 All samples were digested within the recommended method holding time. ■ All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. ■ Sample(s) T52066-IFDUP, T52066 -/FMS, T52066-1FMSD, T52066-1FSDL were used as the QC samples for metals. ■ RPD(s) for Serial Dilution for Copper, Manganese, Potassium are outside control limits for sample MPI 1742 -SDI. Percent difference acceptable due to low initial sample concentration (< 50 times IDL). Wet Chemistry By Method EPA 120.1 Matrix AQ Batch ID: GN22830 to All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. • Sample(s) T51989-1DUP were used as the QC samples for Specific Conductivity. Wednesday, May 19, 2010 Page 1 of3 e® 4 of 39 CaAcCUTEST. T52142 Wet Chemistry By Method EPA 3O0/SW846 9056 Matrix AQ Batch ID: GP8860 • All samples were distilled within the recommended method holding time. • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. - Sarnple(s) T52155-2DUP, T52I55-2MS were used as the QC samples for Chloride. Matrix AQ Batch ID: GP8893 • All samples were distilled within the recommended method holding titne. • All samples were analyzed within the recommended method holding time. • All method blanks for (his batch meet method specific criteria. • Sample(s) T52142-IDUP, T52142-1MS were used as the QC samples for Nitrogen, Nitrate, Nitrogen, Nitrite, Nitrogen, Nitrate. • Matrix Spike Recovery(s) for Nitrogen, Nitrite are outside control limits. Probable cause due to matrix interference, Matrix AQ Batch ID: 0P8894 - Ali samples were distilled within the recommended method holding time. • All samples were analyzed within the recommended method holding tune. • All method blanks for this batch meet method specific criteria. • Sample(s) T52063-IDUP, T52063 -IMS were used as the QC samples for Bromide, Fluoride, Sulfate, Bromide. - Matrix Spike Recovery(s) for Bromide, Fluoride, Sulfate are outside control limits. Probable cause due to matrix interference. Wet Chemistry By Method SM 21 4500 NH3D Matrix AQ Batch ID: GP8826 • All samples were distilled within the recommended method holding titne. • All samples were analyzed within the recommended method holding lime. - All method blanks for this batch meet method specific criteria. - Sample(s) T52211-1DUP, T5221 I -IMS were used as the QC samples for Nitrogen, Ammonia. • RPD(s) for Duplicate for Nitrogen, Ammonia are outside control limits for sample GP8826-D1. Wet Chemistry By Method SM 2320B Matrix AQ Batch ID: GN22772 • Sample(s) T52269-IDUP, T52269 -IMS were used as the QC samples for Alkalinity, Total as CaCO3. Wet Chemistry By Method SM 2540C Matrix AQ Batch ID: GN22645 • All samples were analyzed within the recommended method holding bine, • All method blanks for this batch meet method specific criteria. - Sample(s) T51976-1DUP were used as the QC samples for Solids, Total Dissolved. Wet Chemistry By Method SM 4500 CO2 D Matrix AQ Batch ID: GN22740 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. - Sample(s) T51898-1DUP were used as the QC samples for Alkalinity, Bicarbonate. Wednesday, May 19, 2010 Page 2 of 12IN 5 of 39 AAGUTEST. T52142 Wet Chemistry By Method SM 4500H+B/9040 Matrix AQ Batch ID: GN22626 • Sample(s) T52155-1DUP were used as the QC samples for p11 Wet Chemistry By Method SM 45005+F Matrix AQ Batch ID: GN22666 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. Wet Chemistry By Method SM 18 2320B Matrix AQ Batch ID: GN22741 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. • Sample(s) T52269-IDUP were used as the QC samples for Alkalinity, Carbonate. Accutest Laboratories Gulf Coast (ALGC) certifies that this report meets the project requirements for analytical data produced for the samples as received al ALGC and as stated on the COC. ALGC certifies that the data meets the Data QualityObjeclives for precision, accuracy and completeness as specified in the ALGC Quality Manual except as noted above. This report is to be used in its entirety. ALGC is not responsible for any assumptions of data quality if partial data packages are used Wednesday, May 19, 2010 Page 3 of 3 mi 6of39 ®ACCUTESt T52142 SAMPLE DELIVERY GROUP CASE NARRATIVE Client: Accutest Laboratories Gulf Coast, Inc. Job No: T52142 Site: ENCACOP: GARCO Middle Fork Pond Sampling Report Date 5/12/2010 9:17:42 AM 1 Sample was collected on 05/05/2010 and was received at Accutest, SE on 05/07/2010 properly preserved, at 2.2 Deg. C and intact. This Sample received an Accutest job number of T52142. A listing of the Laboratory Sample ID, Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below, all method specified calibrations and quality control perfonnance criteria were met for this job. For more information, please refer to QC summary pages. Volatiles by GC By Method RSKSOP-147/175 Matrix: AQ Batch ID: GXYI823 All samples were analyzed within the recommended method holding time. All method blanks for (his batch meet method specific criteria. Sample(s) T52143-1DUP, T52143 -IMS were used as the QC samples indicated. Accutest Laboratories Southeast (ALSE) certifies that this report meets the project requirements for analytical data produced for the samples as received at ALSE and as stated on the COC. ALSE certifies that the data meets the Data Quality Objectives for precision, accuracy and completeness as specified in the ALSE Quality Manual except as noted above. This report is to be used in its entirety. ALSE is not responsible for any assumptions of data quality if partial data packages are used Narrative prepared by: Lovelie Metzgar, QA Assistant (signature on file) Date: May 12, 2010 Wednesday, May 12, 2010 Page 1 of 1 Ea® 7 of 39 ACCUTEST T52142 min Gulf Coast ACCUrEST. IT'S ALL. IN THE CHE14I5TR Y Sample Results Report of Analysis Section 3 WI 8 of 39 ACCUTEST. T52142 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Method: Project: MFPOND-050510 T52142-1 AQ - Water SW846 8260E GARCO Middle Fork Pond Sampling Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #1 Run #2 File ID X0061069.D DF Analyzed By 500 05/08/10 JL Prep Date n/a Prep Batch Analytical Batch n/a VX536 Run 111 Run 112 Purge Volume 5.0 ml Purgcable Aromatics, MTBE CAS No. Compound 71-43-2 108-88-3 100-41-4 1330-20-7 1634-04-4 Benzene Toluene Ethylbenzene Xylene (total) Methyl Tert Butyl Ether CAS No. Surrogate Recoveries 1868-53-7 Dibromofluoromethane 17060-07-0 1,2-Dichloroethane-D4 2037-26-5 Toluene -D8 460-00-4 4- Bromofluorobenzene Result RL MDL units Q 4.96 1.0 0.25 nig/1 9.07 1.0 0.22 mg/I ND 1.0 0.27 nig/I 5.29 3.0 0.84 mg/I ND 1.0 0.36 mg/1 Run# 1 Run# 2 Limits 90% 79-122% 87% 75-121% 91% 87-119% 92% 80-133% ND = Not detected MDL - Method Detection Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value B = Indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound w r CCI TEST. T52142 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Method: Project: MFPOND-050510 T52142-1 AQ - Water RSKSOP-1471 175 GARCO Middle Fork Pond Sampling Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #i a Run #2 File ID XY043936. D DF 2 Analyzed By Prep Date 05/11/10 AFL n/a Prep Batch Analytical Batch n/a F:GXY1823 CAS No. Compound 74-82-8 Methane Result RL MDL Units Q 1.18 0.0010 0.00032 mg/I (a) Analysis performed at Accutest Laboratories, Orlando, FL. ND = Not detected MDL - Method Detection Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value B = Indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound ®® 10 of 39 ACCUTEST. T52142 ' Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: MFPOND-050510 Lab Sample ID: T52142-1 Matrix: AQ Water Project: GARCO Middle Fork Pond Sampling Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a General Chemistry Analyte Alkalinity, Bicarbonate Alkalinity, Carbonate Alkalinity, Total as CaCO3 Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Solids, Total Dissolved Specific Conductivity Sulfate Sulfide pH Result RL MDL Units DF Analyzed 587 5.0 0.66 mg/1 1 05/13/10 MC 0.66 U 5.0 0.66 mg/I 1 05/17/10 MC 588 5.0 1.7 ing/ I 1 05/17/10 MC 0.10U 0.50 0.10 mg/I 1 05/16/10 01:06 13F 7150 500 190 mg/1 1000 05/13/1018:51 BF 54.5 2.5 1.3 Ing/1 5 05/16/10 00:48 BF 3.0 0.10 0.0060 mg/I 1 05/12/10 15:35 BF 0.12 U 0.50 0.12 mg/1 1 05/06/10 21:20 BF 0.12 U 0.50 0.12 mg/1 1 05/06/10 21:20 BF 15200 200 51 mg/I 1 05/07/10 BG 24500 1.0 umhos/cm 1 05/17/1009:30 MC 5.0 0.50 0.151118/1 1 05/16/10 01:06 BF 0.15 U 0.20 0.15 me 1 05/10/10 10:00 KD 6.92 sU 1 05/06/10 17:00 CN Method SM 4500 CO213 SM 18 232013 SM 2320B EPA 300/SW846 9056 EPA 300/SW846 9056 EPA 300/SW846 9056 SM 21 4500 NH3D EPA 300/SW846 9056 EPA 300/SW846 9056 SM 2540C EPA 120.1 EPA 300/SW846 9056 SM 4500S+ F SM 4500H+ 13/9040 RL = Reporting Limit MDL = Method Detection Limit U = Indicates a result < MDL 13= Indicates a result > = MDL but < RL �® 11 of 39 ACCUTEST. T52142 ' Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: MFPOND-050510 (DISSOLVED) Lab Sample ID: T52142 -1F Date Sampled: 05/05/10 Matrix: AQ - Water Filtered Date Received: 05/06/10 Percent Solids: n/a Project: GARCO Middle Fork Pond Sampling Dissolved Metals Analysis Analyte Result RL MDL Units DF Prep Analyzed By Method Prep Method Arsenic 0.0020 U 0.0050 0.0020 mg/1 1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 4 Barium 43.1 1.0 0.014 mg/1 5 05/09/10 05/12/10 NS SW846 6010B 2 SW846 3010A 4 Cadmium 0.00030 U 0.0040 0.00030 mg/1 1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 4 Calcium 310 5.0 0.035 mg/1 1 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 4 Chromium 0.0019 U 0.010 0.0019 mg/1 1 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 4 Copper 0.0059 U 0.025 0.0059 mg/I 1 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 4 Iron 6.02 0.10 0.013 mg/1 1 05/09/10 05/11/10 NS SW846 6010131 SW846 3010A 4 Lead 0.0017 U 0.0030 0.0017 mg/1 1 05/09/10 05/11/10 NS SW846 601 013 1 SW846 3010A 4 Magnesium 19.3 5.0 0.0078 mg/I 1 05/09/10 05/11/10 NS SW846 6010131 SW846 3010A 4 Manganese0.621 0.015 0.O076 mg/1 1 05/09/10 05111/10 NS SW846 601013 1 SW846 3010A 4 Potassium 83.4 25 0.27 mg/I 5 05/09/10 05/12/10 NS SW846 6010B 2 SW846 3010A 4 Selenium 0.0032 U 0.0050 0.0032mg/I 1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 4 Silver 0.00080 U 0.010 0.00080 mg/1 1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 4 Sodium 4800 250 6.7 mg/1 50 05/09/10 05/16/10 NS SW846601013 3 SW8463010A4 (1) Instrument QC Batch: MA4732 (2) Instrument QC Batch: MA4734 (3) Instrument QC Batch: MA4747 (4) Prep QC Batch: MPI 1742 RL = Reporting Limit U = Indicates a result < MDL MDL = Method Detection Limit B = Indicates a result > = MDL but < RL N el® 12 of 39 AC CL ESt T52142 ' Gulf Coast ACCUTE9t 1 T' S ALL 1N IHE L H 1 11 I S I I7 Y Misc. Forms Custody Documents and Other Forms Includes the following where applicable: Chain of Custody Section 4 ®® 13 of 39 ACCUTE5T. T52142 El CHAIN OF CUSTODY PAGE / OF / r' .rak11.1.Slmribm. , C 1. 1 10165 Irarwle. Dr,Sic 1701hua. TX 71016 FEOEa Twt%a, &we aor tammla Laboratories ,EL.71Mi714700 FAX: /M2714110 dMwd.l :.tc.rom aaaleslada! Access; .11 2. "r 5-2. `, 1 _] 2 Cllenl l Roporllnp lnfoFinaUOn' t X,y+ `' (' -_"S'. proj.cI Information E g` ;h AM Rogues e d Analyses Mstds Codes OW m - °dekko Wilier Walar tow -Wal. Sw. &plusWalar SL -eludes BE DI NSH.011 enl UO-O,:e.Lpvb loft - k SOL -Other Sold WP. WlAe FHFhN blank HIE Rrn:rtl ansck AE atm swnx Ya -MP Wank Company Name nn n .OLJUI. V t 11 &t -S (USA) i SIC . Pleled Noma: fJ� �` -�7 �1 ref] ft Grtp f t dcLlt ii{T L (-ii ,.d al .(J1- .. l I I)BYI Seed Add,. i1-7 &bat SV.4.11✓I400 Serol ADP-ni F=' -::v: kai'.>.P r7'�: P.c A±h 111.0Mfwmad.IMd..bamRap . ^rLealar Blah�y_ /� Zip +.�t+IW:iL- Co, t%r.N co, Bbl. Cemwny Noma Pmjed Ca,Ind1 E -mel -Bre'4}ril' n brettAtiCItt(LFosEeefi Prlod17 warcorr SeAaamaa ed PrM]rn't ��`r (y Fl.a -14`=•;1.85. a`t I Tdkd PaUayse Ob. Y Cay St. kP Swnple(el Nam.f.) Mond F 4/14i2ZYk'1 aSTC-1 Pmad A.m.. Anon{bly ..n*• Flaw /Point of Collection Cdk nen..bp. nwl lbw b b.ED T. e0w0000 aa.a E...a k i € 8 ! E t i l LAB USE ONLY rwi r 4- osos1 o oa/io r'r5 AS NU) /r 1 9 $iS!+ Twnemund Tinml Bwhara bays) t'S.77' '. 8-' •'''=`,'TF -;•0,4%. L s'frj Deis Deliverable Infomllllon .. "';-:.1~- -Sia-, __f,..'! Ceements Spotlit [mfiaclions r, _. -,V, ISI4andrd II1..v..01.010.14J:10ale: En a Day -RUST/ li Cammarclal"A'lt.aell Q TRAP Q Cummnckl'B• 13 .171 13240 Format o •Day RUSH 171 FULTl IL.n el3.al LI 011ie El aDeyRUSH 171 RSDTI ILaval 7 4I o Ypay ROTH Q Comm.rcrl"C" El i Day EMERGENCY • Ccmm.Ms A = lk.dk Only Enarpnncy X WW1 T/A d awlaba WA Latvia COnonar3al'En =Mauna • OC Summary Fcm.wdal V" =Mauls a OC t Sanoaale Ravnmry - = TRITIPFi's?':. -�,b1r: Smote Custody melba documaHtsd 5 low each leve aacphs champs possession, Including cowl. darn,. f :"` '.-IOM4 L,' 3 - r1 's I _ Rada hwar Unpin-. Malan: ore• 1730 AauInd My: 1 a.l.drhh.a Bye 2 D... Thaw BaaM4 Pal 2 Nlkntl earl 3 a n.e RaMraa ear: 3 eNi,q,iiah.tl OT: 4 Frci Sf 04111,1T0 SAPBrwN.tl 6y: 4 P 4Maq: 5 Od.Tae. aaaan tJl1 5 _ Gnadylkoa n read Prom/veal whops aSNlulk.. On leo Cea.rlr.! 11 Haddad o V 2.2 T52142: Chain of Custody Page 1 of 3 El® 14 of 39 ACCUTESTa T52142 SAMPLE INSPECTION FORM Accutest Job Number: T5-21 ti 2 Client: [.vif i& a/ i (i•i s # of Coolers Received: / Thermometer #: ii./ Temperature Adjustment Factor: - a • s Cooler Temps: #1: 1.2 #2: #3: #4: #5: #6: #7: #8: Method of Delivery: Da UPS Accutest Courier Greyhound Delivery Other Airbili Numbers: Date/Time Received: Ti/Via al ;a COOLER INFORMATION Custody seal missing or not intact Temperature criteria not mel Wet Ice received in cooler CRAIN OF CVSTOIZY Chain of Custody not received Sample D/T unclear or missing Analyses unclear or missing COC not properly executed Summary of Discrepancies: r SAMPLE INFORMATION Sample containers received broken VOC vials have headspace Sample labels missing or illegible ID on COC does not match labciisl D/T on COC does not match label(sl Sample/Bottles revd but no analysis on COC Sample listed on COC, but not received Bottles missing for requested analysis Insufficient volume for analysts Sample received improperly preserved TRIP B,LANIC INFORMATION Trip Blank on COC but not received 'hip Blank received but not an COC Trip Blank not Intact Received Water Trip Blank Received Soil 1B Number of Encores? Number of 5035 klts? Number of lab-Ntered metals? TECHNICIAN SIGNATURE/DATE: INFORMATION AND SAMPLE LABELING VERIFIED BY: • . . . • • • 4 Client Representative Notified: By Accutest Representative: Client Instructions: J • 2/f CORRECTIVE ACTIONS • Date: Via: 4 4 4 • . • ♦ 4 Phone Email t.M..a.ettanAun•4mmygrniK T52142: Chain of Custody Page 2 of 3 15 of 39 ®ACCUTEST: T52142 JOB #: CLIENT: -rsz yy2 SAMPLE RECEIPT LOG DATE/TIME RECEIVED: INITIALS: 6rlLffhit al ¢ r1G. COOLER SAMPLE ID FIELD ID DATE MATRIX VOL BOTTLE LOCATION PRESERV PH I Mt -GCOCO W PL+ I- 3 a+ Q/ 2 3 4 5 5 7 8 <2 >12 PsDP 3 '• p 2 3 4 5 e 7 8 <2 >12 p7rb y_ "1 1 2 3 4 g, 8 7 car ' r� 1 2 3 Cb 5 8 7 8.. -SF >12 .Jr W m/ b- !f 1!L b5 8 79 8 4 <2 >12 1 2 3 4 >12 >12 Q >12 <2 >12 1 <2 >19 <2 >12 ■� <2 >12 <2 >12 111 <2 >12 >12 lt12 >12 >12 >12 M __ IMIIMMINI 16 d 7 8 4 <2 >12 <2 >12 PRESERVATIVES: 1: None 2: HCL 3: HNO3 4: H2SO4 5: NAOH 6: 01 7: McOH 8: Other LOCATION: 1:. Walk -In #1 (Waters) 2; Walk -In 1/2 (Sols) VR: Volatile Fridge M: Metals SUB: Subcontract EF: Encore Freezer T52142: Chain of Custody Page 3 of 3 ®5 16 of 39 ACCUTEST: T52142 Gulf Coast ACCUTEST LT'S ALL LN THE CHEMISTRY GC/MS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spikc Summaries • Matrix Spikc and Duplicate Summaries Section 5 ori 17 of 39 ACCUTEST. T52142 Method Blank Summary Job Number: T52142 Account: ENCACOP ENCANA Project: GARCO Middle Fork Pond Sampling Page 1 of 1 Sample File ID DF Analyzed By Prep Dale Prep Balch Analytical Batch VX536-MB X0061055.D 1 05/08/10 JL n/a n/a VX536 The QC reported here applies to the following samples: T52142-1 CAS No. Compound Method: SW846 8260B Result RL MDL Units Q 71-43-2 Benzene ND 2.0 0.50 ug/1 100-41-4 Ethylbenzenc ND 2.0 0.55 ug/1 1634-04-4 Methyl Tert Butyl Ether ND 2.0 0.73 ug/1 108-88-3 Toluene ND 2.0 0.43 ug/1 1330-20-7 Xylene (total) ND 6.0 1.7 ug/I CAS No. Surrogate Recoveries Limits 1868-53-7 Dibromofluoromethane 90% 79-122% 17060-07-0 1, 2-Dichloroethanc-D4 90% 75-121% 2037-26-5 Toluene -D8 92% 87-119% 460-00-4 4-Bromofluorobenzene 90% 80-133% 1 -. Elan 18 of 39 ACCUTESt T52442 Blank Spike Summary Job Number: T52142 ENCACOP ENCANA GARCO Middle Fork Pond Sampling Account: Project: Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep (latch Analytical Batch VX536-BS X0061053.D 1 05/08/10 JL n/a Gila VX536 The QC reported here applies to the following samples: T52142-1 CAS No. Compound Spike BSP BSP ug/l ug/1 % Limits 71-43-2 Benzene 25 22.6 90 76-118 100-41-4 Ethyibenzene 25 24.2 97 75-112 1634-04-4 Methyl Tert Butyl Ether 25 20.2 81 65-113 108-88-3 Toluene 25 23.7 95 77-114 1330-20-7 Xylene (total) 75 72.4 97 75-111 CAS No. Surrogate Recoveries BSP Limits 1868-53-7 Dibromofluoromethane 90% 79-122% 17060-07-0 1,2-Dichloroethane-D4 90% 75-121% 2037-26-5 Toluene -D8 94% 87-119% 460-00-4 4-Bromofluorobenzene 91% 80-133% Method: SW846 8260B un N EM® 19 of 39 AST. T52142 Matrix Spike/Matrix Spike Duplicate Summary Job Number: T52142 Account: ENCACOP ENCANA Project: GARCO Middle Fork Pond Sampling Page 1 of 1 Sample T51846 -IMS T5I 846-1 MSD T5 1846- I File ID DF X0061061.D 1 X0061062.D 1 X0061060.D l Analyzed By 05/08/10 JL 05/08/10 JL 05/08/10 JL Prep Date Prep Batch n/a n/a n/a n/a n/a n/a Analytical Batch VX536 VX536 VX536 The QC reported here applies to the following samples: T52142-1 CAS No. Compound 71-43-2 100-41-4 1634-04-4 108-88-3 1330-20-7 Benzene Ethylbenzene Methyl Tert Butyl Ether Toluene Xylene (total) CAS No. Surrogate Recoveries 1868-53-7 Dibroinofluoromethane 17060-07-0 1,2-Dichloroethane-D4 2037-26-5 Toluene -D8 460-00-4 4-Bromofluorobenzene T51846-1 Spike MS MS ug/1 Q ug/I ugfl % ND ND ND ND ND MS 90% 90% 94% 92% 25 23.7 95 25 25.2 101 25 21.1 84 25 24.9 100 75 75.5 101 Method: SW846 8260B MSD MSD Limits ug/1 % RPD Rec/RPD 22.8 91 4 76-118/16 24.6 98 2 75-112/12 21.7 87 3 65-113/13 24.4 98 2 77-114/12 74.2 99 2 75-111/12. MSD T51846-1 Limits 90% 90% 93% 89% 91% 88% 91% 90% 79-122% 75-121% 87-119% 80-133% ®® 20 of 39 ACCtJTEST. T52142 In Gulf Coast ,ACC TEST Lab IT'S ALL IN THE CHEMISTRY Metals Analysis QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Matrix Spike and Duplicate Summaries • Blank Spike and Lab Control Sample Summaries • Serial Dilution Summaries Section 6 EM® 21 of 39 ACCUTEST. 752142 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: BLANK RESULTS SUMMARY Part 2 - Method Blanks Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling 05/09/10 Methods: SW846 6010B Units: ug/1 Met e1 MB RL IDL MDL raw final Aluminum 200 16 17 Antimony 5.0 2.3 3 Arsenic 5.0 1.8 2 -1.1 <5.0 Barium 200 .14 2.7 0,0 <200 Beryllium 5.0 .11 .2 Boron 100 1.1 2.1 Cadmium 4.0 .25 .3 -0,040 <4.0 Calcium 5000 5.4 35 5.3 <5000 Chromium 10 1.1 1.9 -1.3 <10 Cobalt 50 .5 .8 Copper 25 .58 5.9 1.0 <25 Iron 100 13 13 -14 <100 Lead 3.0 1.6 1.7 -0.29 <3.0 Magnesium 5000 6.7 7.8 -2.3 <5000 Manganese 15 .2 7.6 0.40 <15 Molybdenum 10 .96 1.3 Nickel 40 .95 3.2 Potassium 5000 53 53 -52 <5000 Selenium 5.0 3.2 3.2 2.7 <5.0 Silver 10 .85 .8 0.020 <10 Sodium 5000 130 130 -110 <5000 Strontium 20 .17 .4 Thallium 10 3.2 2.6 Tin 20 1.6 2.9 Titanium 20 .3 .3 Vanadium 50 .6 .6 Zinc 20 .49 4.1 Associated samples M811742: T52142 -1F Results < IDL are shown as zero for calculation purposes (*) Outside of QC limits (anr) Analyte not requested Page 1 0) rk'1 22of39 AccLTrEST. T 52142 QC Hatch ID: MP11742 Matrix Type: AQUEOUS Prep Date: MATRIX SPIKE AND DUPLICATE RESULTS SUMMARY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling 05/09/10 Methods: 547846 6010B Units: ug/1 05/09/10 Metal T52066 -1F QC T52066 -1F Spikelot QC Original DUP RPD Limits Original MS MPTW4 % Rec Limits Aluminum Antimony Arsenic 0.0 0.0 NC 0-20 0.0 402 400 100.5 80-120 Barium 79.1 77.1 2.6 0-20 79.1 519 40D 110.0 80-120 Beryllium Boron Cadmium 0.0 0.0 NC 0-20 0.0 400 400 100.0 80-120 Calcium 67700 65900 2.7 0-20 6770D 121000 50000 106.6 80-120 Chromium 0.0 0.0 NC 0-20 0.0 417 400 104.3 80-120 Cobalt Copper 10 9.2 8.3 0-20 10 435 400 106.3 80-120 Iron 0.00 0.0 NC 0-20 0.00 52100 50000 104.2 80-120 Lead 0.0 0.0 NC 0-20 0.0 405 400 101.3 80-120 Magnesium 13000 12700 2.3 0-20 13000 65600 50000 105.2 80-120 Manganese 0.81 0.83 2.4 0-20 0.81 420 400 104.8 80-120 Molybdenum Nickel Potassium 2110 2060 2.4 0-20 2110 53800 50000 103.4 80-120 Selenium 0.0 0.0 NC 0-20 0.0 412 400 103.0 80-120 Silver 0.0 0.0 NC 0-20 0.0 420 400 105.0 80-120 Sodium 71100 75300 2.4 0-20 77100 131000 50000 107.8 80-120 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52142 -1F Results < IDL are shown as zero for calculation purposes 1•) Outside of QC limits (N) Matrix Spike Rec. outside of QC limits Cant -1 Analyte not requested Page 1 573 ®® 23 of 39 QACCLJTEST. T52142 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: MATRIX SPIKE AND DUPLICATE RESULTS SUMMARY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling 05/09/10 Methods: SW846 6010B Units: ug/1 Metal T52066 -1F Spikelot MSD QC Original MSD MPTW4 4 Rec RPD Limit Aluminum Antimony Arsenic 0.0 403 400 100.8 0.2 20 Barium 79.1 528 400 112.2. 1.7 20 Beryllium Boron Cadmium 0,0 403 400 100.8 0.7 20 Calcium 67700 124000 50000 112.6 2.4 20 Chromium 0.0 423 400 105.8 1.4 20 Cobalt Copper 10 443 400 108.3 1.8 20 Iron 0.00 52800 50000 105.6 1.3 20 Lead 0,0 409 400 102.3 1.0 20 Magnesium 13000 67000 50000 108.0 2.1 20 Manganese 0.91 426 400 106.3 1,4 20 Molybdenum Nickel Potassium 2110 54100 50000 104.0 0.6 20 Selenium 0.0 420 400 105.0 1.9 20 Silver 0.0 425 400 106.3 1.2 20 Sodium 77100 134000 50000 113.8 2.3 20 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples 14P11742: T52142 -1F Results < IDL are shown as zero for calculation purposes (') Outside of QC limits (N) Matrix Spike Rec. outside of QC limits (anr) Analyte not requested Page 2 CO 24 of 39 ©ACCLJTEST. 757142 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: SPIKE BLANK AND LAB CONTROL SAMPLE SUMMARY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling 05/09/10 Methods: SW846 60108 Units: ug/1 Metal BSP Spikelot QC Result MPTW4 % Rec Limits Aluminum Antimony Arsenic 412 400 103.0 80-120 Barium 456 400 114.0 80-120 Beryllium Boron Cadmium 420 400 105.0 80-120 Calcium 53900 50000 107.8 80-120 Chromium 434 400 108.5 80-120 Cobalt Copper 440 400 110.0 80-120 Iron 54300 50000 108.6 80-120 Lead 425 400 106.3 80-120 Magnesium 53900 50000 107.8 80-120 Manganese 434 400 108.5 80-120 Molybdenum Nickel Potassium 5110D 50000 102.2 80-120 Selenium 429 400 107.3 80-120 Silver 432 400 108.0 80-120 Sodium 52600 50000 105.2 80-120 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52142 -1F Results < IDL are shown as zero for calculation purposes (*) Outside of QC limits (anr) Analyte not requested Page 1 ai® 25 of 39 ACCUTEST. T52142 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: SERIAL DILUTION RESULTS SUMMARY Login Number: 152142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling 05/09/10 Methods: SW646 6010E Units: ug/1 T52066 -1F QC Metal Original SOL 1:5 %DIF Limits Aluminum Antimony Arsenic 0.00 0.00 NC 0-10 Barium 79.1 18.9 0.2 0-10 Beryllium Boron Cadmium 0.00 0.00 NC 0-10 Calcium 67700 64800 4.3 0-10 Chromium 0.00 0.00 NC 0-10 Cobalt Copper 9.95 11.4 14.5 (a) 0-10 Iron 0.00 0.00 NC 0-10 Lead 0.0D 0.00 NC 0-10 Magnesium 13000 12700 2.2 0-10 Manganese 0.810 2.50 208.6(a) 0-10 Molybdenum Nickel Potassium 2110 1760 16.9 (a) 0-10 Selenium 0.00 0.00 NC 0-10 Silver 0.00 0.00 NC 0-10 Sodium 77100 75500 2.1 0-10 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52142 -1F Results < IDDL are shown as zero for calculation purposes (•) Outside of QC limits (anr) Analyte not requested (a) Percent difference acceptable due to low initial sample concentration (< 50 times IDL). Page 1 t® 26 of 39 ACCUTEST. 752142 min Gulf Coast ACCUTEST. Ibn. ,..�. 1 I'S ALL 1 N THE CHEMISTRY General Chemistry QC Data Summaries Includes the following where applicable: • Method Blank and Blank Spike Summaries • Duplicate Summaries • Matrix Spike Summaries Section 7 di® 27 of 39 QAC CUTESt T52142 METHOD BLANK AND SPIKE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling Analyte Batch ID RL MB Result Spike Units Amount BSP Result BSP %Recov QC Limits Alkalinity, Bicarbonate Alkalinity, Carbonate Alkalinity, Total as CaCO3 Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Solids, Total Dissolved Specific Conductivity Sulfate Sulfide Associated Samples: Batch GN22645: T52142-1 Batch GN22666: T52142-1 Batch GN22740: T52142-1 Batch GN22741: T52142-1 Batch GN22772: T52142-1 Batch GN22830: T52142-1 Batch GP8826: T52142-1 Batch GP886O: T52142-1 Batch GP8893: T52142-1 Batch GP8894: T52142-1 (*) Outside of OC limits GN22710 GN22741 GN22772 GP8894/GN22854 GP886O/GN22797 GP8894/GN22854 GP8826/GN22729 GP8893/GN22852 GP8893/GN22852 GN22645 GN22830 GP8894/GN22854 GN22666 5.0 2.0 mg/1 5.0 0.0 mg/1 5.0 2.0 mg/1 2500 2400 0.50 0.23 mg/1 IC 10.2 0.50 0.0 mg/1 10 10.1 0.50 0.0 mg/1 10 10.5 0.10 0.010 mg/1 5.0 5.0 0.50 0.0 mg/1 10 9.74 0.50 0.0 mg/1 10 10.4 10 5.0 mg/1 500 482 1.0 <1.0 umhos/cm 0.50 0.0 mg/1 10 10.0 0.20 0.0 mg/1 1600 1540 96.0 102.0 101.0 105.0 100.0 97.4 104.0 96.4 100.0 96.2 80-1204 90-110% 90-1108 90-110% 81-121% 90-1104 90-110% 80-120% 90--1101; 80-120% Page 1 1 ..t ri 28 of 39 ACCUTEST. T52142 BLANK SPIKE DUPLICATE: RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling Analyte Spike BSD QC Batch ID Units Amount Result RPD Limit Sulfide Associated Samples: Batch GN22666: T52142-1 (•) Outside of QC limits GN22666 mg/1 1600 1540 0.0 Page 1 ® 29of39 ACEST. 752142 1 Analyte DUPLICATE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: 152142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling Batch ID QC Sample Units Original Result DUP Result RPD QC Limits Alkalinity, Bicarbonate Alkalinity, Carbonate Alkalinity, Total as CaCO3 Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Solids, Total Dissolved Specific Conductivity Sulfate PH Associated Samples: Batch GN22626: 752142-1 Batch GN22645: T52142-1 Batch 0N22740: 752142-1 Batch GN22741: T52142-1 Batch GN22772: 152142-1 Batch 01122830: 152142-1 Batch GP8826: T52142-1 Batch GP8860: T52142-1 Batch GP8893: T52142-1 Batch GP8894: T52142-1 (") Outside of QC limits GN22740 GN22741 GN22772 GP8894/GN22854 GP8860/GN22797 GP8894/GN22854 1P8826/GN22729 GP8893/GN22852 GP8893/GN22852 GN22645 GN22830 GP8894/GN22854 GN22626 151898-1 752269-1 152269-1 752063-1 T52155-2 752063-1 T52211-1 152142-1 752142-1 151976-1 151989-1 T52063-1 152155-1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 umhos/cm mg/1 su 312 5.1 298 105 40.7 66.1 0.030 0.12 U 0.12 U 651 1590 50.4 7.17 312 5.2 300 105 35.0 66.1 0.020 0.0 0.0 661 1590 50.0 7.16 0.0 0.8 0.7 0.0 15.1 0.0 40.0 0.0 0.0 1.5 0.1 0.8 0.1 Page 1 0-20% 0-20% 0-10% 0-20% 0-20% 0-20% 0-20% 0--20% 0-20% 0-5% 0-20% 0-20% 0-6.86 ®® 30 of 39 G ACC UTEST. 752142 MATRIX SPIKE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52142 Account: ENCACOP - ENCANA Project: GARCO Middle Fork Pond Sampling Analyte Batch ID QC Original Spike M5 QC Sample Units Result Amount Result %Rec Limits Alkalinity, Total as CaCO3 Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Sulfate Associated Samples: Batch GN22772: T52142-1 Batch GP8826: T52142-1 Batch GP8B60: T52142-1 Batch GP8893: T52142-1 Batch GP8894: T52142-1 (•( Outside of QC limits (N1 Matrix Spike Rec. outside GN22772 GP8894/GN22854 GP8860/GN22797 GP8894/GN22854 GP8826/GN22729 GP8893/GN22852 GP8893/GN22852 GP8894/GN22854 of QC limits T52269-1 T52063-1 T52155-2 T52063-1 T52211-1 T52142-1 T52142-1 T52063-1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 Page i 298 105 40.7 66.1 0,030 0.12 U 0.12 U 50.4 25 100 200 100 5.0 10 10 100 324 139 247 189 4.9 10.7 23.1 124 104.0 34.ON 103.2 122.9N 98.0 107.0 231.0N 73.6N 79-122% 80-120% 80-120% 80-120% 66-131% 80-120% 80-120% 80-120% ®® 31 of 39 ACaJTEST. T52142 , . 1 SUBCONTRACT COCTI4L Pdge ,_1_- RI i Hot -win, Suite Houston, ytO4ll1..Ora4. - 14114 Caaw Cenvpr 150 - TX 77036 - 713-271-4700 fax: 713-271-4770 a«wa,10.4,ra Mc.Hall4M1, 110165 k ChM Informal:':on 1 I S.Manwu IMoon, llon Pea ova lad Melva& Mauls Codes Germany home Acculesl Gull CGMS T„ ecemreul trbarptory ACCUTEST FLORIDA NOT PRESERVED OW •NAY,. wow Project Codas [male SylvhGarza sylvleg@acculese.earn Aliwatery C.&,, [malt Sample Receiving ... ��.• GW 04,44100 r wW.we...a' Aa&ass 10165Harwin Dr, Suite 150 Addrrts sw. SAae ,,,,..- urn.10165 sa • ea City Slate Zip Flousean TX 771)36 City Som 21y St. Skov. el. 0, i•aeNa NP_ 713-2714700 PS ena No. 1JO. Leek. EC k. Own stat CdleclOn Natter' Orpresecwd boa es Accuses Sample Neater Dna Irma rials, adr oozes d f 2p i 50R i tee use ONLY T52142-1 5/5/2010 W 3 X x Te 4e..470.1eu,l„ali a pats Oaiarable nlvmPtaa Conraamsr Remarks 1 M ISTAIMARD Aawa•M SWee:a: Q� Camm,4ad'A° 11 TRRP•11 TO y !-1111C44,4104111.C44,4104111.Q EOM Formal 1=14 Ory rnuSl D Reduced Tier Olba, l110ay EMERGENCY Q /ell 0aa Packepo SAMPLE NOT PRESPAYEO 1—^ J 2Day EA,ePOENCY 111Ode Fa4EAG€MCYi_ Cammtotal 'A'. Revaed°My WATCH HMSc NAPn = Db. Reel llm nalyllcat data available via Lab6nk Camew( PA '5'. Sob olio 4 alandaSOC IAMPLE CUSTODY H65T a!5OCUMENTFba(LO'H54019 TMR 56501.05 CHAN0 e bM$iEl gION,INGL41MM46 COUR fl O RY A a 1 ape Y7.._ r! ��, Paar@,rl eF 1 J'X ANwaJ,ueaY a ..x Ow.11es j7,{.4 �'� Rr< a Y 47 x Lsi4C l�[cvite. 1- %�7Jlu 6PMadlanaaay, 3 Mlle naq. NaeNvld sY: 3 Railaaulava4 a y. 4 aemNed ay: 1 a AeiAMa.Fd be 5 5 .,e.,. P.a.haa sP 5 0..444 pert Y,aawl.when PPP/"... 441u Caroler Tamp. n T52142: Chain of Custody Page 1 of 2 Accutest Laboratories Southeast, Inc. CO N 33 of 39 ACCUTEST. T52142 TEMPERATURE INFORMATION IR THERM ID `GQ 1 CORR. FACTOR -.`I OBSERVED TEMPS: I • / CORRECTED TEMPS: ''2-. 2 - SAMPLE SAMPLE INFORMATION SAMPLE LABELS PRESENT ON AIL BOTTLES INCORRECT NUMBER OF CONTAINERS USED SAMPLE RECEIVED IMPROPERLY PRESERVED INSUFFICIENT VOLUME FOR ANALYSIS DATES/TIMES ON COC DO NOT MATCH SAMPLE LABEL ID'S ON COC DO NOT MATCH LABEL VOC VIALS HAVE HEADSPACE (MACRO BUBBLES) BOTTLES RECEIVED BUT ANALYSIS NOT REQUESTED NO BOTTLES RECEIVED FOR ANALYSIS REQUESTED UNCLEAR FILTERING OR COMPOSITING INSTRUCTIONS SAMPLE CONTAINER(S) RECEIVED BROKEN % SOLIDS JAR NOT RECEIVED 5035 FIELD KIT FROZEN WITHIN 48 HOUR'S RESIDUAL CHLORINE PRESENT IAPPICABLE TO EPA 606 SERIES OR NORTH CAROLINA ORGANICS,' ACC'IJTEST LABORATORIES SAMPLE RECEIPT CONFIRMATION ACCUTEST'S JOB NUMBER: T S1.1 I -- DATE/TIME DATE/TIME RECEIVED: rj h I ID G'. no METHOD OF DELIVERY: FEDEX UPS AIRBILL NUMBERS: CLIENT: UN 16-.L PROJECT: 1 -C1 - 11 2 - (MM/DD/YY 24:00) NUMBER OF COOLERS RECEIVED: ACCUIEST COURIER GREYHOUND DELIVERY OTHER COOLER INFORMATION CUSTODY SEAL NOT PRESENT OR NOT INTACT CHAIN OF CUSTODY NOT RECEIVED (COC) ANALYSIS REQUESTED IS UNCLEAR OR MISSING SAMPLE DATES OR TIMES UNCLEAR OR MISSING TEMPERATURE CRITERIA NOT MET WET ICE PRESENT TRW BLANK INFORMATION TRIP BLANK PROVIDED TRW DLANK NOT PROVIDED TRIP BLANK NOT ON COC TItIP BLANK INTACT TRIP BLANK NOT INTACT RECEIVED WATER TRIP BLANK RECEIVED SOIL TRIP DLANK MISC. INFORMATION NUMBER OF ENCORES ? NUMBER OF 5035 FIELD KITS ? NUMBER OR LAB FILTERED METALS ? SUMMARY OF COMMENTS; TECIINICIANSIGNATURE/DATE S"ifI[1 REVIEWER SIGNATURE/DATE NF 10109 RECEIPT 'CONFIRMATION 100609 (2).5415 T52142: Chain of Custody Page 2 of 2 9 s CO egn 34 of 39 ACCIJTEST T52142 Gulf Coast ACCUTES` . I T' S ALL IN THE CHEMISTRY GC Volatiles QC Data Summaries (Accutest Laboratories Southeast, Inc. Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries Section 9 CC aril 35 of 39 QACCUTEST. T52142 Method Blank Summary Job Number: T52142 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: GARCO Middle Fork Pond Sampling Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch GXY 1823 -MB XY043929. D 1 05/11/10 CW n/a n/a GXY1823 The QC reported here applies to the following samples: T52142-1 CAS No. Compound Method: RSKSOP-147/ 175 Result RL MI)L Units Q 74-82-8 Methane ND 0.50 0.16 ug/l tip ® 36 of 39 AL'CIJTEST T52142 Blank Spike Summary Job Number: T52142 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: GARCO Middle Fork Pond Sampling 1'age 1 of 1 Sample File 1D DF Analyzed By Prep Date Prep Batch Analytical Batch GXY1823-BS XY043930. D 1 05/11/10 CW n/a n/a GXY1823 The QC reported here applies to the following samples: T52I42-1 CAS No. Compound Spike BSP BSP ug/I ugli % Limits 74-82-8 Methane 108 124 115 54-149 Method: RSKSOP-147/ 175 Mri 37 of 39 p►►ccirr ST. T52142 1 Matrix Spike Summary Job Number: T52142 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: GARCO Middle Fork Pond Sampling Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch T52143-1MS XY043938.D 1 05/11/10 CW n/a n/a GXY1823 T52143-1 XY043933. D 1 05/11/10 CW n/a n/a GXY1823 The QC reported here applies to the following samples: T52142-1 CAS No. Compound Method: RSKSOP-147/175 T52143 -I Spike MS MS ug/1 Q ug/1 ug/1 % Limits CO 74-82-8 Methane 60.2 108 201 130 54-149 ®n 38 of 39 ACCUTEST. T52142 ' Duplicate Summary Job Number: T52142 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: GARCO Middle Fork Pond Sampling Page 1 of I Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch T52143-1DUP XY043937.DI 05/11/10 CW n/a n/a GXY1823 T52143-1 XY043933.D 1 05/11/10 CW n/a n/a GXY1823 The QC reported here applies to the following samples: T52142 -I Method: RSKSOP-147/175 T52143-1 DUP CAS No. Compound ug/1 Q ug/I Q 12PI) Limits 74-82-8 Methane 60.2 60.2 0 24 egril 39 of 39 4'ACCUTEST T52142 ' 1 1 111 Gulf Coast GIACCUTEBT. r,r E.tnries 41‘114"° Sitti tI'S ALL IN THE CHEMISTRY Technical Report for ./Ati ENCANA Project NPRIMF Pond Accutest Job Number: T52155 Sampling Date: 05/05110 Report to: e -Hardcopy 2.0 Automated Report 05/19/10 EnCana 2717 Co. Rd. 215 Parachute, CO 81635 brett.middleton@encana.com; Daniel.Prokop@encan ATTN: Brett Middleton Total number of pages in report: 46 �� \N ACC01,,4 Test results contained within this data package meet the requirements of the National Environmental Laboratory Accreditation Conference and/or state specific certification programs as applicable, Client Service contact: Sylvia Garza 713-271-4700 A. con Paul Canevaro Laboratory Director Certifications: TX (T104704220 -09C -TX) AR (88-0756) FL (E87628) KS (E-10366) LA (85695/04004) OK (9103) UT(7132714700) This report shall not be reproduced, except in its entirety, without the written approval of Aecutest Laboratories. Test results relate only to samples analyzed. Gulf Coast • 10165 Harwin Drive • Suite 150 • Houston, TX 77036 • tel: 713-271-4700 • fax: 713-271-4770 • http://www.accutest.com 1 of 46 ACCUTEST T52155 ' Accutest Laboratories is the sole authority for authorizing edits or modifications to this document. Unauthorized modification of this report is strictly prohibited. Sections: Table of Contents -1- Section 1: Sample Summary 3 Section 2: Case Narrative/Conformance Summary 4 Section 3: Sample Results 8 3.1:T52155-1: MW11-050510 9 3.2: T52155 -1F: MW1 1-0505 1 0 (DISSOLVED) 12 3.3: T52155-2: MW10-050510 13 3.4: T52155 -2F: MW 10-050510 (DISSOLVED) 16 Section 4: Misc. Forms .... 17 4.1: Chain of Custody 18 Section 5: GC/MS Volatiles - QC Data Summaries 21 5.1: Method Blank Summary 22 5.2: Blank Spike Summary 24 5.3: Matrix Spike/Matrix Spike Duplicate Summary 26 Section 6: Metals Analysis - QC Data Sunlnrriries 28 6.1: Prep QC MP11742: As,Ba,Cd,Ca,Cr,Cu,Fe,Pb,Mg,Mn,K,Se,Ag,Na 29 Section 7: General Chemistry - QC Data Summaries 34 7.1: Method Blank and Spike Results Summary 35 7.2: Blank Spike Duplicate Results Summary 36 7.3: Duplicate Results Summary 37 7.4: Matrix Spike Results Summary 38 Section 8: Misc. Forms (Accutest Laboratories Southeast, Inc.) 39 8.1: Chain of Custody 40 Section 9: GC Volatiles - QC Data (Accutest Laboratories Southeast, Inc.) 42 9.1: Method Blank Summary 43 9.2: Blank Spike Summary 44 9.3: Matrix Spike Summary 45 9.4: Duplicate Summary 46 D 0 D D Co CD elin 2 of 46 ACC:IJTEST. T52155 ' D Accutest Laboratories Sample Summary ENCANA Project NPR/MF Pond Job No: T52155 Sample Collected Number Date Time By Matrix. Received Code Type Client Sample ID T52155-1 05/05/10 12:30 AS 05/06/10 AQ Water T52155 -1F 05/05/10 12:30 AS T52155-2 05/05/10 13:50 AS T52155 -2F 05/05/10 13:50 AS 05/06/10 AQ 05/06/10 AQ 05/06/10 AQ MW11-050510 Water Filtered MW 11-050510 (DISSOLVED) Water M W 10-050510 Water Filtered MW10-050510 (DISSOLVED) a® 3of46 ACCUTIE'ST. T52155 rI r i e s SAMPLE DELIVERY GROUP CASE NARRATIVE Client: ENCANA Site: Project NPR/MF Pond Job No T52155 Report Date 5/19/2010 3:50:10 PM 4 Sample(s), were collected on 05/05/2010 and were received at Accutest on 05/06/2010 properly preserved, at 3 Deg. C and intact. These Samples received an Accutest job number of T52155, A listing of the Laboratory Sample ID, Client Sample 1113 and dates of collection are presented in the Results Summary Section of this report. Except as noted below, all method specified calibrations and quality control performance criteria were met for this job. For more information, please refer to QC summary pages. Volatiles by GCMS By Method SW846 8260B Matrix AQ Batch ID: VX537 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. • T52155 -I : Reported for QC purposes only. Matrix AQ Batch ID: VX538 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. ■ Sample(s) T52155-2MS, T52155-2MSD were used as the QC samples indicated. Volatiles by GC By Method RSKSOP-147/175 Matrix AQ Batch ID: F:GFF21 1 • T52155 Analysis performed at Accutest Laboratories, Orlando, FL. Metals By Method SW846 6010B Matrix AQ Batch ID: MP11742 ■ All samples were digested within the recommended method holding lime. • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. • Sample(s) T52066-1FDUP, T52066-1FMS, T52066-IFMSD, T52066-IFSDL were used as the QC samples for metals. • RPD(s) for Serial Dilution for Copper, Manganese, Potassium are outside control limits for sample MP 11742-SD1. Percent difference acceptable due to low initial sample concentration (< 50 times IDL). Wet Chemistry By Method EPA 120.1 Matrix AQ Batch ID: GN22830 • All samples were analyzed within the recommended method holding time. ■ All method blanks for This batch meet method specific criteria. • Sample(s) T51989-1DUP were used as the QC samples for Specific Conductivity. Wednesday, May 19, 2010 Page 1 of 3 Eari 4 of 46 gj AC:L:UTEST T52155 Wet Chemistry By Method EPA 300/SW846 9056 Matrix AQ Batch ID: GP8860 • All samples were distilled within the recommended method holding time. • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. ■ Sample(s) T52155-2DUP, T52155-2MS were used as the QC samples for Chloride. Matrix AQ Batch ID: GP8893 • All samples were distilled within the recommended method holding time. • Ail samples were analyzed within the recommended method holding lime. • All method blanks for this batch meet method specific criteria. • Sample(s) T52142-1DUP, T52142 -IMS were used as the QC samples for Nitrogen, Nitrate, Nitrogen, Nitrite, Nitrogen, Nitrate. • Matrix Spike Recovery(s) for Nitrogen, Nitrite are outside control limits. Probable cause due to matrix interference. Matrix AQ Batch ID: GP8894 • • • • • Matrix Spike Recovery(s) for Bromide, Fluoride, Sulfate are outside control limits. Probable cause due to matrix interference. All samples were distilled within the recommended method holding time. All samples were analyzed within the recommended method holding time. All method blanks for this batch meet method specific criteria. Sample(s) T52063-IDUP, T52063-1MS were used as the QC samples for Bromide, Fluoride, Sulfate, Bromide. Wet Chemistry By Method SM 21 4500 NH3D Matrix AQ Batch ID: GP8826 • All samples were distilled within the recommended method holding time. • All samples were analyzed within the recommended method holding time. ▪ Alt method blanks for this batch meet method specific criteria. • Sample(s) T52211-IDUP, T52211 -IMS were used as the QC samples for Nitrogen, Ammonia. • RPD(s) for Duplicate for Nitrogen, Ammonia are outside control limits for sample GP8826-D1. Wet Chemistry By Method SM 2540C Matrix AQ Batch ID: GN22645 • All samples were analyzed within the recommended method holding time. • All method blanks for this batch meet method specific criteria. • Sample(s) T52155-1DUP were used as the QC samples for Solids, Total Dissolved, Wet Chemistry By Method SM 4500 CO2 D Matrix AQ Batch ID: GN22771 • All samples were analyzed within the recommended method holding time. • All method blanks for This batch meet method specific criteria. • Sample(s) T52269-1 DUP were used as the QC samples for Alkalinity, Bicarbonate, Wet Chemistry By Method SM 4500H+B/9040 Matrix AQ Batch ID: GN22626 ■ Sample(s) T52155-1DUP were used as the QC samples for pil. Wednesday, May 19, 2010 Page 2 of3 an 5 of 46 ® AC.`C•UTFST T52155 Wet Chemistry By Method SM 4500S+F Matrix AQ Batch ID: GN22666 ■ All samples were analyzed within the recommended method holding time. ■ All method blanks for this batch meet method specific criteria. Wet Chemistry By Method SM 18 2320B Matrix AQ Batch ID: GN2274I • All samples were analyzed within the recommended method holding time. • Ali method blanks for this batch meet method specific criteria. ■ Sample(s) T52269-1DUP were used as the QC samples for Alkalinity, Carbonate. Accutest Laboratories Gulf Coast (ALGC) certifies that this report meets the project requirements for analytical data produced for the samples as received at ALGC and as stated on the COC. ALGC certifies that the data meets the Data QualityObjectives for precision, accuracy and completeness as specified in the ALGC Quality Manual except as noted above. This report is to be used in its entirety. ALGC is not responsible for any assumptions of data quality if partial data packages are used Wednesday, May 19, 2010 Page 3 of 3 d® 6 of 46 ACCUTEST: T52155 0 SAMPLE DELIVERY GROUP CASE NARRATIVE Client: Accutest Laboratories Gulf Coast, Inc. Job No: T52155 Site: ENCACOP: Project NPR/MF Pond Report Date 5/17/2010 5:30:18 AM 2 Samples were collected on 05/05/2010 and were received at Accutest, SE on 05/07/2010 properly preserved, at 2.2 Deg. C and intact. These Samples received an Accutest job number of T52155. A listing of the Laboratory Sample ID, Client Sample ID and dates of collection are presented in the Results Summary Section of this report. Except as noted below, all method specified calibrations and quality control performance criteria were met for this job. For more information, please refer to QC summary pages. Volatiles by GC By Method RSKSOP-147/175 Matrix: AQ Batch ID: GFF21 I All samples were analyzed within the recommended method holding time. All method blanks for this batch meet method specific criteria. Sample(s) F73215-10DUP, F73215-IOMS were used as the QC samples indicated. T52155-1: Sample was not preserved to a pI-I < 2. T52155-2: Sample was not preserved to a pI-I < 2. Accutest Laboratories Southeast (ALSE) certifies that this report meets the project requirements for analytical data produced for the satnples as received at ALSE and as stated on the COC. ALSE certifies that the data meets the Data Quality Objectives for precision, accuracy and completeness as specified in the ALSE Quality Manual except as noted above. This report is to be used in its entirety. ALSE is not responsible for any assumptions of data quality if partial data packages are used Narrative prepared by: Lovelie Metzgar, QA Assistant (signature on file) Date: May 17, 2010 Monday, May 17, 2010 Page 1 of 1 agn 7 of 46 ASST. T52155 „ ® GuIf Coast ® =CUTEST IT'S ALL IN THE CFlEMISTRY Sample Results Report of Analysis Section 3 ®in 8 of 46 © ASST. T52155 ' ' Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Method: Project: MWI1-050510 T52155-1 AQ - Water SW846 8260B Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #1 Run #2 ° File ID X0061109.D X0061081. D DF 1 500 Analyzed By 05/10/10 JL 05/09/10 JL Prep Date n/a n/a Prep Batch n/a n/a Analytical Batch VX538 VX537 Run #1 Run #2 Purge Volume 5.0 mi 5.0 ml Purgeable Aromatics, MTBE CAS No. Compound 71-43-2 108-88-3 100-41-4 1330-20-7 1634-04-4 Benzene Toluene Ethylbenzene Xylene (total) Methyl Tert Butyl Ether CAS No. Surrogate Recoveries 1868-53-7 17060-07-0 2037-26-5 460-00-4 Dibromofluoromethane 1, 2-Dichloroethanc-D4 Toluene -D8 4-Bromofluorobenzene (a) Reported for QC purposes only. Result ND ND ND ND ND RL MDL Units Q 0.0020 0.00050 mg/1 0.0020 0.00043 mg/1 0.0020 0.00055 mg/1 0.0060 0.0017 mg/1 0.0020 0.00073 mg/1 Run# 1 Run# 2 Limits 92% 89% 92% 89% 93% 91% 92% 89% 79-122% 75-121% 87-119% 80-133% ND = Not detected MDL - Method Detection Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value 13= Indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound iri 9 of 46 '® ACCUTEST. T52155 ' Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Method: Project: MW 1 1-050510 T52155 -I AQ - Water RSKSOP-147/ 175 Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #I a Run #2 File ID FF04884.D DF 1 Analyzed By Prep Date 05/11/10 AFL n/a Prep Batch Analytical Batch n/a F:GFF2II CAS No. 74-82-8 Compound Methane Result RL MDL Units ND 0.00050 0.00016 mg/I Q (a) Sample was not preserved to a pH < 2. Analysis performed at Accutest Laboratories, Orlando, FL. ND = Not detected MDL - Method Detection Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value B = indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound ell© 10of46 ACCUTEST 752155 ' Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: MWI1-050510 Lab Sample ID: T52155-1 Matrix: AQ - Water Project: Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a General Chemistry Analyte Result RL MDL Units DF Analyzed By Method Alkalinity, Bicarbonate 314 5.0 0.66 mg/1 1 05/17/10 MC Alkalinity, Carbonate 1.9 B 5.0 0.66 mg/1 1 05/17110 MC Bromide 0.10 U 0.50 0.10 nig/1 1 05/15/10 22:30 BF Chloride 66.8 5.0 1.9 mg/1 10 05113/10 17:07 BF Fluoride 0.67 0.50 0.25 mg/1 1 05/15/10 22:30 13F Nitrogen, Ammonia 0.060 B 0.10 0.0060 mg/1 1 05/12/10 15:35 BF Nitrogen, Nitrate 0.78 0.50 0.12 mg/1 1 05/06/10 23:04 BF Nitrogen, Nitrite 0.32 B 0.50 0.12 mg/1 1 05/06/10 23:04 13F Solids, Total Dissolved 494 10 2.6 mg/1 1 05/07/10 BG Specific Conductivity 835 1.0 umhos/cm 1 05/17/1009:30 MC Sulfate 83.8 2.5 0.75 mg/1 5 05/15/10 21:38 BF Sulfide 0.15 U 0.20 0.15 mg/1 1 05/10/10 10:00 KD pH 7.17 su 1 05/06/10 17:00 CN SM 4500 CO2 D SM 18 2320E EPA 300/SW846 9056 EPA 300/SW846 9056 EPA 300/SW846 9056 SM 21 4500 NH3D EPA 300/SW846 9056 EPA 300/SW846 9056 SM 2540C EPA 120.1 EPA 300/SW846 9056 SM 4500S+ F SM 4500H+ B/9040 RL = Reporting Limit MDL = Method Detection Limit U = Indicates a result < MDL B = Indicates a result > = MDL but < RL On 11of46 ACCI.JTESt T52155 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Project: MW11-050510 (DISSOLVED) T52155 -1F AQ - Water Filtered Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Dissolved Metals Analysis Analyte Result RL MDL Units DF Prep Analyzed By Method Prep Method Arsenic 0.0020 U 0.0050 0.0020 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Barium 0.104 B 0.20 0.0027 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW8463010A2 Cadmium 0.00030 U 0.0040 0.00030 mg/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Calcium 70.8 5.0 0.035 nig/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Chromium 0.0019 U 0.010 0.0019 mg/I 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 2 Copper 0.0059 U 0.025 0.0059 mg/1 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 2 Iron 0.013 U 0.10 0.013 mg/1 05/09/10 05/11/10 NS SW846 6010E1 1 SW846 3010A 2 Lead 0.0017 U 0.0030 0.0017 mg/1 05/09/10 05/11/10 NS SW8466010B1 SW846 3010A 2 Magnesium 40.7 5.0 0.0078 mg/1 05/09/10 05/11/10 NS SW8466010B 1 SW846 30]0A2 Manganese 0.0076 U 0.015 0.0076 mg/1 05/09/10 05/11/10 NS SW846 60108 1 SW846 3010A 2 Potassium 2.14 B 5.0 0.053 ingll 05/09/10 05/11/10 NS SW8466010B1 SW8463010A2 Selenium 0.0032 U 0.0050 0.0032 mg/I 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 2 Silver 0.00080 U 0.010 0.00080 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Sodium 49.6 5.0 0.13 mg/ 1 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 2 (1) Llstrument QC Batch: MA4732 (2) Prep QC Batch: MP 11742 RL = Reporting Limit MDL Method Detection Limit U = Indicates a result < MDL B Indicates a result > = MDL but < RL ® 12 of 46 ACCUTEST. 752155 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample Ill: MW10-050510 Lab Sample ID: T52155-2 Matrix: Method: Project: AQ - Water SW846 8260B Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #1 Run #2 File ID X006i110.D DF 1 Analyzed By 05/10/10 JL Prep Date n/a Prep Batch Analytical Batch n/a VX538 Run #1 Run #2 Purge Volume 5.0 ml Purgcable Aromatics, MTBE CAS No. Compound 71-43-2 108-88-3 100-41-4 1330-20-7 1634-04-4 Benzene Toluene Ethylbenzene Xylene (total) Methyl Tert Butyl Ether CAS No. Surrogate Recoveries 1868-53-7 17060-07-0 2037-26-5 460-00-4 Dibromofluoromethane 1, 2-D ichloroethane-D4 Toluene -D8 4-Bromofluoroben zene Result RL MDL Units Q ND ND ND ND ND 0.0020 0.00050 mg/1 0.0020 0.00043 mg/1 0.0020 0.00055 mg/1 0.0060 0.0017 mg/1 0.0020 0.00073 mg/I Run# 1 Run# 2 Limits 92% 88% 91% 88% 79-122% 75-121% 87-119% 80-133% ND = Not detected MDL - Method Detection Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value B= Indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound ®® 13 of 46 ® =CUTEST. T52155 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix: Method: Project: MW10-050510 T52155-2 AQ - Water RSKSOP-147/ 175 Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Run #1 a Run #2 File ID FF04885.D DF 1 Analyzed By Prep Date 05/11/10 AFL n/a Prep Batch Analytical Batch n/a F:GFF211 CAS No. Compound 74-82-8 Methane Result ND RL MDL Units 0.00050 0.00016 mg/I Q (a) Sample was not preserved to a pH < 2. Analysis performed al. Aecutest Laboratories, Orlando, FL. ND = Not detected MDL - Method Detection. Limit RL = Reporting Limit E = Indicates value exceeds calibration range J = Indicates an estimated value B = Indicates analyte found in associated method blank N = Indicates presumptive evidence of a compound ®® 14of46 ACCUTEST T52155 Aecutest Laboratories Report of Analysis Page I of 1 Client Sample ID: MW10-050510 Lab Sample ID: T52155-2 Date Sampled: 05/05/10 Matrix: AQ - Water Date Received: 05/06/10 Percent Solids: n/a Project: Project NPR/MF Pond General Chemistry Analyte Result RL MOL Units DF Analyzed By Method Alkalinity, Bicarbonate 349 5.0 0.66 mg/I 1 05/17/10 MC SM 4500 CO2 D Alkalinity, Carbonate 1.2 B 5.0 0.66 mg/1 1 05/17/10 MC SM I8 2320B Bromide 6.8 0.50 0.10 mg/1 1 05/15/10 21:20 BF EPA 300/SW846 9056 Chloride 40.7 5.0 1.9 mg/I 10 05/13110 16:15 BF EPA 300/SW846 9056 Fluoride 0.89 0.50 0.25 mg/l 1 05/15/10 21:20 BF EPA 300/SW846 9056 Nitrogen, Ammonia 0.050 B 0.10 0.0060 mg/1 1 05/12/10 15:35 BF SM 21 4500 NI -13D Nitrogen, Nitrate 3.0 0.50 0.12 mg/1 1 05/06/10 23:22 BF EPA 300/SW846 9056 Nitrogen, Nitrite 1.7 0.50 0.12 mg/1 1 05/06/10 23:22 BF EPA 300/SW846 9056 Solids, Total Dissolved 673 10 2.6 mg/1 1 05/07/10 BG SM 2540C Specific Conductivity 991 1.0 umhos/cm 1 05/17/10 09:30 MC EPA 120.1 Sulfate 136 5.0 1.5 111g/1 10 05/15/10 21:03 BF EPA 300/SW846 9056 Sulfide 0.15 U 0.20 0.15 mg/1 1 05/10/10 10:00 KD SM 4500S+ F pH 7.00 Su 1 05/06/10 17:00 CN SM 4500H+ B/9040 RL = Reporting Limit U = Indicates a result < MDL MDL = Method Detection Limit B= Indicates a result > = MDL but < RL ® 15 of 46 ACCUTEST T52155 ' 1 Accutest Laboratories Report of Analysis Page 1 of 1 Client Sample ID: Lab Sample ID: Matrix:. Project: MW10-050510 (DISSOLVED) T52155 -2F AQ - Water Filtered Project NPR/MF Pond Date Sampled: 05/05/10 Date Received: 05/06/10 Percent Solids: n/a Dissolved Metals Analysis Analyte Result RL MDL Units DF Prep Analyzed By Method Prep Method Arsenic 0.0020 U 0.0050 0.0020 mg/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Barium 0.106 B 0.20 0.0027 mg/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Cadmium 0.00037 B 0.0040 0.00030 mg/l 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Calcium 83.4 5.0 0.035 mg/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Chromium 0.0019 U 0.010 0,0019 mg/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Copper 0.0101 B 0,025 0,0059 Ing/1 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Iron 0.013 U 0.10 0.013 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Lead 0.0017 U 0.0030 0.0017 mg/I 05/09/10 05/11/10 NS SW846 6010131 SW846 3010A 2 Magnesium 52.9 5.0 0.0078 mg/I 05/09/10 05/11/10 NS SW846 6010131 SW846 3010A 2 Manganese 0.0076 U 0.015 0.0076 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Potassium 2.84 B 5.0 0.053 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Selenium 0.0032 U 0.0050 0.0032 nig/I 05/09/10 05/11/10 NS SW846 601013 1 SW846 3010A 2 Silver 0.00080 U 0.010 0.00080 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 Sodium 63.2 5.0 0.13 mg/I 05/09/10 05/11/10 NS SW846 6010B 1 SW846 3010A 2 (1) Instrument QC Batch: MA4732 (2) Prep QC Batch; MP11742 RL = Reporting Limit MDL = Method Detection Limit U - Indicates a result < MDL B = Indicates a result > = MDL but < RL sig 16tat 46 ®ACCUTEST. 752155 T"A ®���\Gulf Coast ®ACCUTEST 1 T' S ALL IN THE CHEMISTRY Misc. Forms Custody Documents and Other Forms Includes the following where applicable: • Chain of Custody Section 4 Y Ann 17of46 ACCUTEST. T52155 ' CHAIN OF CUSTODY PAGE j_OF / 1 � �1�� , =� 1e . 10165 tlarain 01, Stu 150 Hannon, T7( 17056 Vat r WIN/ �b O./Lw4M! { Laboratories TEL 713-271-000 MX: 717-771--710 l.ga wwn.aaurom AzeWOreYa ate+ 0..0lat a, Z/ Si g Cllenl lReport4y Information tomi 1 4- ",,, i:--a._f. °:1 Protect Inlomnaf(en k - * ''efr �..,,fi Requested Analyses Marts Codes Compel) Name r Ie6CLS(u )1nG• Piled Warner Projth %Y MPRf111F-id ..( 'MJ 4J mv- orinsseiv. 0161• Ground Wale. ww - Weser SW SO - bon rarer SL- ankle SE08edmanr OI 0.1La0 - 00 -or !And sot " rt Ma • aloe. so -al YIP-yylPe FB Bald Blank f&Egns men!1nk RB. Pons. Blank 7B -TA, Blank swMAasU1A0 if.',a61/a.I r" i�)�caa•T ZIS.. `A..,T l n,:= _ /+Syeas W-71-1 Cir o./lc &La- J 1t_ 100 BIIlInp Manna/Jan ( If allhaanl from Rawl tnl �Cary �� "�� "(r� SW. / ap f{11aLL/(,Lt,}[,_ LLS, &I f/.3C oly State Gampor.1 Nana !'RJgd ContactEaeR Birt} f ddIdon 1:(0-4-tvtadia cek 1 Railed �11CttiYt, coat Sawn Adams Panne Il Fug ct—tc a—/3.9 CJ �7 rFay fl.rcheu Wet Lar flab le Batp�e.}•ra(d) �Nyan�aa�(s�)� Ph One 1 1 Pa.ChS S r1 Prated Marlow AgMOan. Cd'anaan la Mwrw l kale °Fawa field 167 Pala! tat Col ruction oar. ,kaeirn savor ru urea Ilan. 4 , 9 9 g r 5 LAB USE ONLY amts I I- 0S0510 os/oVID /230 A-5 w& // i 1 q X ftu..)1O-b to 0.57600 /3S0 itis turn 1/ f J 9 X Vii: Tan...... a. 15.... as royal.A'+= _.5;,-(A v.. ;J3 • ,-Yr rr`".N-54 Data DeemmMolnlamllren .. - ColmulNs Spada) iWmcl.als . :.: ^^' 1 .-. -. [V bmndw APprad ali pMculatrYl:feala' 0 5 Dry RUSH Or� eee= Caaal `A" (1.4 .l1( JITR IJ Camnerar•1.15 ( Leval 2, E0D Formol 1771 6 Day RUSH 0 FVLT1 11. vel 14 } Q mar ❑ 3Day PUSH I:3 REDTI 1 .s013 4) o x ay 505) I] Calnmar.lal •C^ El 1 Day EMERGENCY • CarnmendY'A' • Raupu Only Emaryrcy 6 Rush TIAda la wadable 5011La➢1'n4 Ccrnmarna! •8" Raub • 9C Surras Con nerda'C' = Rawls • OC A Sumjala Sum mnrl , :.31431.. , ,r ,::.L 2.. .V.:. Sample Custody must be docschemed below each time esmptos change peeseBaloe, Incluaing cowls, dayro .f1..__7,45t-U•.,,t..ta-Z,-s:- ; R.naa ha Bain 1 _ eaan.4: 0 0 /0 1730 Ruvind Or 1 ARM, NT., Or 1 Me Time: waver Or 2, . r..h.„, ,L, g bare oma: Roc. Md Or 3 Nana. mad Rn , F /11 E. -la a1 Glia 'Slr1 1 Vta011.10 il.11.1.1 7,.d is,.: - 5 -noun: R.alred By: 5 Ca.ada.We 0 I.. Pnwmtl.Man apilutla 011 Ya Codi TampN.Inlacl 0 61 1.0 T52155: Chain of Custody Page 1 of 3 4. k±p 18of46 ACCUTEST. T52155 SAMPLE INSPECTION FORM AccutestJob Number: r11-Z/2.T Client: rvifePf lt, fh / g (is # of Coolers Received: / Thermometer #: //O Date/Time Received: 5- A/n n�3d Temperature Adjustment Factor: — o _ Cooler Temps: #1: © #2: #3: 114: #5: #6: Method or Delivery: .dh,j i. UPS Accutest Courier Greyhound Delivery Other #7: #8: Airbll.l Numbers: COOLER INFORMATION pCusiody scat missing or not. intact Temperature criteria not met Wet ice received In cooler C.IIAIN OF CUSTODY Chain of Custody not received Sample D/Tunctear or missing Analyses unclear ar missing COC not properly executed Summary of Discrepancies: SAMPLE INFORMATION Sample containers received broken VOC vials have headspace Sample labels mtssing or illegibie ID on COC does not match labells) D/T on COC does not match label(s) Sample/Bottles rcvd but no analysis on COC Sample listed on COC, but not received Battles missing for requested analysts Insufficient volume (or analysis Sample received Improperly preserved TRIP BLANK INFORMATION -Dip Blank on COC but not received Trip Blank received but not on. COC Trip Blank not Intact Received Water nip BIank Received Soli TB Number of Encores? Number ar 5035 kits? Number of labtlltered metals? TECHIITCIAN SIGNATURE/DATE: INFORMATION AND SAMPLE BY: Client Representative Notified: Fly Accatest Representative: Client instructions: CORRECTIVE ACTIONS • Date: Via: Phone Email I e . I.MuahcNnefssmcii+n nv,.mom T52155: Chain of Custody Page 2 of 3 MI 19 of 46 ACCUT'ES% T52155 JOB*: CLIENT: SAMPLE RECEIPT LOG DATEFTIME RECEIVED: 6.- 116 /10 0940 Etre CA .7 F O r I Iv, INITIALS: r13 COOLER! SAMPLE ID FIELD ID DATE MATRIX VOL SOTULE a LOCATION PRESERV _ PN _ 0 2 3 4 >12 I I tw-u N1 Pk4 f- z 3 Q 5 8 7 B (fl 2 3 4 >12 P so 3 1 f 1; s 6 7 0 '1, GI 1 2 3 a At 3-0 1 i9 a 7 2.-A2>,2 -11v 1at 4 7 °2 >12 �O, / 5 B B _ �/ m 2 3 4 c2 >12 2 tw—[9 w pLi- I-7- 5 6 7- e PO 1 1)9 I N 4! 5 8 73 9 4 c2 >12 y� 1® 20 402-0 / 7 M �4 c2 >12 �! r ' 2. N r / S 6 7 8� <2 >12 - 4. ' 4 Cir• 3�1 r— >12 q _ ---v 5 1 2 c2 >12 5 7 B r 1 I_ i0 2 5 B 3 .4 T a c2 >12 1;Y"1y fI 1 2 5 B 3 4 7 B <2 >12 to 1 2 3 4 5 a 7 5 <2 512 1 2 3 '4 c2 >12 5 6 7 8 r _ 1 2 ._. 3 4 5 6 T B / / 1 2 5 B 3 4 7 8 c2 >12 1 2 3 -4 - s2 >12 5 B T 8 1 2 3 A >12 5 6 7 a 1 2 3 '4 s2 >12 5 6 T 8 1 2 3 4 c2 >12 5 6 7 8 3 4 1 <2 >12 7 6 5 5 PRESERVATIVES: 1: None 2: HCL 3: HNO3 4: H2SO4 5; NADH 6: DI 7: WON 8: Other LOCATION: 1: Walk -In 81 (Waters} 2: Walk -In #2 (Soils} VR: Voialile Fridge M: Metals SUB: Subcontract EF: Encore Freezer T52155: Chain of Custody Page 3 of 3 41. 22 20 of 46 AY T52155 Gulf Coast ACCUTEST. 11'5 ALL IN THE CHEMISTRY GC/MS Volatiles QC Data Summaries Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Matrix Spike and Duplicate Summaries Section 5 amn 21 of 46 ACCUTEST. T52155 Method Blank Summary Job Number: T52155 Account: ENCACOP ENCANA Project: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Balch Analytical Batch VX537-MB X0061080.D 1 05/09/10 JL nla nla VX537 The QC reported here applies to the following samples: T52155 -I Method: SW846 8260E CAS No. Compound Result RL MDL Units Q CAS No. Surrogate Recoveries Limits 1868-53-7 Dibromofluoromethane 92% 79-122% 17060-07-0 1,2-Diehloroethane-D4 89% 75-121% 2037-26-5 Toluene -D8 92% 87-119% 460-00-4 4-Bromofluorobenzene 89% 80-133% En 22 of 46 ® A.CCIJTEST. T52155 ' Method Blank Summary Job Number: T52I55 Account: ENCACOP ENCANA Project: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch VX538-MB X0061I05.D 1 05/10/10 J[, n/a n/a VX538 The QC reported here applies to the following sarnples: T52155-1, T52155-2 Method: SW846 8260B CAS No. Compound Result RL MDL Units Q 71-43-2 Benzene ND 2.0 0.50 ug/I 100-41-4 Ethylbenzene ND 2.0 0.55 ug/1 1634-04-4 Methyl Tert Butyl Ether ND 2.0 0.73 ug/l 108-88-3 Toluene ND 2.0 0.43 ug/I 1330-20-7 Xylene (total) ND 6.0 1.7 ug/I CAS No. Surrogate Recoveries Limits 1868-53-7 Dibromofluoromethane 93% 79-122% 17060-07-0 1,2-Dichloroethane-D4 91% 75-121% 2037-26-5 Toluene -D8 92% 87-119% 460-00-4 4-Bromofluorobenzene 88% 80-133% ®® 23 of 46 ACCUTEST. T52155 1 Blank Spike Summary Job Number: T52155 Account: ENCACOP ENCANA Project: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch VX537-BS X0061078.D 1 05/08/10 JL n/a n/a VX537 The QC reported here applies to the following samples: T52155-1 Spike BSP BSP CAS No. Compound ug/1 ug/1 % Limits CAS No. Surrogate Recoveries BSP Limits 1868-53-7 Dibromofluoromethane 91% 79-122% 17060-07-0 1, 2-Dichloroethane-D4 90% 75-121% 2037-26-5 Toluene -D8 95% 87-119% 460-00-4 4-Bromofluorobenzene 90% 80-1330%0 Method: SW846 8260B N N 19 24of46 ACCUTEST. T52155 Blank Spike Summary Job Number: T52155 Account: ENCACOP ENCANA Project: Project NPR./MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch VX538-BS X0061103.D 1 05/10/10 ]L n/a n/a VX538 The QC reported here applies to the following samples: T52155 -I, T52I55-2 CAS No. Compound Spike BSP BSP ug/I ug/1 % Limits 71-43-2 Benzene 25 23.2 93 76-118 100-41-4 Ethylbenzene 25 24.2 97 75-112 1634-04-4 Methyl Tert Butyl Ether 25 20,0 80 65-113 108-88-3 Toluene 25 23.4 94 77-114 1330-20-7 Xylene (total) 75 71.5 95 75-111 CAS No. Surrogate Recoveries BSP Limits 1868-53-7 Dibromotluoromethane 90% 79-122% 17060-07-0 1,2-Dichloroethane-D4 87% 75-121% 2037-26-5 Toluene -D8 93% 87-119% 460-00-4 4-Bromofluorobenzenc 90% 80-133% Method: SW846 8260B N ERN 25of46 4 T52155 Matrix Spike/Matrix Spike Duplicate Summary Job Number: T52155 Account: ENCACOP ENCANA Project: Project NPR/MF Pond Page 1 of 1 Sample T52155 -IMS T52155- I MSD T52155-1 a File ID DF X0061082.D 500 X0061083.D 500 X0061081, D 500 Analyzed By 05/09/10 JL 05/09/10 JL 05/09/10 JL Prep Date Prep Batch n/a n/a n/a n/a n/a n/a Analytical Batch VX537 VX537 VX537 The QC reported here applies to the following samples: T52155-1 CAS No. Compound CAS No. Surrogate Recoveries 1868-53-7 Dibromofluoromethane 17060-07-0 1,2-Dichloroethane-D4 2037-26-5 Toluene -D8 460-00-4 4-Bromofluorobenzene (a) Reported for QC purposes only. T52155 -I Spike MS ug/I Q ug/I ug/I Method: SW846 8260B MS MSD MSD Limits % ug/I % RPD Rec/RPD MS MSD T52155-1 Limits 92% 91% 93% 79-122% 88% 91% 91% 75-121% 92% 92% 92% 87-119% 89% 91% 89% 80-133% th is © 26of46 ® AC[ JTEST. T52155 Matrix Spike/Matrix Spike Duplicate Summary Job Number: T52155 Account: ENCACOP ENCANA Project: Project NPR/MF Pond Page 1 of 1 Sample T52155-2MS T52155-2MSD T52155-2 File ID DF X0061111.D 1 X0061112.D 1 X0061110.D 1 Analyzed By 05/10/10 JL 05/10/10 JL 05/10/10 JL Prep Date Prep Batch n/a n/a n/a n/a tv'a n/a Analytical Batch VX538 VX538 VX538 The QC reported here applies to the following samples: T52155-1, T52155-2 CAS No. Compound 71-43-2 100-41-4 1634-04-4 108-88-3 1330-20-7 Benzene Ethylbenzene Methyl Tert Butyl Ether Toluene Xylene (total) CAS No. Surrogate Recoveries 1868-53-7 Dibromofluoroniethane 17060-07-0 1, 2-D ichloroethane-D4 2037-26-5 Toluene -D8 460-00-4 4-Bromofluorobenzene Method: SW846 8260B T52155-2 Spike MS MS MSD MSD Limits ug/t Q ug/I ug/I % ug/I % RPD Rec/RPD ND ND ND ND ND MS 91% 89%© 93% 92% 25 22.2 89 25 23.5 94 25 19.8 79 25 23.1 92 75 70.6 94 20.8 83 7 76-118/16 21.9 88 7 75-112/12 19.1 76 4 65-113/13 22.1 88 4 77-114/12 65.9 88 7 75-111/12 MSD T52155-2 Limits 92% 92% 89% 93% 91% 88% 93% 88% 79-122% 75-121% 87-119% 80-133% EM® 27of46 AtLfTEST. T52155 ® Gulf Coast ACCUTEST. ST'S ALL IN THE CHENiSTRY Metals Analysis QC Data Summaries 'Includes the following where applicable: • Method Blank Summaries • Matrix Spike and Duplicate Summaries • Blank Spike and Lab Control Sample Summaries • Serial Dilution Summaries Section 6 0) ® 28 of 46 ACCUTEST T5215S QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: BLANK RESULTS SUMMARY Part 2 - Method Blanks Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond 05/09/10 Methods: SW846 6010B Units: ug/1 Metal MB RL IDL MDL raw final Aluminum 200 16 Antimony 5.0 2.3 3 Arsenic 5.0 1.6 2 -1.1 <5.0 Barium 200 .14 2.7 0.0 <200 Beryllium 5.0 ,11 .2 Boron 100 1.1 2.1 Cadmium 4.0 .25 .3 -0.040 <4.0 Calcium 5000 5.4 35 5.3 <5000 Chromium 10 1.1 1.9 -1.3 <10 Cobalt 50 .5 .8 Copper 25 .50 5.9 1,0 <25 Iron 100 13 13 -14 <100 Lead 3.0 1.6 1.7 -0.29 <3.0 Magnesium 5000 6.7 7.8 -2.3 <5000 Manganc.ac 15 .2 7.6 0.40 <15 Molybdenum 10 .96 1.3 Nickel 40 .95 3.2 Potassium 5000 53 53 -52 <5000 Selenium 5.0 3.2 3.2 2.7 <5.0 Silver 10 .85 .8 0.020 <10 Sodium 5000 130 130 -110 <5000 Strontium 20 .17 .4 Thallium 10 3.2 2.6 Tin 20 1.8 2.9 Titanium 20 .3 .3 Vanadium 50 .6 .6 Zinc 20 .49 4.1 Associated samples MP11742: T52155 -1F, T52155 -2F 17 Results < IDL are shown as zero for calculation purposes V) Outside of QC limits ianr) Analyte not requested Page 1 ® 29 of 46 ACC U EST. T52155 MATRIX SPIKE AND DUPLICATE RESULTS SUMMARY Login Number: T52155 Account: ENCACOP - ENCANA Project:. Project NPR/MF Pond QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: 05/09/10 Methods: SW846 60106 Units: ug/1 05/09/10 Metal T52066 -1F QC T52066 -1F Spikelot QC Original OUP RPD Limits Original MS MPTW4 9 Rec Limits Aluminum Antimony Arsenic 0.0 0.0 NC 0-20 0.0 402 400 100.5 80-120 Barium 79.1 77.1 2.6 0-20 79.1 519 400 110.0 80-120 Beryllium Boron Cadmium 0.0 0.0 NC 0-20 0.0 400 400 100.0 80-120 Calcium 67700 65900 2.7 0-20 67700 121000 50000 106.6 80-120 Chromium 0.0 0.0 NC 0-20 0.0 417 400 104.3 80-120 Cobalt Copper 10 9.2 8.3 0-20 10 435 400 106.3 8.0-120 Iron 0.00 0.0 NC 0-20 0.00 52100 50000 104.2 80-120 Lead 0.0 0.0 NC 0-20 0.0 405 400 101.3 80-120 Magnesium 13000 12700 2.3 0-20 13000 65600 50000 105.2 80-120 Manganese 0.81 0.83 2.4 0-20 0.81 420 400 104.8 80-120 Molybdenum Nickel Potassium 2110 2060 2.4 0-20 2110 53800 50000 103.4 80-120 Selenium 0,0 0.0 NC 0-20 0.0 412 400 103.0 80-120 Silver 0.0 0.0 NC 0-20 0.0 420 400 105.0 80-120 Sodium 77100 75300 2.4 0-20 77100 131000 50000 107.8 80-120 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52155 -1F, T52155 -2F Results < IDL are shown as zero for calculation purposes (*) Outside of QC limits (N) Matrix Spike Rec. outside of QC limits (anr) Analyte not requested Page 1 3O of 46 ® ACCOST. T52155 MATRIX SPIKE AND DUPLICATE RESULTS SUMMARY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond QC Batch ID: MP11742 Methods: SW846 60100 Matrix Type: AQUEOUS Units: ug/1 Prep Date: 05/09/10 Metal T52066 -1F Spikelot MSD QC Original MSD MPTW4 % Rec RPD Limit Aluminum Antimony Arsenic 0.0 403 400 100.8 0.2 20 Barium 79.1 528 400 112.2 1.7 20 Beryllium Boron Cadmium 0.0 403 400 100.8 0.7 20 Calcium 67700 124000 50000 112.6 2.4 20 Chromium 0.0 423 400 105.8 1.4 20 Cobalt Copper 10 443 400 108.3 1.6 20 Iron 0.00 52800 50000 105.6 1.3 20 Lead 0.0 409 400 102.3 1.0 20 Magnesium 13000 67000 50000 108.0 2.1 20 Manganese 0.81 426 400 106.3 1.4 20 Molybdenum Nickel Potassium 2110 54100 50000 104.0 0.6 20 Selenium 0.0 420 400 105.0 1.9 20 Silver 0.0 425 400 106.3 1.2 20 Sodium 77100 134000 50000 113.8 2.3 20 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11712: T52155 -IF, T52155 -2F Results < IDL are shown as zero for calculation purposes (*) Outside of QC limits (N) Matrix Spike Rec. outside of QC limits (anr) Analyte not requested Page 2 9, N E® 31 of 46 paccst T52155 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: SPIKE BLANK AND LAB CONTROL SAMPLE SUMMARY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond 05/09/10 Methods: SW846 60100 Units: ug/1 Metal BSP Spikelot QC Result MPTW4 % Rec Limits Aluminum Antimony Arsenic 412 400 103.0 80-120 Barium 456 400 114.0 80-120 Beryllium Boron Cadmium 420 400 105.0 80-120 Calcium 53900 50000 107.8 80-120 Chromium 434 400 108.5 80-120 Cobalt Copper 440 400 110.0 80-120 Iron 54300 50000 108.6 80-120 Lead 425 400 106.3 80-120 Magnesium 53900 50000 107.8 80-120 Manganese 434 400 108.5 80-120 Molybdenum Nickel Potassium 51100 50000 102.2 80-120 Selenium 429 400 107.3 80-120 Silver 432 400 108.0 80-120 Sodium 52600 50000 105.2 80-120 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52155 -1F, T52155 -2F Results < IDL are shown as zero for calculation purposes (*) Outside of QC limits (anr) Analyte not requested Page 1 In 32 of 46 ACCUTEST. T52155 QC Batch ID: MP11742 Matrix Type: AQUEOUS Prep Date: SERIAL DILUTION RESULTS SUMMARY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond 05/09/10 Methods: SW846 6010F Units: ug/1 T52066 -1F QC Metal Original SOL 1:5 %DIF Limits Aluminum Antimony Arsenic 0.00 0.00 NC 0-10 Barium 79.1 78.9 0.2 0-10 Beryllium Boron Cadmium 0.00 0.00 NC 0-10 Calcium 67700 64800 4.3 0-10 Chromium 0.00 0.00 NC 0-10 Cobalt Copper 9.95 11.4 14.5 (a) 0-10 Iron 0.00 0.00 NC 0-10 Lead 0.00 0.00 NC 0-10 Magnesium 13000 12700 2.2 0-10 Mangancac 0.810 2.50 208.6(a) 0-10 Molybdenum Nickel Potassium 2110 1760 16.9 (a) 0-10 Selenium 0.00 0.00 NC 0-10 Silver 0,00 0.00 NC 0-10 Sodium 77100 75500 2.1 0-10 Strontium Thallium Tin Titanium Vanadium Zinc Associated samples MP11742: T52155 -1F, T52155 -2F Results < IDL are shown as zero for calculation purposes (`) Outside of QC limits lane) Analyte not requested (a) Percent difference acceptable due to low initial sample concentration (< 50 times IDL). Page 1 gin 33of46 ©ACCUTEST. 752155 Gulf Coast ACCUTEST. 11'S ALL IN THE CH1<MISTHY General Chemistry QC Data Summaries Includes the following where applicable: • Method Blank and Blank Spike Summaries • Duplicate Summaries • Matrix Spike Summaries Section 7 Mi® 34 of 46 AST. 152155 METHOD BLANK AND SPIKE RESiULTS SUMMARY GENERAL CHEMISTRY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond Analyte MB Spike BSP BSP QC Batch ID RL Result Units Amount Result %Recov Limits Alkalinity, Bicarbonate Alkalinity, Carbonate Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Solids, Total Dissolved Specific Conductivity Sulfate Sulfide GN22771 5.0 GN22741 5.0 GP8894/GN22854 0.50 GP8860/GN22797 0.50 GP8894/GN22854 0.50 GP8826/GN22729 0.10 GP8893/GN22852 0.50 GP8893/GN22852 0.50 GN22645 10 GN22830 1.0 GP8894/GN22854 0.50 GN22666 0.20 Associated Samples: Batch GN22645: T52155-1, T52155-2 Batch GN22666: T52155-1, T52155-2 Batch 01422741: T52155-1, 152155-2 Batch GN22771: T52155-1, T52I55-2 Batch GN22830: T52155 -I, T52155-2 Batch GP8826: T52155-1, T52155-2 Batch GP8860: T52155-1, T52155-2 Batch GP8893: T52155-1, T52155-2 Batch GP8894: T52155-1, T52155-2 (*) Outside of QC limits 2.0 0.0 0.23 0.0 0.0 0.010 0.0 0.0 5.0 <1.0 0.0 0.0 mg/1 mg/1 mg/1 10 mg/1 10 mg/1 10 mg/1 5.0 mg/1 10 mg/1 10 mg/1 500 umbos/cm mg/1 10 mg/1 1600 10.2 102.0 90-110% 10.1 101.0 90-110% 10.5 105.0 90-110% 5.0 100.0 81-121% 9.74 97.4 90-110% 10.4 104.0 90-110% 482 96.4 80-120% V 10.0 100.0 90-1105 1540 96.2 80-120% Pack 1 M® 35 of 46 AcGUThST T52155 BLANK SPIKE DUPLICATE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond Analyte Spike BSP QC Batch ID Units Amount Result RPD Limit Sulfide GN22666 Associated Samples: Batch GN22666; T52155-1, T52155-2 1.) Outside of QC limits mg/1 1600 1540 0.0 Page 1 N M® 36 of 46 ACC:IJTEST. T52155 ° DUPLICATE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond Analyte Batch ID QC Original DUP QC Sample Units Result Result RPD Limits Alkalinity, Bicarbonate Alkalinity, Carbonate Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Solids, Total Dissolved Specific Conductivity Sulfate PH GN22771 GN22741 GP8894/GN22854 GP8860/GN22797 GP8894/GN22854 GP8826/GN22729 GP88931GN22852 GP8893/GN22852 GN22645 GN22830 GP8894/GN22854 GN22626 Associated Samples: Batch GN22626: T52155-1, T52155-2 Batch GN22645: T52155-1, T52155-2 Batch GN22741: T52155-1, T52155-2 Batch GN22771: T52155-1, T52155-2 Batch GN22830: T52155-1, T52155-2 Batch GP8826: T52155-1, T52155-2 Batch GP8860: T52155-1, T52155-2 Batch GP8B93: T52155-1, T52155-2 Batch GP8894; T52155-1, T52155-2 (") Outside of QC limits T52269-1 T52269-1 T52063-1 T52155-2 T52063-1 T52211-1 T52142-1 T52142-1 T52155-1 T51989--1 T52063-1 T52155-1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 umhos/cm mg/1 su 368 5.1 105 40.7 66,1 0.030 0.12 0.12 494 1590 50.4 7,17 295 5.2 105 35.0 66,1 0.020 U 0.0 U 0.0 500 1590 50,0 7.16 0.7 0.8 0.0 15.1 0.0 40.0 0.0 0.0 1.2 0.1 0.8 0.1 0-204 0-20% 0-20% 0-20% 0-20% 0-20% 0-20% 0-20% 0-5% 0-20% 0-20% 0-6.84 Page 1 fril 37 of 46 ACCUTEST T52155 _t MATRIX SPIKE RESULTS SUMMARY GENERAL CHEMISTRY Login Number: T52155 Account: ENCACOP - ENCANA Project: Project NPR/MF Pond QC Original Spike MS QC Analyte Batch ID Sample Units Result Amount Result %Rec Limits Bromide Chloride Fluoride Nitrogen, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Sulfate GP8894/0N22854 GP8860/GN22797 GP889410N22854 GP8826/GN22729 GP8893/GN22852 GP8893/GN22852 CP8894/GN22854 Associated Samples: Batch GP8826: T52155-1, 152155-2 Batch GP8860: 152155-1, 152155-2 Batch GP8893: 152155-1, 152155-2 Batch GP8894: T52155-1, T52155-2 (') Outside of QC limits (N) Matrix Spike Rec. outside of QC limits T52063-1 T52'155-2 152063-1 T52211-1 T52142-1 T52142-1 T52063-1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 mg/1 105 40.7 66.1 0.030 0.12 U 0.12 U 50.4 100 200 100 5.0 10 10 100 139 247 189 4.9 10.7 23.1 124 34.0N 103.2 122.9N 98.0 107.0 231.0N 73.6N 80-120% 80-1206 80-1201 66-131% 80-120% 80-120% 80-1206 Page 1 -1 ® 38 of 46 ACCUTEST. T52115 Guff Coast ACCU1'EST. J T' S All. ltd THE CHEMISTRY Misc. Forms Custody Documents and Other Forms (Accutest Laboratories Southeast, Inc.) Includes the following where applicable: • Chain of Custody Section 8 00 M© 39 of 46 AQCUTEST. T52155 SUBCONTRACT COC Tsis3 Page]_. 31- 1 - 10165 Harwln, Suite 150 • Houston, TX 77036 - 713-271-4700 Fax: 713-271-4770 776E7 f,c.ln77 aeni.a,l.r Coral• ,4.,,1„.17761„ A•aulnlJob l 1 CIIIrbl Inlarmallnn. 1 1 SYb.antrll Infornutlon Reque Leel Mnlya. Matrll Cod Campo., Nem. ACCulesl GUI Coria SWXMIMI Leb:Nlal ACCUTEST FLORIDA w a & E NOT PRESERVED .. W.AMI Wap. VAAl-N•aa•+to 1*.1 Ora Waa. so -s., It • 7.777 as or HD 1pld oot, OPd•5Wd Project Canint EeTA-_... .......p. Sylvia Garza *ylyikeNaccutesicam llba.ell:jtn.wce_—._�._. .-- OmYI'..-.«_--_-.__.__. Sample Receiving Addeo.. 19165 HarYAn Dr, Saila 150 MD." uty 11717 Ap HODSIOD TX 77030 CII7 ilea x10 PNene Na 713-271-4700 Mena Ha Cahalan Number o/aieseiwa 0a11 DS Acculesl Sarnpla Numberma 0. y . a. 1 g a i 4 5 g a ata lgSE ONLY T52155-1 515/2910 3 X X T52155.2 5/5112010 W 3 X X 1 TuraaIwld Tient .Lunn. 0.11r rm. a.s• ,.401.7, yn Cowman/ n. 1 X 'STANDARD N.J.dl fl. ---y l...J Ce.nnw,741'A' I=11TARP -11 1 1 T Oar � cf.1.9. IJ 600 F.,nu1 [v,.,mr 1 1 A D•T miss I I t My EYEADINCT Q Reduced Tier [D OM., ._- ______ M iu1 6.1. Peeeaba F(NPLF N57 PRESERVED Lary ENERGENCr T-- 1 Day SWEAO[NCY Camrn.rtlel •A' • Rasa Ds Only WATON HOLD TIMED —] Ibex Car mer.IN'6' . Raaull. & Sonde+d DC Real me analycal data available via Labffnk 1 IANPLt ell 2 11T1D MUM EACH TIAE SAMPLES CNANae0SSSESSION, IN CL UDIN0 COO 1e bt L.ve RY 4.. %. 1 Pre Nor z F�7C 5%7%10 7 � (�/ '� yk7�k ? `u- 1747n... b.wwd gr S 1777 Iv, 4 a Or AwlrAwagell" 'S wa,,.u,m.W 5 Ng, T.. AapNM aY 5 CvwN ENS • Amex. MOW a.11R.th .4a Cwplrr'Ty}on. o SiT ; . T52155: Chain of Custody Page 1 of 2 Accu test Laboratories Southeast, inc. 03 lire 40 of 46 © ACCUTEST. T52155 ACCUTEST LABORATORIES SAMPLE RECEIPT CONFIRMATION ACCUTEST'S JOB NUMBER: T52.155 DATE/TIME RECEIVED: 511 jQ :� METHOD OF DELIVERY: 1 AIRBILL NUMBERS: CLIENT: tit"11 PROJECT: T 52 1Fj5 IMMIDDIYY 24:00) FED' UPS ACCUTEST COURIER 7135 /1,1t. p -'-)a COOLER INFORMATION CUSTODY SEAL NOT PRESENT OR NOT INTACT CHAIN 01? CUSTODY NOT RECEIVED (COC) ANALYSIS REQUESTED IS UNCLEAR OR MISSING SAMPLE DATES OR TIMES UNCLEAR OR MISSING TEMPERATURE CRITERIA NOT MET WET ICE PRESENT TRIP BLANK INFORMATION TRU' BLANK PROVIDED TRIP BLANK NOT PROVIDED TRIP BLANK NOT ON COC TRIP BLANK INTACT TRW BLANK NOT INTACT RECEIVED WATER TRIP BLANK RECEIVED SOIL TRIP BLANK MSC. INFORMATION NUMBER OF ENCORES 7 NUMBER OF 5035 FIELD KITS 7 NUMBER OR LAB FILTERED METALS 7 SUMMARY 01? COMMENTS: NUMBER OF COOLERS RECEIVED: GREYHOUND DELIVERY OTHER TEMPERATURE INFORMATION IRTHERM ID LQ[ CORR,FACTOR # OBSERVED TEMPS: CORRECTED TEMPS: 2.2 SAMPLE INFORMATION . SAMPLE LAPELS PRESENT ON ALL BOTTLES INCORRECT NUMBER OF CONTAINERS USED SAMPLE RECEIVED IMPROPERLY PRESERVED INSUFFICIENT VOLUME FOR ANALYSIS DATES/TIMES ON COC DO NOT MATCH SAMPLE LABEL ID'S ON COC DO NOT MATCH LABEL VOC VIALS HAVE HEADSPACE (MACRO BUBBLES) BOTTLES RECEIVED BUT ANALYSIS NOT REQUESTED NO BOTTLES RECEIVED FOR ANALYSIS REQUESTED UNCLEAR FILTERING OR COMPOSITING INSTRUCTIONS SAMPLE CONTAINER(S) RECEIVED BROKEN % SOLIDS JAI( NOT RECEIVED 5035 FIELD KIT FROZEN WITHIN 41 HOUR'S RESIDUAL CHLORINE PRESENT {APPICABLE TO EPA 600 SERIES OR NORTII CAROLINA ORGANICS}' 00 TECHNICIAN SIGNATURE/DATE ` SP/IU REVIEWER SIGNATURE/DATE NE 10100 RECEIPT CONFIRMATION 100609 (2).x15 T52155: Chain of Custody Page 2 of 2 ran 41 of 46 ACCUTEST. T52155 Gulf Coast ACCURST IT'S ALL 1 N THE CIIEMISTRY GC Volatiles QC Data Summaries (Accutest Laboratories Southeast, Inc.) Includes the following where applicable: • Method Blank Summaries • Blank Spike Summaries • Malrix Spike and Duplicate Summaries Section 9 (D ai® 42 of 46 jACCUTEST T52155 Method Blank Summary Job Number: T52155 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Balch Analytical Batch GFF2I1-MB FF04879.D 1 05/11/10 WV n/a n/a GFF21I The QC reported here applies to the following samples: T52155-1, T52155-2 Method: RSK,SOP-147/ 175 CAS No. Compound Result RL MDL Units Q 74-82-8 Methane ND 0.50 0.16 ug/1 CD fElni 43 of 46 ACCUTEST. T52155 Blank Spike Summary Job Number: T52155 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: Project NPR/MF Pond Page 1 of 1 Sample File 11) DF Analyzed By Prep Date Prep Batch Analytical Batch GFF211-BS FF04880.D 1 05/11/10 WV n/a n/a GFF211 The QC reported here applies to the following samples: T52155-1, T52155-2 CAS No. Compound Spike BSP BSP ug/I ug/1 % Limits 74-82-8 Methane 108 123 114 54-149 Method: RSKSOP-147/ 175 CO MIN B44 of 46 ACCUTEST. T52155 Matrix Spike Summary Job Number: T52155 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch F73215-10MS FF04883.D 1 05/11/10 WV n/a n/a GFF211 F73215-10 FF04881.D 1 05/11/10 WV n/a n/a GFF211 The QC reported here applies to the following samples: T52155-1. T52155-2 CAS No. Compound 74-82-8 Methane Method: RSKS©P-147/ 175 F73215-10 Spike MS MS ug/I Q ug/I ug/I % Limits ND 108 140 130 54-149 ca On 45of46 ASST. T52155 Duplicate Summary Job Number: T52155 Account: ALGC Accutest Laboratories Gulf Coast, Inc. Project: ENCACOP: Project NPR/MF Pond Page 1 of 1 Sample File ID DF Analyzed By Prep Date Prep Batch Analytical Batch F73215-IODUP FF04882.D 1 05/11/10 WV n/a n/a GFF2I 1 F73215-10 FF04881.D 1 05/11/10 WV n/a n/a GFF21I The QC reported here applies to the following samples: T52155-1, T52155-2 CAS No. Compound 74-82-8 Methane Method: RSKSOP-147/ 1.75 F73215-10 I) L J I' ug/1 Q ug/I Q RPU Limits ND NI) tic 24 tD ran 46 of 46 ©QCCUTEST. T52155