HomeMy WebLinkAboutOWTS Installation Observations 12.18.14 December 18, 2014 Project No. C1113 Marissa Hickmon 46145 Hwy 6 Glenwood Springs, CO 81601 mchickmon@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 4-Bedroom Residence 46145 Hwy 6 Garfield County, Colorado Permit # SEPT-12-14-3472 Marissa, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on December 12, 2014 for the subject property. Miles Rippy Excavating, Inc. installed the system. The installation included the existing 1000 to 1250-gallon single compartment septic tank, followed by a new 500-gallon, single-compartment Valley Precast concrete septic tank with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. A new distribution box was installed and distributes effluent to three gravelless chamber beds. The exact figuration of the design was not feasible due to site constraints. At the time of the inspection, the southern-most bed was plumbed differently, as shown on photos provided. Requested changes were implemented and the record drawing reflects the actual configuration of the installation. The southern-most bed consists of one row of 4, one row of 5, and one row of 6 ADS ® ARC 36 chambers for a total of 15 ADS® ARC 36 chambers. The middle bed consists of one row of 6 and one row of 7 ADS® ARC 36 chambers for a total of 13 chambers. The northern-most bed consists of three rows of 7 ADS® ARC 36 chambers for a total of 21 chambers. While the distribution is not divided equally, this should not inhibit the functioning of the system. The minimum setback of 20-feet from the house to the STA and 10-feet from the STA to any property line was maintained. The existing distribution box and STA were removed. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OW TS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P.E. December 12, 2014 Effluent filter inside 500-gallon tank Distribution box This pipe was removed. This single row of 6 was plumbed into a manifold that connects the southern-most rows of 4 and 5 chambers with a level manifold. 832‐R‐13‐002