HomeMy WebLinkAboutApplicationO
Garfield County
Commtunity Development Department
108 8th Street, Suite 401
DEC 2 atwood Springs, CO 81601
4970) 945-8212
twww Ra eld-countv.com
BUILDING PERMIT
APPLICATION
TYPE OF CONSTRUCTION
O Commercial/Multi-Family
❑ Demolition
❑ Manufactured Horne (SF or Duplex)
❑ Residential (SF, Duplex, or Townhome) 0 Reroof
INVOLVED PARTIES
Property Owner: OXY USA WTP LP
Mailing Address: 760 Horizon Drive, Suite 101, Grand Junction, CO 81506
Phone: ( 970 ) 263-3607
Contractor: DIAConstruction Phone: ( 970 283-5706
Mailing Address: 2171 West Interstate 70 Frontage Road, DeBeque, CO 81630
Architect: Heritage Building Systems Phone: ( 8fl0 643-5555
Mailing Address: 2612 Gribble Street, North Little Rock, AR 72114
Engineer: Heritage Building Systems Phone: ( 800 643-5555
Mailing Address: 2612 Gribble Street, North Little Rock, AR 72114
Manufactured Home Installer: Phone: (
Mailing Address:
PROJECT NAME AND LOCATION
Describe Work: Construction of a steel all-weather enclosure for existing motor, pump, and assocaited
equipment located on a permitted water impediment site.
Job Address: SESW Section 5, Township 7 South, Range 97 West, 6th PM
Assessor's Parcel Number: 2169-214-00-026 Sub. Lot Block
Owner's Valuation of Work: $10,000
Property Size (Sq.Ft or Acres):
Sq.Ft of Building: 1000 Height: 10 ft -14 ft # of Floors: 1
Class of Work: CI New 0 Alteration 0 Addition 0 Repair 0 Move/Relocation
Garage: 0 Attached 0 Detached
Septic: ❑ ISDS 0 Community
Type of Heat: 0 Natural Gas 0 Propane 0 Electric 0 Other
Driveway Permit: 0 Exempt 0 Permit #:
NOTICE
Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or
an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the
Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3)
another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a
State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of
the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
I hereby certify that I have read this Application and that the Information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of this Application, a Building Permit will be issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the
Building Division. In consideration of the issuance of the Building Permit, I agree that 1 and my agents will comply
with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS
regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit
may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s)
and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction
or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law.
Review of this Application, including submittals, and inspections of the work by the Building Division do not
constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the
Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations
rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or
builder.
I hereby acknowledge that 1 have read and understand the Notice and Certification above as well as
have provided the required information which_is correct and accurate to the best of my knowledge.
Katy Middleton 12/19/14
Property Owner Print and Sign
Date
OFFICIAL USE ONLY irlimWMIRMI
Spedal Conditions:
Adjusted Valuation:
z9, 990 ,°12-
Plan Check Fee:
227 /¢
Permit Fee:
4¢ / 75
Manu home Fee:
M/ Pt
Misc Fees:
Total Fees:Fees
'z8, B9
Paid:
411.-1_.g,
Balance Due:
6/i. o B
Jif.K4:
riW-qaa 1
ISDS No:
NO t A
Setbacks:
1"25, Rz5, 52
OCC Group:j
i ' -
Const Type:
Zoning: w
'(�`
BUILDING / PLANNING
DIVISION : 0
a !7°>
igned Approval Date
P11,-.8(
NOTE: If any required information is missing, delays in issuing the permit are to be expected. If
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The Permit Fee, as
well as any Septic or Road Impact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by a person having written authority from the
owner to act as their representative.
I hereby acknowledge I have read, understand, and will abide with the requirements of this
checklist.
Katy Middleton
Property Owner Print and Sign Date
12/19114
Garfield County
Community Development Department
108 8t' Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-countv.com
COMMERCIAL OR
MULTI -FAMILY
BUILDING PERMIT
APPLICATION CHECKLIST
COMMERCIAL OR MULTI -FAMILY BUILDING PERMIT APPLICATION CHECKLIST
In order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application.
• Parcel number obtained from the County Assessor's Office.
• Job address (assigned physical address).
• Legal Description: lot, block, filing, subdivision or tract, section, township and range.
• Owners name, mailing address, phone, fax, or cell.
• Contactors name, mailing address, phone, fax, or cell.
• Architect/Engineer's name, mailing address, phone, fax or cell.
• Building size, height, number of stories, lot size.
• Use of building (commercial)
• Class of Work (new, addition, alteration, repair, demo, move, other)
• Description of work.
• Type of heating (natural gas, propane, electric, other)
• Sewer system (Community or ISDS), also see other items below.
• Garage (attached or detached)
• Driveway permit (please see other items below)
• Valuation (labor and materials)
OTHER ITEMS:
• if you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. (Required to submit building permit application).
• ISDS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board.
• At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached at 970-625-8601.
• If you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
• If you belong to a Homeowners Association, it is your responsibility to obtain written approval, if
required.
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Projects with more than 10 occupants require plans sealed by a Colorado Licensed Design
Professional. Occupant load shall be calculated by IBC Table 1004.1.1.
• A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to
the local Fire District for review prior to permit issuance. All plans will be checked at the counter for
completeness. If any of the required information is missing, the building permit application cannot be
accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain, and easements.
• Provide setback distances from boundaries, buildings, septic, well, and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures include sheds, bams, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable)
• Retaining walls (engineer stamped detail required for walls over 4 ft, measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped, and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
COVER SHEET:
• Project identification.
• Project address and/or legal description.
• Design specifications to include building use and occupancy classification, type of construction,
building height and area calculations, occupant load, and fire sprinkler systems.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Design Professional stamped plans.
• Minimum 4 elevations (N,S,E,W)
• Floor plans for each level including dimensions and scale noted.
• Clearly label each room or space (office, storage, mechanical, elevator, etc).
• Wall types; clearly labeled and referenced. Identify all fire resistive wall construction.
• Construction details for all fire resistive elements referenced on floor plans and cross sections.
Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire
resistive listing number referenced on each assembly detail. (ex. UL P123)
• Window & door sizes, types, and operation and direction of swing noted on the floor plan.
• Specify roof slope/pitch, roof covering, and siding materials.
• Energy design specifications/details for R -values, U -factors, and SHGC's per IECC.
• Stair and guard details specifying rise, run, height and spacing.
• Accessibility; show compliance with accessibility requirements for all elements of the building per
IBC, Chapter 11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Engineered foundation design per soils report. Geotechnical report referenced.
• Design specifications to include roof and deck snow load, wind and seismic design, frost depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all
live/dead loads specified.
• Framing /connection details referenced on plans.
• Pre -manufactured structures require an engineers stamp, signature, and date.
MECHANICAL PLANS: Please provide the following information on the mechanical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Energy design calculations and details verifying compliance with the 2009 IECC.
• Floor plans for each level showing size, location and materials of all ductwork, plenums, return
and outside air intake registers.
• Size and location of all combustion air ductwork and openings.
• Size, type and termination of all gas appliance flues and vents.
• Location of all fire and combination smoke/fire dampers.
• Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc).
• Commercial kitchen hood location, hood and duct sizes, CFM calculations.
PLUMBING PLANS: Please provide the following information on the plumbing plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location.
• Water piping materials, length and size of pipe, water meter location, fixture unit demands,
location and type of backflow prevention devices.
• Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands.
• Additional piping plans for roof/deck drains, condensate, medical gas, etc.
• Plumbing fixture schedule for all plumbing equipment.
• Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc.
ELECTRICAL PLANS: Please provide the following information on the electrical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency
exit signs and lighting, and panel location.
• Diagram showing service entrance, conduit/wire size, main disconnect size, grounding
electrode/conductor size, feeder conduit/wire size, transformers and generators.
• Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc.
Building Plan Review
Description of Work: Steel pump building
Bin #:
Location Address: Sec05, TO7S, R97W
DEBEQUE, CO
General Information
Case Manager: David Bartholomew
Plan Case Number: BLDG -I2-14-8180
Parcel: 216921400026
Application Date: 12,2312014
Contacts
Owner: OXY USA WTP LP
Applicant: OXY USA VI? LP
Applicant Phone: Email:
Building
Planning/Zoning
Engineered Foundation Property Line Setbacks
Niro
Driveway Permit 30ft Stream Setbacks
Surveyed Site Plan f Flood Plain
Septic Permit and Setbacks / Building height
/ Grade/Topography 30% / Zoning Sign -off
N4
r -j
Attach Residential Plan Review List /)'4 Road Impact Fees
Minimum Application Questionnare _ HOAIDRC Approval
Subdivision Plat Notes Grade/Topography 40%
Fire Department Review Planning Issues
Valuation Determination/Fees Subdivision Plat
Red Line PlanslStampslSticker
Attach Conditions
A
General Comments:
allAril
Application Signed
Plan Reviewer To Sign Application / DoD fie 2. '9
Parcel/Schedule No.
40# Snowload Letter - Manu. Homes
Soils Report
Monday, January 12, 2015
OXY USA WTP LP
CONY 760 Horizon Drive, Suite 101
11111610/ Grand Junction, CO 81506
Pond 10 Vicinity Map
Revised: February 17, 2014 Garfield County, Colorado
D 0 8 1 6 2.4 3.2 4
Miles
ti -
H
ow -
210 21400026
OXY{USA INS
7,733.Acres
Pond 10
r
202 - KIMBALL GReeK RD
;:49f
>f
d i
7S 97W
LW 796-17C
491.'
Pond 10
Subject Parcel
(1 3 Mile Subject Parcel Buffer
Pond 10 Access Road
Oxy Responsible Road
Unimproved Public Road
Gravel Public Road
Paved Public Road
�1P l ��1�,i �i����!�1'i��r�ly's 1�1•i�,�l'�1'����I�,�t�1F�il kill i11
Receptiontt: 849874
QAr090011 11 06 28 AM Jean Plbaricu
1 n[ 7 Rec Fee EO 00 Oae r'ae 0 00 GARFIELD COUNTY CO
STATE OF COLORADO )
)ss
County of Garfield )
At a regular meeting of the Board of County Commissioners for Garfield County,
Colorado, held in the Commissioners' Meeting Room, Garfield County Administration Building
in Glenwood Springs on Monday, the 19" day of May A.D. 2014, there were present:
John Martin
Mike Samson
Tom Jankovsky
Frank Hutfless
Kelly Cave
Jean Alberico
Andrew Goraev
, Commissioner Chairman
, Commissioner
, Commissioner
, County Attorney
, Assistant County Attorney
, Clerk of the Board
, County Manager
when the following proceedings, among others were had and done, to -wit:
RESOLUTION NO. of O 1 q
A RESOLUTION OF APPROVAL FOR A LAND USE CHANGE PERMIT FOR A
WATER IMPOUNDMENT AND THREE STORAGE FACILITIES, ON A 7,732 ACRE
PROPERTY OWNED BY OXY USA WTP LP, LOCATED APPROXIMATELY 12
MILES NORTH OF DEBEQUE IN SECTION 5, TOWNSHIP 7 SOUTH, RANGE 97
WEST OF THE 6TH P.M., GARFIELD COUNTY
PARCEL NO# 2169-214-00-026
Recitals
A. The Board of County Commissioners of Garfield County, Colorado, "Board" received
a request for a Land Use Change Permit to allow for a Water Impoundment and three Storage
Facilities, as further described in Exhibit A, Site Plan.
B. The OXY USA WTP LP Water Impoundment and Storage Facilities are known as the
Pond 10 Centralized E & P Waste Management Facility is located on approximately 9.836 acres
within an overall 7,732.5 acre parcel of land owned by OXY USA WTP LP. The ownership of
this property is described in a deed found at Reception Number 759939 in the records of the
Garfield County Clerk and Recorder.
C. The subject property is located within unincorporated Garfield County in the Resource
Lands, Gentle Slopes and Lower Valley Floor zone district, approximately 12 miles north of
Debeque, Colorado accessed by private roads off of County Roads 204 and 213.
1
1111 Prwi11l1111!'1111,APIA Iv 116i 111I
Reception►* . 849874
06404:2014 11 06 28 PM Jean i116erieo
3 n' Ric Fee SO C: Doc Fee 0 00 GPRFIELD COUNTY CO
A. The forgoing Recitals are incorporated by this reference as part of the resolution.
B. The Land Use Change Permit for a Water Impoundment and Storage Facilities, also
known as the Pond 10 Centralized E & P Waste Management Facility is hereby approved
subject to compliance with the following conditions:
1. That all representations made by the Applicant in the application shall be
conditions of approval, unless specifically altered by the Board of
County Commissioners.
2. That the operation of the Pond 10 Water Impoundment and Storage
Facilities shall be done in accordance with all applicable Federal, State,
and local regulations governing the operation of this type of facility.
Conditions Prior to Issuance
3. The Applicant shall provide specifications on the netting to Colorado
Parks and Wildlife which verifies that waterfowl and birds are prevented
from entering the Water Impoundment. These specifications shall be
reviewed and accepted by Colorado Parks and Wildlife. Verification of
this acceptance shall be provided to the Garfield County Planning
Department prior to issuance of the Land Use Change Permit.
4. The surface area to be reseeded has been quantified as 1.63 acres. Prior
to issuance of the Land Use Change Permit, a revegetation security in
the amount of $4,075 shall be provided in a form recommended by the
Garfield County Vegetation Manager. The security shall be held by
Garfield County until vegetation has been successfully reestablished
according to the Reclamation Standards section in the Garfield County
Weed Management Plan (Resolution 2002-94, Section 4.06, 4.07 and
4.08).
5. Prior to issuance of the Land Use Change Permit, the Applicant shall
provide Garfield County Vegetation Management a soil management
plan that identifies any stockpiles that will sit exposed for a period of 90
days or more. This plan shall be reviewed and accepted by Garfield
County Vegetation Management.
6. Prior to issuance of the Land Use Change Permit, the Applicant's
contract wildlife and vegetation specialist, ERO, shall conduct a follow-
up site visit consistent with their recommendations in the report dated
March 20, 2014 to verify that no raptors or noxious weeds are identified
on the site.
3
1111 Nr DIVI.114,R lett H' i1h AIN
Reception#' 849874
06/04/2014 11 05 28 An Jean Alberi,o
4 of 7 Ree Fee SO 00 Doc Fee 0 00 GARFIELD COUNTY CO
Other Conditions
7. The Applicant shall provide documentation that the site remediation has
been completed to the satisfaction of the COGCC. This documentation
shall be provided to the Planning Department when such documents are
received from the COGCC.
8. The facility shall maintain compliance with CDPHE Storm Water
Management Permits, Drainage and Grading Plans, Reclamation and
Erosion Control Plans for the site.
9. Implementation of the Applicant's Dust Control Plan shall be required.
10. Compliance with all COGCC fencing, lining, leak detection, monitoring
well, and high level monitoring/alanns shall be required. Copies of the
COGCC Form 28 approvals shall be provided to the County upon
issuance by COGCC.
11. The facility shall maintain compliance with COGCC Noise
Standards/Regulations. If future compliance issues are identified the
Applicant shall provide noise mitigation in order to achieve compliance
along with a technical evaluation by a qualified professional to confirm
compliance.
12. The Applicant shall comply with all SPCC Plan provisions and shall
keep the plan current and updated for any changes to the facility.
13. The facility shall maintain compliance with Section 7-306 Lighting, with
all lighting to be directed inward and downward toward the interior of
the site. Facilities and storage tanks shall be painted a non -glare neutral
color to lessen any visual impacts.
14. The Emergency Response Plan provided with the Application submittal
including contact information shall be kept updated.
15. The Applicant shall comply with their Noxious Weed Management Plan
including the best management practices.
16. The Applicant shall comply with the recommendations of the ERO
Resources Biological Resource Report (dated March 20, 2014) included
in the Applicant's submittals and the Colorado Parks and Wildlife
recommendations contained in their referral letter dated April 24, 2014.
These conditions include:
4
1111 linAPIM+{ PrI4lM� �LIWRA'JI 1.114051R 111111
Receptions 849874
06/04,2014 11 06 29 Al Jean Alberioo
5 Of 7 Rec Fee SO 00 Doc Fee 0 00 GARFIELD COUNTY CO
a. Night lighting should be reduced to reduce disruption to
wildlife;
b. Any garbage containers shall be in locking and bear -proof;
c. Disturbed soils shall be reseeded and reclaimed as soon as
possible with a seed mix prescribed in the Oxy SPCC and in
accordance with the requirements of Garfield County
Vegetation Management;
d. All speed limits shall be posted, enforced and set at 25 mph or
less;
e. The netting on the pit shall be designed to prevent birds from
entering;
f. Colorado Parks and Wildlife shall be notified immediately if
any birds and/or wildlife are found dead or trapped within or
around the pit, netting or fencing;
g. The pit shall be constructed with a 4:1 escape ramp to allow
entrapped wildlife to escape;
h. Fencing around the pit shall consist of a minimum of a 7 -foot
chain-link fence capable of preventing elk and deer from
entering the pit; concurrently it should have a small mesh type
of fencing along the bottom of the fence (buried one -foot
below grade level and extending a minimum of two -feet above
grade) capable of preventing small animals from entering
between the gaps (gaps should be no larger than 3 -inches).
17. Storage areas shall be limited to the areas identified in the site plan and
limited to the use of Oxy USA WTP LP operations on the subject
property. The Storage Area identified as #3 shall only be utilized to
serve the Water Impoundment facility.
29
Dated this day of
ATTEST:
amt.. ry
rk of the Board
, A.D, 20 1 f- .
GARFIEL ' CO Y BOARD OF
COMMISS ONERS, GARFIELD
OUNT ` . OLO' . DO
5
■1111PJ1MMInl1t X1114:11,1 16141 11411 ti'i,11111
Reception#. 849874
0b104!2014 11 06 20 RM Joan R1berico
6 aI " Roc Fee 30 00 Doc Fee 0 00 GARFIELD COUNTY CO
Upon motion duly made and seconded the foregoing Resolution was adopted by the
following vote:
COMMISSIONER CHAIR JOHN F. MARTIN
COMMISSIONER MIKE SAMSON
COMMISSIONER TOM JANKOVSKY
, Aye
Aye
, Aye
STATE OF COLORADO
)ss
County of Garfield
I, , County Clerk and ex -officio Clerk of the Board of
County Commissioners, in and for the County and State aforesaid, do hereby certify that the
annexed and foregoing Resolution is truly copied from the Records of the Proceeding of the
Board of County Commissioners for said Garfield County, now in my office.
IN WITNESS WHEREOF, I have hereunto set my hand and affixed the seal of said
County, at Glenwood Springs, this day of , A.D. 20
County Clerk and ex -officio Clerk of the Board of County Commissioners
6
1111 11M15111 11,11.11.% IR, 1141vAli hliIAA 11 11 1
Recept,iona. 849874
06;;042,714. 11 06.20 FM Jean Riberico
ac Fee SO 00 Doe Fee 0 00 GARF
1.
_..r... ream MIMcO.•r
wwamrn s
IELO CO111tY CO
EXHIBIT A
SITE PLAN
w •.ra
ww1..0
I
rt
rri
MUM..
7,10
—
.1
1
'i—
rr.r.w...
.«w �....=i '_
1a+.lw.
11.010.1.�or rain
Storage Area 3 —
0.27 Acres (Water
Impoundment Use
Only)
1.r—.. -
Y.
7
1111 lntr,7141111 iii iihkE1.1 4111.1111. 911ii1,114►i, If 111
Reception#: 850337
06/17/2014 12 51 55 AM Jean Alberieo
1 of 5 Roo Fee:30,00 Doc Fae;0 DO GARFIELD COUNTY CO
LAND USE CHANGE PERMIT
for
A Parce! of Land Owned by OXY USA WTP LP Located Approximately 12 Miles
North of DeBeque in Section 5, Township 7 South, Range 97 West of the 6"
P.M. and Legally Described in a Deed found at Reception Number 759939 in
the records of the Garfield County Clerk and Recorder with a project area of
approximately 9.835 acres
(Assessor's Parce! No. 2169-214-00-026)
In accordance with and pursuant to provisions of the Garfield County Land Use and
Development Code, as amended, and Resolution No. 2014-28 of the Board of County
Commissioners of Garfield County, State of Colorado, the following activity is hereby
authorized by Land Use Change Permit:
Water Impoundment and Three (3) Storage Facilities known as the Pond 10
Centralized E&P Waste Management Facility as shown on the Site Plan
Attached as Exhibit "A" (UPA —7864)
This Land Use Change Permit — Limited Impact Review is issued subject to the
conditions contained in Resolution No. 2014-28 and set forth in Exhibit °B° and shall be
valid only during compliance with such conditions and other applicable provisions of the
Garfield County Land Use and Development Code, as amended, Building Code, and
other regulations of the Board of County Commissioners of Garfield County, Colorado.
ATTEST:
':. m
rk of the Board
COUNTY BOARD OF
MMISSIONERS,
OUNTY, COLORADO
1111 11 11 1
Receptian#: 350337
06/17/2014 12;51:65 PM Jean Rlbericc
2 of 5 Rae Fea:$0.00 Dae Fee 0.00 GRRFIELD COUNTY CO
Exhibit A
(Project Site Plan)
L
M...... INC •fR•••• .I...
NO now
[ �1
emirs
1111~ A
www AN.
y
Storage Area 1-
0.66 Acres
.110•1.+4.9
..•0046.1.sr
... ••w...
--- �-mow -
Storage Area 3 —
0.27Acres (Water
Impoundment Use
Only)
1111 NFarnaiw.i tVilfhilliZilla 11111
Recepptlent#' 850337
0611717014 12:51:55 P11 Jean Rlbarico
3 of 5 Roc Fee:SO.00 Doc Fee:0.00 GARFIELD COUNTY CO
Exhibit B
(page 1 of 3)
Conditions of Approval
1. That all representations made by the Applicant in the application shall be
conditions of approval, unless specifically altered by the Board of
County Commissioners.
2. That the operation of the Pond 10 Water Impoundment and Storage
Facilities shall be done in accordance with all applicable Federal, State,
and local regulations governing the operation of this type of facility.
Conditions Prior to Issuance
3. The Applicant shall provide specifications on the netting to Colorado
Parks and Wildlife which verifies that waterfowl and birds are prevented
from entering the Water Impoundment. These specifications shall be
reviewed and accepted by Colorado Parks and Wildlife. Verification of
this acceptance shall be provided to the Garfield County Planning
Department prior to issuance of the Land Use Change Permit.
4. The surface area to be reseeded has been quantified as 1.63 acres. Prior
to issuance of the Land Use Change Permit, a revegetation security in
the amount of $4,075 shall be provided in a form recommended by the
Garfield County Vegetation Manager. The security shall be held by
Garfield County until vegetation has been successfully reestablished
according to the Reclamation Standards section in the Garfield County
Weed Management Plan (Resolution 2002-94, Section 4.06, 4.07 and
4.08).
5. Prior to issuance of the Land Use Change Permit, the Applicant shall
provide Garfield County Vegetation Management a soil management
plan that identifies any stockpiles that will sit exposed for a period of 90
days or more. This plan shall be reviewed and accepted by Garfield
County Vegetation Management.
6. Prior to issuance of the Land Use Change Permit, -the Applicant's
contract wildlife and vegetation specialist, ERO, shall conduct a follow-
up
ollowup site visit consistent with their recommendations in the report dated
March 20, 2014 to verify that no raptors or noxious weeds are identified
on the site.
Other Conditions
7. The Applicant shall provide documentation that the site remediation has
been completed to the satisfaction of the COGCC. This documentation
1111 �1r1,1�����I�I��. ti� 1N��lsi�1'fai+� ��1�1G.���1ti r1Yf 11111
Reoept i an# : 850337
06/1712014 12:51:55 PM Jean R1berlcm
4 o1 5 Rem Fee -$0 0a Doo Fee :0.00 GARFIELD COUNTY CO
Exhibit B
(page 2 of 3)
shall be provided to the Planning Department when such documents are
received from the COGCC.
8. The facility shall maintain compliance with CDPHE Storm Water
Management Permits, Drainage and Grading Plans, Reclamation and
Erosion Control Plans for the site.
9. Implementation of the Applicant's Dust Control Plan shall be required.
10. Compliance with all COGCC fencing, lining, leak detection, monitoring
well, and high level monitoring/alarms shall be required. Copies of the
COGCC Form 28 approvals shall be provided to the County upon
issuance by COGCC.
11. The facility shall maintain compliance with COGCC Noise
Standards/Regulations. If future compliance issues are identified the
Applicant shall provide noise mitigation in order to achieve compliance
along with a technical evaluation by a qualified professional to confirm
compliance.
12. The Applicant shall comply with all SPCC Plan provisions and shall
keep the plan current and updated for any changes to the facility.
13. The facility shall maintain compliance with Section 7-306 Lighting, with
all lighting to be directed inward and downward toward the interior of
the site. Facilities and storage tanks shall be painted a non -glare neutral
color to lessen any visual impacts.
14. The Emergency Response Plan provided with the Application submittal
including contact information shall be kept updated.
15. The Applicant shall comply with their Noxious Weed Management Plan
including the best management practices.
16. The Applicant shall comply with the recommendations of the ERO
Resources Biological Resource Report (dated March 20, 2014) included
in the Applicant's submittals and the Colorado Parks and Wildlife
recommendations contained in their referral letter dated April 24, 2014.
These conditions include:
a. Night lighting should be reduced to reduce disruption to
wildlife;
b. Any garbage containers shall be in locking and bear -proof;
c. Disturbed soils shall be reseeded and reclaimed as soon as
possible with a seed mix prescribed in the Oxy SPCC and in
accordance with the requirements of Garfield County
Rees tion#: 850337
0511712014 12:51:55 PM Joan Albertoo
5 o1 5 Roe Fee:$0.00 Doc Foor0.00 GARFIELD COUNTY CO
Exhibit B
(page 3 of 3)
Vegetation Management;
d. All speed limits shall be posted, enforced and set at 25 mph or
less;
e. The netting on the pit shall be designed to prevent birds from
entering;
f. Colorado Parks and Wildlife shall be notified immediately if
any birds and/or wildlife are found dead or trapped within or
around the pit, netting or fencing;
g. The pit shall be constructed with a 4:1 escape ramp to allow
entrapped wildlife to escape;
h. Fencing around the pit shall consist of a minimum of a 7 -foot
chain-link fence capable of preventing elk and deer from
entering the pit; concurrently it should have a small mesh type
of fencing along the bottom of the fence (buried one -foot
below grade level and extending a minimum of two -feet above
grade) capable of preventing small animals from entering
between the gaps (gaps should be no larger than 3 -inches).
17. Storage areas shall be limited to the areas identified in the site plan and
limited to the use of Oxy USA WTP LP operations on the subject
property. The Storage Area identified as #3 shall only be utilized to
serve the Water Impoundment facility.