HomeMy WebLinkAboutEngineer's Reportderson Structural ngineering January 11, 2015 Ms. Kathleen Kopf 280 EIk Run Road New Castle, CO. 81647 RE: Bathroom Addition — 280 EIk Run Road Dear Ms. Kopf: Regarding the subject Bathroom Addition, Anderson Structural Engineering has received the original structural design drawings and sketches provided by you for the scope of work. Furthermore, we visited the site on January 10, 2015 to inspect the completed work. The residential building is a two story wood framed structure built in 1998. The second story addition consists of non bearing partition walls to enclose a bathroom facility. Finishes were complete and no structure was visible at the time of the inspection. We understand that no structural modifications to the original framing were performed. Design drawings indicate the second floor framing to consist of 9 )4" TJI- 150 series joists at 16" o.c. with mid span blocking. Joist spans in the area of the addition are approximately 12'-0" measured from the exterior 2 x 6 stud bearing wall to a center 83/," x 18" glulam beam. We understand that floor performance has been satisfactory to the owner. Based on the design drawings and the as built loading conditions, we find the existing framing in compliance with current International Building Code 2009 requirements for strength and serviceability. Please do not hesitate to call our office for any additional questions. Sincerely, andon A iderson, P.E. Anderson Structural Engineering, Inc. 448 EIk Run Road • New Castle, CO 81647 (970) 984-0320 • email: Landon@anderson-structural.com