Loading...
HomeMy WebLinkAboutElevator Inspection ReportDEPARTMENT OF LABOR AND EMPLOYMENT Division of Oil and Public Safety Conveyance Section (303) 318-8550 Fax (303) 318-8534 Hydraulic Elevator Safety Test Report Power Down Static Test Relief Valve Facility/General Information Building Name: �d f VA.?' C l• tti�! 5 Manufacturer f)01 f<. Capacity: 2.5 -co Address 7 -7(7 /or_)►r i -v re 7 IA --State Reg # Job/Contract#: £ '6fsT5 CitYC. r"f C U f Date: / rf 3 Z Dutyt:.- assen er Freight 1 g Zip. `3I 6 3 5 Rated Speed: / 60 ___tri Freight Loading Class: Cl C2 C3 Circle One 1 Acceptance ategL�r ory 1 Tests 2 Category 1 and 5 Witnessed Testing Date Tests Performed: 2. r 20/i r'( Was Inspector Present Yes to If "Yes" Inspector Must Sign Test Report Piston Diameter: 4,1'' in Relief Valve to be set at 150% or less of the Working Pressure Adjustment Needed Yes rtro No Load Working PSI: / '/} psi Adj ; stments Sealed- (AID No Full Load Working PSI psi Relief Valve Setting psi Test Tag Installed. es_ No 2 Plunger Gripper Operational:1( Yes No 2 Overspeed Valve operational. C0 Yes No Time Started / Q E/ 5 Proper Fuses Installed, - es, No Connections Tight ,r°Yesti No Time Ended: / / O 0 Controller Clean des- No Jumpers Removed .,ire- - No Elapsed Time / ti PI/ 11 Relay(s) V.sually Inspected No Change In Car Position. Yes 1Vo) If "yes" Distance in Oil Loss Accounted For.. -'Yes ;' No NOTE: If any oil loss can not be accounted for, the elevator must be removed from service and the Authority Having Jurisdiction must be notified. Safety Devices Stop Switches: In Car ,955: Fail Pit: evo31 Fail Top Of Car t ss Fail Directional Limits Up. -A Fail Down .P570 Fail Low Oil Protection NA ass Fail Final Limits: Up: Pass Fail Down Pass Fail Escape Hatch Contact NA Pass Fail Low Oil Pressure Switch;. N'9, uass Fail Car Door Restrictor: (Pass Fail E 0 Closing Force (Max 3010) ibf Safety Edge. (Pass Fail Door Guides Secure (14;DFail Closing Time sec Electronic Edge: ,rl a s- Fail Door Interlocks/Gate Switch. salass Fail Emergency Operation Phase I Recall NA a ass j Fail Phase I Fire Service Instruction Signage In Place es No Phase II Operation NA .--Pg-s) Fail Phase 11 Fire Service Instruction Signage In Place. Yes 07) Emergency Communication. NA (14;13) Fail Alarm Bell Pass Emergency Lights: Passe -Fir , ,Fail - T Standby or Emergency Power Operation' /171.-D Fa I /171.-D Signatures Logs Logs Properly Maintained / f?' No Logs Updated with this Annual safety test. ; Yes No Fire service logs maintained. Yes No I certify all statements are true to the best of my knowledge and that all testing was performed according to The Elevator and Escalator Certification Act CRS § 9-5 5. Conveyance Regulations 7 CCR 1101-8 and adopted Codes: Mechanic Name . :/::::( �, /-//j/ / Company Name 7-&-e Signature y Date Z J jf e.0 J f �} State License #: 6.6 ' O(}c) '] 3 0 Inspector Name Company Name Signature Date State License # Required to be performed during acceptance inspections Required to be performed during acceptance and Category 1 and 5 witnessed inspections I=.,.ued 12Jan12