Loading...
HomeMy WebLinkAboutApplication-PermitI N. 0. 10462 Garfield County . Building & Sanitation Department 108 81h Street, Suite #401 Glenwood Springs, Co. 81601 Office-945-8212 Inspection Line-384-5003 JobAddress -:;(; Q~(il{ o1 ( o( I ctV\ol LCSD f Nature of Work_-E.Bl!!uil!!ld'!!!in"'-gLPe!i!.rm!!.!!±-it ~:J.~s--'-q_..~.5_-Lt9!..!.' l_c-O::.ic-_.:::O:.:.i '~------ Use of Building S/ f IJ..j{:~l (X'te W/et1t Q!/IJvtJ/c C)Utzarye f tJf/.cOI!f;;;;;- Owner \X)\ Vtu.Q J H:td .1-QwuJtce f Contractor l-ie~((\~ Co~ Bul\cletS Amount of Permit$ "331-:S .1-l:-Date 5~3-01- Clerk jfrjJ[o L GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8'" Street, Suite 401, Glenwood Springs, CO 81601 Ph~ 970·945-8212 I Fax: 970-384·3470 I Inspection Line: 970-384·5003 IOYb. Parcel/Schedule No) 3 9,) ~lq l-03 -0 I\,. A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID JF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHLN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A NOT PRESUME TO GIVE AUTHORITY TO VIOLATE ANY OTHER STATE OR LOCAL CONSTRUCTION OR THE PERFORMANCE p:;>k-e.f AGREEMENT QlJ.jJ/k g"{(,):!-; Carport: 0 Site Plan Adjusted Valuations: Lie. Lie. No. Q Q Single Double PERMISSION IS HEREBY GRANTED TO THE APPLlCANT AS OWNER, CONTRACTOR AND/OR T1-IE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSID.ERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN LN·30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER Wl·IEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF S:UBMITIED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLJTIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER COMMENTS ARE INTENDED TO BE CONSERVATIVE AND lN SUPPORT OF THE OWNERS LNTEREST. Dl u VI J re~EBY ACKNOWLEDGE TI\d'c\:f:>EAD AND UNDERSTAND THE AGREEMENT ABOVE !INITIAL)' IDe.., LH,t~o+, ~2--:s-o:t- ('t: GIO~Lf c~ qo1~ fd JJ> 17:01 ."3Lj $~·=sv--J.GJ3 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constmcted to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made npon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued nntil all tbe required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. 9. If you will be connecting to a public water and/or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTIFICATE OF OCCUPANCY MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupanc~~ IJL'~nd the issuance of a Certificate of Occupancy for the dwelling under building permit # _.l_,v-"-'t-"~--'-- (:)•7V Sign~~e BpajJplicationoctober2006 l ~I Date VALUATION/FEE DETERMINATION Applicant \bl 1 ,.J c;, o Subdivision '"P\-'6-~ -G.\oe~ Address. __________ _ Lot/Block Lc>> '-'.:l \) 1 \., Date_~'-1.;\ ~2.L:i3c.:-:£OL:..:JL-____ _ Contractor Finished (Livable Area): Main 3/b7 Upper 7 ":>"") Lower Other Total Square Feet 3'11 fS x.. 7 q 1.11"" Valuation d-<=t2,51l. 'Z'f Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: . /{,.)( 1\ \~ 13 "'~2°"' V aluatwn -i -> Crawl Space: Decks/Patios: Covered I 2-X. 7 'J Valuation ' = n 2.&-CJ" Open Valuation 3'11 X lc Total Valuation PLAN REVIEW CHECKLIST Applicant 'VJ 1 1-J U. a Building dEngineered Foundation --lL._Driveway Permit JB.<e--.fr _Lsurveyed Site Plan ___L_Septic Permit and Setbacks Get-J~ L Gradeffopography 30% _/Attach Residential Plan Review List ~Minimum Application Questionnaire Lsubdivision Plat Notes +Fire Department Review -t al nation Determination/Fees Red Line Plans/Stamps/Sticker _0ttach Conditions dApplication Signed _LPlan Reviewer To Sign Application ~reel/Schedule No. ~0# Snow load Letter-Manf. Hms. \,/ Soils Report GENERAL NOTES: Planning/Zoni __ Property ine Setbacks __ 30ft S earn Setbacks __ Flo a Plain __ B ilding Height ning Sign-off oad Impact Fees OA/DRC Approval. __ 1~rade/Topography 40% -L.\rlPlanning Issues __ Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a pem1it application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with 1 decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the 9JYelope. Yes._.,/'--- 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks d9-3pply. Yes---'/=---- 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent pr9perties ), streams or water courses? Yes._""V:__ __ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 ~ Yes. ____ _ 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Departm.nent atfl5-8601. Yes---''""~"'------- 6, Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes.~ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces angJhe clearances required between wood and earth? Yes . ....::.~----- 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes~ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wi.J}rlloads? Yes.__.,~:::_ ___ _ 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof . ? constructlO~- Yes._::.._.......--____ _ 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes .....--------· 12. · Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes~· 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes.~"'---......,--- 14. Does the plan include any stove or zero clearance fireplace plrumed for installation including 3 15. 16. 17. 18. 19. 20. 21. 22. 23. make and model and Colorado P? II certifications or phase II EPA certification? Yes No __ k~~~~-----~ Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? ~ Yes No __ ~~~--------- Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes ~ No ___________ __ Does the plan include a window schedule or other verification that windows provide natural light and 'Yll<ilation for all habitable rooms? Yes / No __________ _ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for thes.e areas? Yes No~~~-------- Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes.____.-No _____ _ Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes _.....---No -------- Do you understand that if you belong to a ijomeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantialJllOdification of the plans. Yes ~ No _________ _ Will this be the only residential structure on the parcel? Yes ~ No Ifno-Explain: _______ __ Have two (2lcomplete sets of construction drawings been submitted with the application? Yes_-"._._/'----- 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? / Yes ~ No ________ __ 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes ~ No ________ __ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zo~district? Yes ~ No ___________ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by__.the Garfield County Building Department? Yes ~ No _________ _ 28. Do you understand that approval for design and/or construction changes are required prior to the appliS!Ji<>nofthese changes? Yes ~ No ____ _ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building pej!Rit? Yes / No ___ ~- 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes ~· No ____ -:-_ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50;90 re-inspection fee? Yes ~ No ____ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy oj:the building? Yes / No __ ~--- 5 33. 34. 35. 36. 37. 38. Si Are you aware that the Permit Application must be signed by the Owner or a written authoritY7eing giv for an Agent and that the party responsible for the project must comply with the IRC? Yes No ___________ _ Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time,.of applicable inspection. Yes ~ No _____ _ Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a buildingyermit application? Your attention in this is appreciated. Yes ~ No. ________ _ Do you know that the local fire distijctmay require you to submit plans for their review of fire safety issues? Yes ~ No (please check with the building department about this requirement) Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? . Yes.~· Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a _.Certificate of Occupancy? Yes~.""~--- y acknowledge that I have read, understand and answered these questions to the f my ability. ner Date ~?1J.t"':::::>2:...1.:.~~~~--·( days); -~3e:__7:_~:::£_~_,7:_C.~t-'7 ___ .( evenings) Project Name: /_,J 1 ..:J 7 u R -e..s 1.0 <--L... Project Address: W, '? I(. -A.>f< . .o ~ l..<e.:i Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone(970)945-8212 Job located at ~Ad kyz Permit No. /0£6:;2 I have this day inspected this structure and these premises and found the following corrections needed: 1) c,;./d 13~ ~~ ~~~ ~~-ir oZ)acU'$~ ~~u~ ~ ~ cf7L kc:. /)V'Ao/~ ,d;rAuf'../A-· . c£4f!V~--r . 4lk:.A4~~~~ 4/A~~~~~ 1)J r~/~~ g~7~ ~ ~/1Sf$~o~~ JJ~.~~omcti!.'~O:t?!.ted before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /e:P·t). .c 7 20/)_C~-- Building Inspector ~~ Phone (970) 945-8212 COUNTY OF GARFIELD • BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at @8¥ ~~ Permit No. 1o .tf<S?- I have this day inspected this structure and these premises and found the following corrections needed: ~~~ for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date OJ... I s..O$? 20 Building Inspector ~~:::;;?~cc::::>~.c=--- Phone (970) 945-8212 ~ No. \CJL\b), Assessor's Parcel No. d-~C\j-·\C\\-03-0\£ Date S-d-~-<J'+ ~~l ;}_ ·J;).·Og~ BUILDING PERMIT CARD Job Address ~wl!i?O;< 8 i · .. ~ ./mv< t\~feVIG\tN1 lo-T w?\b Owner \>vAg a liw.L t O:wts:hce Address Phone # ___ _ Contractor \vl~ \Atf OoS}QVV\ (3 mlclf'G AddressQ'tf vntcH(tiJ\Q Lo() \? Phone # Q(.J$<S8lP Setbacks: Frort R~a.r RH LH Zoning ___ _ :SJ F wrcrouJ -spcu:e. w 1 a ub. q_omt~f.'. J-utRua. p:mo lffSP'ECTIONS Soils Test-::---,.--------- Footing 6 -tf·o 7 ~ Foundation 6·7-o"'l~ Grout _________________ _ Underground Plumbing ----------- Rough Plumbing tCl·/&J·P7~ Framing /O.,Jl::127~ Insulation~ j;.fi~Q?C2 !;>[/ Roofing_£--::--::=--::-:::--......:{)~­ Drywall Jl-p.-o7~ Gas Piping /t:fl'/tZtL? fiW?= Weatherproofing _______ -;o------ Mechanical / Electrical Rough (State) ---·"':-v-T-/_· _______ _ Electrical Final (State) V / ~ ~inal <J~c:zo-o<;; /Checklist..,gQ_roo.L.eted? 17 Certificate Occupap_cy ~.., ~ ""' Date d::!-~-0":1-)~'S\) Septic System *--'--==---------- Date .-- Final ____________ _ Other--------------- NOTES (continue on back) INSPECTION WILL NOT BE MADE UNlESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE RIEQI[JIIREJI> FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued ••• J>.::-£.~:?.J: ..... Zoned Area .•.••••••••.••••••••..••••••.•• Permit No ••• .lQ~~~················ AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. ...,...,-. use ;;jf l.\{/arw :pace rPjtiRlfohEel (')l'l\>b\e ~f9!:i~ k UJ\t.DV· pol\.'0 Address or Legal Description "'f&tr -215 :I r(\ I D L<>..:>IJ Loop Owner hliWJO ZinEL i Caw:t\ce Contractor l-\c.. '{.o."\ Cti\eWI Sethaeks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Il\llspections Cali 384-50~)3 108 8th Street Glenwood Springs, Colomdo API?ROVEDDO NOT DESTROY THIS CARD Date $j,'3-d+ By Kla~/ Jb IF PLACED OUTSIDf-COVli!R WITH CLEAR PLASTIC Parcel Detail Page I of 3 Garfield County Assessor/Treasurer Parcel Detail Information Asse~$9IIIB2!l§!Jrl'TPmpenySeilrch I Assessor Subset Query I As_sf_ss9LS1lles_Search Clerk & RecmderJSJ'ceptionSei!Lch Parcel Detail I Yaiue Detail Sales Deta,il I Residential/Commercial Improvement Detail Land Detail I Photographs I Tax Area II Account Number II Parcel Number II Mill Levy I I 082 II R820107 II 239319103016 II 67.224 I Owner Name and Mailing Address IWJNGO, EARLE L & CANDACE L I IPOBOX2405 I IBASALT, CO 81621 I Legal Description lsECT,TWN,RNG:19-7-88 SUB:ASPEN GLEN I IFILING 3 LOT:WP16 PRE:R820001 I IBK:0966 PG:0686 BK:0925 PG:0345 I IBK:0918 PG:0408 BK:0904 PG:0724 I IBK:0887 PG:0824 BK:0849 PG:0695 I IBK:0846 PG:0615 BK:0835 PG:0305 I IBK:0703 PG:0121 BK:1813 PG:l15 I IRECPT:700628 BK:1214 PG:597 I IRECPT:571460 BK:0921 PG:0661 I Location I Physical Address: 11284 MIDLAND LOOP CARBONDALE! I Subdivision: JIASPEN GLEN FILING 3 I I Land Acres: 110.577 I I Land 89 Ft: llo II II http://www .garcoact.cornlassessor/parcel.asp ?Parce1Number=2393191 03016 4117/2007 Parcel Detail Page 2 of3 lii==~Se~:~~ion~===l~~~ =T~o~w;~sh~ip~=:!!=l =~R;;;;~~~g;;:;,e ==ill Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 240,oooll 69,6001 I Improvements: II oil ol I Total: II 240,00011 69,6001 Sale Date: 116/20/2006 Sale Price: 11200,000 Basic Building Characteristics Number of Residential lo I Buildings: Number of Commllnd Jo I Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type II Amount I I 2006 II Tax Payment: Whole II ($4,678.80)1 I 2006 II Tax Amount II $4,678.80/ I 2005 II Tax Payment: Whole II ($4,699.32)1 I 2005 II Tax Amount II $4,699.321 I 2004 II Tax Payment: Whole II ($5,619.20)1 I 2004 I Tax Amount II $5,619.201 I 2003 Tax Payment: Second Half II ($2,390.58)1 I 2003 Tax Payment: First Half II ($2,390.58)1 I 2003 I Tax Amount II $4,781.161 I 2002 II Tax Payment: Whole II ($4,799.36)1 I 2002 II Tax Amount II $4,799.361 I 2001 II Interest Payment II ($45.99)1 I 2001 II Interest Charge II $45.991 I 2001 II Tax Payment: Second Half II ($2,299.65)1 I 2001 II Interest Payment II ($23.00)1 II II http://www .garcoact.cornlassessor/parcel.asp ?Parce1Number=2393191 03016 4/17/2007 Parcel Detail I 2001 Interest Charge II $23.ool I 2001 Tax Payment: First Half II ($2,299.65)1 I 2001 Tax Amount I $4,599.30 I 2000 Interest Payment I ($167.55) I 2000 Interest Charge II $167.551 I 2000 Tax Payment: Whole II ($5,584.92)1 I 2000 I Tax Amount II $5,584.921 I 1999 II Tax Payment: Whole II ($5,397 .02)1 I 1999 II Tax Amount II $5,397.021 TopofPage Assessor Datab<t~e Search Options I Treii§]Jrer Database Search Options Clerk & Recorder Database Search Options Page 3 of3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accnrate data. However, Good Turns Software and the Garfield Connty Assessor and Treasurer's Offices are nnable to warrant any of the information herein contained. Copyright © 2005 -2006 Good Turns Software. All Rights Reserved. Database & Web Design by Q_o_od Turns Softwaxe. http://www .garcoact.com/assessor/parcel.asp?Parce1Number=2393191 03016 4/17/2007