Loading...
HomeMy WebLinkAboutApplication-PermitGarfield County L.../ N_o_._Io_47_4 ___ __J Building & Sanitation Department 108 8111 Street, Suite #401 Glenwood Springs, Co. 81601 Office-945-8212 · Inspection Line-384-5003 JobAddress Q(J l'YLO'S\tlfj l\l8 furoc\1\UE Nature of Work Building Permit ~L!(11-"3"31-();)-\D ~ Use of Building C6LcJ 'ffi'@ t(3 ~ IJ\.01.) ((: owner fbsacnVifi C0!lvY\\MefCLUl Contractor OWV'tff' ;:slor :PY"ec~ Amount of Permit $ Brl.\ -~ Date_'S.=..,-;N~e-·Q_i:\-_. __ _ clerk._~""-'('--.Cy-+-lu_~f_' __ _ I GARFI ELD COUNTY BUILDING PERMIT APPL I CATI ON 108 8'" Str ee t, Suite 401 , Gl enwood Springs, CO 81 60 1 Perm it No: raJj:q0·9 45 -8212 1 Fax: 970-384-34:~c::~:::::nu~~n~~~;o~;:;; I O~OOdv I Job Add ress : qq ~\-.w, ~ Pttm. Co $?l <o 35 1 Block No : Lot No: f (} e S ubd . 1 ExlJ;uon : te14<.Ac.a-s ~-,IAL ~S S ubcL 2 +t~~r;J ~~~~~( Addre ss Phs 4-_ 4: _4-WkPh: ~ ;)..5)..o S. G ~~~t~ /o . ':> ') ') 3 ~t~c~~ Ad dr ess: R.-~ p~ -'8'1 51. 7 (p Li e . No . L ~O C-Vt'Z~\ 4 Ar chite ct/Engineer : 0 -31 ~l'i_L~ Address: -~ ~~ Jb 5" ;; l Ph: b l/JOE;f[O Li e. No . 5 Sq . Ft. of f9il~nl} Sq. Ft . of Lo t: Height:zo ~ No . of Flo ors: C/)00 { 0 Us e of Buildingtol J ~~e-f (J..)o.-~ l 7 De scribe Wo~ • \-/./ r'<C.¥1~ eo ~ ~ ._t..,ll .... .:<:. ~ eo~ ~·L--- b Class o f Work: ~ New 0 Alte ration o Remove 0 Addi ti on :J Mov e 9 Garage: 0 Single Carport: 0 Single [J Double ...-::J Do u ble 10 0 Driveway Permit [J On -Site Sewage ~ Site Pla n Disposa l ll Valuation of Work : $ ~ 'f t;O (_) Adju sted Valuatlons :f; f) fo 1 5/o 9, ~ 12 S p ec ia l Conditions : I NOTICE I P l a n c s~l l~e~ 1 Permit F e e: A SEPARATE ELECTRICAL PERMIT I S REQUIRED AN D M UST BE &-3 2-"l<t' I SSUED BY THE STAT E Or COLORADO. T HIS PERMIT BECOMES NULL AND VOID W WORK OR CONSTRUCTION I Tota l Fee: D ated P e rmit I ssued : AUTHORI ZED I S NOT COM MENCE D WITHLN 18 0 D AYS. O R. If' ol.( CON STRUCTI ON OR WORK I S SUSPENDED OR ABANDON ED FOR A J 31lf PE RI O D OF 18 0 DAYS AT ANY TI ME AFTER WORK I S COMMENCED. 1 HEREBY C ERTIFY THAT I HAVE READ AND E XAMINED T HIS O CC Gro up: C o nst. Type: APPLI CATION AND KN OW TH E SAME TO BE TRUE AND CORRECf. ALL s --( JZB PROVISI ONS OF LAWS GOVERNI NG TH I S TYPE O F WO RK \\~LL B E I COMPLETED WITHIN W HETH ER SPECI FI ED H ERE I N OR NOT. T H E Z onin g : Se t b acks: GRANTING OF A PE RMIT DOE S NOT PRESUME TO GNE AUTHORITY TO VIOLATE OR CAN CEL TH E PROVI SIONS OF ANY OTHER STATE OR LOCAL LAW REGULAT ING CONSTRUCTI ON OR T H E PERFORMANC E OF CON~~ fq_ ~ M a n u. H om e: ISDS No . & Fee: SIGNATURE OF OWNER ( V 1DAT E Lf~\ A..l \ ~\U ~-10 -~.~~ ~·,~5/d. 4/07 ~ 8-~l-0~ :~O~ATE PLNG. DEFT. I ~lS'O -, APPROVAL/DATE A GREEMENT PE RM I SSI ON I S H EREBY GRM'TED TO TH E AP PLICANT AS OWNER CONTRACTOR AN D /OR THE A GEI\'T OF THE CONTRACTOR OR OWN E R TO CONSTRUCT THE STRUCT URE AS DETAILED O N PLANS AND SPEC IFICATIONS SUB MITTE D T O AND REVIEWED BY THE BUILDING DEPARTMEI\'T. IN CONSIDERAT I ON OF THE I SSSUAN CE OF THI S PERMIT. THE SIGNER. H EREBY A GREE S TO COM PLY WlTH ALL B UILD ING CODES AND LAND USE REGULATIONS ADOPTED BY GARFI ELD COUNW PURS UANT TO A liTHORITY GNEN LN 3 0 .28.201 CRS AS AME ND ED. THE SI GN ER FURTHER AGREES THAT I F T HE ABOVE SAID ORDIN ANCE S ARE NOT FULLY COMPILED W ITH IN T HE LCOATI ON. ERECTI ON. CO NSTRUCTION. AND USE Or THE . ABOVE DESCRIBE D STRUCTURE . THE PERMIT MAY BE REVOK ED BY NOTICE FROM T HE COUNW AND THAT THEN AN D T HERE I T SHALL B ECOME NULL AN D VOID. THE I SSUANCE OF A PERMT BASED UPON PLANS. SPECIFICATIONS AN D OTHER DAT A SHAI..L NOT PREVENT TH E B UI LDING Of'f'l C!AL FROM TH EREAFTER REQUIRING T HE CORRECT I ON OF ERRORS I N SAID PLAN S. SPECIFICAT I ONS AN D OTHER DATA OR FRO M PR EVE NTING BU ILDI NG OPERATION B EING CARRI ED ON THEREUNDER WHEN I N V I OLAT I ON OF T HS CODE OR ANY OTHER O RDINANCE OR REGULAT I ON OF THIS JURI SD ICTION. THE REVI EW O r SUBMITTE D PLANS AN D SPEC IFICAT I ONS AND INSPECTI O NS CONDUCTED T HEREAFTER DOES NOT CO NS llT UT E AN A CCEPTANCE OF ANY RESPONSIBILITIE S OR LlABLlT I E S BY GARFIELD COUNTY rOR ERRO RS. OMI SS IONS OR D I SCREPENC I ES. TH E RESPONSI BILITY FOR THESE ITEMS AND I MPLEMENTAT I ON DU RIN G CONSTRUCTION RESTS SPECIF!ClALLY WITH T H E ARTICTECT. DESIGNER. BUILDER. AN D OWN ER. CO MMENTS ARE I NTENDED TO BE CO NSERVATN E AND I N SUPPORT OF THE OWNERS LNTEREST. tr ~~Fee I~~=~ ACKNO~E~~l~vg.rY\· AD AND UNDERSTAND TilE AGRECM. E~ IINITIAC. ~ $"~) • jt{ (!) ~ 2-z,q~ . S"' ~hliJ.'-1-v / r .::::::::::::::::~ ... IJ./lRF'!El,D OOUNTI' BUILPINO PE!\M!'l' API'L!CA'l'!ON l08 8"'' StfHt. ~ 401, GtK,.,od &prl»p. CO 81101 PlloM: gt-O.pf.G-8212 I J'Ui 970·38'-'9470 I lDll~lltlo-.11, lAftlt 971).384-6003 PAGE 01/02 PenmtNo: -1!------Fw:cd/Scb•dlllel'lo l4'iJC13} !iflO'rl,h 'Co '?lb35 ASEMl'ATE rs.~uso JJY THE «rA1E AIJlWtM~NT .t~ .. ,....,.,., AI'F'T"'CA!I'l' M OWNER. C<l>mw;!OR AND/OR THll AGJM' oF 'IRE COIITRI\CTO~ OR OWN1!:R TO CONstaUC'l' i fi, n'""'N·• AND SPt<;ll'ICATIONS SUSMmED T() AN0 R!MSW!J;n BY TH& BlJILDINCI DEPART'MI!NT. nl~ SfONE:R. T>l£REEJY AGP.EE'.t-1 TO COMPLY wrrH All~ SrJJLOlNG CODES A.t~D r..AND FUru!UANT1'0 AUTiiORriY Gf\!'EN LN i;l!0.'-8.201 CRS liS AMSNT,)Il;b. THE ~~ot'4E'Rf1.fm'Mt:IA ACHE~!:~ ARE NOT l'tll.LY COMl'!LllO wmr m THE 1-COADOJ'<, tl<ECTION. CON$TRUCTION, AND USE OF TilE , Tim P<PM!T ~,,.,. nE RllVOK!ll> !lY NO'TIC£ FROM T>!& COUN'IY ~No Tl!A~ '!'!lEN ~N!> n!ER& rt SHALL lltc'.OME Perot.~ .B"!I!IS:O uPON P'J.AI'IlS, ~nCJlllCAnON::i AND ~ OATA f!liA1L N01' ~THE Btm :nwd OFFICW. ~~CTJOI'J OF ~OitS IN IMlO PUNS, SF'OOmt:J\TrO,Nfi .MD O'Il'i&~ IJATA OR. J~OM ~NTrHO ~lJILoll'I.:O ~~i~3~~~~0N:1Hgi!F.!l\E·· INDER wai!N !II V!Ot.ATIQN OF "/f!S OODE OR /\NY QTHER OtWIIW<CE OR REour.ATJON or 1M'S Pl.t\N'S ATIIP SPP..Crm,;;(OON!i t.rm JNf;J'IilC'hONS OONDUC'l'Etl ~R DOES Nat CONS't'IM~ /Ill ~CCE!'ri'J'ICE OR LIABl.m!O& BY QARI'IEUJ ~.OUNn' FOR ERRORS. OII!ISSJd~~ OR D!SCREI'&NC!E$. "THE RE«PONSJ ~n.m I"'R Jr.!P!.EMilNTA'l10N OURJNG (:CNBTR~C'.l!ON RESTS $~mCIAlLYWJl'H THE ~RTIC!'llCT. ~ESlGN~~. 811lWNR. AND 0~ IN'm?m!:D '1\7 01:: CQ'N~~AT:I'\'m liND IN sVPPo.r. ot T'H~ 0\\'NER$ u-rrsF:r:",..;.T, ~ fttVI ,/ Fee HAVE RUt> AND UNilERSriiNI:J 111~ AGRJ:SII!Il"-r A~O>'B ON,l!IAI.I~ s-e.-o.![.. Ct. t<l -""· " • --.. 7~0."-• The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. 9. If you will be connecting to a public water and/or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTIFICATE OF OCCUPANCY MAY TAKE UPTO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupa1c.x_1 qse_qnq the issuance of a Certificate of Occu ancy for the dwelling under building permit# _(\JV\_!Y ---'-""'--'----'----\--, - Signature Bpapplicationoctober2006 Date VALUATION/FEE DETERMINA TION Applicant e ~L eo~~ Address qq MO:S b fi#0 Date S-IO·o1 Finished (Livab le Area): Main \N lfM H'CJY-')!. Upper J'l2o r 39 ~r :: 7~ 51o9 0o , Lower Other Basement: Total Square Feet Valuat ion Unfinished Conve rsion of Unfinished to Fini s hed Plan Chec k Fe e for Convei·sion Valuation Garage: Valuat ion Crawl Space: Valu at ion Decks/Patios: Cove red Valuation Open Valuation Total Valuation (/;. 7 fo S {, Cf 1 ~ (Qo GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least IS"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 ffiC, IPC, IMC and IFGC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the fiplat with the proposed structure located within the envelope. · Yes 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes No Not necessary for this project ,..><? __ 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? YesJ2--- 2 4. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes No__ Not necessary for this project )<J 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yesx.-:, No__ Not necessary for this project __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered desig~~ Yes_JV__ No__ Not necessary for this project __ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered fouw?(r plan for this building? Yes No__ Not necessary for this project __ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes__ No__ Not necessary for project><? 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes-f5J-No__ Not necessary for this project __ 10. Do the plans include design loads as required under the IBC or IRC for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County)? Yesft-No__ Not necessary for this project __ 11. Do the plans include design loads as required for floor loads under the IBC or IRC? Yes__ No__ Not necessary for this project>o 12. Does the plan include a building section drawing indicating.foundation, wall, floor, and roof construction? Yes~ No__ Not necessary for this project __ 13. Is the wind speed and exposure design included in the plan? Yes-t--No__ Not necessary for this project __ 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceili~oists, roof rafters or joists or trusses? Yes No__ Not necessary for this project __ 3 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes-(Q-No__ Not necessary for this project __ I 6. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) YesL No__ Not necessary for this project __ 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Yes__ No__ Not necessary for this projectL 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the me or IRC? Yes__ No__ Not necessary for this projecy22._ 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IBC or IRC? Yes__ No__ Not necessary for this project~ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes_p;£ No__ Not necessary for this project __ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes__ No__ Not necessary for this projec~ 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes~ No Not necessary for this proj(!ct __ _ 23. Have all areas in the building been accurately identified for the intended use? (0CC4,!PifCY as identified in the me Chapter 3) Yes~ No__ Not necessary for this project __ _ 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes__ No__ Not necessary for this projectF-- 4 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes__ No__ Not necessary for this project&_ 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes__ No__ Not necessary for this project-X- 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes__ No__ Not necessary for this projeciSL_ 28. Have two (2) complete sets of construction drawings been submitted with the appl"on? Yes No __ 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes,LQ_ No__ Not necessary for this project __ 30. Does the plan accurately indicate what you intend to construct and what will receive a final)<gpection by the Garfield County Building Department? Yes No __ 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For comer lots see supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Yes)><:: No __ _ 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes,&.-No __ 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your builp permit? Yes No __ 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and rupancy of the building? Yes No __ 5 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with /<JUniform Codes? Yes No __ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes~ No ___ _ 38. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes!<: No ___ _ 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes )(2 No, ___ _ 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to subm~ of the building permit application? Your attention in this is appreciated. Yes No ___ _ 41. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes )<) No (Please check with the , building department about this requirement) 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading 12~mit? Yes -f('J---=---- 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than I 0 persons as per Section 1004 of the IBC to !~pare the plans and specifications for the project. Yes C No Not Necessary for this project ____ _ 6 I hereby acknowledge that I have read , understand, and answered these questions to th~Y/1 ~ ·q/Jc/o7 Signature Date Phone: 9f?.--5{7 6 (days); Project Name: 1J ()I'-' D Note: _,6""--Z_)_-_5_]_3_Y __ (eve nings ) fb_(a, loW)Wf!TCI'ci{ {_.L (_ If you answered "No" on any of these qu estio ns you may b e require d to provide thi s information at the reques t of the Building Official prior to beginning the plan review process. Delay s in iss uing the permit are to be expected. Work may not procee d without the i ss uance of the permit. *If you ha ve answered "N ot neces sary for this project" on any of the ques ti on s an d it i s de termined by the Building Official that the information is necessary to revi e w the ap pli cation and plans to determine minimum compli a nce with the adopted codes, pl ease expect th e following: A. The a pplication may b e placed behind m o re recent a pplications fo r building permits in th e review process and not reviewed until re quired information has bee n provided and th e application rotates again to firs t positi on f or review. B . D e lay in i ssu ance of th e permit. C. D elay in p roceeding with construction. *If you answ ered "No " to thi s questi on the circumstances described in th e question cou ld result in a "Stop Work Order" b eing issued or a "Ce1tifica te of O ccup ancy" not b eing i ssued. Bpcomm April 2006 7 PLAN REVIEW CHE CKLIST Building ~Engi n eered Foundat i on _LDriveway Permit /surveyed S ite Plan ~S eptic Permit and Setbac ks _LGradefTopography 30% ~Attach Residential P lan Review Li s t .c.L_Minimum Appl ication Que sti onnai re L s ubd i vi s io n Plat Notes ~Fire Department Review L Valu at io n De termination/Fees __LR ed Line Plans/Stamps/S ticker V Attach Condition s Planning/Zo ing __ Property Line Setbacks 30ft Stream Setbacks I . __ Fl o/_ Plrun __ Bu .lding Hei ght HONDRC Appr oval GradefTopograph y 40% Subdivision Plat Notes __ Applicati on Signed '~ .fo ~~ ~ fj"' 't--z;"""~.J__ -.£Plan Rev i ewer To Sign App li cation d Parcel/Schedule No. J4&_40# Sn o w l oad Let ter-Manf. Hms. / So il s Rep ort GENERAL NOTES: GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY (OVV\V'AeHiuL "'S~te 'a,\Cl -G w:S. Owner's Name Rtl'Clc\1\tM Present Address :1520 '5. ()JQV\.t\ t,\2£ ' Permit 4361 Assessor's Parcel No. This does not constitute a building or use permit. System Location_Q-"-q'---'-'""'-'"""-'-"-'--..l.l.!us;.~.L..\"'-'V\;=l),_"t"-'-----------.--------- Legal Description of Assessor's Parcel No. ~~ SYSTEM DESIGN ______ Other _ __,f.:'-':s"b=---Septic Tank Capacity (gallon) _ _:2=-:.0=--Percolation Rate (minutes/inch) ~44 Number of Bedrooms (or other) _ _:_--'--- Required Absorption Area-See Attached /S~ ~~ Special Setback Requirements: Oate ____________ lnspector -------------------------- FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System lnstaller ___ _.~""-'<lL-¥-l""'=:_ ___________________________ _ Septic Tank Capacity __ ~U<f)()~.l.OL _____________________________ _ Septic Tank Manufacturer or Trade Name -~""'"-"'"'~"""'""'=ILL• ------------------~--- Septic Tank Access within 8" of surface _-J4&'_1,::: _________________________ _ Absorption Area _L/~S<--"~"-""'.""''--"~-'-=--'od,=::.::..:"-----~.~-----------------­ Absorption Area Type and/or Manufacturer or Trade Name -~-":;;'-"9""'-""""""~='-"''---'1~0!~""'"'-""'='--'-lf---=?=-.Jc[?.c.:::g:_6 __ Adequate compliance with County and State regulations/requirements~l)~e.,!,)k-k:::.. _______________ _ Other _________________________ ~----------------------- Oate_-1-j_..Q,__-q_,__-_j72""-].f.-___ lnspector _,IJM;dcu::=='f,L__7tui.L.fi""""«l!!-"'r:__ _________ _ RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, "alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine-6 months in jail or both). White· APPLICANT Yellow· DEPARTMENT No. --'"}Q.=L{.........:· --"-t_,_Y __ Job Address qq '5\r'ttl>r Owner Poro.tr,Gfe, C('l)'IY'.I'rJ>f'C l.t\l Contractor $\<~r ?xt::c"~ Assessor's Parcel No.:J,qCA "531-O'S~ Date S-cf-Cf-Ol- PERMIT CARD ·~\~IS t Address~ S. CJ%Sl\fi:) \l:>IJ2 Address \J>C'P 0 Jb<J:\ ~,It l<:: ,: Phone # Ol.\J-L\<J.i'S Phone #Q(fl.-"S1-if. ~acks: Front Rear .------RH _____ LH'-· _____ Zoning ____ _ . lc:.l 5\Dr--te. (UJ~ncu-:ej INSPECTIONS Soils Test~..-,..-,-~.,..,~----­ Footing S-30 -o1~ Foundation ~ -1:-DJ P<5'M Weatherproofing _____________ _ Mechanical _______ 7r--...---=---- Eiectrical Rough (State) 7 Grout _____________ ~~---~=-- Underground Plumbing 7-{p -o 7 &M Rough Plumbing &·l-5-"'\VJ~ Electrical Final (State)~;;t'Co~~~it~ffi~ Final /~ -U-07 /Checklist Completed? Framing 1-dlS-Q1 ~ ~ Insulation 1-Y£--o ?.Rmt Roofing • lv-T-V I i@'= Drywall I~ -E.-a::> 'J ~ Certificate Occu~ancy # Si">Oq Date _s.m;:p _jl:d-<\-0':\- Septic System # -.::;!;<%~+--=-=--------- Date :&-~0_3: Final \6""69-d=f Gas Piping-------------Other ------------------ EXTERIOR Address No.------------- Drainage-------------- Decks-support & clearance to wood ------ Decks-stairs & ralls----------- Exterior locks ----'--------- Flashing around doors & windows------- Insect screens ___________ _ INTERIOR GARAGE Fire wall separation __________ _ Service doors-Hi" min.-----~---- Door (20 min.) w/auto closer-H1" min, ____ _ Mech. equip. 18" above floor _______ _ No opening into sleeping area _______ _ BASEMENT-CRAWL AREA Access _____________ _ Insulation------------- Headroom/Stairs ___________ _ Ventilation------------- NOTES FINAL CHECKLIST MECHANICAL ROOM Boller ____ _c_ ______ _ Hot water ____ _o_ _____ _ F.A. gas/oil _________ _ Floor drain _________ _ Clearance _________ _ Air con. system•--------- Hot water heater-------- Combustion afr·--------- Gas piping, valves _____ _: __ LPG Drain---------- FIREPLACE/STOVE Clearance to combustibles _____ _ Termination of chimneY'------- Combustion air ________ _ Hearth (12" or 20" on sides)----- Glass doors _________ _ Certified by:~--------- REMARKS (continue on back) STAIRWAYS. Headroom (6'6") ---------- .Railing & guardrails--------- Width--~---------­ Rise & run----------- KITCHEN Clearance above grill--------- Exhaust fan ___ _;_ ______ _ Broiler exhaust (1 hr. chase)------ BEDROOMS Egress ____________ _ Smoke detector---------- BATHROOMS Exhaust fan _____ _: ____ _ Shatterproof glass, _________ _ OTHER - INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued .. S.::~"??.:?..?.c ... Zoned Area ............................ ~rmit No ... l~~~Y.::l .............. . AGREEMENT In considerati"n ,.r '"e issuance of this permit, the applicant hereby agrees to comply with all ;A,. • .auu rc~; ....... uus relaied to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use U,\cl <;;ji}roqe Wl:)teOO~:€ Address or Legal Description 9.9 'MOsher 1\ve. Porocnu\~ OwnerB:ttucV\IJ\e CQ>'Mwerc\ttl.., Contractor ":S1Cif-IJ~ Setbacks Front Sjde Side Rear This Card Must Be Posted So II is Plainly Visible From The Street Until Final Inspection. · INSPECTION RECORD Footing 5-3o·o{ ~ Ll F<J... ck Driveway Foundation 0~~~ {)/ 0\"C'-~ Underground Plumbing { • (, -1>/ /0f/'J Insulation 1-%·61 ~ Rough Plumbing &-G·uf\ G.l--J Drywall !P-:r~/dYvG Chimney & Vent /f1jl Electric Final (by State Inspector) 9·28'-t77 Gas Piping /)VV Final f()_~~l~o7 ,{)rYv Electric Rough (By State Inspector) 7c&:r07 Septic Final IC-CJ·ll7 Mfl.- Framingfr~ OK ,~~~lo11h/. Notes: (To include Roof in place and Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVEDDO NOT DESTROY THIS CARD Date 'S--(}S-o'+-By_~~-- IF PLACED OUTSIDE-COVER WITH CLEAR PLASTIC rage 1 01 .J Garfield County Assessor/Treasurer Parcel Detail Information A~s~ssor/Ir~'tsm·Qrf'roperty Semch I Assessor Subset Oue_ry I Ass~_ssor Sale~_Se;n:~h Clerk & .... Re~Prd.er ReceptioiJ S e'lLC.h Basic B11ilding Characteristics I Tax:Jnformation Parcel Detail I Value Detail I Sales Detail I Residential/Commercial Improvement Detail Land Detail I Photographs I Tax Area II Account Number I 046 II R260037 II Parcel Number II Mill Levy I II 240933105oo2 II 39.762 I Owner Name and Mailing Address !PARACHUTE COMMERCIAL, LLC I IPOBOX700 I !GLENWOOD SPRINGS, CO 81602 I Legal Description lsECT,TWN,RNG:33-7-96 SUB:TRAVELERS !HIGHLANDS SUB. BLK:8 LOT: I -LOT: 10 lsUB:TRA VELERS HIGHLANDS SUB. LOT: 15 1-LOT:24 BK: 1726 PG:994 IRECPT:682395 BK: 1724 PG:305 IRECPT:681758 BK: 1644 PG:688 I IRECPT:664506 I Location I Physical Address: IIPARACHUTE I I s bd' . . IITRA VELERS HIGHLANDS u I VISIOn: SUB. I I Land Acres: IJo I Land Sq Ft: ll10o,ooo I I Section II Township II Range I II II http://www.garcoact.com/assessor/parcel.asp?Parce1Number=240933105002 5/24/2007 Page 2 of3 II 33 II 7 II 96 II Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 56,80011 16,4701 I Improvements: II 0 11 oj I Total: II 56,80011 16,4701 Sale Date: 119/2/2005 Sale Price: 11850,000 Basic Building Characteristics Number of Residential jo I Buildings: Number of Comm!Ind jo I Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type II Amount I I 2006 II Tax Payment: Whole II ($336.80)1 I 2006 II Tax Amount II $336.801 I 2005 II Tax Payment: Whole II ($323.46)1 I 2005 II Tax Amount II $323.461 I 2004 II Tax Payment: Whole II ($438.74)1 2004 Tax Amount I $438.741 2003 Tax Payment: Whole ($468.94)1 2003 Tax Amount $468.941 2002 I Tax Payment: Whole ($82.28)1 I 2002 II Tax Amount I $82.281 I 2001 Tax Payment: Whole II ($87.46)1 I 2001 Tax Amount II $87.461 I 2000 Tax Payment: Whole ($102.58)1 I 2000 I Tax Amount $102.581 I 1999 II Tax Payment: Whole ($80.34)1 I 1999 II Tax Amount $80.341 http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=240933105002 5/24/2007