HomeMy WebLinkAboutEngineer ReportPAT1'ILLO ASSOCIATES ENGINEERS, INC.
STRUCTURAL CONSULTANTS
1215 grand as en He. post office box 751 olemwod springs. Colorado 81602
phone (970) 9.159695 fax (970) 915..1921 e-mail: infra paean ncers.eom
May 12. 2014
Mr. Dale Titus
0171 Fairway Lane
Glenwood Springs, CO 81601
Re: Titus Residence Remodel
PAlal 13019
Dale.
This letter is in regard to your desire to cut hack one of the 91/4" 13CI 6000 series joists in
the main floor framing of the remodel, approximately 3'-0 away from one end, to
eliminate a conflict with a plumbing dram location. Based on structural analysis_ we
conclude that the floor joist may he cut back and re -supported from the adjacent Iloor
joists with a single 91/2" RCI 6000 I .joist header. Both the Iloor joist 10 be eta and the
new header shall he supported with Simpson IUS3.37/9.5 joist hangers. Install web
blocking, extending a minimum of 9" to either side of the hangar. for attachment of the
face mount hangers. No additional reinforcement or modification to the Iloor joists
supporting the new header are required.
Please contact our office with any questions or concerns.
Sincerely, Reviewed by:
Michael Struntph, P.E. Robert Pattillo, P.E.
Project Engineer Principal Engineer
email cop3: I)ale'1 plus Idnitm uuinail coin)