Loading...
HomeMy WebLinkAboutApplication-Permit7:///e- Cof/ Karen Donelson 4778 CR -331 Silt, CO 81652 August 3, 2011 Re: PERMIT # BLRE-11-10-1832 Dear Ms. Donelson, BUILDING & PLANNING DEPARTMENT In review of our building permit application files, we found your application which was filed at least 180 days ago. As per the 2009 International Residential Code, Section R105.3.2: An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing unless such application has been pursued in good faith or a permit has been issued... Please be advised, building permits are deemed active for 180 days from date of issuance, and will remain active for 180 days from the date of an inspection. If no activity occurs within the 180 days, the permit will be deemed expired. As per the 2009 International Residential Code, Section 8105.5, the building official may grant one or more extensions of time, for no more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. In hopes of issuing your permit, please contact us within ten (10) business days of the date of this letter regarding your application. If we do not hear from you, we will deem your application abandoned and dispose of your file and plans. Thank you for your timely response in this matter. Regards, David Bartholomew, Plans Examiner Garfield County 13uilding & Planning CC: Andy Schwaller, Building Official 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-82121 Fax: 970-384-34701 Inspection Line: 888-868-5306 www.gartiield-countv.corn 1 Parcel No: (this information is available at the assessors office 970-945-9134) 2.14k1- 31/44-oo- 2 Z 3 ? Job Address: (if a address W � (c ?.fJ has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description ,Qzx.a1-5 3 Subd./ Exetnptiop: Lot No: Block No:�.1011 v ,/(,j 4 Owner: (prope owner) r � ed(---11 Mailing Address: LJ7 (t?'sI 1114 Ph: q7 27rS7_ Alt Ph: 5 Contractor: Mailing Address: Ph: Alt Ph: 6 chit ct / En 'neer: k,,. ( \ 11 411 Ma ling Address: R 'RIz) S4 t Ph: 4req, ext 1! e Ci r, yCi Alt Ph: 7 Sq. FFL f Building. Sq. Ft. or Acres of Lot:r� 1v tiYt' (Y V a Rei t: No, Floors: 8 Use of Building: �'-LC ) r nt k).(•" fi) (cteK., 9Describe Work: ty 10 ip...„4......„.. Class of Work: i o New o Alteration trillion 11 Garage: ❑ Attached o Detached Septic: t ISDS o Community 12 Driveway Pertnit: , j ` Owners valuation of Work: $ q' Authority. This application fora Building letter of authority, signed by the A Building Permit cannot be NOTICE Permit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate Owner, must be provided with this Application. issued without proof of legal and adequate access to the property for purposes of inspections by the Building Depamnemt. maybe required: (1) State Electrical Permit, (2) County ISDS Pemlit, (3) another permit required far use on the property identified above, e.g. State or or a State Wastewater Discharge Permit. null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION and that the information contained above is true and correct. i understand that the Building Department accepts the Application, along with the plans by me or on my behalf (submittals), based upon my certification as to accuracy. approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on Permit, I agree that 1 and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. to enter the property, described above, to inspect the work. 1 further acknowledge that the issuance of lite Building Permit does not prevent the of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation law. and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without ar builder. READAND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: �' DATE I 1 _ 2 / 1 C) Leaal Access. Other Permits. Multiple separate permits County Highway/ Road Access Void Permit. A Building Permit becomes days atter comntencernent, I hereby certify that I have read this Application and specificationsand other data submitted Assuming completeness oldie submittals and the submittals reviewed by the Building Department. In consideration of the issuance of the Building Code, ISDS regulations and applicable land construction or use of the structure(s) and I hereby grant permission to the Building Department Building Official from: (I) requiring the correction of County Regulation(s) or any other applicabk Review of this Application, including submittals, ar discrepancies. As the Owner, 1 acknowledge limitation my architect designer, engineer and/ 1 HEREBY ACKNOWLEDGE THAT I HAVE OWNERS SIGNATUII 4721111.'t.--„,_1 STAFF USE ONLY Special Conditions: Adjusted Valuation: q, 708'. y c Plan Check Fee: 07.81 Permit Fee: ) B I. lS Manu home Fee: 11Iisc Fees: [SDS Fee: To al Fees: 2‘19,06 Fees Paid: Balance Due: BP No & issue Date: ISDS No & Issued Date: `113D Setbacks: OCC Group: Const Type: 7„�oning: T 131 DG DEP': PLNG DEPT:(\ APPROVAL DATE APPROVAL DATE The following items are required by Garfield County for a final Inspection; 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all 113C and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. 1 understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNER GNATURE DATE Bapplicationdecember2007 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and 1 original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2009 IRC, and 2009 IECC. 1 Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes ✓ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 3-301 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes ✓ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? Yes if Yes please provide a COPY. No 2 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes V1&),( 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes „4,No 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea Ievel), floor loads and wind loads? Yes ✓ 11. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes ✓ 13. Does the building section drawing or other detail include the method of positive connection of all columns ar d beams? Yes ✓ 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase 11 certifications or phase IT EPA certification? Yes No 3 16. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes})'4 No 17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping room and/or basements comply with the requirements of the IRC? Yes ✓ 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation f9r all habitable rooms? Yes VtAbil 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes ^A4 No 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes ,,ti}Q 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes _J0,4 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes 23. Will this be the only residential structure on the parcel? Yes No _ If no -Explain: 40,E 24. Have two (2) complete sets of construction drawings been submitted with the application? Yes 25. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes 4 26. Have you designed or had this plan designed while considering building and other construction code requiremen s? Yes 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes 29. Do you understand that approval for design and/or construction changes are required prior to the application o hese changes? Yes 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impart" or "Septic System" fees required, at the time you pick up your building permit? Yes z/ 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 888-868-5306. Yes No 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -i y.e ion fee? Yes 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the 1RC? Yes ,� 5 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes 37. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance Qf a building permit that you will be required to obtain a grading permit? Yes V 39. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes % 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes 44 I hereby acknowledge that I have read, understand and answered these questions to the best of myility. Signature of Owner /!/3 /(v Date Phone: /2f (days); 3 7 /2/ ?j Project Name: 1 CAP (Cel ,.• (evenings) Project Address: .7,77-9S-, a 3 S,i � Lj 6 1111712010 10:34 970-625-4933 CO RIVER ENG. PAGE 01101 3ketchPicture.jsp (7PEG Image, 540x540 pixels) https://actgarfield-county.comlassessor/taxweblsketchPicture.jsp?acco... 1").4 lene,(Scl& grene dtWW 1 of 1 l3_AGVlic..t C.O�Ga- 42' 11/17/2010 10:10 A Property Line Existing Home Existing Barn CLIENT COLORADO RWE F' ENfl1NEERIN& Ia661P61ATi6 PO Box 1301 Rifle, CO 61650 Tel 970-625-4933 Fax 970-625-4564 Dean & Karen Donelson 4778 County Road 331 8111, Colorado 81652 PROJECT Donelson House Addition SHEET TITLE Dean & Karen Donelson Site Plan SHEEI NU FI FILE A1.lLand Projects 821838-Screanlin EagloLdwgPiorno n,dwg Revision Z 4.. 2x8x12 Rafters 16" o.c. simpson rafter 8e to wall 2x6 W:II Frami 1: o.c. Grade to Slope away from building a min 10:1 • 3' 2'6"x1'8" Window 3'-0" 10' 2" 28' tall - 8" Steni Wall on 20"x8" Footer South 10 Existing Wall on Main Residence r -0" West 13l4:1' 2'6"x1'8" Single Hung Window Bathroom Addition (10'0"x13'0") 130 sq ft T1G Wood Flooring Radiant Floor Heating Single Pole Light 4" Slab on Grade Reinr. Concrete 1-IwCw 4" Sewer Drain Cw }'orth 2'6"x6'8" Right Hand Door 2x8x12 Rafters connect to existing wall on 2x8 header board with hangers 2x6 Wall Fran 9'-9 • 16" o.c. 1 J L South Elevation 6' 13'-0" 0.-10" 3/4 CDX Plywood Roof Shoaling with bitchathane Existing Wall on "Existing Residence 30Yr. Composite Architectural Shingles L_ 1 West Elevation Existing Structure,, Tongue and e Siding 1. COLO 4 DO RIVER ENeINEEglNe INCORPORATED PO Box 1301 Rifle, CO 81650 Tel 970-625-4933 Fax 970-625-4564 CLIENT Dean & Karen Donelson 4778 County Road 331 Silt, Colorado 81652 SHEET T PROJECT Donelson Room Addition • /Q119/i c/f-hLed '91,rd ec/ (?Ie c/o5'c1, //Ask' ,- 3:12 9 Grade to Slope away from building a min 10:1 —10' 10' 2" 28" tall - 8" Stem Wall on 20"x8" Footer L I_.1 t_ J North Elevation SHEET NO. OF 2 BIRE-11-10-1832 Donelson, Karen bath add L 4778 CR 331, Silt FILE M:1Land Projects R21838 Screamin Eagleldwg\HomeAddition.dwg Revision /9\ \ ./ Woo Gro 9'-f // Ai i 1x8 Cedar Fascia ing ,.�� Z — --- 13'-0" 64" tall - 8" Stem Wall on 20"x8" Footer (36' Stem Wall above grade) L_ 1 West Elevation Existing Structure,, Tongue and e Siding 1. COLO 4 DO RIVER ENeINEEglNe INCORPORATED PO Box 1301 Rifle, CO 81650 Tel 970-625-4933 Fax 970-625-4564 CLIENT Dean & Karen Donelson 4778 County Road 331 Silt, Colorado 81652 SHEET T PROJECT Donelson Room Addition • /Q119/i c/f-hLed '91,rd ec/ (?Ie c/o5'c1, //Ask' ,- 3:12 9 Grade to Slope away from building a min 10:1 —10' 10' 2" 28" tall - 8" Stem Wall on 20"x8" Footer L I_.1 t_ J North Elevation SHEET NO. OF 2 BIRE-11-10-1832 Donelson, Karen bath add L 4778 CR 331, Silt FILE M:1Land Projects R21838 Screamin Eagleldwg\HomeAddition.dwg Revision /9\ \ 1"x8" Cedar Fascia 2"x8" Sub Fascia 30 -Year Arch Dimensional Shingles lce & Water Shield 3/4" CDX Roof Sheeting \ Sofit 2x8 Block between Rafters toenail w/ 16d @ 8" o.c. 1/2" exp. mat'l typ. #4 12" o.c. each way 4" Conc. Slab 20" Rafter Hanger 2x6 Stud @ 16" o.c. 1/2" x10" anchor bolts at 48" o.c. in cont. treated 2x6 #5 Horiz. at 10" c.c. 8" concrete foundation wall - bitiminous dampproofing 2" rigid Insulation #4 Vertical at 16" o.c. 'q a 36" M'nimum Frost Protection interior side 1x6 Cedar Siding install per manufacturers rec. air & water infiltration barrier 5/8" exterior grade plywd. shthg. 2x6 wood studs @ 16" o.c. R-19 batt insulation 6 mil poly vapor barrier 5/8" gypsum board w/ skip trowel! finish Design Features: Square Footage: 130 sq ft Floors: 4" Reinforced Conc. Slab on 6" aggregate base course - T&G Wood Floor finish Interior Walls: 2x6 frame - Sheetrock/skip trowel! finish Exterior Walls: 2x6 frame - Rough cut cedar tongue/groove wood Exterior Roof: 2x8 rafters, 3/4" CDX Ply sheating with bitchathane and 30 -yr Arch Dimen. Shingles Heating: Radiant tied to existing home Utilities: Hot water and Cold Water extended from existing residence. General Design Requirements: Codes: 2009 IRC, IBC, IFGC, IMC, IPC, IECC Roof Snowload: 40 psf Seismic Design: B Wind Speed: 90 mph Wind Exposure: B or C (R301.2.1.4) Frost Depth: 36" Insulation: Windows U=.35 Minimum R Values: Ceilings/roof R-38 Walls R-20 Slab Perimeter and depth R-10/24inch Common Walls R-20 Drainage: Slope away from building min, 10:1 for 10 -ft General Construction Notes: 1. All footings to bear on undisturbed natural bearing materials or structural fill. Avoid excessive wetting or drying of the excavation, keeping the excavation reasonably dry during placement of the concrete for footers. 2. All concrete shall attain 3,000 psi compressive strength in 28 days and be Portland Type I-11 Cement (ASTM C150) with 4-6% air entainment. Concrete aggregate to be normal weight. 3. Perform all cast in place concrete in accordance with "Specifications for Structural Concrete for Buildings" ACI 301-84 unless otherwise noted. 4. Reinforcing steel shall conform to ASTM A615: #4 and smaller = Grade 40, #5 and larger = Grade 60. 5. Horizontal reinforcing steel shall be made continuous by overlapping bars a minimum of 32 bars diameters at all splices and providing corner bars. Fabrication and installation shall conform to ACI 315. 6. Strutural framing lumber shall be a minimum #2 Grade Hemlock Fir for Plates, studs, joists and rafters. 7. All sill plates in contact with masonry foundation shall be foundation grade redwood or pressure treated hem -fir #2 or better. 8. Metal connectors for wood framing are manufactured by the Simpson Strong -Tie Company or equivalent. COL DO p 4 Rtv ENGINEERING, INCORPORATED PO Box 1301 Rifle, CO 81650 Tel 970-625-4933 Fax 970-625-4564 CLIENT Dean & Karen Doneison 4778 County Road 331 Silt, Colorado 81652 SHEET TITLE Dean & Karen Donelson Detail Sheet PROJECT Donelson Room Addition FILE M:\Land Projects R2 \838-Screamin EagleldwgillomeAddition.dwg SHEET NO. 0F2 Revision A