HomeMy WebLinkAboutApplicationGarfield County
Community Development Department
108 8"' Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-county.com
TYPE OF CONSTRUCTION
Er Commercial/Multi-Family
❑ Manufactured Home (SF or Duplex)
❑ Residential (SF, Duplex, or Townhome)
BUILDING PERMIT
APP CATION
0 Demolition
0 Reroof
INVOLVED PARTIES
Property Owner: Ne? Yy C reRn 4-igiA Cj wrc H Phone: (470 ) q r— 9C] 2
Mailing Address: P.O fx 19416 C� (p vwwoor% Sr)rincJ y Co. 431,09
Contractor: Novi Ci-2L--1-icy C Lt,,,c11 Phone: (970) gLF5,SgQ2
Mailing Address:
Architect: L___ P
Mailing Address:
Phone: (C:21.{,,) 454 —11Lt17
Engineer: \ACJ t.�p
Mailing Address: 22.4. Q'&; w,by S+.
Phone: (hit" )/4-54 11Lk
RE Urep vci- Rap ,Yr 1t45Ocj
Manufactured Home Installer: Phone: (_)
Mailing Address:
PROJECT NAME AND LOCATION
Describe Work: Isle w Gr ecc_-1i o r\ P r/ , c_iR tool
Job Address: 4t+'7c,1 14WY Ga Spr-inc5
Assessor's Parcel Number:2./7 15200098 Sub. Lot Block
Owner's Valuation of Work: $ /, son, oeir, Property Size (Sq.Ft or Acres): 1!a
Height: Zo r # of Floors: / _
Sq.Ft of Building: /4/ Coo
Class of Work: 'New 0 Alteration 0 Addition 0 Repair 0 Move/Relocation
Garage: 0 Attachedtt0 Detached
Septic: (OWTS 0 Community
Type of Heat: 1B"Natural Gas 0 Propane 0 Electric 0 Other
Driveway Permit: I"Exempt 0 Permit #:
NOTICE
Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or
an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the
Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or
a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of
the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. 1
understand that the Building Division accepts the Application, along with the plans and specifications and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of this Application, a Building Permit will be issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the
Building Division. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply
with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, OWTS
regulations and applicable land use regulations (County RegulationIs)). I acknowledge that the Building Permit
may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s)
and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction
or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law.
Review of this Application, including submittals, and inspections of the work by the Building Division do not
constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the
Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations
rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or
builder.
I hereby acknowledge that I have read and understand the Notice and Certification above as well as
have provided the required information w ich is correct and accurate to the best of my knowledge.
g -Of
Property Owner Print and Si
3 /z /r
Q to
OFFICIAL USE ONLY
Spedal Conditions:
Adjusted Valuation:
i 034,708
i
Plan Check Fee:
377. 3,c
Permit Fee:
57/ 9.0
Manu home Fee:
N!A-
Misc Fees:
Total Fees:
q 4 36-(c.
Fees Paid:
3, SI lam. co
Balance Due:
✓; q I q. 55'
BP No:
OWTS No:
tat_- 3 bE
?i -1-- 3,`a(¢ 9--
Setbacks:
134lZ5510
OCC Group: ' y
(�
Const Type:
Zoning:
C,L
BUILDING / PLANNING
DIVISION : AT, �� : • `�� i -a) -2i:) --
orpprova Date
—
WA '&18-1
J*wro3 s3,
NOTE: If any required information is missing, delays in issuing the permit are to be expected. If
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The Permit Fee, as
well as any Septic or Road Impact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by a person having written authority from the
owner to act as their representative.
hereby acknowledge I have read, understand, and will abide with the requirements of this
checklist.
Property Owner Print and Sr Date
Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-countv.com
COMMERCIAL OR
MULTI -FAMILY
BUILDING PERMIT
APPLICATION CHECKLIST
COMMERCIAL OR MULTI -FAMILY BUILDING PERMIT APPLICATION CHECKLIST
In order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application.
• Parcel number obtained from the County Assessor's Office.
• Job address (assigned physical address).
• Legal Description: lot, block, filing, subdivision or tract, section, township and range.
• Owners name, mailing address, phone, fax, or cell.
• Contactors name, mailing address, phone, fax, or cell.
• Architect/Engineer's name, mailing address, phone, fax or cell.
• Building size, height, number of stories, lot size.
• Use of building (commercial)
• Class of Work (new, addition, alteration, repair, demo, move, other)
• Description of work.
• Type of heating (natural gas, propane, electric, other)
• Sewer system (Community or OWTS), also see other items below.
• Garage (attached or detached)
• Driveway permit (please see other items below)
• Valuation (labor and materials)
OTHER ITEMS:
• If you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. (Required to submit building permit application).
• OWTS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board.
• At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached at 970-625-8601.
• If you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
If you belong to a Homeowners Association, it is your responsibility to obtain written approval, if
required.
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Projects with more than 10 occupants require plans sealed by a Colorado Licensed Design
Professional. Occupant load shall be calculated by IBC Table 1004.1.1.
• A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to
the local Fire District for review prior to permit issuance. All plans will be checked at the counter for
completeness. If any of the required information is missing, the building permit application cannot be
accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain, and easements.
• Provide setback distances from boundaries, buildings, septic, well, and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures include sheds, barns, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable)
• Retaining walls (engineer stamped detail required for walls over 4 ft, measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped, and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
COVER SHEET:
• Project identification.
• Project address and/or legal description.
• Design specifications to include building use and occupancy classification, type of construction,
building height and area calculations, occupant load, and fire sprinkler systems.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Per G.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Design Professional stamped plans.
• Minimum 4 elevations (N,S,E,W)
• Floor plans for each level including dimensions and scale noted.
• Clearly label each room or space (office, storage, mechanical, elevator, etc).
• Wall types; clearly labeled and referenced. Identify all fire resistive wall construction.
• Construction details for all fire resistive elements referenced on floor plans and cross sections.
Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire
resistive listing number referenced on each assembly detail. (ex. UL P123)
• Window & door sizes, types, and operation and direction of swing noted on the floor plan.
• Specify roof slope/pitch, roof covering, and siding materials.
• Energy design specifications/details for R -values, U -factors, and SHGC's per IECC.
• Stair and guard details specifying rise, run, height and spacing.
• Accessibility; show compliance with accessibility requirements for all elements of the building per
IBC, Chapter 11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Engineered foundation design per soils report. Geotechnical report referenced.
• Design specifications to include roof and deck snow load, wind and seismic design, frost depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all
live/dead loads specified.
• Framing /connection details referenced on plans.
• Pre -manufactured structures require an engineers stamp, signature, and date.
MECHANICAL PLANS: Please provide the following information on the mechanical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant Toad exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Energy design calculations and details verifying compliance with the 2009 IECC.
• Floor plans for each level showing size, location and materials of all ductwork, plenums, return
and outside air intake registers.
• Size and location of all combustion air ductwork and openings.
• Size, type and termination of all gas appliance flues and vents.
• Location of all fire and combination smoke/fire dampers.
• Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc).
• Commercial kitchen hood location, hood and duct sizes, CFM calculations.
PLUMBING PLANS: Please provide the following information on the plumbing plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location.
• Water piping materials, length and size of pipe, water meter location, fixture unit demands,
location and type of backflow prevention devices.
• Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands.
• Additional piping plans for roof/deck drains, condensate, medical gas, etc.
• Plumbing fixture schedule for all plumbing equipment.
• Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc.
ELECTRICAL PLANS: Please provide the following information on the electrical plans.
• Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado
State Licensed Engineer stamped plans.
• Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency
exit signs and lighting, and panel location.
• Diagram showing service entrance, conduit/wire size, main disconnect size, grounding
electrode/conductor size, feeder conduit/wire size, transformers and generators.
• Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc.
Contacts
Building Plan Review
Description of Work: new construction of preschool
Bin #: On top shelf
Location Address: 44761 Hwy 6 & 24
NEW CASTLE, CO
General Information
rCase Manager: David Bartholomew
Plan Case Number: BLDG -3-15-8258
Parcel: 212335200098
Application Date: 03 18)2015
Owner: NEW CREATION CI IURCII
Applicant: NEW CREATION CI IURCI-I
Applicant Phone: Email:
Building
tJ
Engineered Foundation
Dr- v way Permit
n 1,
JSu eyed Site Plan
eptic Permit and Setbacks
i
Ghacii
rade/Topography 30%
Residential Plan Review List
Minimum Application Questionnare
1
lj Property Line Setbacks
PlanninglZoninq
1f.[ 30ft Stream Setbacks
I U ' Flood Plain
__D_L___. uilding height
Zoning Sign -off
____Road Impact Fees
HOA/DRC Approval
bdiision Plat Notes G <de/Topography 40%
e Department Review Planning Issues i 1410 All ?Z4r
Valuation Determination/Fees ubdivision Plat
d Line Plans/Stamps/Sticker General Comments:
Att 1 Conditions
V
oppli tion Signed
Reviewer To Sign Application
arcel/Schedule No.
III' 11240# Snowload Letter - Manu. Homes
Soils Report
Wednesday, April 29, 2015
ViltaA/40-zi, 4 v 5rEi
f
1 1 085 o7.06 -1 oaf, 709