HomeMy WebLinkAboutApplication - PermitGarfif!ld County No. ltDi-33 I Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office 945-8212 Inspection Line 384-5003 Job Address: 1215 North Cedar Springs Ranch rd, Rifle Locality:. ____ C"'-e .... d_a_r S_,p~....r_in""'gs ___ Ra"'-n-'c .... h..,.S_u_bd_A_m_..;;_en....:d..:.., _P_ar_ce_I_AI_24 .... 0...;.3_-0_2_4-_0_0-_0_70 ___ _ Use of Building: Owner: Contractor: Amount of Permit: septic Total $1,096.84 $150.00 $1,246.84 s/f dwelling on crawl space w/cov patio Wildman, Jane Dave Lowrey Date: clerk: ~UU .JOf ---~~~.~~------ GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8~" Street, Suite 401, Glenwo-od Springs, CO 81601 Phone: 970·945-8212 I Fax: 970-384-3470 I Inspection Line: 970--384-5003 Permit No: -l\I-':Offi_:_::).::_3 __ Parcel/Schedule No:Q?, lf1J3-tJ;;{tf -:-06-Q] () 1 2 3 4 5 Ei 7 8 9 Garage: 0 10 0 ll 12 Special Conditions: 0. 0 NOTICE Single Doub~e 0 A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO, TillS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITIILN 180 DAYS,-OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FORA PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI-JE SAM:E TO BE '!RUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING TIHS 1YPE OF WORK WILL BE COMPLETED WITIIIN wHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE Almi0RI1Y TO V10I.ATE OR CANCEL TIIE PROVISIONS OF ANY OTHER STATE OR WCAL l.AW REGULATING CONSTRUCTION OR THE. PERFORMANCE OF CONSTRUCTION. £· a Alteration Addition 0 Move On-Site Sewage Disposal Carport: 0 Site Plan o Remove 0 0 Single Double Adjusted Valuations: S Plan Check Fee: 432-()<'{ I o "! t.. t'f I s-o G" Dated Permit Issued: Total Fee: OCC Group: (2( Const. Type: Zoning: Setbacks: ISDS No. & Fee: AGREEMENT PERMISSION IS HEREBY GRANTED TO TIIE APPUCANT AS OWNER CONfRACfOR ANI.i/OR THE AGENT OF TIIE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIF1CATIONS SUBMITIED TO AND REVIEWED BY TIIE BUILDING DEPARTMENT. IN CONSIDERATION OF TIIE ISSSUANCE OF THIS PERMIT, TIIE SIGNER. HEREBY AGREES TO COMPLY WITII ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUN1Y PURSUANT TO AUTHORITY GIVEN LN 30.28.201 CRS AS AMENDED. TIIE SIGNER FURTIIER AGREES TIIAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN TIIE LCOATION, ERECTION, CONSTRUCTION, AND USE ~'.>F"TI-IE ABOVE DESCRIBED STRUCTURE. TilE PERMIT MAY BE REVOKEp BY NOTICE FROM THE COUN1Y AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. TIIE ISSUANCE OF A PERMT BASED UPQN PLANS; SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENf TilE BlTILDlNG OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION ·OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. TIIE RESPONSI BILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFJCIALLY WITII THE ARTICTECT, DESIGNER. BUILDER, AND OWNER. COMMEN'IS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORI' OF THE OWNERS LNTEREST. ~ \(lV\ ~~fee I HEREBY ACKNO~DGE T!a(" I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE [INITIAL),~ ,0-l%-o..?r {)\"'· \\-uJ,-0'" c(. to4-b c~-\O~ $ 4SlJ.8~ . ~ .,_qd,.-~»Jcll-ro--J The following items are required by Garfield County for a final inspection: l. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A fmished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and fmished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a fmal inspection made; 8. A fmal inspection sign off by the Garfield County Road & Bridge Department for driveway · -msta:lJafion:;-wl:iereaiJiJfical:ile; aswelr as anyfinaf s1giiorfl:iytfie l'liebisirici, aiid!oisiaie · ·· -···· ··· Agencies where applicable. 9. If you will be connecting to a public water and/or sewer system, proof of the tap fees have been paid and the connections inspected by the service provider prior to issuance of a C.O. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****A CERTIFICATE OF OCCUPANCY MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupan~/"'.~~e issuance of a Certificate of Occupancy for the dwelling under building permit# -f-f.\->.V..t.)__,_-t'...:-:>=...:>=- :-~~ -1tl ildntaaL Signature Bpapp!icationoctober2006 ;o!nh 7 Date VALUATION FEE DETERMINATION Applicant Address Date ..,W~ild~m::.;::an~::-c:-..,--:::---:-:::-o---Subdivision 1215N. Cedar Springs Ranch Rd. Lot/Block -:1"-'o"'/3:'::1~/2::;0::;:0;:;7=======:....;....;.;..._ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation · Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation 576 sf sf sf sf X $74.68 576 sf sf X $4LOO sf X $33.68 sf X $18.00 576 sf X $9.00 192 sf X $24.00 sf X $12.00 Commercial sf X sf X sf X sf X sf X sf X CedarSprings IZa.v-d..~ Av.t.w:l..~o/ Parcel A Dave Lowrey 43,015.68 0.00 0.00 5,184.00 4,608.00 0.00 52,807.68 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has riot been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. · Please review this document to determine if you have enough information to design your project .and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with I decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, includingre-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown ori a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within thv.envelope. Yes. ___ _ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes J 3. Does the site plan include when applicable the location of the LS.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent p)XSperties), streams or water courses? y es_--".v __ _ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 5. 6. 7. 8. 9. 10. II. 12. 13. 14. / Yes ____ _ Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department jl( 625-8601. Yes __ V"---- Do the plans include a foundation plan indicating the size, location and spacing of all reiriforcin,g _$(eel in accordance with the IRC or per stamped engineered design? Yes. _ ___,V"--- Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and t)le clearances required between wood and earth? Yes. __ ,_v' ___ _ Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and ~s? Yes 1 Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wi!)d loads? Yes. __ _;,t/,__ __ _ Does the plan include a building section drawing indicating foundation, wall, floor, and roof constructi~ . Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof raL or joists or trusses? Yes l Does the building section drawing or other detail include the method of positive connection of all column~d beams? Yes. _______ _ Does the elevation plan .indicate the height of the building or proposed addition from the undisturbed ~de to the midpointbetween the ridge and eave of a gable or shed roof or the top of a flvYoof? (Building height measurement usually not to exceed 25 feet) Does the plan include any stove or zero clearance fireplace planned for installation including 3 15. 16. 17. 18. 19. 20. 21. 22. 23. make and moc)el and Colorado Phase II certifications or phase II EPA certification? Yes v' No ____ ~~~~~ Does the plan include a masonry fireplace including a fireplace section indicating design to comply with J;he IRC? Yes vi No ____________ __ Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes // . No _____ _ Does the plan include a window schedule or other verification that windows provide natural light and ven}ilation for al.l habitable rooms? Yes V No ____________ _ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify yafety glazing for these areas? Yes V No __________ _ Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on tJ;re plan? Yes . .../ No ------ Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenay.ts? Yes 11 L_ No ______ __ Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk dthe HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial!J!Odification of the plans. Yes v' No ____________ __ Will this be t}le only residential structure on the parcel? Yes ,L No Ifno-Explain: ____________ __ Have two (2Lplete sets of construction drawings been submitted with the application? Yes ~ 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long?/ Yes No ________ ~ 25. Have you designed or had this plan designed while considering building a,nd other constructimycode requirements? Yes v' No _____ _ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zoye district? Yes v/ No ______ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection /by the Garfield County Building Department? Yes 1.-- 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes J No ------ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building p~it? Yes c./ No ----- 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called ~o 384-5003. Yes No _______ -'- 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Y es ___ ->-L----- 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy ~he building? 5 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes. __ ~<---No _____ _ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you· as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No ______ _ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a buildinw6ermit application? Your attention in this is appreciated. Yes vr· No _______ _ 36. Do you know that the local fire district may require you to submit plans for their review of fire. safety issues? Yes No (please check with the building department about this requirement) 3 7. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? / Yes _ _:_v __ _ 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance 7Certificate of Occupancy? Yes _ _:_ __ _ Si ature of Owner Phone:17~-3 (c;' -O !If, (days); /() lr?/6 1 Date 970 -'!J 7& -OS 3.3 (evenings) ProjectName: Wdl~ cakA. ProjectAddress:/OZ/5 N-CedC?A 5~/~ Kd.~ {j) g/65° Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to. beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application maY be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, ffiC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 75PSF 8001 to 9000ft. 1 OOPSF 9001 to lOOOOft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofsR values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. · • Basement wall R-values are R-1 0 befow grade, R-19above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Comrnori ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant \)} l \ 0 I'VVtz--) Building ~gineered Foundation ~Driveway Permit ~ Lsurveyed Site Plan ~Septic Permit and Setbacks 7araderi'opography 30% ~ttach Residential Plan Review List ~inimum Application Questionnaire ~division Plat Notes 4Fire Department Review -t""'"' Dctermie,ioo!F= ed Line Plans/Stamps/Sticker tilAttach Conditions ~Application Signed V Plan Reviewer To Sign Application /Parcel/Schedule No. ~40# Snow load Letter-Manf. Hms. v/ Soils Report GENERAL NOTES: Date to-"31 -oJ PlanningfZoning _drroperty Line Setbacks . t/30ft Stream Setbacks ~oodPlain ~!ding Height _Lzoning Sign-off . ~oad Impact Fees --.,.L1foA!DRC Approval ~Graderi'opography 40% V Planning Issues ~ubdivision Plat Notes INSPECTION Will NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS ·BUILDING PERMIT GARFIELD COUNTY, COLORADO· Date lssued.J.~~1 ..... Zoned Area ............................... Permit No ... lO.l~ ........ .. AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. I . ...--;- Use :5 t ~).£111Vl4 (l>V) ("'m\ SfJ\f. \u~OD ~\1.0 Addressor Legal Description \d-r;, N. ();t\(\t"''S?W'l<:Jp ~UV\tYl '£tlr 'i-\f\( Owner h\\\(}1{/\\\l\, .\1::\V\C Contractor 't:nW. lt)W"<e\\ Setbacks FroDi Side Side Re·ar · This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD Date ~~~-()l By cH, IF PLACED OUTSID -COVER WITH CLEAR PLASTIC J' INSPECTION Will NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO· Date Issued.J.\~~1 ..... Zoned Area ............................... Permit No ... \Q.1::~ ........ .. AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not folly complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. I . ,--- Use :?) t C:W.f!lliVlC.j Q>ll\ ('(Dm\ sv=tct'-\).lr(m~ ~\(o Address or Legal Description )d, \';> \\l . Caltl'f' ~~Vl~$ 'e-UV\C VI '£0 1 I(_ \f.\( Owner b)\\( \\tl\\l {\ 1 ::.c:.W\C Contractor \:n\p. LC'>WW'\ Setbacks FroDi Side Side Rear· This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD Date n .. ~-()l· By b)f\'flMCt~ -M> IF PLACED OUTSID -COVER WITH CLEAR PLASTIC \01-"33 No. __ ~~~~----. Assessor's Parcel No. ~4.\13--D~lHj(J.\)1<) Date \\~{))- BUILDING PERMIT CAR Job Address ~S ~ Cbe)OP. £1~ roVlCn ~o~ tlflr Owner W\lclYOOD c .\(1 Vll1 Contractor !Jtl\JE l 0\})1tl:7~ Address BO'! \.CAY~ gltlt Address R)-3 ll\u~~· ~\flf Setbacks: Front Rear RH, ____ LH ____ Zoning ___ _ SJF 0HDt-uing C!lV\OCl\Ut:SFQCE w/cov ~~~ecTioNs Soils Test ..--=t·-..-;;-r~----- Footing J, ~Jif-!?'if_Jirm. Foundation ~-i!f:.oa= (f!J k Grout __________ _ Underground Plumbing-:----::---,.,---=--- Rough Plumbing £'-2~-o81{)id Framing 6-3-c:Jl!f~ Insulation k' jlj~og l{)1'v'\ Roofing 'l_..----s~-&<2' $?! Drywall /~ at?-08' ~ Gas Piping S.g 3-o8 tf}rA... NOTES Weatherproofing ·9' ;s;::-69 P .-!2/ij.,- Mechanical '7 2 .:.:-C/:? #f-t/- Eiectrical Rough (State) ,<{--'9'-CJ '6" Electrical Final (State) ?-2:-9 ~o J? ~ Final9'-?-&.3' /Checklist om leted? C?U Certificate Occupancy # ~~~~-==----- Date -;~~-u..---=---t--~....<~~-­ Septic System # -iil~!....:k...-------­ Date --'--'-""=--"~--=-----::oo--77'-1--- Other--------------- (continue on back) COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Permit No. /CJ 7::3::5 I have this day inspected this structure and these premises and found the following corrections needed: tt/A~(._ + /2GJCJ/( t'~,,tJrctf. /'ll(;c ~LAc g;, r .8tCr!./;;I/CJ LrXX: UJ;UL C:/(.ANCi'L~ ~for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When torrection(s) have been made, call for inspection at 970-384-5003. Date f# -// 20 0 8 Building Inspector C3~ a/~-----­ Phone (970) 945-8212 ~ COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at /;?5 d. Permit No. J 0 13 2 )~~~~~~~~~~ ~~~~~~~~~~~~ ~all for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date .5'-d-3 -oo 2o Building Inspector llik~ Phone (970)945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone(970)945~212 Job located at / 2.._/_s- Permit No. /cJ 7 :5.3 I have this day inspected this structure and these premises and found the following corrections needed: / . ;;;:?c;ll for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When ~rorrection(s) have been made, call for inspection at 970-384-5003. ' Date 9-1: 20 C7 5? Building ;Jl;pector ~ ~~ Phone (970) 945-8212 ' Jane Wildman 1215 N. Cedar Springs Ranch Rd Rifle, CO 81650 Building permit# 10733 ~tn-/1 ?~ (1 ~\. APPROVEu SUBJECT TO !KiTED ·~XCEPTIOJ::J-!:.·> fr: fi,~--SPECTIONr­ GARFlE.LD CCUNT\ BUILl;)lNG FPitRT~. ,.N'. .>ate 'f·'l:'V"' By ------0-~ -···--·~· F'XELI) Cc)PY NO INSPECTiON WiTHOIB~ 'rHIE!£ I'!.ANS ON Smi I would like to add an 8 foot by 24 foot porcJ1'l:g'the back ofllie previously approved house I am building in Rifle at the above address. A rough sketch of the addition is below. If you have any questions please call me at 970-319-0116. Jane Wildman ~\ = • lilF -_ ----- i i 'i i ' 1: §] §1 §] ,, ,, -u-1-~ lr'::> ,, 1 1 tre~'i I I ,. __ ::.._ ___ ~, Jane Wildman Cabin Cedar Springs Ranch Road Rifle Colorado 81650 September 05, 2007 Scale: 1 :96 1 "=8' HARTMANN ENGINEERING INC 1 266 Texas Avenue Grand Junction CO 81501 (970) 245-6200 September 05, 2007 Scale: 1:96 1"= 8'0" APPROVED SIIBJECf TO NOTED EXCEl'l'IONS & INSPECTIONS GARFIELD COUNTY BUILJ)ING DEI'ARThiENT Do .. /0-Jf .v1 By_M.L_ FiELD COllY NO INSI'l!CTION WITllOuf 'l'llll8E PLANS ON srl1! -of r:: i\'l .~'\·, '"(, "-: ~ ~ ;;~ ~ o~ u;Juod ·u ·os ~61 .m:uv;J ·u ·os gzg .uiV' H!:llll. 666! •.:g oiJ.ll'>iJk!<>:::> .NVUSJNilll,, crplJ. S.J..NV'dl-lO:? Nlg'V::> 33>10f!3H::> i .(jl-.L=:17/L '31'7:?5 NVld NOI..LVaNnO;:j .o .vi: " § w d _J "• ::) 8~ ~5 D n w I g~ \.) ~ ~~ U) \\ n~ ·-.... ,) \!) ~!8~ z ~~~ 1- ill~~ 0 §~~ 2 ••• ~~~ >' "''ftf~ ~ •• :r 1 ·h ·~~ ,. • <>"'I ~"1 WINDOW SCHEDULE SYMBOL SIZE R.O. SizE" = MFG. """"· TWiN 3'-o-x5'-0' HULL WTTH :2XS 75-1/:2WX60"H 1 0\VNER"S CHOICE B .3'-0?<5'-0" .36WX60"H "-· B'=Q"X4:-0" ""''.36~· *VERIFY RO. DIMENSIONS PER MFG. HEADERS: DOUBLE :2X4'S MAX . .38" DOUBLE :2X6'S MAX. 55" DOUBLE 2XB'S MAX. 75" FIREPLACE NOTE: :2 OWNER'S CHOICE. 1 ~SCHO!CE CABIN DESIGNED TO HEAT YEAR RCUND WITH THERMOSTAT CONTROLLED GAS FIREPLACE. FIREPLACE FRAMING SHALL BE DETERMINED BY MFG. OF THE FlREPLACE OF CHOICE, FIREPLACE OPTONS: 1. GAS FlREPLACE :2. DIRECT VENT FIREPLACE (NO CHIMNEY REQ'D.) .3. VENTLESS GAS FIREPLACE (NO CHIMNEY REQ'D.) BEDROOM :ll-~~ ~"71 ~ ~\1£),1'1 / LIVING ROOM BUNK ROOM * z.t cl_:ll _j z :s a._ el. 0 0 _j lL z ~ ~ ID \) @ lli-t y_- 9 ~=~ ~ \)~ ;:; ~ ® ~ <ll FIBERGLASS SHINGL-ES 18" OVERHANG ("TYPICAL----ttf RIDGE VENT 4" TRIM (TYPICAL-) ---1 RIGHT SIDE ELEVATION SCALE: 1/4"'=1'-0"' FRONT ELEVATION SCALE: 114"'=1'-0"' 18" OVERHANG (TYPICAL- PATTERNED Pl-YWOOD SIDING f----4" TRIM (TYPICAL-) 1. PJ.l. Gl.AZING IN DOORS AND IN WlNDOWS WITHIN 241NCHES Of DOORS MUST BE SlfETY GI.AZING. SEE 1142 2. E ll42 AND CODE FOR OTHER .'IREAS THAT REQUIRE SAFElY GlAZING. - U) ~ ~ ~ \) @ ill > ~ = l ~=~ \)~ RIDGE VENT-----, PATTERNED PLYWOOD SIDING --J.J+t OPEr<ATIONAL FOUNDATION VENTS LEFT SIDE ELEVATION SCALE: 114"=1'-0" a· POURED OR C.M.U. FOUNDATION WALL. REAR ELEVATION SCALE: 1/4"=1'-0" 18" OVERHANG (TYPICAL) 6"X6" P.T. POST 8"X16" C.M.U. PIEf<S OPTIONAL LATTICE HURRICANe CUPS AT .AU. RAFT"aRS; 3/e· SOFFIT PL. '"'-'<:XX:>' WITH SCREENED 1'X6' FRIEZE __ _) ENABl-ES 'THE USE OFeiSIDING ,ANCHOR VAPOR ATTIC KITCHEN (GLUE PRE~ENGINEERED RF TRUSSES HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION r ---Fl8ERGLA.$5 SHINGLES OVER 15~ FELT ON V2' SHEATHING -:#lb -#~ PORCH ""'CAL) ( .3-.2?<10" GIRDER, STAG>ER J.:mj!--B'X16'REINFORCED BLOCK PIER ~1 \ CRAWL SPACE ~;,;> SECTION 3/8"=1'-0" NOTE: -;:t-... F0011NS TO !<EST ON / UNDISTURBED SOIL AND BE WELL BELOW DEEPEST FI<OST PENAT!<A110N. ELECTRICAL LEGEND -* ----. ---... SWITCH -If!, .$WAY SWITCH = =ai ---· ~t @ DUPLEX CONVENIENCE OUTI...ET "WEA THS<: PROOF (.\VP) @-@G" DUPLEX CONVENIENCE OUit.ET "GROUND F.AULT (GFI) tt =€> =>OUTLET -9-CEIUNG MOUNTED UGHT RXTURE P-W.AU. MOUN7EO UGHT FlXTUI<E ©! RECESSED (CAN) WGHT FIXTURE ISM<><e-i SMOKE DETECTOR m E:XHAUST FAN WIUGHT ·~ f~ z =~ ...... ~ ~ ~~ qj TEl .. .EPHONE OUTLET @ 1VOU11-ET o<J EXTERIOR FLOOD UGHT " ~EDISPOSAL ~ GARAGE DOOR OA::NER W/UGHT = R..UORE$CENT: VNDER KITCHEN CASINET ·oVER 5AiH I<OOM MIRROR TWO TUBE FLUORESCENT LIGHT FIXTURE /I ,,, FOUR TUBE FLUORESCENT UGHT FIXTURE + FANW/UGHT n.. _j ~ ~ ~ rt ~ = } \- 0 9 ~~ Tt w ~ \)~ ;:,; _j ~ ® w SITE PLAN Lot A, Second Amended Cedar Springs Ranch Subdivison -<t---------------r-------------""~8"9c""2"5c'l~4c'~'E~-------------------------"'17~9~9".5~1~'----------------------------;-~ EastC€nWrl/16COmersec«on2 _ _ _ _ _ Aluminum Cap LS No. 31143 Set Js ~ SCALE: 1 "-200' Parcel A ~--~---~ / /\ \ / , 1 \._..--40.0' Access & Utility Easement / / _..-!, \ 1 / I I I 1 I I I 1 I \ I I \ \ / / \ \ f I I I / I \ \ I I I I I I \ 1 I I \ \ f I I 1 I ! I 1 ----' I \ I lJlQlilfJ2 Rebar&Cap@ LS#31143 1_ N 89"32'35" E I 1786.43' I I I I IVOTES 1.) THIS SURVEY WAS PREPARED WITHOUT THE BENEFiT OF A CURRENT TITLE COMMITMENT AND DOES NOT REPRESENT A TITLE SEARCH BY THIS SURVEYOR OR BOOKCLJFF SURVEY SERVICES, INC. OF THE PROPERTY SHOWN TO DETERMINE OWNERSHIP, COMPATIBILITY WITH ADJOINING PARCELS, OR EASEMENT OR ENCUMBRANCES OF RECORDS AFFECTING THIS PARCEL. 2.} THIS SITE PLAN DOES NOT REPRESENT A BOUNDARY, IMPROVEMENT OR IMPROVEMENT WCATIC!N CERTIFICATE SURVEY BY BOOK CLIFF SURVEY SERVICES, INC. OR ANY OF ITS ASSOCIATES. 3.) APPROXIMATE ELEVA110N OF THE SITE, BASED ON THE USGS HORSE MOUNTAIN QUAD, EQ(YILS 6300 FEET NG-VD 29. f--40. 0 Access & Utility Easement SURVEYOR'S STATEMENT Parcel Detail Page 1 of3 Garfield County Assessor/Treasurer Parcel Detail Information t\$§e§!ior!Ire!ctHtrerPmpert.YSei!reh I j\$sessor Subset Ouery: I Assesso_r_Sales Search C:!erk~Jseeorder_Reeeptim:LS_eMch · Basic Building_kharacteristi¢s I Thx_Information Parcel Detail I Value Detail ll_a_les Detail I Residential/Commercial Improvement Dt;Jail Land Detail I Photographs l Tax Area II Account Number II Parcel Number II Mill Levy I I o24 II R043730 II 240302400070 II 44.867 I Owner Name and Mailing Address jWILDMAN, JANE B I jmo B PITKIN AVE I jGLENWOOD SPRINGS, CO 81601 I Legal Description jSECT,TWN,RNG:2-7-93 DESC: A PARCEL I joF LAND IN THE S 112 SEC. 2 AKA jPARCEL A OF THE CEDAR SPRINGS jRANCH SUBDIVISION AMENDED jPRE:R246992 PRE:R247107 AND/THRU:T jTO:R247109 PRE:R007280 BK:969 jPG:941 BK:887 PG:170 BK:721 PG:423 JBK: 1250 PG:350 BK: 1192 PG:757 I jBK:1947 PG:233 RECPT:727397 BK:1909 I jPG:0868 RECPT:720439 BK:1871 I· jPG:0817 RECPT:712725 BK:1270 PG:508 I JRECPT:584791 BK:1228 PG:417 I JRECPT:575235 BK:1192 PG:757 I jRECPT:564979 BK:0895 PG:0117 I JBK:0826 PG:0499 I http://www.garcoact.comlassessor/parcel.asp?Parce!Number=240302400070 10117/2007 Pareel Detail Location Physical Address: IIRIFLE I Subdivision: I Land Acres: 1135.002 I Land Sq Ft: llo I Section II Township II Range I 2 II 7 II 93 I Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 85,44011 24,7801 I Improvements: II oil ol I Total: II 85,44011 24,780j Sale Date: 1112/6/2006 Sale Price: 11167,000 Basic Building Characteristics . Number of Residential io I Buildings: Number of Comm!lnd !o I Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type II Amount I I 2006 II Tax Payment: Whole II ($48.00)1 I 2006 II Tax Amount II $48.ool ThpofPa~ Ao$eo~~2LD;!til.PiJ.Be Se!!Ic:;hQpJjqJJS I IreiJ.~\JieLDiJ.t;!hiJ.$e~SeiJ.IGhQptiqn5 Cleric & Recorder Database Searc;h Options http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=240302400070 Page 2of3 10/17/2007 > .-~--=----11 I •' Jane Wildman Cabin Cedar Spring~ Ranch Road Rifle Colorado 81650 September 05, 2007 Scale: 1:96 1 "=8' HARTMANN ENGINEERING INC 1 266 Texas Avenue Grand Junction CO 81501 (970) 245-6200 September 05, 2007 Scale: 1 :96 1''= 8'0 11 APPROVED SUBJECT TO NOTED EXCEPTIONS & INSPECTIONS GARFIELD COUNTY BUILDING DEPARTMENt Date It;. J/-c/1 By _~!__ FIELDCOilV NO INSPicrtON WITUOuf 'l'lm81 PLANS ON Srfl .,.e of •' '· 1. Each house to have an open hole review when excavated by a qualified soils technician or the registered engineer in charge . The registered engineer of record may waive the inspection requirement. 2. Water control under houses with high water tables shall be designed by the engineer. These measures may include : 2 .1 The ground surface below the house shall be sloped and patterned for good drainage. 2 .2 A 4 mil visqueen or equal vapor barrier shall be installed on the e xc avated ground surface . 2.3 Adequate ventilation shall be provided to the crawl space tp keep it dry. 3 .0 All rebar placed in soil-formed e xcavation as forms shall have at least 3-inches of concrete covering. Rebar placed inside forms shall have at least 2-inches of concrete covering. All rebar shall be #4 unless otherwise specified on this drawing. 4.0 Footing concrete to be at least 2,000 psi compressive strength 5.0 Stem wall concrete shall be 3,000 psi compressive strength 6.0 Footings shall be 2'8 11 x 2'0 11 x 8 11 thick with a reinforced 8 11 x 16 11 concrete block pier at the center. 3 each* 4 longitudinal bars shall be 1mstall~ cont!nu~us ~rs or sp_l!ced with a 24 Inch lap, In spread tooting with 3 -Inch clearance to ground or 2-lnch to forms Footing and Stem Wall Section A-A' \ I I I I I Footing Type 8-8 ' Jane Wildman Residence 1215 North Cedar Springs R~nch Road Rifle Colorado 81650 September 4, 2007 Scale: 1:24, 1" == 1 /2' HARTMANN ENGINEERING INC 1266 Texas Avenue Grand Junction CO 81501 (970) 245-6200 September 4, 2007 --· ....... -_:-_-:.._-_-11 >. I Jane Wildman Cabin Cedar Spring~ Ranch Road Rifle Colorado 81650 September 05, 2007 Scale: 1:96 1 "=8' HARTMANN ENGINEERING INC 1266 Texas Avenue Grand Junction CO 81501 (970) 245-6200 September 05, 2007 Scale: 1:96 1"= 8'0" .,.-..\ -. ( , I I "-.-~! I { I l c (i .. I (~ L . ) ,.. ' /{ I • ' I ... 1 "/ ..... } ' ....-' ,__.,..\ ' I .--· J ~·...., ..,) BUILDING CODES CHANGE FROM CITY TO CITY, COUNTY TO COUNTY. THE SE PLANS SHOULD B E REVIEWED BY YOUR LOCAL BUILDING INSPECTOR B EFORE CONSTRUCTION B E G INS. 241 0 11 • POURED OR C .M .U. :------------------------------------------------------------ ' I ' ' ' I ' I I ' I : ' I : CRAWLSPACE 5 '8 " 8 " X 16 ' REINFORCED BLOCK PIER (TYPICAL) (@ 2 '-8' X 2 '-0' X e · DEEP ~PIER FOOTING (TYPICAL) 5 '8" BEAM POCKET FILL CELLS B ENEAJ!:'i .•• i j . ! : GIRDER 3-2X10'S ST.AGGE R. JOINTS -----------------------------, j / ' I I ' I : ' I I ' I ' I I I I I I I ' I I ' I I I I I I I I I I I I .... --------+ : , ... ---- 1' 0 I 5 · a·: !----;-uLtfl '' 'I lo II I 0 :' ----~-:r.:-::: ____ 1 : , I I 1 ---- 1 ...................... 1 '--------- : ' : I ! I ' ' I I : I I FOOTING SCHEDULE : I i--·-·--· S Y M BOL SIZE @ GENERAL NOTES: 1. FOUNDATION DESI(ZI'J IS BASED ON ASSUI"'ED-SG>Ib--- ·----aEAJ:IING CAPACITY OF 2,000 P.S .F. IT SHALL BE THE J:IESPONSIB ILITY OF THI' OWNI'R/OJ:I CONTJ:IACTOR TO VERIFY SOIL BEARING VALUE AND CONSULT A S TRUCTUJ:IAL ENGINEER IF EXISTING CONDITIO N S DO NOT MEET OJ:/ EXCEED THIS VALUE. ' 2 . FIELD-POURED CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S .I. ~ 213 DAYS. 3. SHOP-FORMED CONCRI'TI' SHALL DEVELOP A MINIMUM COMPRESSIVE S TRENGTH OF 4,000 P.S.I. ~ 213 DAYS. 4 . ALL CONCRETE MASONRY UNITS SHALL BE EQUAL TO ASTM C90-66T-GRADE "A'. 5 . MORTAR SHALL 81' EQUAL TO TYPE 'M'. REINFORCEMENT -e:-wF!ERE-;APPLIC'ASCE. T HE FOL LOWING STANDARD SPECIFICATIONS (LATEST EDITION (REVISION) SHALL BE USED: A STRUCTURAL STEEL: AMERICAN INSTITUTE OF STEEL CONSTRUCTION (A.I.S.C.) 8 . MASONRY: NATIONAL CONCRETE MASONRY ASSOCIATION (N.C.MA) C . CONCRETE: AMEJ:IIGAN CON CRETE INSTITIJTE (A.C.I.) CONCRETE REINF. STEEL INSTITUTE (C.R.S.I.) i i L . D . WOOD CONSTRUCTION: NATIONAL LUMBER HANUFACTUREORS ASSOC. (N .L .M A) 7. ALTHOUGH eve RY REASONABLE EFFORT HAS BEEN MADE TO A V O ID ERRORS, O M ISSIONS, AND M ISTAKES. THE CONTJ:IACTOR AND/OR CUENT SHALL VERIFY .AU. COND ITlONS , DIMENSION S. DETAJI..S, AND SPECIFICATIONS. THE DESIC:>NER W IL L NOT 81' LIABLE FOR HUMAN ERROR AFTER CONSTRUCTION BEG INS. ________ T ________ I 1 i OPER.A"riiONAL F cPUNDA I j j I I I j i I i j j __ j e· QEEP X 1ej' WIDE GPNTIN!etf'S~ i ---J---I : I I I ' I I I ' I ' I I I I : I I I I ' I ' -------------· ! REINFORCEd> FOOTING ! 0 I ! ! 1 i i i I I 2 ' X 8 ' P .T . F'OR.CH FLOOR JOIST • i i i i i r-<D' j4· O .C. USING 2X P .T . DECKING 0 j . j j j I I I 1 j I i j j ! ! ! (.n j i i i j . ! I ! '-V ~~· [IIi ~-:~~<DOTI!2'-0;~~~!DEE6.AL~1:® 1 ~I ! 1 8 'X 16'R.EINFORCED L1 BLOCK PIER (TYPICAL) ! I ! i i i ---L---_____ J ! ! ,------L------, I ~------------1 ,-------------; : I I ! ! : ! : ! : : : : ! e=t. ,, :--.:·~ I 1 ! : j 1::1hij : 1 2 P .T .-2X10'S ! ;,-;:$,·' j _ -·-__ -·-·-·-·L ! : ,'1-.~.(, := t= =:=·=:=.~ = =·=:=:~:=f=: h•...t:.t!l ' =:=!=·=·~:=:=:=:=·=:=.=:=:=:=:=~= ~l =:..L:=:-=·-·-·-·-·-·-·-·-·:-I I I I I --! I I I 1 I I '---------~ L-----------· a· a · ~----+ -:.;---' 8 ' o · ------8 ' o · = ~i at tt: ·~ z i~ =~ ~ ~= Ie~ {l_ -z U) >-z 0 ~ ~ [ -0 I ~ lJ u ~ z ID ~ @ 0 w .t: w -.!!' ~ -~ z . o~ ~ -G --rl -' w ~ II I ~ lJ ~ ~ 0 ill _J ~ eB lL U) WINDOW SCHEDULE SYMBOL SIZE R.O. SIZE"' NO. MFG. I<EQ'O. (~ TWIN 3 '-0"X5'-0" 75-112"WX60"H 1 OWNEI<'S CHOICE MULL WITH 2XS (B) .3'-0"XS'-0" .36''WX60"H <er -f-,3';;;;Q"X4'-0"-~.36 '~ *VERIFY R.O. DIMENSIONS PER MFG. HEADERS: DOUBLE 2X4'S MAX. 38" DOUBLE 2X6'S MAX. 55" DOUBLE 2X8'S MAX. 75" FIREPLACE NOTE: 2 OWNEI<'S CHOICE 1 OWNEI<'S CHOICE CABIN DESIGNED TO HEAT YEAR ROUND WITH THERMOSTAT CONTROLLED GAS FIREPLACE. FIREPLACE FRAMING SHALL BE DETERMINED BY MFG. OF THE FIREPLACE OF CHOICE. FIREPLACE OPTIONS: 1. GAS FIREPLACE 2. DIRECT VENT FIREPLACE (NO CHIMNEY REQ'D.) .3. VENTLESS GAS FIREPLACE (NO CHIMNEY REQ'D.) ~ I <{) ;-.- ~ STAIR LOCATION DETERMINED BY F INISH GRADE - , ___ N en ~ ' ~6 .- N ~ ~ t . .- in l ·----~---~- 24'0" g · ,,. -=- (,· .... \•) r '-"" -'-"' I I 8 ' o· ~I : = . \ 5 '10-V2'l ;l ~ • I \}1 : (f) (U J I b in _i 1-r - 1: .. b 0 .- ',. _i (1 ~ (f) : 0 ~ N ~ U'l ~· _j I ~ I ---------------------------------,------------------------------------r ----------------------------------·r z ~ {l ri 0 0 _j lL - (j) >-z & [ ~ 0 I u IJ ~ z ~ ~ ID @ w +-.s:: w-.21 )/_-~ . ~=~ 0 I 'li ~ u~ r- ill _j ~ lf) RIDGE VENT --------'\. ------ FIBEJ<GLASS SHINGLES RIDGE VENT ----.... 4" TRIM (TYPICAL) ---l 6112 f--6 "X6" P.T. POST DO ~~-PATTERNED PLYWOOD SIDING t----4" TRIM (TYPICAL) rltt) ?J7 1. PJ.l GLAZING IN DOORS Ai'JD IN WINDOWS WITHIN 241NCHES OF DOORS MUST BE SAFETY GLAZJNG. SEE #42 1 SEE f.42 AND CODE FOR OniER AREAS llMT REQUIRE SAFETY GLAZING. ~ ~ c=J OPERATIONAL FOUNDATION VENTS !]~~~~~=~~~~~~::~::::::~~==r RIGHT SIDE ELEVATION ~~ --- SCALE: 1/4"=1'-0" = ~~ ~f tt ~~ rljfll =~ "-= IC~ 8 "FAC~----;_~~~~--~----~~~~~------~--~--~-~----~------~rnri 6 • FF<.I EZE _ _j_;r', I.': .. :m>n· ':T"r.'"iTT liR$i=i=~t ',r;mm'TT'T"_ .'T""1 .. r_; rl, -n"'T'Ttn ~ :. .. 4 " TRIM (TYPICAL) ---~ RIDGE VENT ----. PATTERNED PLYWOOD SIDING -----+.._._._ ~r-rr.,....,...,.-rr-~1-8" CHIM. CAP TF<.IM 8 " POURED 01< C .M .U. '" , ,, REAR ELEVATION SCALE: 1/4"=1'-0" 18" OVERHANG (TYPICAL) t---6"X6" P.T. POST :.:',:;5~,~~~-$:~-~em?{f A~r~:~~!E;:·' .. ·.· ·~~b~~u,~er!~h~Wf~~~~~~~:{: · withdut dqcun;:~nted..'per·mi$si·ori ': , . f.rorn ·their ,:creator; , . ( ·:-. ·-.·• ;, ... : .. . . f.L.....L..J....J....L.~cz::::::~-W..J...!...J...Lu..J....I....l....U...J...Lu...J....I....l....J...J..·.L· .~-T.,., ~-...J.U...LL.LLLLJ~~~mm~ .;r.~ ~ 8 "X16" C.M.U . PIERS LEFTSIDEOELEv A TIO~.____ OPTIONAL LATTICE SCALE: 1/4"=1'-0" lfl >-z ~ [ 0 0 z 5 - HURRICANE CLIPS AT ALL RAFTERS METAL DRIP EDGE 3 /8' SOFFIT PL WITH SCREENED VENTS 1"X6' FF<IEZE -----' ENABLES THE USE OF8'S IDING ANCHOR 60L T __,....,,., .. , (TYPICAL) FINISH (GLUE It NAIL) -+-+--, @16'0.C . BRIDGING (lYPICAL) ATTIC \ '"~-' ---------1 W.H .~ ' ' ' : ' PRE-ENGINEERED RF TRUSSES HAVE ENGINEERING FOR INSPECTOR KITCHEN D AT TIME OF FRAME INSPECTION FIBEF<GLASS SHINGLES OVEI< 15# r----FELT ON 112' SHEATHING 'tilt, -#~ DOUBLE 2"X10' BEAM 6"X6' P .T. POST ----1 ~'llo ~,._) POI<CH DOUBLE P .T . 2"X10' HEADEr< r----P .T. 2"X10' HEADEr< P .T. 2"X6" DECKING P .T . 2"><2' LEDGE!< P .T . ::2'X6' PLATE , 3-2"X10" GII<DEI<, STAGE!< .JOIN!rS : BRIDGING (TYPICAL) ( FLOOR JOIST OVERLAP 1 t----8"X16' F<EINFOI<CED BLOCK PIEI< ~ \ CRAWL SPACE ~;,) P .T . 2"X2' LEDGEr< SEAM IN 8'-0' SIDING V APOR BARRIER ~'f ~1 I OPTIONAL WATER HEATER LOCATION FOOTING (SEE FOUNDATION PLAN) SECTION 3/8 "= 1'-0" ASSUMED FINISH GRADE NOTE: -;:t ....... FOOTING TO REST ON / UNDISTURBED SOIL AND BE WELL BELOW DEEPEST FROST PENATRATION. - ELECTRICAL LEGEND e--::$------SWITCH ~ .3 WAY SWITCH ~e ----~~ ~=- €) DUPL..EX CONVENIENCE OUTLET @wP €)GF1 DUPL..EX CONVENIENCE OUTLET WEA THE I< PROOF (\VP) "GROUND FAULT (GFI) tt :no@ 2200UTLET -9-CEILING MOUNTED LIGHT FIXTURE P-WALL MOUNTED LIGHT FIXTURE 0 RECESSED (CAN) LIGHT FIXTURE I SMOo<el SMOKE DETECTOR w EXHAUST FAN W/LIGHT ·~ r~ z =R ~= 5 ~~ ~ TELEPHONE OUTLET @ IV OUTLET o<] EXTEI<IOI< FLOOD LIGHT g GARBAGE DISPOSAL ~ G,AR,A.GE DOOR OPENER WILIGHT FLUORESCENT: "UNDER KITCHEN CABINET "OVER BATH ROOM MIRROR " alj TWO TUBE FLUORESCENT LIGHT FIXTURE ll ~II FOUR TUBE FLUORESCENT LIGHT FIXTURE ) ' =--.J FAN W /LIGHT ...__. G Q_ - \f) >- _} ~ ~ r: ~ 0 I l) ~ z m ~ -rf_ @ w 1 \---w -Ill '),/_ -i b ~ ! 8 0 I w 'ii I w ~ l) ' .- _} ~ w ~ SITE PLAN Lot A, Second Amended Cedar Springs Ranch Subdivison f'--------r-------J:.N'!...2,8!:;9!,;;'~2~5~'1t4;t.':;_' E!::_ _____________ .!,1~7:..;9~9~ . .,Sw1~'-------------~-i~ East Center 1/16 Comer Section 2 ______ ~ Aluminum Cap LS No. 31143 Set Parcel A /---..... I ' I /\ I / 1 1 \.----40.0' Access & Utility Easement I I ___.,)-\ I I \ I I / \ \ I I \ \ I I \ \ I I \ \ I I \ I / I I I I I I I I I I I I I I I \ 1 I I \ \ I I \ \ I f I 1 I I \ \ ___ __} I \ \ ~. -~ I :._'1> I "~ I 'I<Y I I SCALE: 1 "=200' NOTE: THIS PARCEL IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS AND EASEMENTS OF RECORD OR IN PLACE. I I I I LEGEND Rebar& Cap@ LS#31143 N 89'32'35" E 1786.43' I I NOTES 1.) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A CURRENT TITLE COMMITMENT AND DOES NOT REPRESENT A TITLE SEARCH BY TillS SURVEYOR OR BOOK CLIFF SURVEY SERVICES, INC. OF THE PROPERTY SHOWN TO DETERMINE OWNERSHIP, COMPATIBILITY WITH ADJOINING PARCELS. OR EASEMENT OR ENCUMBRANCES OF RECORDS AFFECTING TillS PARCEL. 2.) THIS SITE PLAN DOES NOT REPRESENT A BOUNDARY, IMPROVEMENT OR IMPROVEMENT LOCATION CERTIFICATE SURVEY BY BOOK CLIFF SURVEY SERVICES; INC. OR ANY OF ITS ASSOCIATES. 3.} APPROXIMATE ELEVATION OF THE SITE, BASED ON THE USGS HORSE MOUNTAIN QUAD, EQUALS 6300 FEET NGVD 29. ~I I I --40.0 Access & Utility Easement SURVEYOR'S STATEMENT PROJECT NO. 07193-<>1 SHEET 1 "