Loading...
HomeMy WebLinkAboutApplication-PermitPermit Card 1 Garfield County Building and Planning Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone: (970)945-8212 Fax: (970)384-3470 POST ON SITE Permit NO. B L R E -8 1 0- 1 12 5 Permit Type: Residential Building Work Classification: Addition issue Date: 9/7/2010 Expires: 03/06/2011 AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Residential Building Parcel #:217719100499 Owner's Name: James Meyer Job Address: 1212 CR 321 RIFLE, CO Contractor(s) Phone Primary Contractor Inspection Scheduling Code Owner's Phone: 970-625-2045 Total Square Feet: 2100 Work Description: adding a cover patios N Inspection IVR Comments Pass Date Footers 106 Foundation Walls 110 >121),/, .2.-V-1 Framing 115 (i < Drywall 120' Final 126. t'f 'yiI_› 1 - ,`? ../-//1/ Misc 136,; Insulation 160'', Grout 175 Mechanical 405 UG Plumbing . 605: Rough Plumbing 610 Gas r 620 ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For Inspections Call: 1-888-868-5306 Project Address Garfield County Building & Planning Department 108 81h Street Suite 401 Glenwood Springs, CO 81601 - Phone: (970)945-8212 Fax: (970)384-3470 Parcel No. Permit NO; BL erm;t Type:.' Residential Bi ildin Work Classification Addition; Peimit Status Active Issue Date: 917/2010 Expires: 03/06/2011 Subdivision Section Township Range 1212 CR 321 RIFLE, CO Owner Information 217719100499 Address Phone Cell James Meyer CO 970-625-2045 Contractor(s) Phone Primary Contractor Proposed Construction / Details adding a cover patios FEES DUE Fee Amount Penalty Fee $421.55 Plan Check Fee $274.01 Residential Building Fee $421.55 Total: $1,117.11 FEES PAID Inv Total Paytype Amt Paid Amt Due Inv # BLRE-8-10-20485 $ 1,117.11 Credit Card Credit Card $999.30 $117.81 $ 0.00 Required Inspections: For Inspections call : 1(888)868-5306 Inspection IVR See Permit Record Building Department Copy Tuesday, September 7, 2010 2 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 888-868-5306 wdww.garfield-countv.com 1 Parcel No: (this information is available at the assessors office 970-945-9134) -1(41-00 i00 cl/ 2 Job Address: (if an address has not been assigned, please provide Cr, Hwy Stree e & City) or and legal description /,.- / G Lb ,, A/71 R .! 3 , / -Arlt 3 Lot No: tC-?c e'0 et) /9 i Block 7-7,.S No:Su d./ Exemption: , 93 4) d Pm 4 Owner: (property owner) / 4-.n 5 Mere'& Mailing Address /I' 1 rL / l fi u A I )1 P : Y 7e •-4,.2 3-- AC/5— Alt Ph; ? re -3/9 --55 2 5 Contractor: /4 F Mailing Address: Mailing Address: Ph: Ph: Alt Ph: Alt Ph: 6 Architect / Engineer: Nfi ( 7 Sq. Ft. of Building: A}/ Sq. Ft. or Acres of Lot: • j Height: ta t. No. of Floors: 8 Use of Building: it)/ 4, tet" 5l 1E rci M ILY 9 Describe Work: �'o1..)0Pe1) I' 1-.f4 10 Class of Work: o New o Alteration r — dition I1 Garage: ,/4- o n Attached o Detached Septic: N/4,_ 4) .J - ❑ ISDS o Community 12 Driveway Permit: 1/e T X (fl fl3 f c Owners valuation of Work: $ l�� r,Fa Authority. This application for a Building Permit must letter of authority, signed by the Owner, must A Building Permit cannot be issued without NOTICE be signed by the Owner of the property, de cribed above, or an authorized agent. If the signature below is not that of the Owner, a separate be provided with this Application. proof of legal and adequate access to the property for purposes of inspections by the Building Department. (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or State Wastewater Discharge Permit. if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 CERTIFICATION the information contained above is true and correct 1 understand that the Building Department accepts the Application, along with the plans my behalf (submittals), based upon my certification as to accuracy. of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on agree that land my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building (County Regulation(s)). 1 acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, described above, are not in compliance with County Regulation(s) or any other applicable law. to enter the property, described above, to inspect the work. 1 further acknowledge that the issuance of the Building Permit does not prevent the errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structures) or facility(ies) if such is in violation of the work by the Building. Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions for compliance with federal, state and local taws and County Regulations rest with me and my authorised agents, including without AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: Letral Access, Other Permits, Multiple separate permits may be required: County Highway/ Road Access or a Void Permit, A Building Permit becomes null and void days after commencement. 1 hereby certify that 1 have read this Application and that and specifications and other data submitted by me or on Assuming completeness of the submittals and approval the submittals reviewed by the. Building Department. In consideration of the issuance of the Building Permit,1 Code, ISDS regulations and applicable land use regulations construction or use oldie structure(s) and facilitylies), I hereby grant permission to the Building Department Building Official from: (1) requiring the correction of of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections or discrepancies. As the Owner, I acknowledge that responsibility limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ OWNERS SIGNATURE • lei,/ / Kr / DATE —^ 9 >^-- /0 Plan ( --5o40 )3P q -6-r0 STAFF USE ONLY He f sac q :30 Special Conditions: Adjusted Valuation: 27 600 °° Plan Check Fee: 274i.o1` Permit Fee: yz/.5 Manu home Fee: Misc Fees: itsP .92-4 ;5- ISDS Fee: To a1 Fees: Fees Paid: Balance Due: BP No & Issue Date: MSPS No & Issued Date: ----� / j/ 7. `� U 1-`$1 ,,9 99 3.6 -fl- 5.,___. Setbacks: t ' J 5 1 a �ikk4ki OCC Group: i�6 Const Type: `Zoning: BLDG DEPT: /00 PLNG DEP 4 7' /j 1 ' 41'044. u.4-' 4'ATE APPROVAL DATE APPROVAL 1 Building Plan Review Description of Work: adding a cover patios Bin #: Location Address: 1212 CR 321 RIFLE, CO General Information Contacts Case Manager: David Bartholomew Plan Case Number: BLDG -8-I0-6569 Parcel: 217719100499 Application Date: 08/30/2010 Owner: James Meyer Applicant: James Meyer Applicant Phone: 970-625.2045 Email: Building X74 Engineered Foundation /Y.4 Driveway Permit Surveyed Site Plan Septic Permit and Setbacks Grade/Topography 30% Attach Residential Pian Review List Minimum Application Questionnare -/// Subdivision Plat Notes 1/7f1 Fire Department Review Valuation Determination/Fees Red Line Plans/Stamps/Sticker Attach Conditions Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building height r` J Zoning Sign off ifr �r Road Impact Fees HOAIDRC Approval Grade/Topography 40% Planning Issues Subdivision Plat General Comments: VA/Ui4P"/ r 2-7 (oo. Application Signed geviewn-Pee '` Z71-/, C/ Plan Reviewer To Sign Application Pe1141 if 'Pe 14 Z 1, 55 Parcel/Schedule No. penA i bi .ree ., iit 7.... I . C5 (z.A. pefiv)i- Pee) /um rbt 1 / 1 1 7, 1 ? 40# Snowload Letter - Manu. Homes y ' /414,1 r pA ` eA r ( 1 7 8/ N/4 Soils Report ,Due 1 9 99. go Applicant Address Date VALUATION FEE DETERMINATION James Meyer 1212 CA 321 Rifle 9/3/2010 Subdivision Lot/Block Contractor Finished (Livable Area): Main sq.ft Upper sq.ft Lower sq.ft Other sq.ft X $74.68 Total Square Feet 0 sq.ft Valuation Basement: Unfinished Conversion of Unfinished to Finished Total Valuation Garage/Storage (wood framed) Carport: Total Valuation Crawl Space Total Valuation Decks/ Patios/Porches Covered Open exj5'T/N y Total Valuation GoueYMiiMci to 2300 dao Type of Construction: Occupancy: Valuation Total Valuation sq.ft X $41.00 sq.ft X $33.68 sq.ftX $18.00 sq.ft X $12.00 sq,ft X $9.00 sq.ft X $24.00 sq.ft X- $12.00 N/A N/A Owner 0.00 0.00 0.00 0.00 2 5 00 911( )2 oo P- 557200:004 ,604 D. 06 Commercial sf X sf X sf X sf X sf X sf X 0.00 `55;200:00— 2 6 0°, 00 FEE ESTIMATE FOR S/F STICK BUILT HOMES (ALL FEES ARE ESTIMATES UNTIL FINAL FLANS ARE REVIEWED) Applicant: -`l am 5 Al /e /e Job Address: 12/ E e 6 , rit Rh/ / Subd-Lot/block: -6'C it04) /9 C 7-6 5 / R 9 to / 6.-- i m FINISHED LIVING SPACE: - 4— sf X 74.68= UNFINISHED BASEMENT: 4- sf X 41.00= CRAWL SPACE: 474 sf X 9.00= GARAGE: 1\)/4 sf X 18.00= UNCOVERED PATIO/DECK: sf X 12.00= COVERED PATIO/DECK: MISC: MISC: 7&-'0 sf X 24.00= 5-01400 -4)4L TOTAL VALUATION: 0 1-400 THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: SEPTIC= PERMIT: PERC: 611v171)— �%f • Permit Na G ARFIELD COUNTY BUILDING PERMIT APPLICATION f 0A 8" Street, Suite 201. Glenwood Springs„ CO 81601 4b06sr: 970-9454212 / Fa e: 970-384-3.470 / Inspection Line: 970-384-5003�)(I) �( 1 — 0 ip _ C �11 q Parcel/Schedule No: an"' 1 `i 1 AGREEMENT PERMISSION is HEREBY GRANTED TO T'}IL APPLICANT AS OWN ER. CONTRACTOR AIYDIOR THE AGENT OF THE. CONTRACTOR OR OWNER TO CONSTRUCT THE STR OCTUR E AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPAR TMBNT, IN CONSIDERATION OF THE 1SSSUANCE OR THIS PERMIT, THE SIGNER.. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO ALMICIRITY IVL74 174 16.2&251 CRS AS AMKND£D. no. SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE L.COATION, ERECEION, CONSTRUC r1ON, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PLR MT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PLRMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT TIIE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE {OKRBC1ION OF ERRORS IN SAID PIANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION RUNG CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE RCV1EW OF SUBMITTED PLANS AND SCDCIETCATIONS AND INSPECT -10M CONDUCTED THEREAFTER DOES NOT CSNSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLIT1ES BY CARFI€1D COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIFS. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRt1C17ON RUTS SPECIFTCLALLY WITH THE ARTICTECT. DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. GuloraD10 1 HEREBY ACKNOWLEDGE THAT 1IIA%;RECDANDtem AND Tilt AGREEMENT ABOVE {IN ', . 13:19 (Mk ,)C? ` Job Addressiaztioi "lel Tem iii t"i "' P'`JUJW� j 1 1 r lj� %1� t'�l 1 Lot No: Block No: bd. / Exemption: • �.iiJ 2 Chvner: .,}nm . 2 •••610Ste' Addres-(1'.--: 1 a l r - C V 3) ! � P L e62, 66 3r"F Wk Ph: galContrac�r 1 k S ire +D!`1i7 P 77 Lie. No. Alih' n n er: t rrssr 1)0 Ph: Lic. NO 3 Sq. FL of Building: f, s 4.li OE it .� Sq. FL of c�.C_�..J fleighl:l �!! ". No. of Floors: l+ ►.+, tisroCBnildillg; ��e-`y fG� .• • • V,+ Describe Work: 374I t7V141 P ialN Ca' 4+ tL4 '� . r!'4 u '' �' 8 Class of Work: �0 New ❑ Alteration o Remove ❑ Addition 0 Move 9 Garage: o Single Carport: o Single Double 0 Double 10 `4Air D a Pelypii r, Jrf/3 )4 da -Site Sewage Disposal Site Plan t��J ' (Septic) 11 Valuation of Work: i�7� � Adjusted Valuations: S '3/ �[/J' )� 7,3/..,16 12 1 J Special Conditions: NOTICE, A SEPARATE ELECTRICAL PERMIT 15 REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES MULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 1S NOT COMMENCED WITHIN I9& DAYS, OR. FR CONSTKUC1TON OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF ISO DAYS AT ANY IIMEAFTER WORK ISCOMMENCED. 1 HEREBY CERUPY THAT I HAV& READ AND EXAMINED THIS APPLJCAT1DN AND KNOW ThK SAM 1 TO 55 TR1J ANI) CORRLCT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OR WORK WILL RE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE. OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAI. LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF I . ' U O I % 7—/,'C1b Plan Check Fee: I/ !2/3.78 Permit Fee: /g (P73 Total Fee: Dated Permit Issued: r,A1,3 1if5D r 32 31 /3 OCC Group: Coli NI.. Type: �� Zoning: - Setbacks: Maim. Home: 1!111A D_ & Fee: l'Ct . G� .�. 4 / `-T c ha 1 DA iti,,,„ 1110/16. ;II' + 1 i 116,71- s if. Ams,i ? LDG DEPT, PING. D ' -. : 23/05 V APPRO•ATE APPROVALIDA. AGREEMENT PERMISSION is HEREBY GRANTED TO T'}IL APPLICANT AS OWN ER. CONTRACTOR AIYDIOR THE AGENT OF THE. CONTRACTOR OR OWNER TO CONSTRUCT THE STR OCTUR E AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPAR TMBNT, IN CONSIDERATION OF THE 1SSSUANCE OR THIS PERMIT, THE SIGNER.. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO ALMICIRITY IVL74 174 16.2&251 CRS AS AMKND£D. no. SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE L.COATION, ERECEION, CONSTRUC r1ON, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PLR MT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PLRMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT TIIE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE {OKRBC1ION OF ERRORS IN SAID PIANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION RUNG CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE RCV1EW OF SUBMITTED PLANS AND SCDCIETCATIONS AND INSPECT -10M CONDUCTED THEREAFTER DOES NOT CSNSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLIT1ES BY CARFI€1D COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIFS. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRt1C17ON RUTS SPECIFTCLALLY WITH THE ARTICTECT. DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. GuloraD10 1 HEREBY ACKNOWLEDGE THAT 1IIA%;RECDANDtem AND Tilt AGREEMENT ABOVE {IN ', . 13:19 (Mk ,)C? ` Sep 02 2010 4:50PM HP LASERJET FAXMEYER 2 9706252045 )I4 / I)();14 Lr:tre') 177. <ye --- g- pa e 1 The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e, weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bappl icationdecember2OO7 L - 9 -/D DATE GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2009 IRC, and 2009 IECC. N/,4- 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes µ`Q'2 . Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 3-301 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes /U% /. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes /4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes A-5. Have you provided any RESOLUTIONS and/ or LAND USE P1RMIT(S) associated with this property? Yes if Yes please provide a COPY. No 2 7/1-6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes 71- 1. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes r`U 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 68rNo N-- 9, Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No 10. Do the plans include design Ioads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes N1. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters orjcists or trusses? Yes f/ 13. Does the building section drawing or other detail include the method of positive connection of all columns an cams? Yes N 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes / 15. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 3 lv44`I6. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No ��f}-17. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes Ny4, /74-- P/A_ 18. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes 19. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 20. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes 23. Will this be th my residential structure on the parcel? Yes No If no -Explain: +24. Have two (2) complete sets of construction drawings been submitted with the application? Yes *25. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes 4 26. Have you desi ed or had this plan designed while considering building and other construction code requirem ts? Yes 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes P�*28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes �' 29. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes N/A -- 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Pee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 888-868-53 Yes No 32. Are you aware that $50.00 re -in Yes requesting inspections on work that is not ready or not accessible will result in a ction fee? I 1k33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes 34. Are you aware that he Permit Application must be signed by the Owner or a written authority being given for an gent and that the party responsible for the project must comply with the IRC? Yes t 5 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The lice se number of the person performing the work will be required at time of applicable ins ction. Yes 36. Are you aware, that o the front of the Building Permit Application you will need to fill in the Parcel/Schedule mber for the lot you are applying for this permit on prior to submittal of a building pe application? Your attention in this is appreciated. Yes Ai/A-7. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) loirtDo you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes 39. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes tf-1--- 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes I hereby acknowie s ge that I have read, understand and answered these questions to the best of 'lity. Si•4".ture of Phone: $ (days); Project Name: Project Address: Date "P"--5- ; evenings) fri r ,e P4-1) o ('© u rZ /g9 -/ P-- eC ,t fib 3 �--J 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminregsfJun2010 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2009 IRC, IBC, IFGC, IMC, IPC, 2009 IECC. Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof! Not ground): 40PSF up to 7000ft. elevation. 50PSF 7001ft to 8000ft. 75PSF 8001 ft to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe. Termite infestation probability: None to slight. Wind speed: 90mph. Decay probability: None Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building official Ice shield under-layment required. Mean Annual temp: Variable Insulation: Windows/doors U=.35, Skylights U=.6, TBL 402.1.1, 2009 IECC. Minimum R -Values: • Ceilings/roofs R values are R-38 stick built structures. R38 log construction and steel rafter construction. • Walls R values are R-20 wood frame. See Table 402.2.5 2009 IECC for steel framing • Floors R -values are R-30 or enough to fill cavity. • Basement wall R -values are R-10 /13. • Slab perimeter R -values and depth is R-10/24in. • Crawl space wall R -value are R10/13. If floors over crawl space are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-20 insulation. Common ceiling/floor garage to house must have R-20. Take precautions to protect plumbing in these areas. 8