Loading...
HomeMy WebLinkAboutApplication - PermitGarfield County N 0. I 1.01-]-0 Building & Sanitation Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office 945-8212 . Inspection Line 384-5003 Job Address: 0066 Mid Valley Drive, New Castle Locality: 2179-124-00-509 Use of Building: addition to living room & add to bathroom Owner: Collin,s, Todd & Tina Contractor: Owner Amount of Permit: $845.54 Date: Clerk: ___,Jo....;_t U---1:""~\Q.__r __ GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8'h Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield~county.com Authority. This application for a Building Permit must be signed by the Owner of the property, authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Pcrrnit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate permits may be required: (I) State Electrical Permit, (2) Comlty ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway! Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Pennit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of ISO days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf(submittals), based upon my certification as to accuracy, AssUming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Pennit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land usc regulations (County Regulation(s)}. J acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or usc of the structure(s) and facility(ies), described aboVe, are not in compliance with County Regulation(s) or any other applicable law. J hereby grant pennission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Pennit does not prevent the Building Official from: (I) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or usc of the structure(s) or faci!ity(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Buiidi.ng Department do not constitute an acceptance ofresponsibi!ity or liability by the County of errors, omissions or discrepancies. As the Owner, l acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents. including without limitation my architect designer, engineer and! or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFJCA TION ABOVE: STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Mise Fees: 3 (,) 5'11 It 333 6~ S I 2 '-Jc;' p-rr ISDS Fee: Total Fees: Fees Paid: II~U,. ~ Balance Due: BP No & Issue Date: ISDS No & Issued Date: P' ff'1~ $'1 b}$).)3 l\0110 l.:lh lb'J·'Bt Setbacks: OCCGroup: ConstType: Zoning: :;:;~c BLDG DEPT: \l\v PLNGDEPT: Qh ~~ \,\ ~ \ '"') e cl\ b A._\ \\-\j-o1 . ow1 ' DATE APPRO ~1\ \ l DATE .. v v The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNERS SIGNATURE ~--DATE Bapplicationseptember2007 VALUATION FEE DETERMINATION Applicant Address Date Collins Subdivision -:'OS::0'::'66;:.:.M:':;:-id~V;-;a-;l;-le-y ~D:-r.-----..,.-..,.-Lot/Block ..:lc:l:..:fl:.::.3.:..:/2000:.::0.:._7 __________ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation 192 sf 192 sf sf sf X $74.68 384 sf 192 sf X $41.00 sf X $33.68 Commercial sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 sf X sf X sf X sf X sf X sf X Owner 28,677.12 7,872.00 0.00 0.00 0.00 0.00 36,549.12 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with I decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, flom·joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within ~~? envelope. Yes ·~f\ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes ,; /A; 3. Does the site plan include when applicable the location of the l.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent P-roperties), streams or water courses? Yes ';( 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 Yes ·)<_ I 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road . & Bridge Department stating one is not necessary? You can contact the Road & Bridge ~:~artmer1\625-s6oL 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes._~--- 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes lv' £\, 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ' . 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes ·£ l 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes._-+'----- II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes,_-1-"~---- 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes, __ ~~----- 13. Does the elevation plan .indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) y~ ~ . 14. Does the plan include any stove or zero clearance fireplace planned for installation including 3 make and model and Colorado Phase II certifications or phase II EPA certification? Yes No __ -!--:::_ __ _ 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? v Yes No __ ___:r_~ __ _ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes , No ___ ~---- 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes f< No _________ __ 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specity;afety glazing for these areas? Yes ~· No ______ _ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? x· Yes No --+---- 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No _______ _ 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial mo ification of the plans. Yes No -------- 22. Will this be e only residential structure on the parcel? Yes No Ifno-Explain: ________ _ 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes r 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft .. wide and 20ft. lon~_? r Yes 1 fL No ________ ___ 25. Have you designed or had this plan designed while considering building a_nd other construction code requirements? Yes (C 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes No __________ __ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by )he Garfield County Building Department? Yes · + No · 28. Do you understand that approval for design and/or construction changes are required prior to the appl.1_c~ion of these changes? Y es _____ .J::;:.i-"---- 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Pennit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pickup your buildingy;rmit? Y es ___ _L___.J._ ____ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes "f. No ___________ -'- 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes No __________ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes No __________ __ 5 33. 34. 35. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IJ Yes L: No ____________ _ Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes No ____________ _ Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building~rmit application? Your attention in this is appreciated. Yes l No _______ _ 36 .. Do you know that the local fire ~ict may require you to submit plans for their review of fire safety issues? Yes I . No (please check with the building department about this requirement) 37. 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes J" Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance$ Certificate of Occupancy? Yes j'J (<\ ' I hereby acknowledge that I have read, understand and answered these questions to the ~t of m~}lity .. z)~L ,11-6-o7 Sigh1ltllre0f Owner Date ___________ (evenings) Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first .position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 PLAN REVIEW CHECKLIST Applicant __ -~..C""'o""" _,_\ lJ\,~·,_,"'--2s __ Building -LLEngineered Foundation V Driveway Permit ~ >'S hv ~urveyed Site Plan f;y:(M.;_ ")O ' JC:k_septic Permit and Setbacks _lh_orade!Topography 30% ~tach Residential Plan Review List /Minimum Application Questionnaire -6,L_Subdivision Plat Notes -4--Fire Department Review ,,•"" Jv aluation Determination/Fees 4Red Line Plans/Stamps/Sticker _L\&Attach Conditions V Application Signed _L'Plan Reviewer To Sign Application ../ Parcel/Schedule No. -4-40# Snowload Letter-Manf. Hms. L Soils Report GENERAL NOTES: Date _ _,_\ \,_-_\,_'<,_,__~-'o'-1_,__ __ Planning/Zoning -t..L'Property Line Setbacks V 30ft Stream Setbacks ~oodPlain -tL'Building Height ~oning Sign-off _LRoad Impact Fees -l.LHOA/DRC Approval --t.LGrade!Topography 40% Jr1anning Issues __0ubdivision Plat Notes /OJ) J) {b/j;_<;. ~'( 7/1",]) )/.{-/~ :Yt~. rAJ-evv~ {'q ~ G ~ Jt y '/ PEIZJ~trr -Fl ;o??o R..re"jv-"-5fJ-v\ ""' Ff.-f-;,_.-,.s;~ (yV\.__ f\j p~-'-1 ..¢ JO)?o AaJ.;;;,,,;._.._ 0\A.. )~t-(}~ e v~ A'"'-J-f aYL5d<J.O!)q 4/C¥"Wf( · J)ve_ {i> ,A}o L-<l4 > "'-ik A~- :J?_""' Y\.1 0\ /«; x :J;;; c.""r'< G "'~ <>+-..LtL ~ 4-I#) I );, 111 ve """'-.{; :-.<4 } d"'e.c+• <:..-...) ) r-..s f~U.~.-f '"~ ?<.J rftu ;"" -f4 ,.A~ f;r'o .__)~4--s ~-.sa , I~J 19 AJ?r---+ 9s--:!t {b~J- fbCfk a;J ~e ~l> ({,;/~ /?6 ~2o12._ 879'~ f/CJ 7:? ·-;i Yl )L-JbJ- ,01-10 No. __ ~~~-------~ Assessor's Parcel No.~ \1'{-\~L\-\10-'309 Date \\-~.,CJ"3-- Bl.m .. DING PERMIT CARD Job Address~ ~\}J~\\f~ ~r~ lJ\Q-tsCLE Owner ~WViij6cici f\1V\a ' . AddressO~ k\(} VO\\EY bf ~~~~\f m-~ () \~ Contractor (jU-)\1\'ff" Address \ 1 Phone # \\ Setbacks: Front Rear ____ RH, ____ LH ____ Zoning ___ _ Odd TQ) UviV)Qratw..i' ba\\1\JCJ~'M INsPecTioNs Soils Test,---::-· -=-----::--:~:;::;:--::;-::-:-r-­ Footing f~;;;~·cP!{O-?lr" %/egt.Jk Foundation ________________ _ Grout-------------- Underground Plumbing -=---=--=-o:-----:- Rough Plumbing ,~/6--c'S f?k:.? oc( Framing .s-"--e..-7-o? 9~ ,K Insulation ~' Roofing _71r .--~--.,.-.,.-,--,--------- Drywall 7 -I & -ofS 8N\ Gas Piping ~/tf:o·-o8 =,zc:tv.. p/<:_ NOTES Weatherproofing ______________ _ Mechanical ___________ _ Electrical Rough (State) _______ _ Electrical Final (State) _______ ~-:7""~- Final2 -!tf -/P /Checklist Completed? /f:ii'i Certificate Occupancy # ________ _ Date ________________ _ Septic System #~ -=:;~§~======= Date_ Final__:==::::::=------------- Other ---------------------- (continue on back) INSPECTION W~LL NOT BE MADE UNLESS THIS CARD IS POS:7~D ON THE JOB l ·.'. 24 JHiOilJIRS N01f'ICIE IRJEQilJIRnoiLI FOR RNSI'IECTIONS BUILD 1M PER IT GARFIELD COUNTY, COLORADO Date Issued . ./l:~?:zoned Area ............................... Permit No ... /Of1<J. ..... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. , 2J'! ,-z-- Use Jklthill>V> Jri 0\lilllq \C'.\~M t" OOfu 'f~VV\ 251 G Address or Legal Description (';N;S). Hit\ ~~\\'£\j ~f'• hlti)J C?M.1If Owner Co\l \\A:) I \QU{~ ~JSY\fl Contractor ()IDn£1 Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. Framing s--z_ 7-of5 "'K (To include Roof in place and Windows and Doors instaUed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE 9'15 ~ g-'2-) '2- For liiillSJ!lectia:ms Call384-5003 108 8th St~reet Glellliwood Sprillllgs, Colorado APPROVEDDO NOT DESTROY THJIS CARD ;J VIZ., -. .J.L k /?0/, oate/f~1 svTkml1aldjJV i-ezcr-s~ -"'p IF PLACED OUTSIDE-COVER WITH CLEAR PLASTIC COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at OO~t;:? /4(/JJ 01~~c.y p/, Permit No. / C(/ 77 c:? I have this day inspected this structure and these premises and found the following corrections needed: DICsT + ..S.e'Cc.:;Afp EZoo/C ut/st-!C:Al0AI o/< 7o sl{.e;CT/C.oc-/< 1 cl3AS-e:'.@£_;v?--Co/t/C/CL/Z_ WAC..C S //;c; ;c; 0 /AI .s: q L--L!7/LJ # .. /S / ~I fo~-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date rk-/ 'Z -20 C.> g- Building Inspector --~-r~·"'" "",~+-"-?~_,· "'~~,-==: -=~~='---­ Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ~Cle""'' ~!O<;~_,__~__:rruJ~-"-J~~=.c__-=..:;t__c:_~:::_-=-.-· __ Permit No. ro I I 0 I have this day inspected this structure and these premi~es and found the following corrections needed: • u.JIMLI!ow ~-~ ~ -e;- 3 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Parcel Detail Page 1 of 3 Garfield County Assessor/Treasurer Parcel Detail Information t\$§eSS9r!Ire~t>llre!:Pmp9JtYS9_'ln<h I Assessor_SJJbset Qllm I Ass9$SOLSales Search C!t'<rk&:JSe£m4erBeeePtion_S9l!Lc_!:! Pared PetaiJ I Value Detail SJ!!eS ldel'lil I Residential/Commercial Improvement Detail Land Detail I Photographs I TaxArea II Account Number II Parcel Number II Mill Levy I I o23 II R230931 II 217912400509 II 44.581 I Owner Name and Mailing Address !coLLINS, TODD D. & TINA I 166 MID VALLEY DR INEW CASTLE, co 81647-9656 Legal Description lsECT,TWN,RNG: 12-6-92 DESC: A TR IN I !THE SE 1/4 ALSO A TR IN SE OF SEC I 112 PRE:R230842 BK:0843 PG:0937 I IBK:0843 PG:0127 BK:0728 PG:0934 I IBK:0726 PG:0314 BK:0726 PG:0312 I jBK:0535 PG:0019 BK:0529 PG:0199 I IBK:0824 PG:0771 I Location Physical Address: 1166 335 COUNTY RD NEW CASTLE! Subdivision: I Land Acres: 118.63 I Land Sq Ft: llo Section II Township II Range I 12 II 6 II 92 I http://www. garcoact.com/ assessor/parcel.asp ?ParcelN umber=217912400509 1116/2007 Parcel Detail Page 2 of3 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: 193,oooll 15,3601 I Improvements: 332,52011 26,4701 I Total: 525,52011 41,8301 Sale Date: 11212811992 Sale Price: 1132,000 Basic Building Characteristics Number of Residential 2 Buildings: Number of Comm!lnd 0 Buildings: Residential Building Occurrence 1 Characteristics I TOTAL HEATED AREA: 112,328 I ABSTRACT CODE: I DUPffRIPLEXES- IMPROVEMTS ARCHITECTURAL STYLE: I 2-STORY EXTERIOR WALL: IIWOOD LAP I ROOF COVER: llcOMP SHNGL ROOF STRUCTURE: IIRIDGE FRME INTERIOR WALL: IIDRYW ALL FLOOR: IICARPET FLOOR: IIHARD TILE HEATING FUEL: IlGAS HEATING TYPE: IIFORCED AIR STORIES: IISTORIES 2.0 BATHS: 13 ROOMS: I 7 UNITS: 11 BEDROOMS: 13 YEAR BUILT: 11992 I Tax Information http://www. garcoact.com/ assessor/parcel.asp ?ParcelN umber=21 7912400509 1116/2007 Parcel Detail Tax Year Transaction Type II Amount I 2006 Interest Charge II $16.761 2006 Tax Payment: Second Half II ($837.90)1 2006 Interest Payment II ($16.76)1 2006 Tax Payment: First Half II ($837.90)1 2006 Tax Amount II $1,675.801 2005 II Tax Payment: Whole II ($1,676.96)1 2005 Tax Amount II $1,676.961 ~~ Tax Payment: Whole II ($1,730.04)1 Tax Amount $1,730.041 I 2003 Tax Payment: Whole ($1,925.82)1 I 2003 Tax Amount $1,925.821 I 2002 Tax Payment: Whole ($1,586.68)1 2002 Tax Amount I $1,586.681 2001 Tax Payment: Whole II ($1,578.42)1 2001 Tax Amount $1,578.421 2000 Tax Payment: Whole ($1,614.62)1 2000 Tax Amount $1,614.621 1999 Interest Payment ($16.07)1 1999 Interest Charge $16.071 1999 Tax Payment: Whole ($1,606.96)1 1999 I Tax Amount $1,606.961 Ion ofP<tg\'! Assessor Database Search Options I Treasurer Database Search Options Clerk & Recorder Database Search Options Garfield County Home_l'llg\'! Page 3 of3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2006 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www .garcoact.comlassessor/parcel.asp?Parce1Number=217912400509 11/6/2007