HomeMy WebLinkAboutApplication-PermitGarfield County No. I \Ottt I
Building & Sanitation Department
108 8th Street, Suite #401 Glenwood Springs, Co. 81601
Office 945-8212 Inspection Line 384-5003
Job Address: 146 Bluebell lane, Silt
Locality: Peach Valley Orchard, Lot 16/ 2127-362-01-014
Use of Building: garage
Owner: Nelson, Parsons
Contractor: Murton Builders
Amount of Permit: $995.53 Date:
clerk: _ _..,~ ....... ( 1\..>ti'~'"""'Ol __ _
8
9
10
GARFIELD COUNTY BUILDING PERMIT APPLICATION
108 8'" Street, Suite401, Glenwood Springs, Co 81601
Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003
www.garfield-county.com
o Alteration
Septic:
o Detached
Owners
Authority. This application for a Building Pcnnit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate
Jener of authority, siglled by the Owner, must be provided with this Application.
Legal A<:;;e~s. A Buildiug Penni\ cannot be issued without proof of legal and adequate .1ccess to the property for purposes of inspections by the Building Depart men!.
Other Permits. Multiple separate permits may be required: (I) State Electrical Permit, (2) County !SDS Permit, (3) another pennit required for use on the property identified above, e.g. State or
Counry Highway/ Road Access or a State Wastewater Discharge Penni!,
Void Permit. A Building Pennit becomes null and void if the work authorized is not commenced within !80 days of the date of issuanCe and if work is suspended or abandoned for a period of !SO
days after commencement.
CERTIFICATION
I hereby certify that! have read this Application and that the infunnation contained above is true and correct. ! understand that the Building Department accepts the Application, along with the plans
and specifiCations a11d other data Sllbmitted by me or on my behalf(submittals), based upon my certification as to accuracy.
Assuming completeness of the subnUttals and approval of this Application, a Building Pennit will be issued grantirtg permission to me, as Owner, to constn1ct the structurc(s) and facilities detailed on
the submittals reviewed by the Building Department
In consideration of the issuance of the Building Pc1mit, I agree that I and my agents will comply with pro-visio11s of any federal, state or local law regulating the work and the Grufield County Building
Code, ISDS rcg11lations and applicable land use regulatiollS (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice fi·01n the Cowlty, if the location,
construction or usc of the structure(s) and facility(ics), descn'bcd above, arc not in compliance with County Rcgulation(s) or any other applicable law
I hereby grant pennission to the Building Department to enter the property, described above, to inspect the work. I f\1rthcr acknowledge that the issuance of the Building Pennit does not prevent the
Building Official from: (I) rcqt1iring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or usc of the structure(s) or facility(ies) if such is in violation
of County Regulation(s) or any other applicable law,
Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions
or discrepa11cies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws ru1d County Regulations rest with me and my authorized agents, including without
I imitation my architect designer, m1gineer and/ or bui!dt.:r.
I HEREBY ACKNOWlEDGE TIMT I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOV£:
STAFF USE ONLY
Special Conditions:
AdJusted Valuation: Plan Che~F~fi' I!( Permit l<'ee: bO ~ '3'>
Manu home Fee: Mise Fees:
~'( "St,o ~ cY
ISDS Fed Total Fees: 5) Fees Paid: Balance Due: BP No•& Issue Date: lSDS No & Issued Oate:
qq~ 39d.l"6 (., 0 '3 '3 S' WJFr3
-;:-· Setbacks: OCC Group: Const Type: Zoning:
SIZL
BLDG DEPT: PLNG DEPT:
APPI~ \)l_ I'Z.-\3-o'J .LL ~~ l2--r3-0 1
DATE APP DATE
The following items are required by Garfield County for a final Inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all IBC and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED.
OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance of a
C.O. for the building identified in the Building Permit.
OWNERS 1SlGA'TURE'
Bapplicationseptember2007
VALUATION FEE DETERMINATION
Applicant
Address
Date
Parsons Snbdivision -:1.::;46~B~Iuc...eb;-e-:11;-;L,..n-. --------Lot/Block
.;:lc=2:..:flc::3'-"/2:::0c::0.:..7 ________ ~-Contractor
Finished (Livable Area):
Main
Upper
Lower
Other
Total
Basement:
Unfinished
Square Feet
Valuation
Conversion of Unfinished to Finished
Total Valuation
Garage:
Valuation
Crawl Space
Valuation
Decks/ Patios
Covered
Open
Valuation
Type of Construction:
Occupancy:
Valuation
Total Valuation
sf
sf
sf
sf X $74.68
0 sf
sf X $41.00
sf X $33.68
2520 sf X $18.00
Commercial
sf X $9.00
sf X $24.00
sf X $12.00
sf X
sf X
sf X
sf X
sf X
sf X
fe_o..c),_ 'Allet.t 01' <'-kt{ 11"£.
16
Morton Buildings
0.00
0.00
45,360.00
0.00
0.00
0.00
45,360.00
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan
and it's discovered that required information has not been provided by the applicant, this will result
in the delay of the permit issuance and in proceeding with building construction. The owner or
contractor shall be required to provide this information before the plan review can proceed. Other
plans that are in line for review may be given attention before the new information may be reviewed
after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. Also, please consider
using a design professional for assistance in your design and a construction professional for
construction of your project. Any project with more than ten (10) occupants requires the
plans to be sealed by a Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following checklist prior to
and during design. Applicants are required to indicate appropriately and to submit the
completed checklist at time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and
drawn to scale.
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line
and original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house-rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind
speed, wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
I. Is a site plan included that identifies the location of the proposed structure or addition and
distances to the property lines from each corner of the proposed structure(s) prepared by
a licensed surveyor and has the surveyors signature and professional stamp on the
drawing? Properties with slopes of 30% or greater must be shown on the site plan.
(NOTE Section: 106.2) Any site plan for the placement of any portion of a structure
within 50 ft. of a property line and not within a previously surveyed building envelope on
a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's
signature and professional stamp on the drawing. Any structure to be built within a
building envelope of a lot shown on a recorded subdivision plat shall include a copy of
the building envelope as it is shown on the final plat with the proposed structure located
within the epvelope.
Yes ./ ..
2. Does the site plan also include any other buildings on the property, setback easements and
utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution
if the property you are applying for a building permit on is located on a corner lot. Special
setbacks do apply.
Yes __ ..cv:.__
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage
Disposal System) and the distances to the property lines, wells (on subject property and
adjacent prope. ies), streams or water courses?
Yes ·---'-'/1-1-
4. Does the site plan indicate the location and direction of the County or private road accessing
the property?
2
Yes ____ _
5. Are you aware that prior to submittal of a building permit application you are required to
show proof of a driveway access permit or obtain a statement from the Garfield County Road
& Bridge Department stating one is not necessary? You can contact the Road & Bridge
Department at 6V8601.
Yes. ____ _
6. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the IRC or per stamped engineered design?
Yes v
7. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and the clearances required between wood and earth?
Yes ~
8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist
spaces and soffits?
Yes v/
9. Do the plans include design loads as required by Garfield County for roof snow loads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and wind loads?
Yes V
I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction? /
Yes V ------
II. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafters or jpists or trusses?
Yes V
12. Does the building section drawing or other detail include the method of positive connection
of all columns and be~?
Yes ______ :__
13. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the
· top of a flat roof? (Building height measurement usually not to exceed 25 feet)
Yes __ _.."----
14. Does the plan include any stove or zero clearance fireplace planned for installation including
3
15.
16.
17.
18.
19.
20.
21.
22.
23.
make and model and Colorado Phase II _yertifications or phase II EPA certification?
Yes No __ --::--':V"-----:--:
Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the IRC? /
Yes No ,{/ ---'-'----
Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping rooms and/or basements comply with the requirements of the IRC?
Yes No ____ -"'--
Does the plan include a window schedule or other verification that windows provide natural
light and ventilation for all habitable rooms?
Yes No _________ _
Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface nonnally used as
a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify safety )>lazing for these areas?
Yes i/ No __________ _
Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan? . /
Yes No. ___ v ___ _
Do you understand that if you are building on a parcel of land created by the exemption
process or the subdivision process, are building plans in compliance with all plat notes
and/or covena.)lts?
Yes i/ No ------
Do you understand that if you belong to a Homeowners Association (HOA), it is your
responsibility to obtain written permission from the association, if required by that
association, prior to submitting an application for a building permit? The building
permit application will be accepted without it, but you run the risk of the HOA bringing
action to enforce the covenants, which can result in revocation of permit issued.
Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the
Building Department prior to any action by the HOA that requires either revocation or
substantial modification of the plans.
Yes V No -------
Will this be the onlyj)lSid"Ciltial structure on the parcel? ,
Yes ~· No If no-Explain: ;0 t t1 RRs1?Je,;ftJJ 5T1Ztc-7lire
Have two (2) c01pplete sets of construction drawings been submitt~ application?
Yes. ____ ;:,;V:___
4
24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and
20ft. long? . /
Yes 1./ No ____ _
25. Have you designed or had this plan designed while considering building and other
construction code requirements?
Yes ~No ____ _
26. Do your plans comply with all zoning rules and regulations in the County related to your
properties zone d_istri9t?
Yes V No ------
27. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes [;..-/'. No _____ _
28. Do you understand that approval for design and/or construction changes are required prior
to the application of these changes?
Yes v-No ____ _
29. Do you understand that the Building Department will collect a "Plan Review" fee from you
at the time of application submittal and that you will be required to pay the "Permit Fee" as
well as any "Road Impact" or "Septic System" fees required, at the time you pick up your
building permit?
Yes V No ____ _
30. Are you aware that you must call in for an inspection by 3:30 the business day before
the requested inspection in order to receive it the following business day? Inspections
will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to
be called in to 384-5003.
Yes ___ __,,., No. _____ _
31. Are you aware that requesting inspections on work that is not ready or not accessible will
result in a $50.00 re-lJJspection fee?
Yes ~ No _______ __
32. Are you aware that you are required to call for all inspections required under the IRC
including approval on a final inspection prior to receiving a Certificate of Occupancy and
occupancy of th~ b~ding?
Yes ~ No. _______ _
5
33. Are you aware that the Permit Application must be signed by the Owner or a written
authority being given for an Agent and that the party responsible for the project must comply
with the IRC? . ~
Yes ~ No __________ __
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time of applic~e inspection.
Yes ~ No. ____________ ___
35. Are you aware, that on the front of the Building Permit Application you will need to fill in
the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal
of a building permit app)ication? Your attention in this is appreciated.
Yes V No _______________ _
36. Do you know that the local fire district may require you to submit plans for their review of
fire safety issues? Yes V No (please check with the
building department about this requirement)
37. Do you understand that if you are planning on doing any excavating or grading to the
property prior to issuance of a building permit that you will be required to obtain a grading
permit? . /
Yes ----~v __ _
38. Are you aware that if you will be connecting to a public water and/or sewer system, that the
tap fees have to be paid and the connections inspected by the service provider prior to the
issuance of a Certificate of Occupancy?
Yes ~
I hereby acknowledge that I have read, understand and answered these questions to the
bestofmy~.
/1 fL ~ 17-,/ipr7v7
Signature of Owner Date
Phone: tfr7o. J?f-'f'Z:.?Z (days); X~ (evenings)
Project Name: B~~vvj
Project Address: /ff{ 6/u.M hrM;:_
Notes: If you have answered "No" on any of the questions, you may be required to provide this
6
information at the request of the Building Official prior to beginning the plan review process.
Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a
permit. !fit is determined by the Building Official that additional information is necessary to review
the application and plans to determine minimum compliance with the adopted codes, the application
may be placed behind more recent applications for building permits in the review process and not
reviewed until required information has been provided and the application rotates again to first
position for review, delay in issuance of the permit or delay in proceeding with construction.
Bpminreq November2006
7
PLAN REVIEW CHECKLIST
Applicant pruz__s,, ... "j Date /2-J3-<Y]
Building
~gineered Foundation
_LDriveway Pennit {;!<-L<o\-"--'
_L_Surveyed Site Plan
-F4L-Septic Permit and Setbacks
.t:fLGrade/Topography 30%
~ttach Residential Plan Review List
t/ Minimum Application Questionnaire
_L Subdivision Plat Notes
~Fire Department Review
2Wwilicn Deremiruilioo!Feo~
ed Line Plans/Stamps/Sticker
4Attach Conditions
--I,L.Application Signed
J Plan Reviewer To Sign Application
/ Parcel/Schedule No.
~ 40# Snowload Letter-Manf. Hms.
GENERAL NOTES:
Planning/Zoning
~roperty Line Setbacks
~30ft Stream Setbacks
_JFlood Plain
~uilding Height
___.,L'Zoning Sign-off
~Road Impact Fees
.J.L:_HOAIDRC Approval
/Grade/Topography 40%
~Planning Issues
~Subdivision Plat Notes
No. _l~O:._:_)ft-"--'7}:::..___ Assessor's Parcel No.lJ>\l}-]fcl -CJ\-0\4
Date \~-\4-0"1-
BUILDING PERMIT. CARD
Job Address \YbB\\eten ID-i\l\-. r proch VQUB.( OtcV\od,loH~j
Owner Ihrrott.cs, Y0e\~ . Address\4f>b\,\Ebe\\ I n-~1-Phone # Z'J£-~C)~l
Contractor \-\(JI\~f\ bn,\.c112t5 . Address4d.StDl":>tmct. 'tl\~~~ne # a~\$3
Setbacks: Front ____ Rear ____ RH ____ LH ____ Zoning ___ _
C\~~ INSPECTIONS
Soils Test ---,...----.--:;;=--==,---..,.....,_----
Footing · ~ ~ 1.5"-t$ IOht;
Foundation ________ _
Grout T-t.. .
Underground Plumbing •w•f-0/S
Rough PlumJ>ing -~
Framing (£_-f91-o8 &'7i\
Insulation----------Roofing _________ _
Drywall _________ _
Gas Piping ________ _
NOTES
Weatherproofing _________ _
Mechanical ___________ _
Electrical Rough (State) --===---=--=---=-:::=---
Electrical Final (State) S:-ZB -o l?
Final./-2 -~?? /Checklist Completed? 7<=hJ.
Certificate Occupancy# _la_::_:.b_,='""d.."-'-----:::---
Date ! ~tJ...X:~ r~-"1· 0 '1
Septic System # '»+f~' #FC'?
Date o ~,2-(J -o ·
Final 9 ~~-o8 ?Qiit
Other--------,--------
(continue on back)
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at /tf~ /!4:/~e::LC-d 5'/c'/
Permit No. /t2 7 78
I
I have this day inspected this structure and these
premises and found the following corrections needed:
~I for Re-lnspection
D $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date (:? ~ "3 20 CJ (f
Building Inspector ~ C:~f~ ,
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at ,lfb J3tp;k8/CL(__
Permit No. /t:? 7 78
1 have this day inspected this structure and these
premises and found the following corrections needed:
0& A 6/1/AL.
D $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date /-C,. -CJ'? 20 -~~-
Building Inspector ~ ~~
Phone (970) 945-8212
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
&NSPECTiON Will NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
Date Issued _\.._.1=--·---4\___.L.\'-'· Q""--1{-'-----Permit No. _._I...._QJ]__.__._-""B-----
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations
related to the zoning, location; construction and erection of the proposed structured for which this permit is
granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location,
erection and construction of the above described structure, the permit may then be revoked by notice from the
County Building department and IMMEDIATELY BECOME NUll AND VOID.
use Baraqe
Address or legal Description \ 1-\\..Q £>\ \.le l2e\l Ln. S}j It
owner_pl!rSQ(J;, Ne\£J)n contractor M Ltr±l>n {b,ti lders
Building Permit Type ~~\~d..._,_en\1""'~-'-"-"ru,~,_-----------------------
This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection
INSPECTION RECORD
Footing . Driveway· • ·' '
2·1?·00 OM
Foundation I Grouting Insulation
Underground Plumbing Drywall
LO·~·o~ OM
Rough Plumbing Electric Final (by State Inspector) s-=cz.l>-os'
(Prior to Final)
Rough Mechanical Septic Final
q-a-34 ~
Gas Piping FINAL /-o-c 'l 9(aJ
Electric Rough (by State Inspector)
(You Must Call For Final Inspection)
{Prior to Framing) Notes
Framing 1-·'J-1-D~ DH
(to in dude Roof in place & Windows & Doors installed & Flrestopping in place)
THIS PERMIT IS NOT TRANSFERABLE
For Inspection Call 970-384-5003 Office 970-945-8212
108 8th Street, Suite 401 Glenwood Springs, Colorado 81601
DO NOT DESTROY THIS CARD
APPROVED
Date ____________________________ By ______________________________ ___
PROTECT PERMIT FROM WEATHER DAMAGE
(DO NOT LAMINATE)
Nelson Parsons
146 Bluebell Lane
Silt, CO 81652
ReBuilding Permit# 10778
Peach Valley Orchard, Lot 16
My building has been erected and finished on the outside. The electric has been installed
but I am waiting for a trench to be dug to connect to electrical service.
The concrete slab has yet to be poured. I have decided to install a radiant heat system and
will need a boiler and a condensate drain.
I would also like to install a fiberglass utility sink and a toilet. I would build a small 4
foot by 3 foot room attached to the south wall to house the toilet. I would also like to
have some outside and inside spigots.
I will need to bring water in a trench from my house. I presume I will need a tank and
leach field for the sink and toilet. What are the requirements for that? I will probably just
install the appropriate plumbing needed at this time so I can pour the slab and work on
the rest at a later date.
Thank you,
!lfLP~
Nelson Parsons
970-625-91 00
970-379-4277
lt-------=:=--i-Ji ':r'
u_j
I I I . L
1-----..
e--.-~
'-----1--·
----
~
~ ·~ ~ .~
-~
=
i I ~i
' ~ .c
r~
'-
l"o, '
L-
r c
c~
z
0
1-
< > w
_)
w
I
f-
:::::> (=,
Ln
' /1< ,~'"
.~. t ,)c. "
_l:• <)j-.fl
.V• ?t·.t•
,i..'>',.-,,,-·
Parcel Detail Page 1 of 4
Garfield County Assessor/Treasurer
Parcel Detail Information
A~~e~~or!Irea§l!Ic!:PmperWSc<!Ich I AsseJ>.sor SubseLQnenr I 1\s§_eJ>sor Sales s_\lars::h
~1\lrl~ & R\lcQIQ\lrRecePtionS\l<J.n::h
Basic BuiJding Charact\lristics I I ax Informatiol!
Parcel I;>_etail I Value Detail I Sales Detail I Residential/Commercial Improvement Detail
Land Detail I Photographs
I Tax Area \1 Account Number II Parcel Number II Mill Levy I
I 020 II R005304 II 212736201014 II 45.408 I
Owner Name and Mailing Address
!PARSONS, NELSON & HUSSEMANN, SUSAN I
1146 BLUEBELL LN I
!siLT, co 81652-9704 I
Legal Description
ISECT,TWN,RNG:36-5-92 SUB:PEACH I lv ALLEY ORCHARD LOT: 16 PRE:R200405 I
IBK:349 PG:245 BK:349 PG:244 BK:245 I
IPG:333 BK:240 PG:556 BK: 1125 PG:65 I
IBK:1013 PG:18 BK:l368 PG:llO I
jRECPT:606636 BK:l368 PG:109 I
IRECPT:606635 BK:l368 PG:108 I
IRECPT:606634 BK: 1247 PG:854 I
IRECPT:579825 BK: 1184 PG:366 I
IRECPT:562632 BK:1182 PG:637 I
IRECPT:562144 I
Location
Physical Address: 11146 BLUEBELL LN SILT
Subdivision: IIPEACH VALLEY ORCHARD
II
http://www .garcoact.com/assessor/Parcel.asp? AccountNumber=R005304 12/5/2007
Parcel Detail
I Land Acres: I 10
I Land Sq Ft: I 0
Section I Township II Range I
36 I 5 II 92 I
Property Tax Valuation Information
II Actual Value II Assessed Value I
I
I
I
Land: II 180,00011
Improvements: II 361,47011
Total: II 541,47011
Sale Date: 114/17/2000
Sale Price: 1195,900
Basic Building Characteristics
Number of Residential 1 Buildings:
Number of Co
Buil
Residential Building Occurrence 1 Characteristics
TOTAL HEATED AREA: 112,859
ABSTRACT CODE·IISINGLE FAM.RES-• IMPROVEMTS
ARCHITECTURAL STYLE: III-STORY
EXTERIOR WALL: IIFR STUCCO
ROOF COVER: IIPRO PANEL
ROOF STRUCTURE: IIHIP ROOF
INTERIOR WALL: IIDRYWALL
FLOOR: IIHARD TILE
FLOOR: IICARPET
HEATING FUEL: IlGAS
HEATING TYPE: IIHT WTR RAD
STORIES: IISTORIES 1.0
BATHS: I 2.5
ROOMS: I 7
http://www .garcoact.com/assessor/Parcel.asp? AccountNumber=R005304
14,3301
28,7701
43,1001
I
I
I
I
I
I
I
I
I
Page 2 of 4
12/5/2007
Parcel Detail
I UNITS: II
I BEDROOMS: 14
I YEAR BUILT: 112003 I
Tax Information
Tax Year II Transaction Type II Amount I
2006 II Tax Payment: Second Half II ($835.50)1
2006 Tax Payment: First Half II ($835.50)1
2006 Tax Amount II $1,671.001
2005 Tax Payment: Second Half ($835.45)1
I 2005 Tax Payment: First Half ($835.45)1
I 2005 Tax Amount $1,670.901
2004 Tax Payment: Second Half I ($523.26)1
2004 Tax Payment: First Half II ($523.26)1
2004 Tax Amount II $1,046.521
2003 II Tax Payment: Second Half II ($1,041.17)1
2003 II Interest Payment II ($10.41)1
2003 Interest Charge II $10.411
2003 Tax Payment: First Half II ($1 ,041.17)1
I 2003 Tax Amount II $2,082.341
I 2002 Tax Payment: Whole II ($1,527.72)1
I 2002 II Tax Amount II $1,527.721
2001 II Tax Payment: Second Half ($759.79)1
2001 II Tax Payment: First Half ($759.79)1
2001 II Tax Amount $1,519.581
2000 Tax Payment: Second Half ($657.84)1
2000 Tax Payment: First Half ($657.84)1
2000 Tax Amount II $1,315.681
1999 Tax Payment: Whole II ($31.60)1
1999 II Tax Amount II $31.601
Top of Page
Ass9ss9LR<tt<tb<tse Sear«h OptiPns I Tre<tsureLRatabJJ,seSe<trchOptions
~!erk & Recorder Database_Search Options
http://www .garcoact.comlassessor/Parcel.asp? AccountNumber=R005304
Page 3 of4
12/5/2007