Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite#401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970-384-3470 Inspection Line: 970-384-5003 Building Permit No. Parcel No: 2463-034-00-042 Locality: ____ Daugherty Exemptio_n, L.-.:ot_1 ________ ··-···- Job Address: 2513 st hwy 133~arbondale Use of Building: __ finished basement (2 bed , bath & utility , reck room w/bar & a dark r~om ·- Owner: .. Daugherty! Walter & So_n_dr_a __ Contractor: Owner ----·---·--------··---·--·--- Fees: Plan Check: 100.00 Septic: Bldg Permit: 643.75 Other Fees: --------·-·· Total Fees: $ 743.75 -------- Clerk: ~~~o\ Date: -~-Jl-o~---I 2 3 4 5 6 7 8 Use of Building: 9 Describe Work: 10 Class of Work: 11 Garage: 12 GARFIELD COUNTY BU1LDING PERMIT APPLICATION 108 8" Street, Suite 401, Glenwood Springs, Co 8!601 Phone: 970-945-8212/ Fax: 970-384-3470 /Inspection Line: 970-384-5003 www.garfield-county.com Sq. Ft. or Acres of Lot: Height: o Alteration o Addition o Detached NOTICE No. of Floors: r o Communit Authority. This application for a BuHding Permit must be signed by the Owner of the property, described above, or an authorized agent If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to lhe property for purposes of inspections by the Building Department Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not conunenced within 180 days of the date of is.~uance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct 1 understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department. · In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Department do not constimte an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: OWNERS SIGNATURE DATE STAFF USE ONLY Special Conditions: V~rt-~ ~ Y 1.\ ~~ g;( 1'2 gig) 1'111 Tot-ti ~It (£ )(t s h"'~ \J c((e ·. \~OS Adjusted Valuation: Plan Check Fee: Pernrl~~3 1 ~ Manu home Fee: Mise Fees: ·····t;CJ 0/1 7 " /00°(.) (/ c( ISDS Fee: Total Fees: ') Fees Paid: Balance Due: BP No & Issue Date: ISDS No & Issued Date: C6 'll-\.,.., jtSO.CJD (,l\) 1) f()D.<;.l Setbacks: OCCGroup: ConstType: Zoning: . ;FrtC BLDG DEPT: PLNGDEPT: _l\\'J>~R ::2-'7-di: APP~~l ?--7-<:S lr •uTI<' DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all me and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED .. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. ~ldd,~114= OWNERS SIGNRE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date .ODC:a':"U~gh:;;e~rty~==-.,--.,---,---,--'-'--Subdivision -:=2=:51::;;3:,:HWY~.:,..::1;:.:33'------~--Lot!Biock ::.2::..17:.:.12::::0::.:0:.::8c_ ______ -'-'---'--'-Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 1457 sf X $33.68 Commercial sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 sf X sf X sf X sf X sf X sf X Daugherty Exempt 16 Owner 0.00 49,071.76 0.00 0.00 0.00 0.00 49,071.76 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. T '#j ~J ctf'_ c<M;WW.P.ev£ ";)J.-4Wfl4y <t 2 Yr~£ fc_~ fi1lUf ae Pl~!e\!i~is ~ummt'To 'll'fe~)~i?ifo~ have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing .and foundation plan, elevations all sides with decks, 1 balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be desigued to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. ~ 1. Is A site pla(included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor. and has the surveyors siguature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any.portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision fmal plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes* 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply . .1 Yes '6, -~~---- 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes $ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? J Yes·---fA-. __ 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal govermnent or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes y{ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordan+cewith the IRC or per stamped engineered design? · Yes ·--,71'r-• -. 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances rjuired between wood and earth? Yes )< No ____ _ 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes _____ _ No __ 1 -fl(,__ __ 9. Do the plans include design loads as required by Garfield County for roo(snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes A 10. Does the pL~lude a building section drawing indicating foundation, wall, floor, and roof constructi~ Yes __ T-J..,t-+--- 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes ____ ~r-- 12. Does the building section drawing or other detail include the method of positive connection of all columns and 1 b;rms? Yes ___ -\(:::-f---- 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roop (Building height measurement usually not to exceed 25 feet) Yes k. · :B.,, ( J i "'"'.> c:d,( r etJ-J'f \ "'-p lo..c...t . 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II i(rtifications or phase II EPA certification? Yes No _ . ,? 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes ______ No. __ __,V"' __ _ 1\ 16. Does the plan include a window ~chedule or~ verification that egress/rescue windows from ~::ping rofs and/or basements comply with the requirements of the IRC? 17. Does the plan i:lude a window schedule or other verification that windows provide natural light and ventilation fo~ll habitable rooms? Yes ____ A-- / 18. Do the plans indicate the location of glazing subject to human 'impact such as glass doors; glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for t~e areas? Yes ~ No ______ __ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes 'k 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision rocess, are building plans in compliance with all plat notes and/or covenants? Yes __ ko-- 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation o~}ubstantial modification of the plans. Yes·----,7\~-- 22. Will this be the only residential structure on the parcel? 1 Yes X: No . ~ Ifno-Explain: r hvp<' So>'V\.Jt.... d"Y fH-'''"' ({ Au 0 ,......... t9 fgr<;,bf<- 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes ' 24. Do you underRst nd that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes ---rr---- 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes V 0 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district?~ Yes _____ ~A.--- 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes Y p\ 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes '? """ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Imp~ct" or "Septic System" fees required, at the time you pick up your building permit? Yes )( _ ---,/.P.'\c---- 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-500~3. Yes No. _____ _ I 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes y 32. Are you aware that you are required to call for all inspections required under the IRC in<;_luding approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? '\ j Yes-r- 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for a~;gent and that the party responsible for the project must comply with the IRC? Yes ___ ~-'k---- 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, uoless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes ~ """ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permi: ayplication? Your attention in this is appreciated. Yes ____ ¥.~---- 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? , / Yes ';<__ (please check with the building department about this requirement) r~ 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuank building permit that you will be required to obtain a grading permit? Yes 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes 'I I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. t'0 1i 1J11j Phone: 90,~ OS:.Z(o ol(" . (days); Project Name: SA se Yrl ~ 1/\, ..(_ {.'!, h. ''s h. 6 J_eb /s-1-~oof? Date --t-9""'G,""'_s"--"0'-'5~2~~-'----(· evenings) Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with · construction. BpminreqDec2007 7 . GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, llv1C, JPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. Seismic design category: B 7 SPSF 8001 to 9000ft. 100PSF 9001 to lOOOOft. Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 MinimumR-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Wails R values ai:e R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • Basement wall R-values are R-IO beiow grade, R -19 above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant OA~~~.~\oet?-\~, Date 7--7 -o¥' r Building J4t.._Engineered Foundation __0riveway Permit f:,t, 5·1-.../ ~Surveyed Site Plan J;.A·~ \ •'1] V' Septic Permit and Setbacks .;.z~ ~.< / "' &.Jill ..... ~ _L_Grade/Topography 30% -L.Lfittach Residential Plan Review List ~Minimum Application Questionnaire 1:4Lsubdivision Plat Notes ~Fire Department Review ~aluation Determination/Fees URed Line Plans/Stamps/Sticker ~Attach Conditions __.tL'Application Signed ~an Reviewer To Sign Application _0arcel/Schedule No. ~ 40# Snowload Letter-Manf. Bms. GENERAL NOTES: Planning/Zoning __ 30ftStre . ~Flood ain ~uil illg HcigM __ Z ing Sign-off ~ --+Grade/Topography 40% N 10837 o. ________________ __ Assessor's Parcel No. 2463-034-00-042 Date 2/11/2008 BUILDING PERMIT CARD JobAddress ___ ~2~5~1~3~s~t~hwy~~1~3~3,~C~a~r~b~o~nd~a~l~e~(D~a~u~g~h~e~rt~y~E~x~e~m~p~t~io~n~,~lo~t~1~)------------------------ 0wner Daugherty, Walter & Sondra Address 2551 st hwy 133, C'dale Phone # 963-0526 Contractor _____ o_w_n_e~r ___________ Address ___ s_a_m_e_a_s_o_w_ne_r ____ Phone # 274-0017 Setb~s:, :7n~,..,---r---Rear -----RH, ________ LH _____ Zoning _______ _ ~ ~ INSPECTIONS Soils Test Weatherproofing _______________ __ Footing .,~ Mechanical , Foundation I Electrical Rough (State) __ v~""'/'--------- Grout Electrical Final (State) __ __,7'----------- Underground Plumbing ~£ • _../~inal /b-10-0 8 /Checklist Completed? Rough Plumbing ~ Certificate Occupancy # ---------- Framing 3-I 1-0 g Date------==--------- Insulation ~ · :J -e~'ff '1l'JPl, Septic System # -=$R.I?~"'--~=---'"'------------ Roofing Date----------------- Drywall lf·/7'05~ Final ___________ _ Gas Piping_·~--~~-----------Other ___________________ __ COUNTY OF GARFIELD • BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at .;;:l :)'"/ 3 ~1£-/3 3 f' Permit No. )08's2 I have this day inspected this structure and these premises and found the following corrections needed: J(call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 3-.J..8'-d;?' 20 ::;n---- Building Inspector --~~ Phone (970) 945-8212 INSPECTION Will NOT BE MADE UNlESS THIS CARD IS POSTED ON THE JOB . 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date lssue~:::\11>-~ .•... Zoned Area ............................... Permit No..\(16.~ ............ . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Insp.ector and IMMEDIATELY BECOME NULL AND VOID. Use lYi\!!>h \m&AE\lt (~Pl'dfitl!Jt\,\::g}\1)\ \)\IUl\1 ttfX,'roCW\\))\Mr\Otu''(~W\J Address or Legal Description »>SB <;;;.\-~~ \5! c:\r1rue , Owner ~~ll)('f'1\\, hlli\I~f] ::i,(!)V\U\"\! Contractor ~\)..)'1\t{' Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From Tbe Street Until Final Inspection. INSPECTION RECORD Footing •y Driveway Foundation ?'("' 6 1"'_.:"·.-r. Underground Plumbing Insulation i-3 :<>'ii:-hZ Rough Plumbing • .-1:. Drywall 'f. J7·0if~ Chimney & Vent . . Electric Fimal (by State loh 1op, ,Gas Piping .i:...h~.h Finalfo-10-o'i> ~;??7~ :r Electric Rongb (By State Insl!@%rl !:f!jC-Septic Final Framing 3·/'t.-ug A}J1_ Notes: (To include Roof in place and Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING- WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 108 8th Street Glenwood Springs, Colorado APPROVED DO NOT DESTROY THIS CARD oau().-J\-6~ ey • nnwm IF PLACED OUTSI E-COVER WITH CLEAR PLASTIC Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information A.~sessor/TreasureJ Pro~~earch I Assessor Subset_Qn~ I AssessoLS.ales Search Clerk & Recorder Rec~.Jion Search P~l Detail I Value Detail I Sales.J&tilll I Residential/Commerciallmprovement Detail LandJ2etail I Photogmphs I Tax Area Jl Account Number II Parcel Number II 2007 Mill Levy I I 009 II R090216 II 246303400042 II 60.788 I Owner Name and Mailing Address jDAUGHERTY, WALTER & SONDRA LEE I j2551 HIGHWAY 133 I . jCARBONDALE, CO 81623 I Legal Description \SECT,TWN,RNG:3-8-88 DESC: A TRIN I jLOT 16 CONT 4.570 AC. AKA LOT 1 I jDESC: DAUGHERTY EXEMPTION. I IPRE:R090023 BK:0960 PG:0579 BK:0934 I !PG:0285 BK:0850 PG:0942 BK:0482 I IPG:0298 BK:0421 PG:0409 BK:0419 I IPG:0387 BK:0405 PG:0567 BK:0075 I jPG:0499 BK:1538 PG:361 RECPT:640750 I jBK:l321 PG:804 RECPT:595836 I Location I Physical Address: 2513 HIGHWAY 133 CARBONDALEj I Subdivision: I Land Acres: 4.57 I Land Sq Ft: 0 II II http://www.garcoact.com/assessor/parcel.asp?Parce!Number=246303400042 2/1/2008 Parcel Detail Page 2 of4 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 5oo,oooll 39,800/ I Improvements: II 183, Iooll 14,570/ I Total: II 683,100/l 54,370/ II Sale Date: I Sale Price: I Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd lo I Buildings: I Residential Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: jj1,536 I I II SINGLE F AM.RES-ABSTRACT CODE: }MPROVEMTS I I ARCHITECTURAL STYLE: jjl-STRY/BSM I I EXTERIOR WALL: IIT-11 SHTNG I I EXTERIOR WALL: //MASONITE I I ROOF COVER: jjCOMP SHNGL I I ROOF STRUCTURE: jjGABLE I I INTERIOR WALL: //DRYWALL I I FLOOR: IIHARD TILE I I FLOOR: jjCARPET I I FLOOR: IIHARDWOOD I I HEATING FUEL: IiGAS I I HEATING TYPE: IIHOT WATER I I STORIES: jjSTORlES 1.0 I I BATHS: II I ROOMS: j6 I UNITS: II http://www.garcoact.com/assessor/parcel.asp?Parce!Number=246303400042 2/112008 Parcel Detail Page 3 of4 YEAR BUILT: 111973 Tax Information I Tax Year II Transaction Type II Amount I I 2007 II Tax Amount II $3,305.041 I 2006 II Interest Payment II ($44.40)1 I 2006 II Interest Charge II $44.401 I 2006 II Tax Payment: Whole II ($1,480.08)1 I 2006 II Tax Amount II $1,480.081 I 2005 II Tax Payment: Whole II ($1,486.50)1 I 2005 II Interest Payment II ($59.46)1 I 2005 II Interest Charge II $59.461 I 2005 II Tax Amount II $1,486.501 I 2004 II Interest Charge II $73.901 I 2004 II Tax Payment: Whole II ($1,477.94)1 I 2004 II Interest Payment II ($73.90)1 I 2004 II Tax Amount II $1,477.941 I 2003 II Tax Payment: Whole II ($1 ,242.28)/ I 2003 II Interest Payment II ($74.54)1 I 2003 II Interest Charge II $74.541 I 2003 II Tax Amount II $1,242.281 I 2002 II Interest Payment II ($65.93)1 I 2002 II Interest Charge II $65.931 I 2002 II Tax Payment: Whole II ($1,318.60)1 I 2002 II Tax Amount II $1,318.601 I 2001 II Tax Payment: Whole II ($1,325.92)1 I 2001 II Interest Payment II ($66.30)1 I 2001 II Interest Charge II $66.301 I 2001 II Tax Amount II $1,325.921 I 2000 II Interest Charge II $112.491 I 2000 II Tax Payment: Whole II ($1,874.84)1 I 2000 II Interest Payment II ($112.49)1 I 2000 II Tax Amount II $1,874.841 I 1999 II Interest Payment II ($92.47)1 I 1999 II Interest Charge II $92.471 I 1999 II Tax Payment: Whole II ($1,849.34)1 II II http://www.garcoact.com/assessor/parcel.asp?Parce!Number=246303400042 2/112008 Parcel Detail \I 1999 II Tax Amount II $1,849.341\ ThJ;l of Pa,g~ Asse£sor Datal::l!JSe S~m:ch Qption~ I Treas_!lrer Il_atabase Sear.Qh Options Clerk &;~prder Datal::l~earch__Qptions Page4 of4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by Goo!Liums Software. -------- http://www.garcoact.com/assessor/parcel.asp?Parce1Nurnber=246303400042 2/112008 •. '" ' GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, SuHe 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 Permit 4 09 7 AIHIIOr't Parcel No. This does not conetltuto Legal Dallcription of Assessor's Parcel No. ____ ___:,d=::::..'i...!...::Cc.O::.,.,~<!,_-_b=:;_3,_!._Y.!__-_~,Q~D....L-_;.(j..t.H~£bz:,_ ____ _ SYSTEM DESIGN I, c (l , r ::J Septic Tank Capacity (gallon) -----!Oihet _ _,_l-".6.,_ __ Percolation Rate (minutes/inch) ·4 Number of Bedrooms (or other) _ _;_ __ Required Abeorption Area -Soo Attached fj' 7 .:; jZ oc. k l_., ftc;!::~ r 1_.:; t> , . / ,. 11 1137.:::-1if ~.#>•~ (l~~ 'I,, Pf" SpeclaiSatbeckRequlrementa: Sf' ~:/e~/dl'~ 'I ]'I Date 5-If. O' -r/tf 4'~ _...::_.I...:._,.,_._,"'"------lnapsctor J.?::j"f::t!f; / FI.L SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation Septic Tank Manufacturer or Trade Name .,___;C::c'lh.::...co:·vr::. .. c;· ~="'---------------------- Septic Tank Aeceas within 8'' of surface ---'-1""''-"-------------------------- Absorptlon Area V 0 1 A "-}0 Adequate compliance wilh County ond State reguletlons/requlrements.---2\+.-t:.aL.-------------- Other ______ ~----~----------~------~r------------- Oate_.L-j \ __ (-+-1_6:uc(Jt.LP--1nspector ---+1\w):.u.,.fl;Le\ :-..~...1· .fAJ-/-l)1.L\"-'-( £.f-C.J-\-c-.. ------ RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDtnONS: 1. AlllnetallaUon must comply w"h all requlramenta of tho Colorado Stale Board of Health IndiVIdual Sewage Disposal Syatoma Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. Tlli& parmi\ IS volldonly tor connection to 11\Tuctum which have fully compliadwl\11 County tonlnll and bulldingf8C!Uiramenl8. Co~>­ nectlon to or uoo with any dWalllng or atructuraa not approved by tho Building and Zoning office &hall automallcally be a violation or a requirement of tho parmlland cauaefor both legal action and revocation or tho permit. 3. Any person who conSituela. altera, or lnetallsan Individual MWege disposal li)'Jiem In a manner Which lnvol-a knowing and malorial variation from lha terms or specifications conlalnad in lho application of permit commits a Clasa I, Patty Offenoe ($500.110 line-6 mot'lths in jail or both). • INDIVIDUAL SEW AGE DISPOSAL SYSTEM APPLlCA TlON PHONE 'f6 ? t> f"lt;. PERMIT REQUEST FOR (> NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATIONOFPROPOSEDFAClLITY: Lof ( J)J.':Jkef~ eiCJ?Mfh'D() f/wl.f. /1~ Near what City ofT own c-. v £., h ,.£ h ~ Size of Lot 0 ) .Ju.,.,; Legal Description or Address .4dtrt:> /-r:, b .c. 7 1 1 v 19 ,.._ ~'( { 3 3:> C IJ. Q /..q_ WASTES TYPE: 0 DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ()OTHER-DESCRIBE ___________________________ __ BUILDING OR SERVICE TYPE: __ $=--f--(JLE~d.-"--"-£Ne"""'-1(~(J!29=j 7-----------~ NwnberofBedrooms_~'------------NumberofPersons._--z._.,____.,=--- ( ) Garbage Grinder ( ) Automatic Washer 9<) Dishwasher SOURCEANDTYPEOFWATERSUPPLY: ( )WELL ( )SPRING ( )STREAMORCREEK If supplied by Community Water, give name of supplier: 7 ]..._ 'To"'"-• C C'v, ;, ..... ,/ .. ./ .... DISTANCE TO NEAREST COMMUN1TY SEWER SYSTEM:--'-lj_'--"....,=~_,_: '-='(._..."'-------- Was an effort made to connect to the Community System? --P--"'------------- A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: SO feet Leach Field to Irrigation Ditches, Stream or Water Course: SO feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIV1DUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table. ___ .~"".>"-'cJ"-];:::?..::.}_J _______________ _ ,r-c) Percent Ground Slope ___ .,_.2'-'::>o:....4?--------------------- 2 TYPE OF INDIVIDUAL SEW AGE DISPOSAL SYSTEM PROPOSED: (v( SEPTICTANK ( ) AERATIONPLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER-DESCRIBE F!NA):-DISPOSAL BY: ( v( ABSORPTION TRENCH, BED OR PIT ( ) UNDERGROUND DISPERSAL ( ) ABOVE GROUND DISPERSAL ( ) EVAPOTRANSPIRATION ( ) SAND FILTER ( ) WASTEWATERPOND ( ) OTHER-DESCRIBE ______ ~---------------- WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE?~f~<'~J--­ PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes. _____ per inch in hole No. 1 Minutes ______ per inch in hole No. 3 Minutes. _____ per inch in hole No. 2 Minutes per inch in hole No. _ Name, address and telephone of RPE who made soil absorption tests: ------------- Name, address and telephone ofRPE responsible for design of the system:---------- Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the penn it is subject to such tenus and conditions as deemed necessary to insure compliance with rules and regulations made, infonnation and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the pennit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any penni! granted based upon said application and in legal action for perjury as provided by law. 3