Loading...
HomeMy WebLinkAboutApplicationRE: FIRES Divide Road Water Facility - Injection Pump Building 'af f eld County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-8212 www.garfield-countv.com ,,TYPE OF CONSTRUCTION d Commercial/Multi-Family ❑ Manufactured Home (SF or Duplex) O Residential (SF, Duplex, or Townhome) BUILDING PERMIT APPLICATION Demolition Reroof INVOLVED PARTIES Renata Busch Property Owner: Hunter Ridge Energy Services, LLC Phone: ( 970 ) 285-2825 Mailing Address: 143 Diamond Avenue, Parachute, CO. 81635 Contractor: Standard Industrial Structures, Corporation (???) Mailing Address: 2665 Westhollow Drive, Houston, TX. 77082 Architect: Phone: ( 281 ) 531-2800 Phone:( ) Mailing Address: Engineer: Samuel Eng;neering, Inc. Phone: ( 303 ) 714-4840 Mailing Address: 8450 East Crescent Parkway, Suite 200, Greenwood Village, CO. 80111 Manufactured Home Installer: N/A Phone: Mailing Address: PROJECT NAME AND LOCATION Reference: Divide Road Water Facility (Resolution 2013-14) Describe Work: Installation of a Injection Pump Building at the Divide Road Water Facility Job Address: None Assigned - Sec. 26, T4S, R96W, 6th P.M. Assessor's Parcel Number: 191727400012 Sub. Lot Block Owner's Valuation of Work: $ 586,448.00 Sq.Ft of Building: 9112 Class of Work: Garage: Septic: Type of Heat: Driveway Permit: Height: 32' Property Size (Sq.Ft or Acres): # of Floors: 1 O New I 0 Alteration 0 Addition ❑ Attached ❑ ISDS O Natural Gas 0 Propane 0 Repair 0 Move/Relocation ❑ Detached O Community 0 Electric 0 Other ❑ Exempt O Permit #: Building Plan Review Description of Work: New Injection Pump Building Bin #: Location Address: "" "" PARACHUTE, CO 42: General Information Case Manager: David Bartholomew Plan Case Number: BLDG -12-13-7788 Parcel: 191727400012 Application Date: 12/31/2013 • Owner: EnCana Oil and Gas Applicant: EnCana Oil and Gas Applicant Phone: (970)285-2656 Email: jasoneckman@enca Building i-1/4 Nyfr Engineered Foundation Driveway Permit Surveyed Site Plan Septic Permit and Setbacks Grade/Topography 30% p Attach Residential Plan Review List Minimum Application Questionnare All/ Subdivision Plat Notes Fire Department Review Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building height Zoning Sign -off P/4 4 Road Impact Fees /U OAIDRC Approval Grade/Topography 40% / Planning Issues Valuation Determination/Fees Subdivision Plat Red Line Plans/Stamps/Sticker Attach Conditions Application Signed Plan Reviewer To Sign Application Parcel/Schedule No. AY1 40# Snowload Letter - Manu. Homes Soils Report General Comments: Monday, January 6, 2014 F1 Applicant Address Date VALUATION FEE DETERMINATION EnCana/Hunter Ridge Energy Divide Road Water Facility, Parachute 1/6/2014 Subdivision Lot/Block Contractor Finished (Livable Area): Main sq.ft Upper sq.ft Lower sq.ft Other sq f1 X $74.68 Total Square Feet 0 sq.ft Total Valuation Basement: Unfinished Conversion of Unfinished to Finished Other Total Valuation Garage/Storage (wood framed) Conversion of garage to finished living Carport Other Total Valuation Crawl Space Total Valuation Decks/ Patios/Porches Covered Open Other Total Valuation Type of Construction: Occupancy: IIB Total Valuation Total Valuation sq.ft X $41.00 sq.ft X $33.68 sq.it X sq.ft X $18.00 sq.ft X $56.68 sq.ft X $12.00 sq.ft X sq.ft X $9.00 sq.ft X $24.00 sq.ft X $12.00 sq.fI X Commercial 9112 sf X sf X sf X sf X sf X sf X $64.36 N/A N/A Standard Industrial 0.00 0.00 0.00 0.00 0.00 586,448.32 586,448.32 NOTICE Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Budding Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division. Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit, Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. hereby grant permission to the Building Division to enter the property, described above, to inspect the work. further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. 1 hereby acknowledge that I have read and understand the Notice and Certification above as well as have provided the required information which is correct and accurate to the best of my knowledge. R. Busch Property Owner Print and Sign 12-31-2013 Date OFFICIAL USE ONLY Special Conditions: Adjusted Valuation: 586/148 Plan Check Fee: 2370.55 Permit Fee: 36T,ao Manu home Fee: Misc Fees: — Total Fees: 60/7, 55 Fees Paid: 58.5q Balance Due: 5,446A6 BP No: 1505 No: B -BO3q �- Setbacks:� l''..4eZ,.; 5[ref OCC Group: + f Const Type: � `� Zoning: gL BUILDING / PLANNING DIVISION / /ii" Signed Approval ate plufrr i 31.1 c a - 5116.59 NOTE: If any required information is missing, delays in issuing the permit are to be expected. If determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Review fee at time of application submittal. The Permit Fee, as well as any Septic or Road Impact fees will be collected when the permit is issued. The permit application must be signed by the owner or by a person having written authority from the owner to act as their representative. 1 hereby acknowledge 1 have read, understand, and will abide with the requirements of this checklist. R. Busch L.tt r 12-31-2013 Property Owner Print and Sign Date Garfield Go,,,rty Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-8212 www.garfield-county.com COMMERCIAL OR MULTI -FAMILY BUILDING PERMIT APPLICATION CHECKLIST OMMERCIA b. R MULTI -FAMILY BUILDING PERMIT APPLICATION CHECKLIST In or.er to understand the scope of work intended and to expedite the issuance of a permit, it is important that complete information be provided. Please review this document to determine if you have adequate information to design your project and to facilitate a plan review. APPLICATION FORM: Please make sure the following information is provided on the application. • Parcel number obtained from the County Assessor's Office. • Job address (assigned physical address). • Legal Description: lot, block, filing, subdivision or tract, section, township and range. • Owners name, mailing address, phone, fax, or cell. • Contactors name, mailing address, phone, fax, or cell. • Architect/Engineer's name, mailing address, phone, fax or cell. • Building size, height, number of stories, lot size. • Use of building (commercial) • Class of Work (new, addition, alteration, repair, demo, move, other) • Description of work. • Type of heating (natural gas, propane, electric, other) • Sewer system (Community or ISDS), also see other items below. • Garage (attached or detached) • Driveway permit (please see other items below) • Valuation (labor and materials) OTHER ITEMS: • If you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that the City will provide water service. (Required to submit building permit application). • ISDS requires a septic permit application to be submitted with the building permit application. • A separate electrical permit must be obtained from the State of Colorado Electrical Board. • At the time of building permit submittal, you are required to show proof of legal and adequate access to the site. This may include proof of right to use a private easement, County Road & Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The County Road & Bridge Department can be reached at 970-625-8601. • If you anticipate excavating or grading prior to issuance of a building permit, you will be required to obtain a separate grading permit. • If you belong to a Homeowners Association, it is your responsibility to obtain written approval, if required. • Provide copies of any Resolutions and/or Land Use Permits associated with this property. • Projects with more than 10 occupants require plans sealed by a Colorado Licensed Design Professional. Occupant load shall be calculated by IBC Table 1004.1.1. • A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups. BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete, identical, legible, and to scale. Certain projects may also require a third copy of the plans be submitted to the local Fire District for review prior to permit issuance. All plans will be checked at the counter for completeness. If any of the required information is missing, the building permit application cannot be accepted. SITE PLAN: Please make sure the following information is provided on the site plan. • Property address/legal description. • North Arrow and Scale on each page. • Show all property lines, building envelopes, flood plain, and easements. • Provide setback distances from boundaries, buildings, septic, well, and waterways. • Location and direction of the county or private road and driveway accessing the property. • Proposed and existing structures include sheds, barns, decks, patios, and any other buildings. • Existing and proposed grade, positive drainage around structure (to be contained on site). • Streams, rivers, creeks, springs, ponds and ditches. • Existing and proposed wells, septic tanks, leach fields, and other systems. (if applicable) • Retaining walls (engineer stamped detail required for walls over 4 ft, measured from bottom of footing to top of wall). NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property line or not within an established building envelope shall be prepared, stamped, and signed by a licensed surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision final plat with the proposed structure located in the building envelope. COVER SHEET: • Project identification. • Project address and/or legal description. • Design specifications to include building use and occupancy classification, type of construction, building height and area calculations, occupant Toad, and fire sprinkler systems. ARCHITECTURAL PLANS: Please provide the following information on the architectural plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Design Professional stamped plans. • Minimum 4 elevations (N,S,E,W) • Floor plans for each level including dimensions and scale noted. • Clearly label each room or space (office, storage, mechanical, elevator, etc). • Wall types; clearly labeled and referenced. Identify all fire resistive wall construction. • Construction details for all fire resistive elements referenced on floor plans and cross sections. Include wall, floor/ceiling, roof/ceiling, shaft wall assemblies, and structural frame. Provide the fire resistive listing number referenced on each assembly detail. (ex. UL P123) • Window & door sizes, types, and operation and direction of swing noted on the floor plan. • Specify roof slope/pitch, roof covering, and siding materials. • Energy design specifications/details for R -values, U -factors, and SHGC's per IECC. • Stair and guard details specifying rise, run, height and spacing. • Accessibility; show compliance with accessibility requirements for all elements of the building per IBC, Chapter 11 and ICC/ANSI A 117.1, ADA, FHA, and UFAS. STRUCTURAL PLANS: Please provide the following information on the structural plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Engineer stamped plans. • Engineered foundation design per soils report. Geotechnical report referenced. • Design specifications to include roof and deck snow load, wind and seismic design, frost depth. • Foundation plan showing complete footing and foundation dimensions. • Footing and foundation details specifying reinforcement referenced on plans. • Framing plans for each floor level and roof. All beams, columns, joists, rafters, trusses and all live/dead loads specified. • Framing /connection details referenced on plans. • Pre -manufactured structures require an engineers stamp, signature, and date. MECHANICAL PLANS: Please provide the following information on the mechanical plans. • Per C.R.S. 12-4-112; Structures designed with an occupant Toad exceeding 10 require Colorado State Licensed Engineer stamped plans. • Energy design calculations and details verifying compliance with the 2009 IECC. • Floor plans for each level showing size, location and materials of all ductwork, plenums, return and outside air intake registers. • Size and location of all combustion air ductwork and openings. • Size, type and termination of all gas appliance flues and vents. • Location of all fire and combination smoke/fire dampers. • Equipment schedule for all mechanical equipment (boiler, furnace, exhaust fans, etc). • Commercial kitchen hood location, hood and duct sizes, CFM calculations. PLUMBING PLANS: Please provide the following information on the plumbing plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Engineer stamped plans. • Floor plans for each level showing DWV layout and sizing, materials, slope and sewer location. • Water piping materials, length and size of pipe, water meter location, fixture unit demands, location and type of backflow prevention devices. • Gas piping materials, length and size of pipe, gas meter location, and BTU/hour demands. • Additional piping plans for roof/deck drains, condensate, medical gas, etc. • Plumbing fixture schedule for all plumbing equipment. • Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc. ELECTRICAL PLANS: Please provide the following information on the electrical plans. • Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Engineer stamped plans. • Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency exit signs and lighting, and panel location. • Diagram showing service entrance, conduit/wire size, main disconnect size, grounding electrode/conductor size, feeder conduit/wire size, transformers and generators. • Panel schedule showing bus/breaker sizes, circuit description, voltage, phase, amperage, etc.