HomeMy WebLinkAboutStructural CalculationsSTATE OF COLORADO FACTORY BUILT NON RESIDENTIAL APPLICATION Fee due with application -Not subject to return Mar 2013 Name of Manufacturer: Wedge Energy Services Plant Mailing Address: Wedge Energy Services Plant street address: PiantT.6. Number: 461 N Broadway Joshua, TX 76058 4272 461 N Broadway Joshua, TX 76058 Contact Person/email address: Matt McCarty: matt.mccarty@wedge-es.com Plant Telephone: Fax No: Telephone No: 817-426-9810 817-426-9777 817-426-9806 Third Party Inspection Agency: NTA Inc. Mailing Address: P.O. Box 490 Nappanee, IN 46550 Telephone No: 574-773-7975 Fax No: 574-773-2732 Yes 2012 I -Code Compliant Roof snow load Yes 2011 NEC Compliant Wind Design Speed 100 PSF 130 MPH Yes 2012 IECC Compliant Seismic Category B Yes 2009 IECC Compliant Floor Design Load Occupancy Eke: > 200 amp NO 3 phase NO 125 PSF Special occupancy(NEC) NO Fee Schedule Total foota.e Amount Model Name/No. 8x14LEVELI Annual Registration Fee (must be accompanied by new/updated QA Manual, minimum 2 copies -maximum 3 copies) $500.00/per factory location Fee Calculator for Plan Approvals= (Building Square footage) x (factor indicated below): Manufactured portion only State of Colorado Division of Housing October 18, 2013 ,' DIY C C%ir-) . `1..." (''I [- Plan Approval Fee- $0.25/sq. ft. (Finished floor area) $0.10/sq. ft. (Unfinished floor area) i.e. garage, unfinished loft minimum 2 copies -maximum 3 copies,. 112 Minimum Fee for Plan Approvals- $160.00 $160.00 Lf PLANS APPROVED Additional Plan Set- $0.10/sq.ft. Minimum Fee for Additional Plan Set- $50.00 Plan Approval Number 6886 Plan Revision- $0.10/sq.ft. (Space revised)• FedEx or UPS No. (If overnight shipping of approved plans requested) Minimum Fee for Plan Revision- $50.00 TOTAL AMOUNT SUBMITTED: $160.00 EXPIRES: August 1, 2014 MANUFACTURER CERTIFIES that only approved equipment and materials will be used and the installations shall be made in accordance with approved plans and applicable codes and provisions of the Colorado Division of Housing. Manufacturer agrees to in -plant inspection of units manufactured under the above plan approval. Application shall be made for and insignia affixed to each factory built non residential unit that is subject to Colorado statutes and which is manufactured or is to be sold, offered for sate, or occupied in the Slate of Colorado. DIV. OF HOUSING, 1313 SHERMAN STREET, RM 321, DENVER, CO. 80203 (303) 866-4616 Fax 866-3072 Structural Calculations L&S Pro -Line 8' 0"x l 4'0" Prefabricated Building Colorado September, 2013 Project No. 13232 Bradley J. Isbell, P.E. Bradley J. Isbell, P.E October 24, 2013 Shannon Thornton L&S Pro -Line 2239 Saint Beulah Montgomery, Texas 77316 RE: 8'-0"x14'-0" Prefabricated Building Located in Colorado Dear Mr. Thornton: This is to certify that we have analyzed the 8'-0"x14'-0" prefabricated building. The building was analyzed for the location in Colorado that you provided us, with the following criteria: 8' -0"x14' -0"x7'-10" high, Prefabricated Metal Building S -1 -Storage Shelter One Story, 112 Square Feet Construction Type VB Structural Building Codes: 2012 International Building Code; ASCE 07-10 The building was also designed for the following design loads: Floor Dead Load: 11 psf Floor Live Load: 125 psf Roof Dead Load: 10 psf Roof Snow Load: 100 psf Wind Speed: 130 mph Seismic Design Category: B Seismic Response Coefficients: Sds=0.333 g Sd1=0.072 g Refer to the attached calculations for more detailed design criteria and the calculations for the building. We have also included a sealed design sheet for your drawings. Based on our calculations, the building in our professional opinion is designed to withstand the code design loads for the location you supplied in Colorado. Thanks, 64,4,e Brad Isbell, P.E. Bradley J. Isbell, P.E. 1405 W. Chapman, Sanger, Texas 76266 P 940-458-7503 F 940-458-7417 W