Loading...
HomeMy WebLinkAboutApplication-PermitProject Address 603-23-32 DEBEQUE, CO Owner Information Garfield County Building & Planning Department 108 8th Street Suite 401 Glenwood Springs, CO 81801 - Phone: (970)945-8212 Fax: (970)384-3470 Parcel No. Permit NO. B LC O-'10-114243 Permit Type Commercial Building Work Classification: New Permit Status: Active Issue Date: 11115/2011 Expires: 01/01/2999 I Subdivision Section Township Range 216904400003 Address Phone CeII OXY USA WTP LP CO Contractor(s) Phone Primary Contractor Proposed Construction 1 Details 6 Pre fabricated employee house structures FEES DUE Fee Amount Commercial Building Fee $492.25 Manufacture Fee $600.00 Plan Check Fee $319.96 Total: $1,412.21 Valuation: Total Sq Feet: $ 34,992.00 4872 FEES PAID Inv Total Paytype Amt Paid Amt Due Inv # BLCO-10-11-21453 $ 1,412.21 Credit Card Credit Card $1,033.16 $379.05 $ 0.00 Required Inspections: For Inspections call : 1(888)868-5306 Inspection IVR See Permit Record Building Department Copy Tuesday, November 15, 2011 2 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 ( inspection Line: 888-868-5306 www.garfield-county. cern OCT 1 0 O11 1 Parcel No: (This information is available at the assessors office 970-945-9134) 216904400003 2 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description NESW Sec 10 T6S R97W WELL PAD NO. 603-23-32 3 Lot No: Block No: Subd./ Exemption: 4 Owner: (property owner) OXY USA WTP LP Mailing Address: 760 Horizon Dr. Suite 101 GJ, CO Ph: 970.263.3668 Alt Ph; 970.985.1835 5 Contractor: n/a Mailing Address: Ph: Alt Ph: 6 Architect / Engineer: ilia Mailing Address: Ph: Alt Ph: 7 Sq. Ft. of Building: 6plex = 4,872 Sq. Ft. or Acres of Lot: 1,053 Height: No. of Floors: 8 Use of Building: Minor Temporary Employee Housing 9 Describe Work: pre -fab structures, Colorado Department of Housing Certified 10 Class of Work: ix New o Alteration o Addition 11 Garage: u Attached n Detached Septic: approved Err ISDS ❑ Community 12 Driveway Permit: exempt per Rd and Bridge Owners valuation of Work: $ 363,841 Authorit\. This application for a Building Permit must be signed by letter of authority, signed by the Owner, must be provided A Building Permit cannot be issued without proof of legal NOTICE the Owner of the property, described above, or an authorized agent. If the signature below is not with this Application. and adequate access to the property for purposes of inspections by the Building Department. Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified Discharge Permit. authorized is not commenced within 180 days of the date of issuance and if work is suspended or CERTIFICATION contained above is true and correct. I understand that the Building Department accepts the Application, based upon my ecrtifcatiuu as to accuracy. a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and my agents will comply with provisions of any federal, state or local law regulating the work Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice are not in compliance with County Regulasion(s) or any other applicable law. described above, to inspect the work. 1 further acknowledge that the issuance of the Building if any, discovered after issuance; or (2) stopping construction or use of the structure(s) work by the Building Department do not constitute an acceptance of responsibility or liability compliance with federal, state and local laws and County Regulations rest with me and my authorized that of the Owner, a separate above, c -g. State or abandoned for a period of 18f1 along with the plans and facilities detailed on and the Garfield County Building from the County, if the location, Permit does not prevent the or foeility(iet) if such is in violation by the County of errors, omissions agents, including without Leval Access. Other Permits. Multiple separate permits may be required: (1) State County Highway! Road Access or a State Wastewater Paid Permit. A Building Permit becomes null and void tithe work I hereby certify and specifications Assuming the submittals In consideration Code, ISDS construction 1 hereby grant Building of County Review of or discrepancies. limitation i HEREBY days after commencement. that 1 have read this Application and that the information and other data submitted by me or on my behalf (submittals), completeness of the submittals and approval of this Application, reviewed by the Building Department. of the issuance of the Building Permit, I agree that 1 regulations and applicable land use regulations (County or use of the structure(s) and foci lity(ies), described above, permission to the Building Department to enter the property, Official from: (1) requiring the correction of errors in the submittals, Regulation(s) or any other applicable law. this Application, including submittals, and inspections of the As the Owner. I acknowledge that responsibility for my architect designer, engineer and! or builder. ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: J /0//120/) OWNERS SI A,.43 DATE i J , r Plum' 1b -40-i i �J'r f/0 • / l/ /5 // V/ i STAFF USE ONLY Special Conditions: �" } } Adjusted Valuation: 39I99Z,00 Plan Check Fee: 519.96 Permit Fee: LI9z.zS Manu home Fee: 600 Misc Fees: ------ ISDS Fee: Total Fees: i, I z . z- / Fees Paid: TO •05 Balance Due: 1/ (235. /6 BP No & issue Dale: ISDS No & Issued Date: l c0 -Pal -I3 a P+- any Setbacks: rico g rooSlog OCC Group: g 5 Const Type: _ Zoning: RL / BLDG DEPT: /, PLNG DEPS ! /,I /7 APPROVAL DATE APP OVAL DATE 4. Building Plan Review Description of Work: 6 Pre fabricated employee house structures Bin #: Location Address: DEBEQUE,CO General Information Contacts Case Manager: David Bartholomew Plan Case Number: BLDG -10-11-7018 Parcel: 216904400003 Application Date: 10/10/2011 ti Owner: OXY USA WTP LP Applicant: OXY USA WTP LP Applicant Phone: Email: Building Engineered Foundation Driveway Permit Surveyed Site Plan Septic Permit and Setbacks Grade/Topography 30% Attach Residential Plan Review List Minimum Application Questionnare Subdivision Plat Notes Fire Department Review Valuation DeterminationlFees Red Line Plans/Stamps/Sticker Attach Conditions Application Signed Pian Reviewer To Sign Application Parcel/Schedule No. % 40# Snowload Letter - Manu, Homes Ni Soils Report Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building height 1 Toning Sign -off Road Impact Fees HOA/DRC Approval GradelTopography 40% Planning issues -Subdivision Plat General Comments: IS7t72/ ge-wax)/ e f ziP set A-01- /'d 5y,.'97.co 4/9 2.. 600 ,06 /9i2.27 79,° /i 5 3./h Monday, November 14, 2011 J The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. f4/?1a vet OWNERS SIGNATURE DATE Bapplicationdecember2007 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI -FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. 1 Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2009 IBC, 1PC, IMC, IFGC, and IFC, 2009 IECC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes x 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes x Not necessary for this project 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes x 4. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? Yes if Yes please provide a COPY. No x submitted same day 5. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes Not necessary for this project x 6. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes Not necessary for this project x 2 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the building code or per stamped engineered design? Yes Not necessary for this project x 8. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes Not necessary for this project x 9. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes Not necessary for project x 10. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes Not necessary for this project x 11. Do the plans include design loads as required under the IBC or IRC for roof snowloads, (a minimum of 40 pounds per square foot in Garfield County)? Yes x Not necessary for this project Colorado Blue Cert 12. Do the plans include design loads as required for floor loads under the IBC or IRC? Yes Not necessary for this project x 13. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes Not necessary for this project x 14. Is the wind speed and exposure design included in the plan? Yes Not necessary for this project x 15. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes Not necessary for this project x 16. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes Not necessary for this project x 3 17. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Yes Not necessary for this project x 18. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Yes Not necessary for this project x 19. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? Yes Not necessary for this project x 20. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IBC or IRC? Yes Not necessary for this project x 21. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes Not necessary for this project x 22. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes Not necessary for this project x 23. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes No Not necessary for this project x 24. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Chapter 3) Yes x Not necessary for this project 25. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes Not necessary for this project x 26. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes Not necessary for this project x 4 27. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes Not necessary for this project x 28. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes Not necessary for this project x 29. Have two (2) complete sets of construction drawings been submitted with the application? Yes x 30. Have you designed or had this plan designed while considering building and other construction code requirements? Yes x 31. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes x 32. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For corner lots see supplemental section 3-301 in the Garfield County Zoning Resolution for setbacks. Yes x 33. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes x 34. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes x 35. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes x 36. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes x 5 37. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30 a.m. and 3:30 p.m. Monday through Friday. Inspections are to be called in to 888-868-5306. Yes x 38. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re -inspection fee? Yes x 39. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway Permit including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See Phone book for other agencies Yes x 40. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes x 41. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number for the lot you are applying for this permit on prior to submittal of the building permit application? Your attention in this is appreciated. Yes x 42. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes x (Please check with the building department about this requirement) 43. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes Not necessary for this project x 44. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and specifications for the project. Yes Not Necessary for this project x 45. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes n/a 6 I hereby acknowledge that 1 have read, understand, and answered these questions to the best of my ability. Signature i°1 11011 Date Phone: 4.412- ac3 -36 a' (days); t% {� (evenings) Project Name: FY) ;n TER 03 - 05 - 3 1 -- Project Project Address: V Sw Sic la f6 S R91-0 co,-kk,, c,r, Note: On any of these questions you may be required to provide this information. If required information is not supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. bpminrepcommJun2010 7 LAND USE CHANGE PERMIT MTEH 10-11-7017 for One Minor Temporary Employee Housing Facilitylocated on property owned by OXY USA WPT LP on a natural gas well pad described as 603-23-32 with API No. 045-10856-00 Parcel Number: 2169-004-00-003 In accordance with and pursuant to the Garfield County Land Use Resolution of 2008, as amended, ofthe Board of County Commissioners of Garfield County, State of Colorado, the Director of the Building and Planning Department hereby authorizes, by Land Use Change Permit, the following activity: The installation of one Minor Temporary Employee Housing Facility located in SW1/4 of Section 3, Township 6 South, Range 97 West, 66 P.M, Garfield County, Colorado The Land Use Change Permit is issued subject to the conditions set forth in Exhibit A (attached hereto) and site plan attached as Exhibit B, and shall be valid only during compliance with such conditions and other applicable provisions of the Garfield County Zoning Resolution, Subdivision Regulations, Building Code, and other regulations of the Board of County Commissioners of Garfield County, Colorado. BUILDING AND PLANNING DEPARTMENT, GARFIELD COUNTY, COLORADO Exhibit A Section 7-808 (D) (2): The applicant shall adhere to the following Minor Temporary Employee Housing Facility Characteristics and Standards: a. Minor Temporary Employee Housing Facilities, in the nature of Factory Built Nonresidential Structures [as defined under C.R.S. 24-32-3302(a)] and/or recreational vehicles [as defined under C.R.S. 42-1-102 (61), with the addition that such truck, truck tractor, motor home or camper trailer is being used for temporary living quarters and not recreational purposes]; may be granted land .use approval for projects related to commercial, industrial and mineral extraction operations by the Building and Planning Department Director (Director), through the Minor Permit process. Such housing shall be of a temporary nature, and at the expiration or other termination of the Minor Permit,all structures, foundations and associated Infrastructure shall be completely removed. Such facilities are subject to all applicable requirements of Garfield County building and fire codes (building code, fire code), state and federal permits and relevant fire protection district(s) fire code requirements. Minor Permits shall have all of the following basic characteristics: 1) The Minor Temporary Employee Housing Facility and any associated infrastructure ("Minor Facility(ies)") must be completely contained within a state or federally permitted parcel (i.e. Colorado Oil and Gas Conservation Commission (COGCC) approved oil/gas well pad) in which reclamation and revegetation are secured with the permitting agency (Permitted Site); and, 2) The Minor Facility is located ata Permitted Site for Tess than a cumulative of one (1) year, and, 3) The Minor Facility shall have occupancy of nine (9) to twenty-four (24) people who are employees, contractors or sub -contractors of the operator and are safety of the related commercial, industrial, extraction or highway operations. Temporary employee housing facilities that do not have the three characteristics listed above, i.e., have an occupancy of eight (8) or fewer people or 25 or more people, on location for more than a cumulative of one (1) year or not completely contained within a Permitted Site, i.e. "Small Facility" or "Major Facility", are subject to the Major Impact Review process and standards and requirements contained in Article 7-808(D)(1-3) and the enforcement provisions of Article XII. b. The Minor Facility shall adhere to the following Minor Permit standards: 1) Minor Facilities must comply with all applicable federal, state and local laws and regulations. 2) Operator must keep and maintain appropriate records, to be provided to the County or any interested third party upon request, to demonstrate that potable water supplied and sewage and wastewater meet the representations contained within the application, as required. 1 3) In no case shall unsafe water be used for drinking nor shall raw sewage or contaminated water be discharged on the ground surface. The operator shall conduct monthly tests (or quarterly if an on-site disinfection system is installed) and maintain records of potable water samples specific for coli form bacteria. Any tests indicating coli form contamination must be disclosed to the Garfield County Board of Health or designee within 72 hours from the time the contaminated water was tested. 4) Minor Facilities shall be maintained in a clean, safe and sanitary condition, free of weeds and refuse. Any hazardous or noxious materials that must be stored at the Minor Facility for operational or security reasons must be managed in accordance with all applicable federal, state and local laws and regulations. 5) At least one thirty (30) gallon (4 cubic feet) wildlife -proof refuse container shall be provided for each factory built nonresidential structure or recreational vehicle unit. Said container(s) must be durable, washable, non-absorbent metal or plastic with tight -fitting lids. 6) Refuse shall be disposed of weekly, at a minimum. Operators must keep appropriate records, to be provided to the County or any interested third party upon request, to demonstrate that refuse is collected in a timely fashion and disposed of at a licensed facility. 7) Outdoor food storage is prohibited unless facilities that prevent the attraction of animals to the Minor Facility are provided. 8) Factory built nonresidential structures or recreational vehicle units equipped by the manufacturer with a fire sprinkler system, fire detection system, and/or alarm system shall be inspected, tested, and maintained in accordance with 2003 IFC 001.4 and §901.0 or subsequent adopted fire code and as required by the relevant fire protection district(s). Smoke alarms and manual fire alarm systems shall be installed, inspected and maintained in all other factory built nonresidential structures or recreational vehicle units in accordance with 2003 International Fire Code (IFC) §907.2.9 and §907.2.10 or subsequent adopted fire code and the requirements of the relevant fire protection districts. 9) Single -station carbon monoxide alarms shall be placed in each factory built nonresidential structure or recreational vehicle unit. 10) One (1) or more approved fire extinguisher(s) of a type suitable for flammable liquids, combustible materials and electrical fires (Class A, Class B and Class C), or dry chemical, shall be located in each factory built nonresidential structure or recreational vehicle unit and placed in accordance with applicable codes. 11) Inhabitants of the Minor Facility shall be Temporary Employee Housing Operator's employees and/or subcontractors, working on the related commercial, industrial or mineral extraction operation, and not dependents of employees, guests or other family members. 12) Within 10 days following the expiration or other termination of the Minor Permit or represented date of removal identified within the Minor Permit, all housing 2 structures, foundations and associated infrastructure shall be completely removed. The Operator shall provide the Department with photos, dated and signed by the Operator's Compliance Officer, indicating that all housing structures, foundations and associated infrastructure has been removed within the specified timeframe. 13) No domestic animals are allowed at a Minor Facility. 14) A water storage tank shall be required to provide water to the sprinkler system and initial suppression activities. The size of the water tank shall be determined based on sprinkler calculations and initial suppression demands. The size of the water storage tank shall be determined by the relevant fire protection district. If the Minor Facility is located outside the boundaries of a fire protection district, than each Minor Facility shall have at least one (1) water storage tank with a minimum of 2,500 gallons of water for initial fire suppression, operation of sprinkler systems (if applicable) and wild land fire protection. 15) All emergency situations requiring action by any government agency or fire protection district shall be documented in writing and presented to the Planning Department and Garfield County Sheriff's Office within 24 hours of the occurrence. 16) All required Access Permits shall be obtained from the Garfield County Road and Bridge Department or the Colorado Department of Transportation. 17) The Garfield County Sheriffs Office and relevant fire protection district(s) must be noted at least 24 hours prior to installation and removal of each Minor Facility. The Department shall be copied on all such notification, whether hard copy or electronic. 18) The Operator shall maintain records identifying workers, whether employees or sub -contractors, and documenting the dates that each worker is housed at the Minor Facility. Such records shall be provided to the County or any additional third party upon request. 19) Wastewater Disposal: (a) Vault System: All vault systems shall be designed and installed to accommodate the maximum number of persons, identified within the Minor Permit application, who will inhabit the Minor Facility. In addition, all vault systems shall be equipped with an overflow alarm device. Vault systems shall be designed •to accommodate a minimum of 75 gallons of wastewater per person per day. If a vault system is proposed or has been approved, the Temporary Employee Housing Operator/Operator must: (1) Demonstrate that year-round vehicular access is available and maintained for safe and regular access for sewage hauling vehicles. (2) Provide a copy of the contract for hauling sewage. (3) Maintain all sewage disposal records including but not limited to trip logs/reports and landfill receipts as public records, available to the County and/or any other interested third party upon request. 3 (4) If the total waste production from a facility will be 2,000 gallons per day or greater based on a production of 75 gallons of wastewater generation per person per day, then the facility shall be serviced by an ISDS installed as per State standards. Hauled sewage and wastewater service shall not be permitted for any facility which will generate a total of 2,000 gallons or greater of wastewater and sewage per day. (h) Individual Sewage Disposal System (ISDS): If an ISDS is proposed or has been approved, then it shall be . designed, installed and operated to accommodate the maximum number of persons who will inhabit the Minor Facility and shall otherwise be operated in accordance with the Garfield. County ISDS regulations as contained in Resolution 2008-82. 4 Exhibit B Colorado Division.' -of Fire Safety Fire Siippression t'AIrrrrApproval Form f - CFS Fire, ippress c Program 690 Ki ON Street, §te 2coq La oqd, CO. 0215;` Phone- . rr - 303-239-5887 Finail - gtev0:66, owskiddps stafe.co.us Apprav d Plans qn site , Y O N 1 Permit # 4/4 Systetir Tyree (Check all that apply) Underground Instal! E:1'• 'HydrolF1'ush.D Sprinkler. 13 rEf 11R ❑ 13fD ❑ multi '❑ Reugh-In '0' Re-Jnspection Q : Fi�iaUCaQ. Fire limp Cgrrrrnissio ..0. Ftc F her . Install Type New❑ :_R ra Tenant_FInis l .� - pair a kteerabon: Date of Inspection: )J- J1' it, Time In: C.%. Project. Name: '.AA•#6fl40‘`:-+0-[ Project/Site Address: D x j *lip 3 - 2-332_ ..1a-vc Fire Jurisdiction: Sprinkler Contractor: " u 4 Alarm Contractor: —7(1..1- qty Registered Fitters' Reg. Number Apprentices' Reg. Number Certified Inspector: - c�, w•eS.�i. _ Certification #: 95—S-64 1 a 3 Time Out: 13ac..) Inspector Notes NFPA 24 Test & Form: Y ❑ N ■ Pump Comm. Y 0 Hydrostatic Test Results: 200 psi for 2 hours. Passed? Main Drain Test Results: Static psi Residual N ■ NA 0 Name: Y riikN ■ �psi Flow Switch Time: Z-1 sec. Z-2 sec. Z-3 sec. Supervisory Controls Passed? Y ■ N 0 Pressures; Supply Static psi System Static psi Air Static (if applicable} _psi Electrical Rough -In: Y ❑ N 0 NFPA 72 Inspection & Test Form: Y ❑ N ■ i. L res + ;:-.L.....-..1_,, : z.'tee gx )`e y tkli4 t. k 1 2• f` i• -t. A1�p..44-,.....d.,..(: •4 IU cue,. u`:. -t Na.. .tieLe.‘.&14.. Li- 4.e...J. ' ' .....4 L... 4 1/4 P I.ert., ..k Pi.....A.4) — Als pa -04.4 , ;i. k 4- ..k 1.4014. 4`i-- • "44.,--,,aci-K- - — &j Installation meets approved plan design? Y Io1 N 0 All materials meet approved design spec? Y 2i 0 Installation Approved? Y 1►SI N 0 ppshall Re -Inspection Date: Time: All identified code discrepancies must be corrected, rednspected, and approved by a certified suppression inspector before the work Is covered up or the structure Is occu val as a result of this inspection construed to be provai of a Notation of the provisions of the or of otherordln of the Jurisdiction. _ ,,e Certified Inspector Date: _1r -N -I/ Responsible Party Date: Inspection Report Page 1 of I COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT / CORRECTION NOTICE Date Received: 15-NOV-11 Permit Number: 714769 Contractor/HomeOwner: Address: Type of Inspection: Action: Comments or Corrections: BRAD'S ELECTRICAL SERVICE 603-23-32 PAD Complete Final Accepted Inspectors Name: Norman Peck Phone Number: 877-320-9150 Date: 17-NOV-11 COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https://www.dora.state.co.us/pls/real/Ep_Webjnspection_GUI.Process_Page 11/18/2011 Permit NO. DLCO -10-11-2243 Permit Type: Commercial Building Work Classification: New POST ON SITE Issue Date: 11/15/2011 Permit Card Garfield County Building and Planning Department 108 81h Street, Suite 401 Glenwood Springs, CO 81601 Phone: (970)945-8212 Fax: (970)384-3470 Expires: 01/01/2999 AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Commercial Building Parcel #:216904400003 Owner's Name: OXY USA WTP LP Job Address: 603-23-32 DEBEQUE, CO Owner's Phone: Total Square Feet: 4872 Contractor(s) Phone Primary Contractor Work Description: Inspection Scheduling Code Inspection IVR Comments Pass Date FIRE DISTRICT INSPECTIONS (PLEASE CALL FIRE DISTRICT) Footers 105 Foundation Walls 110 Framing 115 Drywall 120 Final 125 (59/4-i �, �// 717/1—) 17 °—) / / f1'Jii'r-/ Misc 135 Insulation 160 Grout 175 Mechanical 405 UG Plumbing 605 Rough Plumbing 610 Gas 620 ADDITIONAL INSPECTIONS MAY BE REQUIRED POST THIS IN CONSPICUOUS PLACE WHEN CONSTRUCTION IS STARTED For Inspections Call: 1-888-868-5306 Account Page 1 of 1 Account: R290107 Location Parcel Number 2169-044-00-003 Situs Address City D'ebeque ZipCode 81630 Tax Area 029 - J-49HBDF - 029 Legal Summary Section: 4 Township: 6 Range: 97 SEC. 3 LOTS 6,7,8,9,10,11,14,15,16, SW SEC. 4 LOTS 10,11,12,13,14,15, SE, E1/2SW Transfers Sale Price $684,500 Tax History Tax Year *2011 2010 * Estimated Taxes Owner Information Owner Name OXY USA WTP LP Owner Address 5 GREENWAY PLAZA, SUITE 110 HOUSTON, TX 77046-0506 Sale Date 06/24/2008 12/15/2006 12/1512006 12118/2006 Images • (AS $69.16 568.56 Doc Type EAS OCD QCD PRD Assessment History Actual (2011) $7,920 Primary Taxable $2,300 Tax Area: 029 Mill Levy: 30,0720 Type Actual Assessed Acres SQFT Units Land 57,920 $2,300 1053.080 0.000 0.000 Book Page B: 1876 P: 764 B: 1876 P: 760 B: 1876 P: 752 https://act.garf eld-county.com/assessor/taxweb/account.jsp?accountNum=8290107 10/10/2011 APPROVED SUBJECT TO NOTED gXCE.: TIONS & P1iSPECTIi S/ GARFIELD COUNTY BUILD TG Date// /%/l By LDC•PY LNSPEC ITON WITRM THESE MANSON Pam OXY USA WTP LP 6plex emp hsg a DeBeque 603-23-22 BLCD-10-11-2243 SEPT -10-11-2244 CONDITIONS OF PERMIT BLC3-10-11-2243 OXY USA WTP LP Minor Temporary Employee Housing Well Pad 603-23-32 DeBeque, Colorado 1) ALL WORK MUST COMPLY WITH THE 2009 IBC, IPC, IMC, IFGC, IECC, IFC AND MANUFACTURERS INSTALLATION SPECIFICATIONS. 2) ALL WORK MUST COMPLY WITH THE CONDITIONS OF THE LAND USE CHANGE PERMIT MTEH 10-11-7017. 3) ALL WORK SHALL COMPLY WITH STATE AND FEDERAL REGULATIONS. 4) LOCAL FIRE DISTRICT SHALL INSPECT FIRE SUPRESSION SYSTEM, EXTINQUISHERS, AND OTHER PERTINENT IFC REQUIREMENTS. FIRE DISTRICT FINAL APPROVAL LETTER IS REQUIRED FOR CERTIFICATE OF COMPLETION. 5) ELECTRICAL FINAL APPROVAL IS REQUIRED PRIOR TO CERTIFICATE OF COMPLETION. 5) SEPTIC FINAL APPROVAL IS REQUIRED PRIOR TO CERTIFICATE OF COMPLETION. 7) LOCKS, LATCHES AND LANDINGS PER 2009 IBC, SECTION 1008. 8) LIGHT AND VENTILATION PER 2009 IBC, CHAPTER 12. OF'/ c GOP`' SCALE: 1"• LOW INSTALL SEAR PROOF TR CCIK NFO 0451150 RPEUNE ELM/ 6609. ;`/ ;resrumansrm , mlc�r.rs+cN INSTALL INTER LAM METALL CENERAATT R INSrALL6 UNIT MRL GAWP PROPOSED DRILL CAMP RAD 83 POSITION: 39" 32.53.563' NORTH 108"12'38.831" WEST 1N3TALL SEPTIC SNICS TEMPORARY EMPLOYEE HOUSING /457450 2800 GALLON WATER Fd NL FOR IFLDLANO FIRE SUPPRESSION DRIVING DIRECTIONS FROM SHE TOWN OF DFRFOLIF: BEGINNING AT THE INTERSECTION OF ROAN CREEK ROAD (4mE5A COUNT1 ROAD 45) AND INTERSTATE HIGHWAY 50 70 AT EXIT N0. 62 SOUTH OF THE 10811 OF DEBEOUE, MESA COUNTY, COLORADO; TRAVEL NORTHERLY ON ROAN CREEK ROAD (6055 COUNT1 ROAD 45) FOR 4.0 MILES TO THE !VESA-GARFIELD COUNTY LINE_ CONTINUEON ROAN CREEK ROAD (GARFIELD COUNTY ROAD 204) FOR 4.35 MILES TO CONN CREEK ROAD (GARFIELD COUNTY ROAD 213). TURN RIGHT AND TRAVEL EASTERLY AND NORTHERLY FOR 3.9 MILES 10 THE 0%Y ROAD ENTRANCE AND CUARD SHACK. END TRAVFI ON MIMIC ROADS AND RFCIN TRAVFI ON PRIVA7E ROADS THEN CONTINUE NORTHERLY AND NORTHEASTERLY 8.65 MILES TO A "'I- NTERSECTION WITH AN EAST -WEST ROAD. THEN TURN RIGHT AND TRAVEL EASTERLY FOR 0.4 MILES TO A "Y" INTERSECTION WITH A NORTH -SOUTH ROAD. THEN TURN LEFT AND TRAVEL NORTHERLY FOR 2.4 MILES TO THE ACCESS ROAD TO THE CASCADE CREEK 003-23-32 PAD THEN TURN RICHT AND TRAVEL SOUTHEASTERLY FOR 0.2 MILES TO THE LOCATION. SURVEYORS STATEMENT 1, DAV10 E. HENDERHAN, AN EMPLOYEE AND AGENT FOR D. R. GRIFFIN & ASSOCIATES, INC- STATE THE SITE PLAN SHOWN HEREON 15 A CORRECT REPRESENTATION OF THE RESULTS OF A 508500 MADE UNDER MY AUTHORITY ON MAY 11, 2041 FOR THE PROPOSED CASCADE CREEK 603-23-32 TEMPORARY EMPLOYEE HOUSING. COLORADO PL5 No 38409 FROM THE TOWN OF PARACHUTE: BEGINNING AT THE INTERSECTION OF GARFIELD COUNTY ROAD 315 AND INTERSTATE HIGHWAY N0. 70 ON THE EAST 5111E OF PARACHUTE. GARFIELD COUNTY, COLORA00, TRAVEL NORTHWESTERLY ON GARF1ELD COUNTY ROAD 315 FOR 7.3 MILES TO THE GARDEN GULCH ROAD 1uRNOFF ENO TRAVEL DN_PUBLIC ROADS AND BEG1N TRAVEL ON PRIVATE ROAD5. TURN LEFT AND TRAVEL NORTHERLY AND WESTERLY FOR 0.65 MILE TO THE LOWER WLUAMS GUARD SHACK. THEN 00511NUE WESTERLY 5.6 MILES TO THE UPPER WLLIAMS 00ARD SHACK AND A "Y"INTERSECTION BEAR LEFT ON AND TRAVEL 2.1 MILES TO A "T" INTERSECTION. CONTINUE STRAIGHT (BEARING RIGHT AT THE 'T") FOR 2.85 MILES TO A "Y" INTERSECTION REARRICHT AND TRAVEL NORTHERLY FOR 2.4 MILES TO THE ACCESS ROAD TO THE CASCADE CREEK 603-23-32 PAD. THEN TURN RIGHT AND TRAVEL SOUTHEASTERLY FOR 0.2 MILES TO THE LOCATION. /4 P'O HOUSING i+{ PARAC7r`U7E if:n 111 r(A(1(7cot 11F51 CO( R7} COL)I(971Dt PUBLIC ROAD PRIVATE ROAD 7 PUBLIC ROAD ROUTE TO 511E PRIVATE ROAD ROUTE 70 SITE OXY PROPERTY BOUNDARY VICINITY MAP SCALE: 1".=.5000' SURFACE AND MINERAL OWNERSHIP DOS USA WTP LP 760 HORIZON DRIVE. SUITE 101 GRAND JUNCTION, COLORADO 81506 (970) 263-3437 INSTALIATION AND REMOVAL DATES 1. INSTALLATION DATE: NOVEMBER I8, 21111 2 REMOVAL DATE: NOVEMBER 17. 2012 3. CUMULATIVE TIME: 365 DAYS V ti cot ALEX JOS No. 11698 SHEET IOFI REVISED: 10/S/11 - DEH /REVISED INSTALLATION DATES DATE: 6/6/11 - TCM 24 HOUR RESPONSE CONTACT INFORMATION: ALONZO HERNANDEZ (HES SUPERINTENDENT), OXY USA WTP LP 5. GARFIELD COUNTY SHERIFF'S OFFICE, RIFLE, CO. (670) 253-3659 (970) 625-8095 (970) 980-6055 2. BEN WATKINS, (HES SPECIALIST), 051 USA WTP LP (970) 263-3658 (970) 201-2201 3. 5T. MARY'S HOSPITAL, GRAND JUNCTION, CO. (970) 244-7050 4. ST. MARY'S CAREFLIGHT HELICOPTER,. GRANO JUNCTION, CO_ (970) 332-4923 6 DEBECUE FIRE PROTECTION DISTRICT P.O. BOX 180, OEBEOUE, CO. 81630 7. DEBECUE VOLUNTEER RESCUE DEPARTMENT, OE8EOUE, CC. (970) 283-5907 ATCO s truc tures GEN tow eze VD Pool OUTPOST OFFICE 0 II i eli 1 n 44166:21. i eIi m Igi il !I 40i 0 ii 1 9 pill is grip Up 1Vg 11 E3d1 .., e livigraw Isi r rg ilaiiiiiio a 34 41 , d H r o a f d i K fi4 s 72'X54' 6- UNIT DF.ILL CAMP zt Fml 0 a 0 C T & ( § 00 it co: wf _ •:: tet ` •4 1C of X90 •••li g 9� � 1 i � N 2 1 i 4 i r 0 i 9 1:111lig iri ii i ?. 11 i t tr't •aattrat, € 2UV,R ;r .Rx I Si 4 ii 5 g k b 1 I! dihi 1 VI '' a tir' Y4 yy d UP I la_ . I 1 a iii i hIll p , g;, k k § a h il 0 4. Ili . ,.�� 11 1 I� a' I Hii 1 F EB it 1 0 UM b z+c � Lo�;t b kh :M Oplismoiat Lure latira enr ma 1 1 V ,g ff R 1 /oil 11 T ie IRE gi yig R Whig$ q'8 : i6S` 1rd so a 4 1-,� aiiliiili i 8 8 11 11111 y �? t n 73 M a V 8 a a I s s ii t7E 23 git 'i a „'J it 1113Vgli kil iiiiiigiialii i1 I ?Aid :! gE It a Malin a p1 Eif g. log i 3 ;Ai 11; 4 I i l i � jEP I �� t: `` 11tt t'trt t r'Ir Mi liMi/V43?: _ i�3 1 A i !ill MN y,,��� Rie �F g igig E q i •* i i id N64 rl #410 5 E I high ili i P 3 i a e 111111 k � 1 t' r k;q t ,rg 1$ri:2im- ,§: Mi ` a€ . lir*r aomrr _ 00 r- 0 0, Plet(orm BlOcklhg IA38- AFF to center. See detail. Aeo Pia [form .Blocking 036` AFP to coF7- 7h center. See detaiL A -+v 02 RD_ 4591,"x30.4." RO_ 48 `x3034 31L1, 6 42" AFF mu, • AFF iiOn37 ;1" RD_37}"X81" R0=37} -X01 48%"X39 SILL 2" AF -43 Re -43}"Y81} 00) 0 0-7 Blocking 6 60 For Coot Racks Typ. of 4 RO= 469f,"tdie{�" SILL, 42" AFS' -Blocking 63 for Desk "� } 0 0 a Blocking 060" for Coot Racks Typ. of 6 O. 40%"x383¢" 1LL P 42" AFF c____If Blocking ng l0 b WeI to 32 / for Desk Typ. (HO 371.X81" EC 0' co 430102 Ala m '0 iv Doors Lowered Txr into SUbfloor R0=371'X81" =43;'X81 v 0 m 1 I "y m Blocking 6 22" For Tab! Typ. of 3--- R0=61i'X37i- R0=3Ij"X31" SOL ®34 -AFF t4013- 1) 0 Blocking 6 301" For Shelved Above 0,v Table Tap. of 3 .43i -X61 0, R0=37}"XBr 0 43i•,B1t w 0, 0 1 M Doom Lowered rxr into S obtlocr m 00 0, R0=6l.} 137 ' SILL 0 34"AFF <s bi r`m 01 0 RO- 483'0"x391 s1iL 19 42" m 01 i- co N Blocking 0680 far Cont Racks r P. • t,•43f x9ii 1r 'r Jo- t:'ij i I Ef� m • "+or"151; I I -mock n OHO':r for Shelve.,I: 1'-2 " -37 "YETI co S' ~ -11�'�`,`,' ys1LL GBlacking 4,5%-x393§" 00 J' 42" OF 11x,2 for Desk :".=37i"X6f" ' ![i!{� ;i X43}"xbfi fL Blocking for •' RO=37}"1®1` --^Z—_ •_-- I Hands f -, 1 Blocking 61 •' RO=37}'7CBt" I1�I� for 3' Rack Blocking 06B://)1 for 3' Rack (j ►v ■ !y� {`y! I I�IIR 0..431"03I} DBL 2X6 HEADERO, H EDGE 10.— 7 ADD FLAOR JOIST IN THLS ARE. TO BE 0" 0.C. D oors Lowered rx2" into Subfloor m N et. 01 —r 00 160 R 7:f1 A1L,�NGRY$EfB6it. EXCL P NiigN FINISHED ARE DRAWN AT 5-1/R" UNLESS OTH XS OTEiERwilp 0TEU ALLS ARE DRAWN AT 3-1/2" UNLESS 0�'H�yE{� 0Ery1NgOTRE 35 ARE t 7A�WpA? FRO1ppWALL UNLESS h4 Opf E17C ISETSSROTttERHISE NOTEQ. ERS TO 66 DOUBLE 8 —1 • 6.-10" o `SC AL p &1:171 p i4\`'rases WALL LEGEED. L 1 -RAIL HEIGHT 70 BC B'-10 72Z2 -TALL HEIGHT TO SE 0MDT 133111 ;01 Pt MAL t Wan =LK MR Al 10613 1 ..10.0 MUG' Fa ri0OV 17011 Y,1f51 DATE M4Ut rap PM PA0 C C C Ci - ACCEPTASdE As moot! 17 " ACCe1TANCF EZCEPr AS 007t 01? EICOPYPIGHT 2000 OLE 0IGN770 RESTF0EL ...Mb ATM STTtVCTUxEO {t1s4) BIL. 1100 NOx070 TEMPLS 00400 61801-. TEXAS 76001 0000 BL'RICeVRHET0 MAO 1nektrA FALLS. TEAS 70300 SPECTICAOTO0 NUL BER 608-025 moon sr. G9 DATE D•R 3000IV4 x.10 00,7057 OF 10E e-00100 EALLL coo 011501, 711101 COHSTMk"n0N PACE !OTOS PROW Aa 93F'. -r:: er.^ =311.10) . Tr 0 rx2" Into Sub(loor civ la n B oaking 980" lot Coat Racks Tpp. of 8 RO- 483'0"k391y" Ni* SILL ® 42" AFF L ----Stocking 4932' kir Desk Typ. V7 (1 '0 i"1331" m 00 r—alp' ea 00 0=3i}"7031 we Nom Platform 03acktng 636' AFF to center. Ste Cord detnil. 0 th RO= 48%-)0111i" SILL. 48 42" AFP 1) Blocking 632" for Desk Both Sides 0 00 0) 1'-7 — r 37}"7B1" OM. ti Ara 40 0 R00.371"281 - RO- 463;"x3934 SUL 18 42" AFF O 374"7® 0 0 rx2" Into Subtloor a RDa 4630"x393 SILL Sm 12"AP Platform Blocking 036' AFF La center_ See detalL4,t O • . g qp y�p��N t .LSU NTS G L( E7[CEPT WHg, FA A141NG E FINLS}1E0 •i A >.y N{: AILS ARE DRAWN AT 5-1/2" UNLESS &riSN'ft�lpiss�:A;�D(WALL4 ARE DRAWN AT 3- 1/2` UNLESS ArtSEO NOTEL7BS ARE 3" AWAY FROM WALL UNLESS 2R4 OH EDGEIGR I6EOpROTHEAA[580HON"R5 TU BE F19UBLE 7'-R" 8'-]o" 7.-6" -r in vF`tm 'b J:i: . e] li y i C ] I� Door Blacking DaLeil-6 - VjALLLMEND (15 ( "7 -WALL HEIGHT TO 8E 8'-10- j Cat//✓fd -WALL HEIGHT TO 9E - et I c�7 m Doom lowered 1 "7L2" Into - Subticor y a a I C AA" W Doom Lowered -1 Ta- into "" Subroor 3OCC13 CoT10rt NYB VER 1 _ O - ACCLPgA icr A8 DRAWN ❑ - ACCEPTUlCZ E1003',T AS NO 8T. 606-025 i0.45}"X/31 _ •---ammo • 431•X81 r Coat Racks i 0 1111 /e) lip I 1. 0✓ � ill , WSW LS9UT WA 190 04i. 4' 110.0N 9r L9 0001010 OUTPOST or{1CC 1- i1NIT 0FRL1.L Oat.. 1OLLI t R0- 48 'x393¢' 42" AFF' G1 n waJ _ RD- }`XBi " R0=37}"1191 vi SF 6 7}' 8' LO " o{4 1' waoN " a 'leA5W�4 90.• C'AR.r s _ f1 ' r t 3E1" ©- _.. ..r.i a 3/1C. r o." __",..__ - » . -" king 632 ger • _ .. " `-1 Desk r ( ri R0-370-gEgi Ro-37}"X81 D IM Il i i, i ( j .. .I "L1 , a1 �e 1P11 7r RA 'ill+a43}"X81 ��+.r-�• .....-........ ,. 0=43}`X$1 4 l - I n I `t LO -'01a M Nom. I l� 1 F ['1 m V M - n O _ I N .!...p N �KV nI IN .-�1 [�j �.. . ~•P m N I - m... -. p 0 rx2" Into Sub(loor civ la n B oaking 980" lot Coat Racks Tpp. of 8 RO- 483'0"k391y" Ni* SILL ® 42" AFF L ----Stocking 4932' kir Desk Typ. V7 (1 '0 i"1331" m 00 r—alp' ea 00 0=3i}"7031 we Nom Platform 03acktng 636' AFF to center. Ste Cord detnil. 0 th RO= 48%-)0111i" SILL. 48 42" AFP 1) Blocking 632" for Desk Both Sides 0 00 0) 1'-7 — r 37}"7B1" OM. ti Ara 40 0 R00.371"281 - RO- 463;"x3934 SUL 18 42" AFF O 374"7® 0 0 rx2" Into Subtloor a RDa 4630"x393 SILL Sm 12"AP Platform Blocking 036' AFF La center_ See detalL4,t O • . g qp y�p��N t .LSU NTS G L( E7[CEPT WHg, FA A141NG E FINLS}1E0 •i A >.y N{: AILS ARE DRAWN AT 5-1/2" UNLESS &riSN'ft�lpiss�:A;�D(WALL4 ARE DRAWN AT 3- 1/2` UNLESS ArtSEO NOTEL7BS ARE 3" AWAY FROM WALL UNLESS 2R4 OH EDGEIGR I6EOpROTHEAA[580HON"R5 TU BE F19UBLE 7'-R" 8'-]o" 7.-6" -r in vF`tm 'b J:i: . e] li y i C ] I� Door Blacking DaLeil-6 - VjALLLMEND (15 ( "7 -WALL HEIGHT TO 8E 8'-10- j Cat//✓fd -WALL HEIGHT TO 9E A-4700 OZPERIfilif'1A1' :'.it;i'?"0TI.03`S. - --4NOf� G�}ST4MER ACCEPTANCE OCOOYAICi' 20010 ALL MOM 3F30.R5 0) 0010 Ata1 S1Rt]C11,5V13 OSA) NC, 1111 ROM 'rC4P1E ran 0!4021. 18%05 'tb7.1 24DG BUSSBUONER ROAD 000141'0 i'ALLS. 7E2AS 74300 3OCC13 CoT10rt NYB VER 1 O - ACCLPgA icr A8 DRAWN ❑ - ACCEPTUlCZ E1003',T AS NO 8T. 606-025 10.0110 Illte C0MS7auCTION PAGE VNT[9 1 WSW LS9UT WA 190 04i. 4' 110.0N 9r L9 0001010 OUTPOST or{1CC 1- i1NIT 0FRL1.L Oat.. 1OLLI t LAnv, tll00 160 b 00010 G1 n waJ iJATF - en, 300cme waoN mw r*0 0*0000a0e 'leA5W�4 90.• C'AR.r s _ f1 ' r t VOL'. ;..vs to-+ r�-am _____ ..r.i a 3/1C. r o." __",..__ _.".,--.__..-. A-4700 OZPERIfilif'1A1' :'.it;i'?"0TI.03`S. r ^ / / / / ,/er GYPSU L `Aa (J a 5 12-0" t2•_ P" NMI 11111111111111111111111111111•11•111111.1110 �-- ATTIC TURBINE9 8- 255 CFM ® 4MFH WIND 2 REG'D PER NODULE 12'-0" Plenum Wail: 2X4 WOOD PLENUM WAI,£, Roof Fronting. 2221 (2 SW ® 18" O.O. Insulation: R-30 UN -FACED CAVITY FV.TP5 Transvarse Slope: 2x0 • 18' O.C. TRANSVERSE SLOPE Ceiling: 224 T -GRID SUBPE'NSED CEILING Roof Skinning: .045 £PDM W/ TERMINATION STRIP TO PERIMETER Root Sheathing: 1/2" 002 PLYWOOD Root Flniah: 5/8" TYPE X• GYPSUM TO UNDERSIDE OF RAFTILCi..t�� AR vapor Barrier: a -Mf . POLY VAPOR HRIER LEGIS !ty .�r.., 54'-0' roret w. mor Toa n Nr.r. 4eamm erw0 vee 0.0 num a7Val. mut 000 270t(00! 710.0. 0 V 796 P.X.rea f1ATP.. P£S.RIP_i0R dA w ▪ p, G 15 - ACC%PI`ANCE tis PROW 0 - ACCEP1'iYCE C=tri? A5 NOT YM, OPACLIET 2000 RICIIty OF 007010 m.wx ev VS Cni .120770! Tula !Gars- ATCO SiWUCTJRFS IU95 1000 1106 MORT% TEMPLE OR/VE DORO L 7SYA5 75041 2400 avm®V6Nerr ROAD 7701.1'A FAGS. cs7A5 1070e SP£CfflCAT0Uli N'LOAFiC0 606-C25 .St.8 ooFb��ici3 L IEF.:r !, koilet CA030 SECrON E aR'1mFPAM IDR1VIK 00 [ .3,mr.Y-p' rtne7r 56111, l'047 g4w0a. 11x2 FRAME Francs: Astec: NIiCh: Tires: 12" 26f, 3 -RUNNER SKID PRAYS Ti„, 18' & 50" EXTENSIONS, BUMPERS TD MATEif2NE WALLS - - - LO O' S — Ploor Joist- insulation: Subfl000 Undersheetiltng: Floor Oaccringe 22191 CO" O.C.. DOUBLE RIM JOIST. EXTRA JOEST TO RANCE AREA 12-19 KRAFT -FACED 3/4" T&G PLYWOOD 30-GAUGR METAL BELLY PAN N/ 2/8' 058 UNDER EPDXY FLOOR TO KITCHEN & WASHCAR UNITS, tie- vLNYL COYp0SITE TILE TO REMAINDER '1s' WALL Yell Erasing: tnoulation- Ext_ Sheathing: Top Plats: Bottom Plate: Interior Covering: FRP: Vapor Barriei, Esse: Est Siding: 224 6 l$^ O.C. MATEIINE VALS. 2213 615" 0.C. TO OUTSIDE WAILS R -U UN -FACED TO MATEUNE FIAI.i.4. R-10 UN --FACET) TO OUTSIDE YiALLC 7/2" CD2 DOUBLE SINGLE 5/8" WNYL coma) GYPSUM FULL HEIGHT FRP OVER 5/8" GYPSUM ETICNEN/SOSTROOti 8 MIL POLY VAPOR BARRIER TO EXTERIOR WALLS Ac i4ATELINE WALLS 4" VINYL COVE BASE 28 CA. PAINTED LOW RIR SIDING W/TRIM INTERroR WALLS Wall Framing: Insulation: Top Plotc: Rothim Piste: Interior: FRP: A"nr. 2X4 j2 SYP 0 Ed" O.C. 10-11 UN -FACED INSULATION TO PAR17'TIONS DOUBLE SINGLE 5/5' VINYL COVERED GYPSUM FUEL HEIGHT PRP OVER 5/8" CYP 0TeCHEN/RESTROOA( t' MATY/ rnvo RARP Plenum Wail: 2X4 WOOD PLENUM WAI,£, Roof Fronting. 2221 (2 SW ® 18" O.O. Insulation: R-30 UN -FACED CAVITY FV.TP5 Transvarse Slope: 2x0 • 18' O.C. TRANSVERSE SLOPE Ceiling: 224 T -GRID SUBPE'NSED CEILING Roof Skinning: .045 £PDM W/ TERMINATION STRIP TO PERIMETER Root Sheathing: 1/2" 002 PLYWOOD Root Flniah: 5/8" TYPE X• GYPSUM TO UNDERSIDE OF RAFTILCi..t�� AR vapor Barrier: a -Mf . POLY VAPOR HRIER LEGIS !ty .�r.., 54'-0' roret w. mor Toa n Nr.r. 4eamm erw0 vee 0.0 num a7Val. mut 000 270t(00! 710.0. 0 V 796 P.X.rea f1ATP.. P£S.RIP_i0R dA w ▪ p, G 15 - ACC%PI`ANCE tis PROW 0 - ACCEP1'iYCE C=tri? A5 NOT YM, OPACLIET 2000 RICIIty OF 007010 m.wx ev VS Cni .120770! Tula !Gars- ATCO SiWUCTJRFS IU95 1000 1106 MORT% TEMPLE OR/VE DORO L 7SYA5 75041 2400 avm®V6Nerr ROAD 7701.1'A FAGS. cs7A5 1070e SP£CfflCAT0Uli N'LOAFiC0 606-C25 .St.8 ooFb��ici3 L IEF.:r !, koilet CA030 SECrON E aR'1mFPAM IDR1VIK 00 [ .3,mr.Y-p' rtne7r 56111, l'047 g4w0a. 11x2 LP s5 iewf iL� 1.46i �"x=J+Cti' �A7 SRM 75- LPI 7 •+1.5kW FFH(TYP QF 4) i 1: 1P1-� N 61'2-5 UNI103 LP3-5 3. ; LP3-$ pSe i9BG�.. 3 ash' 3.0 TON.15kW MVAC UNIT 1.3 2#4+S#6 GNI LT ; E,EX 3.0 TCN, I SkW HVAC UNIT 1.3 2#4+1#5 CN© FLEX ;.0 T01 .15kw HVAC UNIT 1,3 —2N4+1#6 CND d ' C • Er.h Les111,9: 55K CO, u ael.I 10.. n> rnlr (OR a.a l:ro. • .24• btr KSbtC sw n,9rt RCH(w OrTE: —1 0u$Tc111,1El ACC.FPTANCF x:to sraucusaes (AA? Inc. 0 - .(;CCPUKf ono. p - ACCEPANc f%LEFT NrEtlI..µy 1?IOS RS�EgCOPAiICHT 20.30-0 011El0.L. 10,1,5 75341I05 gHflf[MlC O n4 :011;1 rlJ P0Sl 1 0CL ECdasn-. O 1 �,ra O IEL CA'' :PCC1f1G11Ow NVVarf UM15r :art St-tzer r.»�[S4'.71 .n..r..c �a. 9364-01—g. ATCO STRUCTURES DIBOLL, TX SUBJECT: Ground Anchor Tiedown Design THE LOAD CONDITIONS FOR THE FOOTING DESIGN AND TIEDOWN SYSTEM ARE BASED ON A VARIOUS WIND SPEEDS THE BUILDING CODE REFERENCE IS 2003 INTERNATIONAL BUILDING CODE. 90 mph, Exp. C STD. WIND PRESS = 10285 PSF - MORE THAN 3' FROM CORNER END ZONE PRESS = 15.488 PSF - WITHIN 3' OF CORNER AVE. WIND PRESSURE BASED ON 48 FT LENGTH OF BUILDING • LEAST LENGTH IS WORST CASE AVE, WIND PRESSURE = 10.94 PSF FRICTIONAL RESISTANCE FACTOR = 0.32 ASSUMED THE ASSUMED MAXIMUM UNIT WIDTH IS 13' 4" WIDE HORIZONTAL WIND LOAD SEE BELOW FOR ACTUAL WIND LOAD VS.- WIND SPEED THIS CALCULATION IS FOR DEVELOPMENT OF THE GROUND ANCHORING TIE DOWN SYSTEM FORA MANUFACTURED MODULAR STRUCTURE. WIND LOAD IS BASED ON THE CONDITION OF A MAX. 12.5' BUILDING HT. OFF THE GROUND DEAD LOAD = FLAT PITCHED ROOF 13.33 FT DESIGN OF TIEDOWN STRAPS & WALLIROOFIFLOOR PROJECTION - • 55 PSF EFFECTIVE ROOF AND WALL PROJECTION = 12.5 FT DEAD LOAD FRICTIONAL RESISTANCE = DEAD LOAD x FRICTIION FACTOR x UNIT WIDTH x0.6 WIND SPEED MAXIMUM SPACING OF STRAP TIEDOWN - HORIZONTAL LATERAL LOAD WIND LOAD APPLIED TO FLOOR RIM 90 MPH, EXP. C VERTICAL TIEDOWN - 90 MPH, EXP. C FRICTIONAL RESISTANCE 10.94 PSF 136.69 PLF 140.7648 PLF SINCE THE FRICTIONAL RESISTANCE EXCEEDS THE APPLIED LATERAL LOAD; NOT ADDITIONAL TIEDOWN REQUIRED FOR SLIDING RESISTANCE STRAP SPACING OF WINO UPLIFT = 12.5 PSF WIND UPLIFT REACTION (after subtracting dl) = -136.63 PLF 24 FT O.C. - ACTUAL TENSION LOAD ON STRAP = -3279.18 LB (NONE REQUIRED FOR DIRECT APPLIED WIND OVERTURNING MOMENT DEAD LO! W COUNTER CLOCKWISE RESISTING FORCE •-- CLOCKWISE 854.33 FT -LBS ! FT. OF LENGTH THE DEAD LOAD ON THIS SIDE TO ADD TO THE WIND OVERTURNIN CLOCKWISE u 33.98 IN APPLIED DEAD LOAD RESISTING MOMENT = ENGR: KEVIN M. FINN, P.E. 2700 W. WILDEN AVE., STE 4 GOSHEN, IN 46528 UPLIFT LOpO REGis'Av 33.98 IN �C�iAt4`i 1063.43 FT -LBS - THIS ACCOUNTS FOR DEAD LOAD OVERTURI�If THEREFORE THE DEAD LOAD RESISTING MOMENT EXCEEDS THE WIND OVERTURNING MOMENT NIA fS ThE'PROPEPI'Y OF TEE THIS INSIGNIA IS THE PROPERTY OF THE STATE OF COLORADO DIVISION OF HOUSING THIS NONRESIDENTIAL STRUCTURE COMPLIES WITH THE FACTORY BUILT NONRESIDENTIAL CONSTRUCTION STANDARDS OF THE STATE OF COLORADO MRi4UFACTISRERiS1' NAME PLAN APPROVAL "IT ID* 1111111111111 DATE BUILT 11101111111111111. CERTIFICATION NO. FBNR MANUFACTURER CERTIFIES THE FOLLOWING: 1111.111111111.11 PSF IMESIIIMI MPH 1.1111MINI PSF ROOF DESIGN LOAD MIND SPEED moon DESSGN Li)4L1 FIRE RATING E KTERIOR WALLS HA FIRE RATING FLOOR FARE RATING CEILING ®1111111111111.111 H R �® HR MECHANICAL ELECTRICAL .1111111111 PLIIMBftQ HAZARDOUS VOLTAGE, WILL CA SEVERE INJURY OR DEATH_ urn OFF PDwar S%DPlyin0 thfr u4 ui Drnarst Du ire TENSION p wma DES SLESSURES GRAVES OU LA MORET COUPar I•aumama;lon utoatnQae Ov cet b4urpenrent a"r4 cry egee-how aoa Solvently - 1 a ntla. SEVERAS E PELIGROSO. OAVSA •HERIiDAS 11.47 'LFA ;mr-a a MUERTE. roo noepn e...e al^+w.^a . Ira II, at G-.: