HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-5-15-3649 Aspen Signature Homes, LLC Lot 257 Ironbridge PUD 203 River Vista GWS, Colorado 1) SEE PLAN ATTACHMENTS FOR BUILDING REQUIREMENTS. 2) ALL WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) AND THE MANUFACTURERS INSTALLATION SPECIFICATIONS. 3) GEOTECHNICAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF COMPACTED STRUCTURAL FILL; 1500 PSF. PROVIDE ENGINEER SEALED APPROVAL REPORT AT UNDERGROUND PLUMBING INSPECTION. 4) STRUCTURAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF REINFORCEMENT BARS, HOLD-DOWNS, AND TENDON INSTALLATION. PROVIDE ENGINEER SEALED APPROVAL REPORT AT UNDERGROUND PLUMBING INSPECTION. 5) STRUCTURAL ENGINEER SHALL FIELD VERIFY MEASURING OF POST TENSIONED SLAB CONSTRUCTION. PROVIDE ENGINEER SEALED TENSIONING APPROVAL REPORT PRIOR TO FRAMING INSPECTION. 6) ONE (1) HOUR FIRE-RESISTANT CONSTRUCTION REQUIRED TO UNDERSIDE OF WATERPROOF DECK PROJECTION PER 2009 IRC, TABLE R 302.1. 7) MINIMUM 8" X 8" WOOD POST REQUIRED AT WATERPROOF DECK, AS SPECIFIED PER 2009 IBC, 202.4.1, HEAVY TIMBER, OR PROVIDE ONE (1) HOUR FIRE-RESISTANT CONSTRUCTION. (CONSIDERED THE SAME AS A WALL SUPPORTING FLOOR LOAD) 8) ENGINEERED FLOOR TRUSS SHOP DRAWINGS REQUIRED AT FRAME INSPECTION, 40 PSF. 9) ENGINEERED ROOF TRUSS SHOP DRAWINGS REQUIRED AT FRAME INSPECTION, 40 PSF. 10) ELECTRICAL ROUGH -IN APPROVAL 15 REQUIRED FOR FRAMING INSPECTION. 11) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION.