Loading...
HomeMy WebLinkAboutApplication- Permit4. Garfield County Building & Sanitation Department 108 8th Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO. cis -33 Job Address 0388 4d rb 7 / ,(, V Js Nature of Work Building Permit i %rnjoran C . r Iir'I :Mr ,,at _i Use of Building Owners Contractor t. gala Amount of Permit $ 411)t_90) , t qc s.$)— Date Clerk 31310`ailAkizAk,‘LQA SetiA.4 FAA/LAI, Permit No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8^ Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-8212 / Fax: 970-384-3470 Inspection Line: 970-384-5003 R�33 Parcel/Schedule No: /2/S 5 374/600q AGREEMENT PERMISSION 15 HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 3028.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEIN CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OVWER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. irfora.008 I HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 1 V"J Job Address• 0383 RtibcceA C,"Cct otZNwOcD Viem-6 Cc 8 160 / 1 Lot No: qBlock No: Subd. / EYemption: 'TOUR MILL RA -1G1-1 2 Owner: 'h' WTD So j -4 Address 8 1 1 PALM EQ 11 VE frtyv 6-1,0s44000 90:',,i,ra Ph: 970,309 0,/a Wk Ph: 970 118 r3S 3 Contractor: /t -s A&oJk-. Address: Ph: Lic. 4 Arehitect/Engineer: PARR`' (OLE Address: Ph:y70 sy 60277Lic. No. 5 Sq. Ft. of Building: 3o00 Sq. Ft. f LI: _ / `Seight: %� /3 ,45� •�/1 i IY i% ^� No. of Floors: / 1- CAA •ria,S MLN sLI dt 6 Use of Building: U.(A L✓! 7 Describe Work: ti (On) frT luC; jpi OF tie vJ R£ gii3EAClimadets - 8 Class of Work: SCC New ❑ Alteration o Remove ❑ Addition N Move 9 10 Garage: o Single gc Double Carport: o Single o Double ❑ Driveway Permit,❑ On -Site Sewage Disposal K Site Plan 4 (Septic) m1,4 ��j,�% jt �v" 11 Valuation of Work: $01501 000.00 ,#`� y'�/��Ij� L 'g ,,��// A'r> 1 •�?! $�'l f• �, ���lll�j "�/ J 12 4$patt l CondltWes: --yjJI� To ` ,/ ittia (D 3- 31.O(o -t- in V 24044.2- - �d� p ( l(ia.1r) NOTICE A 4PARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OFCOLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF es NSTRUC ON. 0 'Cr. J 9.4 7OS Plan Check Fee: i's5 Z In .31) Permit Fee: 2.25 -10o9.71 - T I Fee: Dated Permit Issued: / 1 o4.i 41744 OC Group: Const. Type: —�1� R5 Zoning: Setbacks: Manu. Home: ISDS No. &l Fee:w'a Teirnefea ,kiri 7 0.OS 4121 cif 041-C6�"`& LDGD P •G. DEPT. ' APPRO . 'ATE A'PROVAL/DATE AGREEMENT PERMISSION 15 HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 3028.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEIN CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OVWER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. irfora.008 I HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 1 V"J The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road;,,, 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. 1 understand and agree to abide by the above conditions for occupancy,Ase and the issuance of a Certificate of Occupancy for the dwelling under building permit # !`S3 �. AatAkrP 722 05 - Signature Date Bpcont03/2004 k VALUATION/FEE DETERMINATION Applicant s Subdivision T kt e..4C J/!7I le Ka,,, Address Yit3 rrthiFF auk ack Lot/Block 9 Date o. / a me Contractor F n z -rt Finished (Livable Area): Main ? j' &S„ Upper Lower Other Total Square Feet st(4 v 7) Valuation Basement: Unfinished zSbe. 411 Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation (73 110 4 lg Valuation Decks/Patios: Covered Valuation Open Valuation Z15,6Zep 4e HS 34, 7o,) •c 24 4 $9(i 7�jYiL Jsog Total Valuation 342044 d3 P VALUATION/FEE DETERMINATION Applicant iQ /LA Subdivision /tll f&Ar pV7],ie yfcc 4 Address ' Q Fr Once Lot/Block 7 Date Co a Contractor Finished (Livable Area): Main z • P Upper Lower Other Zig y 74S = 2r5m574242. Total Square Feet , d '..) Valuation Basement: Unfinished a SS 4' )) 11S 3:.‘ Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation 73 d;io 4 ip = Valuation Decks/Patios: Covered Valuation Open Valuation i`frG S8 2o� 24) 4894 Total Valuation VS 02, 1 'BC. f i?» 4o x•57 4 J' Aiktritookair 431, 052 4% gspg i' fill 74) Sip-) Friz 4Weil O . 31aIhb l GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design ProfessionaL To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and 1 drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is sho on the final plat with the proposed structure located within the envelope. Yes rY 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do Iy. Yes /I 3. Does the site plan include when applicable the location of the I. S.D. S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes_ 2 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing l in accordance with the IRC or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces anthe clearances required between wood and earth? Yes Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ✓ 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes Does the plan include a building section drawing indicating foundation, wall, floor, and roof construct"? Yes ✓ 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes ✓ 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (undisturbed) grade contours? Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model d Colorado Phase II certifications or phase II EPA certification? Yes ni it- No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with th IRC? Yes 4 No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping ro and/or basements comply with the requirements of the IRC? Yes r No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventila ''°n for all habitable rooms? Yes V No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safetyg for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes Z No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted wi t it. Yes No 21. Will this be to4nly residential structure on the parcel? Yes No If no -Explain: 22. Have two yrnplete sets of construction drawings been submitted with the application? Yes t 23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? Yes No 4 l • 24. Have you designed or had this plan designed while considering building and other construction a requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone ct? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the eld County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the application o ese changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in 384-5003. Yes_ No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $47. e -inspection fee? Yes C No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of ding? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for ap-Agent and that the party responsible for the project must comply with the IRC? Yes No 5 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at g25-8601. Yes /1 / fJ No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of appli a inspection. Yes i / No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit ap tion? Your attention in this is appreciated. Yes No 36. Do you know that the local fire strict may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this requirement) I hereby acknowledge that I have read, understand and answered these questions to the best o(my ability. ignature of Owner <42 770 Dat Phone: 97O - 2O -U7/ Z (days); 47 70 - 3C.)6 O Z i Z. (evenings) Project Name: b. -ALS ,Qt-fi QE,,i C, f Project Address: 3 el r L, A6 1 4 l Vii & �',6 l , (0 k>/Lc Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminregOct2004 6 PLAN REVIEW CHECKLIST Applicant B s Date 6, 2 3• O5 - Building ✓ Engineered Foundation /14. Driveway Permit Surveyed Site Plan 3. E. e{a,)s,l j/4 Septic Permit and Setbacks -.Grade/Topography 30% ✓Attach Residential Plan Review List L. Minimum Application Questionnaire _ubdivision Plat Notes Al/Fire Department Review Valuation Determination/Fees wed Line Plans/Stamps/Sticker Attach Conditions lication Signed --iPllaan Reviewer To Sign Application ✓Parcel/Schedule No. 40# Snowload Letter- Marti Hms. Plagning/Zoning a//Prroperty Line Setbacks &30ft Stream Setbacks AT 4. Flood Plain uildin Height ing Sign -off Road Impact Fees �HOA/DRC Approval `'-/ Grade/Topography 40% //-- di Issues Subdivision Plat Notes Aar 11 05 03:21p fax transmittal Dale. March 11.2005 Time: 2:14 PM To: David Bowers Fax, 970 945-9619 Company: Phone: 970 928-2135 Project Name: Lot 9 Four Mile Ranch Regarding. Preliminary/Final DRC Approval Number of Pages: 3 Project Job k. Comments: PBA Letter, 04140 Lot 9 L3, 3/11/05 ..enclosed. p.1 palominobartharchitcu, PC' David, As discussed, approval for Preliminary and Final Design Review approval enclosed for your files. Best Regards, Jack Palomino pl.nr•nl r. -- - nyHarrl 39S7=14R2-Fax - Jeff Vogel 303 892-4984 Fax Michelle Hagemann 970 963-2298 Fax Mogli Fairbanks 970 947-9335 Fax Enclosure: 815 bit avenue glenwooe springs colorxlo 81601 p 970 945 6655 r 970 945 6585 ww, plum; nobaih mm 9 Mar 11 05 03:21p 1 -- Please note that Guy Harrell will review the expense of relocating the existing Qwest telephone pedestal for easier driveway access for Lot 8. We agree that access to Lot 8 is not your responsibility, although construction sequencing may be easier if relocation of that utility is accomplished prior to completion of your final driveway paving and landscaping. If you have any questions or comments regarding these approvals, I can be reached at 970 945-6655. Thanks again for your participation. Sincerely, Jack Palomino AIA, Principal Palomino Barth Architects P.C. On behalf of the Four Mile Ranch Design Review Committee JP/jp 04-140 Lot 9 L3 cc: DRC Members p.3 815 Blake atenue glen wood spnngs. colorndo 81601 2 p 970 995 665 (9709456685 www palommohunn.com DRAINAGE STUDY Lot 9: 4 -Mile Ranch GLENWOOD SPRINGS, COLORADO PROJECT NO. Bowers Prepared by: BOUNDARIES UNLIMITED INC. Consulting & CIvII Engineers 923 COOPER AVENUE, STE. 102 GLENWOOD SPRINGS, CO 81 601 TELE: 970.945.5252 / FAX: 970.384.2 Deric J. Walter, P.E. Project Engineer TABLE OF CONTENTS SECTION PAGE INTRODUCTION 1 HYDROLOGY 1 DRAINAGE PLAN 1 SUMMARY 1 FIGURES: 1) Vicinity Map (8'/2' x 11") 2) SCS Soils Map (8'/2' x 11") 3) Drainage Plan (11"x17") 4) Misc. Notes and Details (11"x17") APPENDIX: Calculations INTRODUCTION The proposed residential development of the Lot 9: 4 -Mile Ranch property is located off Red Cliff Circle in the 4 -Mile Ranch Subdivision, Garfield County, Colorado. The 2.45 acre property is presently vacant. The proposed development will consist of a single- family residential structure, an access drive, landscaping and undisturbed grasses. See the enclosed Vicinity Map for site location. HYDROLOGY The hydrologic methods for this study are outlined in the United State Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) publication "Urban Hydrology for Small Watersheds TR -55" and the computer program AutoCAD Hydrology SCS TR -55 Tabular Method. The property is located well above the Roaring Fork River and 4 -Mile Creek floodplains. Site soils consist of Type B soils with a historic vegetative cover of pasture grasses in fair condition. No major offsite basins affect the property. See the enclosed NRCS Soils Map for hydrologic determinations. DRAINAGE PLAN The stormwater runoff from the lot will be, in general, unconcentrated sheet flow and shallow channel flow. The existing general flow patterns will be maintained with runoff tending to the northwest. Due to the rural nature of the subdivision and regionalized detention in the lower valley, no individual detention should be necessary to offset the impacts of development for this lot. An 8" deep diversion ditch or berm, with 2:1 side slopes, should be construction parallel to the boundary between Lots 8 & 9 to ensure that runoff is diverted away and around from all downhill building sites. Erosion logs or certified weed free hay bales should be placed in the flowline every 100 LF and maintained until the site is fully revegetated. Swales should also be constructed on the uphill side of the residence to ensure that offsite runoff is diverted away from and around the proposed structure. Page 1 Figures Page 2 Boundaries Unlimited, Inc. 923 Cooper Avenue, Ste. 102 Glenwood Springs, CO 81601 tele- 970 945 5252 fax- 970 384 2833 SCALE: 1"=2000 DATE: 3/12/05 FILE: GR -01 SHEET. 1 David Bowers Garfield County, Colorado Lot 9: 4 -Mile Ranch Vicinity Map ,� . t'�''__ �r _ t_ � I .) ! e ( 7 , \ • d'F 2 .% I' ti.� w \ ..._.., iii SITE f7s; I i 1 ' . At;ti 1 �� ' .2', _ . 'x C. v' i .I., ., do.,,. Boundaries Unlimited, Inc. 923 Cooper Avenue, Ste. 102 Glenwood Springs, CO 81601 tele- 970 945 5252 fax- 970 384 2833 SCALE: 1"=2000 DATE: 3/12/05 FILE: GR -01 SHEET. 1 David Bowers Garfield County, Colorado Lot 9: 4 -Mile Ranch Vicinity Map 19 f : 1 \ J // SI ;5 •\ j 5 \ I j j :rrrti.- 7I/( a I ` 'r0\ — K/% t z < R 9 t l 13 >. i— \\/ 33 � 34 2 ����/ ror.„ LU4IT or s01L so"ver (6-12% slopes, SOIL TYPE Soil Type B) 6: Ascalon Fine Sand Loam deep, well drained, mod. permeability: - Boundaries Unlimited, Inc. SCALE: 1"=2000 DATE: 3/12/05 FILE: GR-01 SHEET: 2 David Bowers Garfield County, Colorado Lot 9: 4-Mile Ranch NCRS Soils Map 923 Cooper Avenue, Ste. 102 Glenwood Springs, C081601 tele: 970.945.5252 fax: 970.384.2833 w D -n D 0 0 N 0 c f O z T m¢ o v K Z OM il r Z moD-1mm O A D O C O�z{oCz� m * r C ±00>21 mA A N 0ce�r ro i m ri z0 vim r mo ons r m O\ mrozvn I 1 m0o0zz ru Li AcnZm›in •{OI in in cA O' A c 20 c C O A O f� „mCy0 CO,OA n' A �X/ ZOo r mC m A rn /A y z)r Gm j0 m{rAr� rn mm�2 zr _ir m O m 0 ti › N N N A O_ zz InODN m (nor z>G7 c 0 In = O_C,)-1 CO tins Ort:m A fD FupZ D m rsFrg9ct . ehlr Garfield County, Colorado Lot 9:4 -Mlle Ranch Grading and Drainage Plan w/ Erosion Control David Bowers 819 Palmer Avenue Glenwood Springs. CO 928-9558 Consulting & C,44 En®"..n ui Cooper Gwnue.su 10 Glenwood Sohn 008160 161e 970 945.5252 fax 9703842133 Z O -i 0 0 t!1 m m > 0 z �O z D> —r —r zoo 4z .._ z 2 m O cn D i —0 EnY 7 Z Z 0 S0 r Oma\\� A z FPri Z n n D D 0 O O 0 0 0 N z 0 N m D mo n N N Z A 0 N 5 firm m0>0CnDmla r m O m Z A m Z n m O O n mrpmA m 4CmZ Z AADInnAZ oZMM TI -c PDO m'N Cn!F O m m A O m m m r m A �r cy Dn coN a WC > p no u1 > s 0 m o o N F p N N N O n O A A O Z M 0 0 ODm s 2A➢ as aCO se Z s T >m Noon-Ssm A Z-4VKD AO ::::: 0n<maON Or In 0m2Dnm N a 4 Nfr2pr ND a D'ID0. o y m �__ ZD >MO ZKZAON ZmD�DmAAYTO~�.A� . Dm mNm FIAnmCSy� �m r_z 0CDF�OOmmmmm0DD=1 z 02mjN II m>!OZZarX0ZK :D Oa ZC Cm0°m o 2 min IA 0mOOm� ZZz:QOQ to .ozal $' mmz'^MO'jzCoo� ODa tiaDNC�ONAAoO-+ mr O_O `3 op�A D�DOO KZ Inay OM KnZmO Fap_OcO~ralSm C_mti� ONSOCOKAZKDD fZmmMW 22 N SAODnat �� Ilii:_ O 2 m p rr�5 O A O N 1 o ti n p N D A D O a t ?I O a O r>- n Z O N p p 0 Z N m m ti A 2 A O m D5 -_-,97,M Inn = m m oo r 2 y > A A O> Z O n A>Fm>m °-nm>mm V. NQz ODa OC DNn�llm n A�Iaj m n�nCO PvoODmm Cm22Fm0 oNZ .r;IK/I moLAO m=o�m��mKmy> slDjl aZ1zn Inti-ZNn NaOr mC ;41,c N'I .11 y rm yaym mot- Immmy <D< rO m.TOIi rw mapnp Omnc r'amN SAO-0�0 OFDAO C0�fn0 o 0�0>< m��mO Mc KD °lemon N _mono °Naze° >mFI' xS oinz2 iK/I�OpZpm m vO:mn. zn nzm i c `` N COZT re mDOAO L)�mOOm .I^�A 0S000P 2Oa0mn� DmmZ T; ZZ A(Ci� Daazn Dr�D� m A�m� �0� 0 r�zNNos D �rCCmoony, >nmzAc an ~r Oz ZO oFzm D n O m z o n o 0 N m O m O F m N. m m: a o m< D O m O Z= Mr" _ Z Iyr m m >mZ In Amcmmgy OOZa rymti�r <A UIn D-IM� 2 Ky90LZl n2 DaOA I^o runt CX Z0 aN92 >>0710AKD rn ~OLmmmm D o".Zm1 ,mAo OT CD<on p m n D Z C m x m; p D o r 9 D N >a .1J rnn m K 2- D 0 o Z 2°; M ti m N N Z m 0>Z0Z 2 9mmFNm AOnm TO -•TOO yDN�9Zy . ton -Oz zD n+TiyDz Nr Nsr- rn O 0n�2 a3ool'Im ay ODN -1 mn-^ti >m2C0Z ONm n~m�a OmNm patiN <0 Ar`1mn y2 Om > A m zz< N 2 42 n r n o 9 le n fn y G Dp y N r A m n D w m 2 Z a ynm Z m z a m D? D $ m N O a O- O- " N- Z m O K O N>000 OTZDIn IDK iO2Ym D yl+lm DmAx ZO r gran 0 A T O 00 Z O D z CD > a m O Z Z 0 ryD`D 0 A m N 000 at,, Z O Om A n m 0:x0 FZ�OrMZ!O CM 00 0Ap Ammpyy1 mmZN Ir Z rN ;ir;;;;14 ntn DrMMN yFDA7� Wm np mVI>A�nx apZr DNpN S> Zr co >cmt r m 0 r� O D m on p y n O Z* m C Z ti r i Z N N r O r InOOA Nxfnn 0> W92;37.2-2 09�a °a�CC nAO1�x r~I a 2> AOrm Z oz n D Z O m D Z Z Z> O r C p Z m Z p y N n n y cc y 00-,2 ;AN �S> 22 mm Or (>' XrIADmo mmx �AN!n Nma DC Wid ley CaDmo 9yln~`Z za n z � n D cy n z Nmr 0��0 2`9:0~0 -Mm O� on NNyO VIIAAm NInL O'� A2 VOZyC�O ynAA 1/IarN. yA Z Amm-.x;pA °250 2m. O N 2mtiinS�KD ZZr'ID 5>oro O� rD K m�mN S�rnni 000 mZ k� ONmrO�x "Mnma2 2 n- on 0 <y tit n ms -30 n-. A N TA20. Z m 2 0 C y A D L O m D m Z D m m C O D C O 0 9 ^� O p m m y pZ n £ >0 rmrlm> ii; 11/02 ?? jD Voy�yOO9xD jm2S n dm ZD mKm2l>/1 m l/I ZC ,,Or A AA mDKrymD OZCC �N mD Nn mn �D0�2>CA rA-rl0 c of 4-o1r>ysi mm�o X' �a., az o » Ago<�Z Dzo VIN. oomOappOKN P1 o�s rinmao�; D+oi0C�Z ZrZC-0mDr.lZO D�'2ZDCmO ZS OGmtiZ11120 ZZO .Z TDAONKDIn> K °D A41 00NOOyr5.2nm rn T:::: m OmZrzA 2 AO rr'y yDr.AOrm0D000 Ain mc Ar y.Zol ZN �yT OSmC NmTm � £ (19, f�19C oZ .y�aln 2 F2. IA An A� 0s m 2 Z_a O>0 Tzm n0-oo/lo s yy yA Vill mlmilDsoo C00+mjIZ/10 nD Dmim=aT9JDV'x yP0 MOWyAN.imc o .ZIC pmz Jo ys2nSFm 00DOlmnnlna0G�ZKy`50-r 1NDnlm/I?OAFD:<O 9mym-oAZOnmZnCOON OmZDZmxAin o m- �l;nACAADtD'IN22ozo D mm>yz00o InD mm CS zoDtixocZpvZma N~Oym 0 r NT D C i' 0 NOmZ D NAA D p0OSZ rZO Oin, non or' p D no ym;D, O NaiN y KO Z Z !nm no ~ > < 2 O Z .9 Z N 0 O Z O x A 0 0 • fl -1 Z Garfield County. Colorado Lot 9: 4 -Mile Ranch Misc. Notes and Details David Bowers 619 Palmer Avenue Glenwood Springs, CO 928-9558 rarses •nlimited Inc conwin[ S Oxl 5.perm 923 0xper GA,V. 51e 10 Glenwood epn p CO 5150 leis 9909.55252 far 9703992 DES DJw NO DATE REVISION DR OM CN. PAH DATE. a/12/05 BY Appendix Drainage Study Calculations Input into AutoCAD Hydrology TR -55 Tabular Method Project: Lot 9:4 -Mile Ranch Project No: Bowers By: DJW Date: March 12, 2005 Area: Basin: 22124 sf.± (Topographed area) Precipitation, 24 hr: 25 -yr: 2.0" 100 -yr: 2.4" Time of Concentration, Tc Existing: Sheet= 170'@ 7%, Shallow= N/A Tc= 0.23 hr Developed: Sheet= 90'@ 8%, Shallow= 150'@ 3% Tc= 0.20 hr Soil Type: Basi n=Type B: 6: Ascalon Fine Sand Loam (6-12% slopes, deep, well drained, mod. Perm.: Soil Type B) Curve Number, CN Existing=69 Pasture, fair condition Developed=79 33% Imperv. (98) 67! Revegetated landscaping/grasses (69) Existing Runoff, QH Lot 4: QH,A25= 0.08 cfs Developed Runoff, Chi Lot 4: QE,A 25= 0.30 cfs QH,A1oo= 0.23 cfs QE,A 100= 0.45 cfs Due to the rural nature of the property, no detention is proposed, but an 8" deep diversion ditch or 12" high berm with 2:1 side slopes should be constructed parallel to the property line of Lots 8&9 to maintain runoff away from and around downstream building envelopes. Ex-Q25.txt Bowers Property Lot 9: 4 -Mile Ranch Existing Conditions 25 -yr Runoff 3/12/05 TR -55 Tabular Hydrograph Method Input Summary Description Existing Conditions: 25 -yr Runoff Rainfall Distribution Type II Ia/P Interpolation On Total Area 22142.00 ft2 Peak Time 12.20 hrs Peak Flow 0.08 cfs Given Input Data: Subarea Description Area CN Tc Tt Rainfall (ft2) (hrs) (hrs) (in) Topographed Area 22142 69 0.23 0.00 2.00 Support Data: Subarea Name: Topographed Area, Row: 1 Sheet Flow Description Manning's n 0.15 Flow Length 170.00 ft Two Yr, 24 hr Rainfall 1.40 in Land slope 0.07 ft/ft Computed sheet flow time > 0.23 hrs *************************** Total Time of Concentration > 0.23 hrs Page 1 EX-Q100.tXt Bowers Property Lot 9: 4 -Mile Ranch Existing Conditions 100 -yr Runoff 3/12/05 TR -55 Tabular Hydrograph Method Input Summary Description Existing Conditions: 100 -yr Runoff Rainfall Distribution Type II Ia/P Interpolation On Total Area 22142.00 ft2 Peak Time 12.20 hrs Peak Flow 0.17 cfs Given input Data: Subarea Description Area CN TC Tt Rainfall (ft2) (hrs) (hrs) (in) Topographed Area 22142 69 0.23 0.00 2.40 support Data: Subarea Name: Topographed Area, Row: 1 Sheet Flow Description Manning's n 0.15 Flow Length 170.00 ft Two Yr, 24 hr Rainfall 1.40 in Land Slope 0.07 ft/ft Computed Sheet flow time > 0.23 hrs ac*arnfrxatae4*ant*e Total Time of Concentration > 0.23 hrs eeafr*eer eaapex*********** Page 1 PR-Q25.txt Bowers Property Lot 9: 4 -Mile Ranch Proposed Conditions 25 -yr Runoff 3/12/05 TR -55 Tabular Hydrograph Method Input Summary Description Proposed Conditions: 25 -yr Runoff Rainfall Distribution Type II Ia/P Interpolation On Total Area 22142.00 ft2 Peak Time 12.20 hrs Peak Flow 0.30 cfs Given Input Data: Subarea Area Description (ft2) CN TC (hrs) Tt Rainfall (hrs) (in) Topographed Area 22142 79 0.20 Support Data: Subarea Name: Topographed Area, Row: 1 Sheet Flow Description Manning's n Flow Length Two Yr, 24 hr Rainfall Land Slope Computed sheet flow time 0.00 2.00 0.24 90.00 ft 1.40 in 0.08 ft/ft > 0.19 hrs Shallow Concentrated Flow Description Surface Flow Length watercourse slope Velocity Computed Shallow flow time Unpaved 150.00 ft 0.03 ft/ft 2.79 fps > 0.01 hrs Total Time of Concentration > 0.20 hrs * ***************** Page 1 PR-Q100.txt Bowers Property Lot 9: 4 -Mile Ranch Proposed Conditions 100 -yr Runoff 3/12/05 TR -55 Tabular Hydrograph Method Input Summary Description Proposed Conditions: 100 -yr Runoff Rainfall Distribution Type II Ia/P Interpolation On Total Area 22142.00 ft2 Peak Time 12.20 hrs Peak Flow 0.45 cfs Given Input Data: Subarea Description Area CN (ft2) Tc Tt Rainfall (hrs) (hrs) (in) Topographed Area 22142 79 Support Data: Subarea Name: Topographed Area, Row: 1 Sheet Flow 0.20 0.00 2.40 Description Manning's n 0.24 Flow Length 90.00 ft Two Yr, 24 hr Rainfall 1.40 in Land slope 0.08 ft/ft Computed sheet flow time > 0.19 hrs Shallow Concentrated Flow Description surface Flow Length Watercourse slope Velocity Computed Shallow flow time Unpaved 150.00 ft 0.03 ft/ft 2.79 fps > 0.01 hrs aacaarar---rar*ceecr*ccr Total Time of Concentration > 0.20 hrs *a*strra*eeaerc*aa=ec*ecaxo-ae Page 1 Bowers Property Lot 9: 4 -Mile Ranch channel Flow 100 -yr Runoff 3/12/05 Channel.txt Channel Calculator Given Input Data: Shape Trapezoidal Solving for Depth of Flow Flowrate 0.45 cfs Slope 0.03 ft/ft Manning's n 0.04 Height 8.00 in Bottom width 0.00 in Left slope 0.50 ft/ft (V/H) Right slope 0.50 ft/ft (V/H) Computed Results: Depth 4.17 in velocity 1.86 fps Full Flowrate 2.55 cfs Flow area 0.24 ft2 Flow perimeter 18.66 in Hydraulic radius 1.87 in Top width 16.69 in Area 0.89 ft2 Perimeter 35.78 in Percent full 52.16 % Critical Information Critical depth 3.79 in Critical slope 0.05 ft/ft critical velocity 2.25 fps Critical area 0.20 ft2 Critical perimeter 16.95 in Critical hydraulic radius 1.70 in Critical top width 15.16 in Specific energy 0.40 ft Minimum energy 0.47 ft Froude number 0.79 Flow condition Subcritical Page 1 tech HEPWORTH -PAWLAK GEOTECHNICAL Hepworth-Pawlak Geotechnical Inc 5020 County Road 154 Glenwood Spnngs, Colorado 81601 Phone 970-945-7988 Fax 970-945-8454 email hpgeo®hpgeomch.com SUBSOIL STUDY , FOR FOUNDATION DESIGN PROPOSED RESIDENCE LOT 9, FOUR MILE RANCH RED CLIFF CIRCLE GARFIELD COUNTY, COLORADO JOB NO. 104 814 NOVEMBER 30, 2004 PREPARED FOR: DAVID BOWERS 1043 WEST 3RD STREET RIFLE, COLORADO 81650 Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY PROPOSED CONSTRUCTION SITE CONDITIONS SUBSIDENCE POTENTIAL FIELD EXPLORATION SUBSURFACE CONDITIONS FOUNDATION BEARING CONDITIONS DESIGN RECOMMENDATIONS - 4 - FOUNDATIONS -4- FOUNDATION AND RETAINING WALLS - 5 FLOOR SLABS -7- UNDERDRAIN SYSTEM - 7 - SURFACE DRAINAGE - 8 - LIMITATIONS FIGURE 1 - LOCATION OF EXPLORATORY BORINGS FIGURE 2 - LOGS OF EXPLORATORY BORINGS FIGURE 3 - LEGEND AND NOTES FIGURES 4 and 5 - SWELL-CONSOLIDATION TEST RESULTS TABLE 1- SUMMARY OF LABORATORY TEST RESULTS PURPOSE AND SCOPE OF STUDY This report presents the results of a subsoil study for a proposed residence to be located on Lot 9, Four Mile Ranch, Red Cliff Circle, Garfield County, Colorado. The project site is shown on Figure 1. The purpose of the study was to develop recommendations for the foundation design. The study was conducted in accordance with our agreement for geotechnical engineering services to David Bowers dated November 1, 2004. A field exploration program consisting of exploratory borings was conducted to obtain information on the subsurface conditions. Samples of the subsoils obtained during the field exploration were tested in the laboratory to determine their classification, compressibility or swell and other engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. This report summarizes the data obtained during this study and presents our conclusions, design recommendations and other geotechnical engineering considerations based on the proposed construction and the subsurface conditions encountered. PROPOSED CONSTRUCTION The proposed residence will be a single story structure over a walkout basement level. The attached garage and basement floors are proposed to be slab -on -grade. Grading for the structure is assumed to be relatively minor with cut depths between about 3 to 8 feet. We assume relatively light foundation loadings, typical of the proposed type of construction. If building loadings, location or grading plans change significantly from those described above, we should be notified to re-evaluate the recommendations contained in this report. Job No 104 814 - 9 - SITE CONDITIONS The site is located in previously irrigated pasture that was vacant at the time of our field exploration. The ground surface is relatively flat with a gentle to moderate slope down to the west. There is about 2 to 4 feet of elevation difference across the building envelope. Vegetation consists of grass and weeds. SUBSIDENCE POTENTIAL Bedrock of the Pennsylvanian age Eagle Valley Evaporite underlies the Four Mile Ranch subdivision. These rocks are a sequence of gypsiferous shale, fine-grained sandstone/siltstone and limestone with some massive beds of gypsum. There is a possibility that massive gypsum deposits associated with the Eagle Valley Evaporite underlie portions of the lot. Dissolution of the gypsum under certain conditions can cause sinkholes to develop and can produce areas of localized subsidence. Sinkholes were not observed on the subject lot or in the immediate area of the subject lot. No evidence of cavities was encountered in the subsurface materials; however, the exploratory borings were relatively shallow, for foundation design only. Based on our present knowledge of the subsurface conditions at the site, it cannot be said for certain that sinkholes will not develop. The risk of future ground subsidence on Lot 9 throughout the service life of the proposed residence, in our opinion, is low; however, the owner should be made aware of the potential for sinkhole development. If further investigation of possible cavities in the bedrock below the site is desired, we should be contacted. FIELD EXPLORATION The field exploration for the project was conducted on November 9, 2004. Two exploratory borings were drilled at the locations shown on Figure 1 to evaluate the subsurface conditions. The borings were advanced with 4 inch diameter continuous flight Job No. 104 814 -3 - augers powered by a truck -mounted CME -45B drill rig. The borings were logged by a representative of Hepworth-Pawlak Geotechnical, Inc. Samples of the subsoils were taken with a 2 inch 1.D. spoon sampler. The sampler was driven into the subsoils at various depths with blows from a 140 pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values are an indication of the relative density or consistency of the subsoils. Depths at which the samples were taken and the penetration resistance values are shown on the Logs of Exploratory Borings, Figure 2. The samples were retumed to our laboratory for review by the project engineer and testing. SUBSURFACE CONDITIONS Graphic logs of the subsurface conditions encountered at the site are shown on Figure 2. The subsoils consist of about 1/2 to 1 foot of topsoil overlying very stiff to hard, sandy silty clay to depths of 51/2 to 6 feet where relatively dense, basalt gravel, cobbles and boulders in a silty sand matrix was encountered. Drilling in the dense coarse granular soils with auger equipment was difficult due to the rock size and hardness and drilling refusal was encountered in the deposit. Laboratory testing performed on samples obtained from the borings included natural moisture content, density and finer than sand size gradation analyses. Results of swell - consolidation testing performed on relatively undisturbed drive samples of the clay and silty sand matrix soils, presented on Figures 4 and 5, indicate low compressibility under existing moisture conditions and light loading. The clay samples showed a low to moderately high expansion potential when wetted under a constant light surcharge with swelling pressures of about 4,500 psf and 8, 000 psf. The sample of the silty sand matrix from the coarse granular soils showed a minor collapse potential (settlement under constant load) when wetted and moderate compressibility upon increased loading after wetting. The laboratory testing is summarized in Table 1. Job No. 104 814 -4 - No free water was encountered in the borings at the time of drilling and the subsoils were slightly moist to moist. FOUNDATION BEARING CONDITIONS The subsoils encountered beneath the topsoil consist of about 41/2 to 51/2 feet of very stiff to hard clay that possess an expansion potential that could lift the building floor and foundation if wetted. Surface runoff, landscape irrigation and utility line leakage are possible sources of water which could cause wetting. The underlying coarse granular soils are relatively dense and have a low settlement potential. Subexcavation of the expansive clay and bearing on the underlying granular soils or replacement with compacted structural fill should be used to mitigate potential movement and building distress to the residence. DESIGN RECOMMENDATIONS FOUNDATIONS Considering the subsurface conditions encountered in the exploratory borings and the nature of the proposed construction, we recommend the building be founded with spread footings bearing on the natural granular soils beneath the clays or on compacted structural fill. The design and construction criteria presented below should be observed for a spread footing foundation system. 1) Footings placed on the undisturbed natural granular soils or structural fill should be designed for an allowable bearing pressure of 2,500 psf. Based on experience, we expect settlement of footings designed and constructed as discussed in this section will be about 1 inch or less. 2) The footings should have a minimum width of 16 inches for continuous walls and 2 feet for isolated pads. Job No 104514 -5- 3) Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 36 inches below exterior grade is typically used in this area. 4) Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should also be designed to resist lateral earth pressures as discussed in the "Foundation and Retaining Walls" section of this report. 5) The topsoil, clays and any loose or disturbed soils should be removed and the footing bearing level extended down to the relatively dense natural granular soils. Voids created by the removal of large rocks should be backfilled with compacted sand and gravel or with concrete. As an alternative, design bearing levels can be re-established with compacted structural fill. The fill should be a granular material, such as road base, compacted to at least 100% of standard Proctor density at a moisture content near optimum. The fill should extend laterally beyond the edges of the footings a distance at least equal to the depth of fill below the footings. 6) A representative of the geotechnical engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions. FOUNDATION AND RETAINING WALLS Foundation walls and retaining structures which are laterally supported and can be expected to undergo only a slight amount of deflection should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 50 pcf for backfill consisting of the on-site granular soils. Cantilevered retaining structures which are separate from the residence and can be expected to deflect sufficiently to mobilize the full active earth pressure condition should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 40 pcf for Job No 104814 -6 - backfill consisting of the on-site granular soils. Backfill should not contain vegetation, topsoil, clay soils or oversized rock. All foundation and retaining structures should be designed for appropriate hydrostatic and surcharge pressures such as adjacent footings, traffic, construction materials and equipment. The pressures recommended above assume drained conditions behind the walls and a horizontal backfill surface. The buildup of water behind a wall or an upward sloping backfill surface will increase the lateral pressure imposed on a foundation wall or retaining structure. An underdrain should be provided to prevent hydrostatic pressure buildup behind walls. Backfill should be placed in uniform lifts and compacted to at least 90% of the maximum standard Proctor density at a moisture content near optimum. Backfill in pavement and walkway areas should be compacted to at least 95% of the maximum standard Proctor density. Care should be taken not to overcompact the backfill or use large equipment near the wall, since this could cause excessive lateral pressure on the wall. Some settlement of deep foundation wall backfill should be expected, even if the material is placed correctly, and could result in distress to facilities constructed on the backfill. The lateral resistance of foundation or retaining wall footings will be a combination of the sliding resistance of the footing on the foundation materials and passive earth pressure against the side of the footing. Resistance to sliding at the bottoms of the footings can be calculated based on a coefficient of friction of 0.45. Passive pressure of compacted backfill against the sides of the footings can be calculated using an equivalent fluid unit weight of 350 pcf. The coefficient of friction and passive pressure values recommended above assume ultimate soil strength. Suitable factors of safety should be included in the design to limit the strain which will occur at the ultimate strength, particularly in the case of passive resistance. Fill placed against the sides of the footings to resist lateral Toads should be a granular material compacted to at least 95% of the maximum standard Proctor density at a moisture content near optimum. Job No 104814 -7 - FLOOR SLABS The natural on-site soils, exclusive of topsoil and clays, are suitable to support lightly loaded slab -on -grade construction. The clays are expansive and should be removed from beneath the building area. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with at least 50% retained on the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site granular soils or suitable imported granular soils devoid of vegetation, topsoil, clays and oversized rock. UNDERDRAIN SYSTEM Although free water was not encountered during our exploration, it has been our experience in the area and where clay soils are present that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below -grade construction, such as retaining walls and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish Job No 104814 -8 - grade and sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 11/2 feet deep. SURFACE DRAINAGE The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in paved areas. Free -draining wall backfill should be capped with about 2 feet of the on- site finer graded soils to reduce surface water infiltration. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Irrigation sprinkler heads and landscaping which requires regular heavy irrigation, such as sod, should be located at least 5 feet from foundation walls. LIMITATIONS This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either Job No. 104 814 -9 - express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory borings drilled at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory borings and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified so that re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. Respectfully Submitted, HEPWORTH - PAWLA EO Jordy Z. Adamson, Jr., P.E. Reviewed by: D L Steven L. Pawlak, P.E. JZA/djb Job No 104814 NOT TO SCALE LOT 11 LOT 10 LOT 9 rBUILDING ENVELOPE • BORING 2 BORING 1 • RED CLIFF CIRCLE / LOT 8 104 814 HEPWORTH—PAWLAK GEOTECHNICAL, INC. LOCATION OF EXPLORATORY BORINGS Figure 1 Depth — Feet 0 5 10 BORING 1 BORING 2 25/12 10/4,10/0 WC -10.1 D0.107 22/12 29/12 •C-5.1 00.111 -200-40 40/12 O. '1 5 D0- 0los 60/12 0 5 10 15 15 Note: Explanation of symbols is shown on Figure 3. Depth — Feet 104 814 HEPWORTH—PAWLAK GEOTECHNICAL, INC. LOGS OF EXPLORATORY BORINGS Figure 2 Compression — Expansion % Compression % 3 2 1 0 1 2 3 4 0.1 Moisture Content = 10.1 percent Dry Density = 107 pcf Sample of:Sandy Silty Clay From:Boring 1 of 5 Feet Expansion upon wetting 0 1 2 3 4 .0 0 APPUED PRESSURE — ksf 100 Moisture Content = 5.1 percent Dry Density = 111 pcf Sample of:Silty Sand Matrix From: Boring 1 at 10 Feet Compression upon wetting 0.1 1.0 0 APPUED PRESSURE — ksf 100 104 814 HEPWORTH—PAWLAK GEOTECHNICAL, INC. SWELL—CONSOLIDATION TEST RESULTS Figure 4 Compression — Expansion R N O Moisture Content = 9.5 percent Dry Density = 105 pcf Sample of: Sandy SHty Clay From: Boring 2 at 4 Feet D Expansion upon wetting 0.1 .0 0 100 APPLIED PRESSURE — ksf 104 814 HEPWORTH—PAWLAK GEOTECHNICAL, INC. SWELL—CONSOLIDATION TEST RESULTS Figure 5 Job No. 104 814 HEPWORTH SOIL OR BEDROCK TYPE Sandy silty clay Silty sand matrix Sandy silty clay UNCONFINED COMPRESSIVE STRENGTH (PSF) ATTERBERG LIMITS 1 PLASTIC INDEX (%) LIQUID LIMIT (%) PERCENT - PASSING NO. 200 SIEVE 40 I GRADATION _ 1 0 GRAVEL (%) NATURAL DRY DENSITY (P=0 h O - — —. - un 0 .� NATURAL MOISTURE CONTENT l%) O V; on 1 SAMPLE LOCATION 1 DEPTH (R) Br O NI - O 2 O m N COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 0 3s? AelGce (VA- Permit No. 931.3 3 I have this day inspected this structure and these v1 premises and found the followin4 corrections needed: /toxo(. Q rteh, LTA 4n 3)ieAsearg, C �4,„,aptere, You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 6 th /06 20 Building Inspector .zj" :— Phone (970) 945-8212 No 9 i-� 53 Assessor's Parcel Noc 195. -0271l -1(o-4009' /� �pate(..C1-Q1- G� UILDING PERMIT C : D CC ��`,,--JJ 9 Job A ess 75c- . P B.. ��J `-i attic. r D Owner C PY5 B G .I AddressS JR L tua.. 4 g -kilic Phone '--5521-1 E R - .«c -F Contractor Address f Phone ` —a S Setb ks: F ��• n Rearr, RH LH ..--7 Y 630 5/ �' ' /• INSPECTIONS Zoning Weatherproofing ooting -Z8-0S /Olt- Mechanical Foundation fS 1$-Ds741-11-13-u57jFt/Q -Z7-c57g Electrical Rough (State) Grout Electrical Final (State) / Underground Plumbing I1-3- 1i -712-Final 6-3-06. mp /Checklis Qted? Rough Plumbing - Certificate Occupancy # Framing 3-4YSt;! Date -a7-O6 Insulation 3-)7-c67*- Septic System # tiV Roofing Drywall S -ca3-064?�t Gas Piping �2-z8'-o(,�Ti3� Other NOTES Date Final 4C)Oa/��cz ?SuCT3,31-4 9.0,1$100 continue on back) 3/31f tic BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issue • • ..l. .Zoned Area Permit No. ..t'wr3.r? AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector an, IMME I;ATELY BECOME NULL AND VOID. Use Address or Legal Description OwnerreStAstSanSta as V Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing ?_25- o S ,vim 1 Driveway Nil] Foundation ,_ r-iR7cP ttt►t:Pr,/ Sq-jtot-v , , Underground Plumbing /( -3-o »') , Insulation 5-/ ?air . Rough PlumbingL.. Z'- 7-- Drywall i Chimney & Vent r .. , ,. •, r•,6I Gas Piping A=4.5( -0(a Final (2-2.3-oG2z1/ Electric Rough (By state i,r,„ Septic Final Framing 3 -I ii -0 0-15- (To include Roof in place and Windows and Doors installed). Notes: , .r, ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Fur Inspections Call 384-5003 P 1b i dais, APPROVEDDO NO DES I RIP, riaanAi L<nu Intl ,e.. ,olho-aciu