Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County Building & Sanitation Departtnent 108 8'" Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job Address_, �y Nature of Work Building Permit' 1qLi)�= P_ k -ice NO. cJLko 0 MP) rBal_v 3 Lc t- Use of Building Owner Contractor i LLC al MIA /t`111D Q -S Amount of Permit $ 3 349 • CpcI Date GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8th Street, Suite 201, Glenwood Springs, CO 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 Permit No: 94(0as ParceUSchedule No: t2 1 t-1 - 3 if i- 07-0,10 AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTIIER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN LN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) D,ic') 3'`40 �' t 1ems-'o,}6- Address: 0 z0 0,1. \ (� Rep cr S- �7� 6b / p AJ 1� 1 Lot No: / Block No:lSu tcemptipn: I Elk Jv 2 O ner 0-r fa_ ziC A drEss Ph: W h: V arc:�dd 1 A irk,k (4- ��.�Lie I li,. o' 5-0 rid 3 Co aaoc----� dress: Ph: Lic. N . i 4 ✓ � . hL jf w�-__ l /10 4 Arc itec'(/igineerj� Address: Ph: T Lic. No. e. (R S i'\ � t8 � 6 i qhs (V C---- 5 Sq. Ft of midi g 3l I Sq Ftµoff l el i ,fG ,e S Height: Np of Flpors: p r,(, 1,- �C,` 6 Us ('� /' r9 7 Describe Work. ��..-..;�"' /Y t 8 Class of Work: New o Alteration o Remove ❑ Addition ❑ Move 9 Garage: a Single Double Carport: o Single o Double 10 o Driveway Permit ❑ On -Site Sewage Disposal o Site Plan (Septic) 11 Valuation of Work: $ i� �C1 u iJ G✓ Adjusted Valuations: oC,3 Y+') 12 Special Conditions: Apo,Joists AsS 05/.0R, C ..pis- -p NOTICE Plan Check Fee: Permit Fee: A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE STATE a /� sI] 13 ISSUED BY THE OF COLORADO. L 3 V .� r t oz R 75- THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION Total Fee: Dated Permit Issued: AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. q ,t ^' �� 3 347 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS OCC GrOkk[!p•"- Const. Type: APPLICATION AND KNOW THE SAME TO BE 'PRUE AND CORRECT. ALL 7 lat., PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE ...en" COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE Zoning: Setbacks: GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. 3 Manu Home: ISDS No. & Fee: ..../6, 400,4,... 1�M1 R Sir IF , .sem Ptd B 1 DEPT.`. - h.PLNG.D PT. - - APPROJIAL/FATE APPROVAL/DATE AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTIIER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN LN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garfom.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL) D,ic') 3'`40 �' t 1ems-'o,}6- The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. All bathrooms must be complete, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all IBC and IRC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made; 8. A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupanc,yyuse and the issuance of a Certificate of Occupancy for the dwelling under building permit # ' t-1tc > . Signature BpcontOct2004 3 b )loc Date Applicant g Address Date !t- ?g.(c VALUATION/FEE DETERMINATION c Finished (Livable Area): Main ) Upper Lower 14 Other Total Square Feet Valuation Subdivision C4 Lot/Block 7 Contractor Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation 4 2a 4 / 4& Valuation Decks/Patios: Covered Valuation ! q 5'>v 24 Open Valuation 3 Total Valuation 3 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within Me envelope. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streas or water courses? Yes /DpU 2 Does the site plan indicate the location and direction of the County or private road accessing the property?, Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing s el in accordance with the IRC or per stamped engineered design? Yes_ 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and ctleclearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads an wind loads? Yes 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns and,beams? Yes 12. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roofer the top of a flat rot? (Building height measurement usually not to exceed 25 feet) Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes / No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes i` No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes X No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will not be accepted without it. Yes X No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimension a home can be on a lot is 20ft.wide and 20ft. long? \ , Yes X No 4 24. Have you designed or had this plan designed while considering building and other construction de requirements? Yeses No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes No 27. Do you understand that approval for design and/or construction changes are required prior to the applicatio of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact or "Septic System" fees required, at the time you pickup your building permit? Yes No 29. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in too 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a 50.00 re -inspection fee? Yes No 31. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupant he building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRCZ, Yes No 33. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of licable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building perrnr application? Your attention in this is appreciated. Yes No 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes No (please check with the building department about this equirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Signature of Owner Date Phone: 1 if SH- U..SD (days); q{)1 CP1 Project Name: S fit[,, Project Address: r PK S Sr Q-w()I{,'v (. "C 1v city /j (evenings) Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application 6 may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqFeb2005 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC,.IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload: 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000%t. 75PSF 8001 to 9000ft. 100PSF 9001 to 10000ft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B o` C (see section R301.2.1.4) Frost Depth: 36in. to.8000ft. elevation. 42in. 8001 and above. Winter Design. Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F -days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R -Values: • Ceilings/roofs R values are: R-30 stick built structures.. R-38 log construction and steel rafter construction. ■ Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. ■ Floors R -values are R-19. • Basement wall R -values are R-10 below grade, R-19 above grade. ▪ Slab perimeter R -value and depth is R- 10/36in. • Crawl space wall R -values are R-10 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. Applicant PLAN REVIEW CHECKLIST Date 4 -tic „„ Building 1../ Foundation Driveway Permit Surveyed Site Plan n �,4Septic Pe„iut and Setbacks Cir -7 - Grade/Topography 30% -" 11 Attach Residential Plan Review List `ilVIini um Application Questionnaire Subdivision Plat Notes Fire Department Review L Valuation Determination/Fees `'Red,,Line Plans/Stamps/Sticker Attach Conditions iplication Signed lan Reviewer To Sign Application el/Schedule No. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building Height Zoning Sign -off Road Impact Fees HOA/DRC Approval Grade/Topography 40% Planning Issues Subdivision Plat Notes 23 05 06:10a RECEIVED APR 1 1 2005 GARFIELD COUNTY BUILDING & PLANNING T•d District 1 970-945-1318 Garfield County Road and Bridge, District 1 7300 Hwy 82, Glenwood Springs, CO 81601 970-945-1223 ph. 945-1318 FAX Date: 03-22-05 To: Building & Planning From: Bobby Branham Re: Driveway permit exemption For. Keralsa LLC P.O. Box 667 New Castle CO 81647 Ph. 989-5014 Fx. 945-0552 Location: Lot 13 Western Hills Subdivision Glenwood Springs CO 81601 Scope of Work: Obtain building permit Road and Bridge Concerns: This property lies outside the system of maintained county roads, and is therefore exempt from County driveway permit requirements. Bobby Branham Dist.1 Road and Bridge 2SS0-S46-0L6 addza ane0 p. 1 dEO:aT SO TT Jdu COUNTY OF GARFIELD - BUILDING DEPARTMENT CO ECTR NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at566 /0 C Permit No. / 40 I have this day inspected this structure and these premises and found the following corrections needed: 1.614, f You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 2' 54) 20 Building Inspector �G Phone (970) 945-8212 COUNTY OF GARFIELD - BUILDING DEPARTMENT CO RECT!I•, N d • ;� 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 01/4/70 /Z 4/2" Permit No. 99(04 I have this day inspected this structure and these premises and found the following corrections needed: �r91T!_/C *Sb sS iieno up ifssores 6` o i ks In. cS f ///$fltS t o {SioF-J i sw,„ZA"/ �v� ® H -Q440 goo in-- . f..ok13-e1^-e-ev4,/� - v I G is 1427 You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 9 -13 -or Building Inspector 7741 Phone (970) 945-8212 Date: 7- 3-o6 To: jak (4 , cfof 0 20 51 ar-nA Garfield County BUILDING & PLANNING DEPARTMENT Code Compliance Office Dear Permit Holder, Please refer to your building permit number 9560 , issued`/"/`/'os A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since 5--3o-6.5- Please be advised that building permits expire, per Uniform Building Code, section 106.4.4 and International Code Section 105.5. "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or workauthorizedby such - permit is suspended or abandoned at any time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, provided no, changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work. If you have not responded within thirty days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Clerk and Recorders office that indicates that the work permitted per Colorado Revised Statutes 30-28-205 & 210, was not inspected, is not approved and that the building or area is illegal to occupy and is subject to legal abatement action. Thank you for your cooperation. Sincerely, - moi/ Tim Sodilay Dave Mead Matt Provost Building Inspectors 108 8th Street Suite 201, Glenwood Springs, Colorado 81601 (970) 945-8212 (970) 285-7972 Fax: (970) 384-3470 COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at U Permit No. ?ye,K9 I have this day inspected this structure and these premises and found the following corrections needed: ;'-3c 2-a 5 / lid- Ole: r /L"d-e-rte 2) G A -r You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /2 3 `c i 200 Building Inspector --_->P2.1.-,,..7(770•27,./;.7. Phone (970) 945-8212 COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 0w5-367 Permit No. 9'9- 6, 0 \ I have this day inspected this structure and these Lci premises and found the following corrections needed: \ A p,ei E'`S5 , ekto.s itt er ,(imE' C4a of .5 c C,E4SSGPA/ i� i✓��;. a A/,v4Z-, ✓ o77 GT VC S4g,g t/6 C/✓ 671-s- 2._/)(70 /Js2._//✓9c /£71/772-A/di/&- ri/crCt%l cg, M4) -s -171n ,e/s 7 — VA;(/ /ila Atig--- 41/5774 et I4GL /V VAC. ,6,e/e ci 3 GUrAr///CC4 -s`Z?E'/P SWS1.57/VZ- ,GAc,< 2700,E \ ,5"/CA C4Xc/ S //✓ S'�ow, +� , \\ /Ve, //oi aJ47 ,C 71" "et-z/eic • \ //©e' t(c2V- ' 4AL- ©/t( Call for Re -Inspection 650.00 Re -Inspection Fee must be paid prior to Re -Inspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 3 /16 Building Inspector Phone (970) 945-8212 COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St , Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ac ---so c < 4/ C� ' Permit No. 9t 6 6 I have this day inspected this structure and these premises and found the following corrections needed: /f2/Se../ 7 2 4/ /4/4T4s'g jn'2 /% Gly OV 5 � c✓. '/z & vA/ p tic. -t- Pie c_XiA/o- )6,5 /721/C ✓o-.45/721✓C 4 C/,%f7/2A 0A /f1-5j� p ,eil/9414- ,C$ />V5i r- `/,A /&7 /A7/"ArG iciAG.LS t- S/7 eVestre fl -403../07 4- CC/LS ❑ Call for Re -Inspection ❑ $50.00 Re -Inspection Fee must be paid prior to Re -Inspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date / > e" kir Building Inspector Phone (970) 945-8212 03/27/2009 15:14 970-876-0864 Inspection Report PAGE 22 Page 1 of 1 COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT l CORRECTION NOTICE Date Received: 27 -MAR -09 Permit Number 657824 ContractorlHomeOwner: Address: Type of Inspection: Action: Comments or Corrections: L2K2 ELECTRIC, INC. 580 Melray Rd Final Accepted Inspectors Name: Robert Fuller Phone Number: 970-947-8902 Date: 27 -MAR -09 COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https://www.dora.state.co.us/pls/real/Ep Web Inspection GULProcess Page 3/27/2009 if c Job Address ssessor's Parcel No i x 1 19 -m- - ryg Date BUILDING f RMIT CARD n 000 (Y\ -c_D. i Y3,\Hc3 7 lAD Owner GII.G@ Q, ,�-��� AddressO // ,jw( 6 Phone Contractor -k ;E- s pt( Address '31/- 4 (Otinfi, Set/b�cks: Fr.{ n R7, -,),,,S RH LH C�It r t� ( . ' L 2GCG INSPECTIONS P4Ve j Soils Test Footing t -f -2?-OS neif---^CYJI1( 0S4- Foundation5-2-05 Grout Underground Plumbing ,,PWoline Rough Plumbing 9-/3-csild- Framing Insulation a' Roofing Drywall r1- So *--O Gas Piping Weatherproofing Mechanical Electrical Rough (State)$'Z• Y"'" - Electrical Electrical Final (State) ";3—/ Final ¢ 30-09/Checklisi, Com leted2 Certificate Occup ncy # 07,;(0K Phone # Zoning 2:319- s'o/1- 79_ Se z-3 0 NOTES Date Septic System # Date Final Other (continue on back) INSPECTION WILL NOT E MADE U LESS THIS CARD IS POSTED N THE JOS 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO /. Date Issued ../.�«. ' -. Zoned Area tt Permit No # AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use C)/ (!-(fr "":' :'" K i .'N fa ` Al Address or, Legal Description 05Ra \^� �' .%. G.05 s Owner nieraw, L 1....C.. Contractor Setbacks Front Side Side This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. Rt.. NSPECTION RECO Footing "("- 2,Z- -- Cn 7—sb Driveway Foundation 51, -0576‘.--4,07-5_ Underground Plumbing5 -zs Rough Plumbing q,13-0,-- Chimney 1 t3_o5Chimney & Vent Insulation Drywall (1/- 3V -05f) Electric Final (by State Framing 07,13 -cc- (To include Roof in place and Windows and Doors installed). uniunalumuninstur ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. Septic Final Notes: Aeei) At; Yazk c(tnStn Amps THIS PERMIT IS NOT TRANSFERABLE For Inspoetions Call 384-5003 108 8th Street Glenwood Springs, Colorado Ni T IIpESTROY THIS CA! APPi COVED " Date ,1,* By PLACED OUTSIDE -COVER WITH CLEAR PLASTIC EXISTIN6 MOULDER WALL GENERAL STRUCTURAL NOTES GENERAL REOUIREMENTS I. Design Is based on the 2003 edition of the International Residential Code (IRG). 2. Brian Kurtz, P.!. of Kurtz t Associates, Inc, Inspected the existing boulder walls on 04/21/200q, and found the wall• to be in good condition with no signs of distress or excessive settlement. 3. All dimensions, elevations and details on structural documents shall be verified against existing conditions prior to construction or fabrication. 4. The contract structural documents and specifications represent the completed structure. The contractor shall provide all measures necessary to protect the structure and existing adjacent structures and utilities. FOUNDATIONS I. Foundation Design 1 based on assumed soil properties. Soils are presumed to be non -expansive, non -soluble, and not prone to excessive consolidation. 2. Avoid excessive Hottingor drying of the excavation, keeping the excavation reasonably ree of rioter during placement of footings. AUTO COURT EXISTING BOULDER "ALL &ARA6E 30ULDER WALL : FLAN VI EA 5/16 1'-0" PLAN 4010 NORTH * SAY, 1' 1', KURTZ ASSOG I ATES, NG . 5012 COUNTY RD. 154 GLENWOOD SPRINGS, COLORADO (1170) '145-6305 BOULDER RETAINING WALL : 0580 MEL RAY RD, SUBDIVISION GLENWOOD SPRINGS, COLORADO DRAWN BY: CHECKED BY: B.J.K. SCALE: AS SHOWN PROJECT #: OQ-II DATE: CONSTRUCTION 5E7: 04/22/Oci SHEET TITLE: GENERAL NOTES, WALL PLAN VIEW SHEET: s = i 9 2 (+/-) ASPHALT SURFACE 1=- 41 2'-0" TO 3'-O" do. BOULDERS (LOWER 3 COURSES MINIMUM) SINGLE TIERED WALL: "r'-0" MAX. HEIGHT 1/2" • l'-0" ( 1 1/2" • I'-0" CA 6" OFFSET TYPICAL 4'-O" I'-6" MINIMUM BOULDERS 6 UPP'E'R COURSES LIMITS OF EXCAVATION PROVIDE 50% INIMUM COVERAGE H/ DOUBLE SIDED DRAINAGE MAT 2'-0" TO 3'-O" dia. BOULDERS (LOWER 3 COURSES MINIMUM) Nt- PROVIDE CONTlN1OU' 4"PERFORATED DRAIN PIPE - SLOPE 2% MINIMUM TO DRAIN 2 (+/-) ASPHALT ASPHALT SURFACE SURFACE 1/2" • I'-0" 1 fi 2'-0" TO 5'-O" dia. BOULDERS (LOWL°R 5 COURSES MINIMUM) �,.• SAY vO QQ :co =::.. _- 187 • KURTZ ASSOG I ATES, NG. 5012 COUNTY W. 154 GLENWOOD SPRINGS, COLORADO (q 70) q45-6305 BOULDER RETAINING WALL: 0580 MEL RAY RD. SUBDIVISION GLENWOOD SPRINGS, COLORADO DRAWN BY: M.C.E.K. GHEGKED SY: B.J.K. SCALE: AS SHOWN PROJECT #: OGi — II DATE: CONSTRUCTION SET: 04/22/0q SHEET TITLE: RETAINING WALL DETAILS SHEET: S---2