HomeMy WebLinkAboutStructural Steel Inspection Report 02.11.2015THUNDER MOUNTAIN TESTING 2970 N. Ronlin Avenue / Grand Junction, Colorado 81504 Office (970) 256-9965 / Cell (970) 210-7008 / Fax (970) 314-7067 E -Mail: kxkid39@aol.com TPI Industrial Inc. 2471 River Road #A Grand Junction, CO 81505 ATTN: Mr. Mike Drake RE: WPX Energy Pad Site: WPX KP 13 - 17 Parachute, CO *Field Inspection Dear Mr. Drake, February 11, 2015 Job: # 7053 Project: WPX - Kokopelli #2 Permit: # BLCO — 10 14 3422 As requested, structural steel inspection was conducted per the IBC 2012 Edition - Chapter 17: Structural Tests and Special Inspection and Garfield County requirements. I cd on site at 9:00 AM. I met with Mr. Mike Ballew with TPI Industrial Inc. to review project requirements and job specifications. The steel erector for the project is TPI Industrial. Visual inspection was conducted at the Lower Roof f=raming Plan level on the 5/8", j/4", and 7/8" ASTM A325 high strength structural bolted beam to beam and beam to column connections at grid lines A - B & 1 - 3 of the approved job site drawings provided by B&C Steel dated 10,4/2014. Project requirements indicate "turn of the nut" tension requirements. As a minimum, 10% of all bolts, but not less than 2 bolts per connection were inspected for periodic inspection requirements. All ASTM A325 High Strength structural bolts inspected were observed to be adequately tensioned to project bolt tension requirements. Respectfully Submitted, Aaron M. Stanfill AWS CWI #13090151 Thunder Mountain Testing /loan M S CW1 13090151 0C1EXP 9111141% Rev fd by, Scot L. Max 11 AWS CW1 #91040201 ICC Certified 40863569-S1 & S2 ASNT NDT Level III #30242 Thunder Mountain Testing Scott L Maxwell CW1 91040201 OC1 EXP 4/1/2015