HomeMy WebLinkAboutOWTS Installation Observations 07.05.15 July 5, 2015 Project No. C1133 Terry and Heidi Ruonavaara thruonavaara@msn.com Onsite Wastewater Treatment System (OWTS) Installation Observations 160 Springridge Drive Garfield County, Colorado Permit Number SEPT-3-15-3559 Terry and Heidi, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on June 24, 2015 for the subject property. Silt Mesa Excavating installed the system. The installation included a new 1250-gallon, two-compartment Precast Concepts concrete septic tank with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Effluent gravity flows to a distribution box, accessible from grade, and then to four gravelless chamber trenches. Each trench consists of 22 ‘Quick 4’ Infiltrator® chambers for a total of 88 chambers and 1056 square feet of infiltrative area. Six-feet of undisturbed soil was present between each trench. Inspection ports were installed on both the beginning and end of each trench. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OW TS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P.E. Septic tank Baffle wall Inlet tee Effluent filter, prior to installation Effluent filter installed View of distribution box and trenches Trenches, 4 rows of 22 Quick 4 chambers 832‐R‐13‐002