Loading...
HomeMy WebLinkAboutApplication- PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Offlce:970·945-8212 Fax: 970·384-3470 Inspection Line: 970·384-5003 Building Permit No. Parcel No: 2125-251-00-015 ~~--. ~~ Locality: Job Address: ~~~ ·~--~0007 Navajo Trail, New CastLe_ ___ ~ Use of Building: __ ~---'C:..::o=ld mudroom/ s!Qrag'-"e~~ Owner: Wampler, Wendy & Bontrager, VJYm.~an~- Contractor: Owner Fees: Plan Check: 108.71 Septic: Bldg Permit: 167.25 Other Fees: Total Fees: $ 275.96 ·"·~·-·--~~ Moo-- Clerk: --~\U't\0~ Date: L~L~,c_t I 2 3 4 5 . GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 81h Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-82I2 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield-countv.com Parcel ~o: (this infonnation is available at the assessors office 970-945"9134) ~--\~ ~--~"S \ -()()-() \S Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description 6001-fV 1-WI\-)0 Til.~,' I N&-10 Cl\-!.ri..S (O ~ lll'\-1 AltPh; AltPh: 6 Arc~~ng:;'(Z~ ~-~ Mailing Address: )Y Ph: lJ-AltPh: Sq. Ft. of Building: Sq. Ft. or Acre1 of Lot: Height: . i d • I fl-U' f <; I \.e,. 7 8 9 Describe Work: l 0 Class of Work: aNew o Alteration V' Addition II Garage: Septic: o Attached o Detached o ISDS 12 Driveway Permit: Owners valuation of Work: $ NOTICE No. of~!5!ors:_ ~ o Corrununity Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate penn its may be required: ( 1) State Electrical Penni\, (2) County JSDS Permit, (3) another permit required for usc on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Pcnnit becomes null and void ifthc work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION ! hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or oll my bchalf(submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structurc(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land usc regulations (County Regulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or usc of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable Jaw. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Pc11nit docs not prevent the Building Official from: (I) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or usc ofthe structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including withoUt lumtat!On my arcllltcct dCs1gncr, cngmcer and/ 01 buJlder I HEREBY;;O::; ?1READ AND UNDERSTA~ THE N;;:&;:RTIF!CATION ABOVE - OWNERS SIGNATURJV / DA':t#--------------------- STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fe\\, / 7 $" Manu home Fee: Mise Fees: 'lf.FZ..O (b IO?J1l t)' P"' ISDS Fee: Total ;I;)q Y Fees Paid: Ba~~~e:b~ BP ~ssue Date: ISDS No & Issued Date: ,6 ~ .. ~, IIOo+6 Setbacks: OCCGroup: :r-ec Const Type: Zoning: BLDG DEPT: PLNGDEPT: I l.ll \1 h l-1-\1,., ~o8" J \ ILL \...\-\L.. ·oX' APPR I DATE APPRQ >V.\\f\\1 DATE ~ The following items are required by Garfield County for a final Inspection: I) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date -'W':-a:::m;:;Po:,:l:;;er:..,..,-_.-::------'---Subdivision 0007 Navajo Trail Lot/Block · -"4":'/1:':6':/2:.;0::;:0:;;8=="'-------,.----Contractor Finished !Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 sf X $33.68 450 sf X $18.00 sf X $9.00 sf X $24.00 60 sf X $12.00 Commercial sf X sf X sf X sf X sf X sf X DeitzExp Owner 0.00 0.00 8,100.00 0.00 720.00 0.00 8,820.00 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a pennit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. I Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located wi.thin the pnvelope. Yes v 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County· Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. J Yes ---- 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), rreams or water courses? Yes tJ A 4. Does the site plan indicate the location and direction of the County or private road accessing the property? ~ Yes ____ _ 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge pennit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for otheragen~ Yes ____ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordan/ith the IRC or per stamped engineered design? Yes ____ _ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes v No ----- 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? v Yes _____ _ No ----- 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? .j Yes _____ _ 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof constructio~ Yes, _____ _ 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof raftervor joists or trusses? Yes, ______ _ 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes /J )/) 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes / 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II ce&fications or phase II EPA certification? Yes No ______ _ 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? / Yes. ___________ No ________ _ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes V' 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation f~ll habitable rooms? Yes __________ _ 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes No /'? ·----- 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? V Yes __________ _ 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision p~ess, are building plans in compliance with all plat notes and/or covenants? Yes ________ _ 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or sljbstantial modification of the plans. Yes _____ J-=----- 22. Will this be the only residential structure on the parcel? Yes v7 No Ifno-Explain: __________ _ 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes V 24. Do you understand;that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Y es. ______ _,i!_,___ 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes -./ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes ~ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes / 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes __ -4--- 29. Do you understand thatthe Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes __ "'--- 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes _ ___,'----No _____ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-i~jspection fee? Yes_--'rJ"'---- 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ___ -""'--- 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Y'ent and that the party responsible for the project must comply with the IRC? Yes _____ _ 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable ins~on. Yes ________________ ___ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes J 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes ________ / _____ (please check with the building department about this requirement) 3 7. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes c/ 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to b: ~!,d and the connections inspected by the service provider prior to the issuance of a CertificatJ Occupancy? Yes _______ _ I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Date Phone: 98 tf Mloq (days); q [L/ ;)_O(pq ProjectName: lD11vM~lv jr3omr0i§ (Jr MVd!07J')--y--J ProjectAddress: en /Jttv'J'rJ +l'ot.'l I New Urs!(p 6 (evenings) Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to ·first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 7 PLAN REVIEW CHECKLIST Applicant 'w~e't#L Building ~ngineered Foundation \,.../"Driveway Permit ~x:-"'il-..v l./Surveyed Site Plan li}k_septic Permit and Setbacks ~Grade/Topography 30% ~ach Residential Plan Review List __tLMinimum Application Questionnaire 4-Subdivision Plat Notes ~ire Department Review Jvaluation Determination/Fees ~d Line Plans/Stamps/Sticker 4-Attach Conditions UApplication Signed ~an Reviewer To Sign Application LParcel/Schedule No. 440# Snowload Letter-Manf. Hms. 1 / Soils Report GENERAL NOTES: Date ___ t......~I_-_,\_,.L.,_-::..;d\/"'-"'-- Planning/Zoning ----l.L3'roperty Line Setbacks ___L.L30ft Stream Setbacks ~Flood Plain l.L'Building Height ~Zoning Sign-off ~Road Impact Fees VHOAIDRC Approval _L'arade/Topography 40% -t,.LPlanning Issues __ Subdivision Plat Notes (--~·-·-· -~---~-----, -,_---.-., ~----~------- i No 10896 . ----------~~~----Assessor's Parcel No. 2125-251-00-015 Date 4/18/2008 BUILDING PERMIT CARD Job Address ----~O~O~OL7~N~a~v~aj~o~t~rn~ii~,~N~e~w~C~a~s~tl~e~(~D~ie~tt~Ex~e~m~pt~io~n~.JP~a~re~ea1~4~) ______________________ ___ Owner ______ -...!.W~a~m'-"p"-'1"'-er'-'&~B~o~n~tr,_,a~g"'-e'-'r ____ Address 07 Nanavajo trail. N'casthPhone # 984-2069 Contractor _____ _:::O:.:.w:.:n:.::e:.:.r ______ -'-------Address ----------"s""a"'"'m""'e:......... ___ Phone # ______ _ Setbacks: Front ______ Rear ________ RH ________ LH _____ Zoning _______ _ cold mudroom/ storage INSPECTIONS Soi Is Test ---=-..,...,--::=-=-..,.,----,.------- Footing 'S'}--;D5 lJd\. Foundation ~ Weatherproofing ___________ _ Mechanical _______ -:r----=--::::--- Eiectrical Rough (State) /CJ -Z. 8' -o 8 Grout IV frr Underground Plumbing---""?!;""@"------ Rough PI u mbi ng _ _.,f)['"""'_.l.__tl ________ _ Framing 1/,./3<78'~ Insulation 1/-J.?J-<78" ~ Electricaj,Fjnal (State) ______________ -TT~ Finall-b1TJ /Checklist Completed? !Ofh Certificate Occupancy # --------- Date Septic System #-,\J...-r.lA,...----------- Roofing --::,---=-=-----c=:------::==r--.---- Drywall [-Z Z-c? ?' ;;;;::?';(). Date ----------------Final _____________ _ Gas Piping ___________ _ Other _______________ _ NOTES INSPECTION WILL NOT BE MADE UNlESS THIS CARD IS POSTED ON 'THE JOB 24 IHIOIIJR§ NOTiCE RfcQimUW FOR iNSPECTIONS BUILDIN PERMIT 0 GARfiElD COUNTY, COlORADO Date Issued.~~~lt-:g .... Zoned Area ......................••...•... Permit No .. 1.0.~ ......... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use ('flfc/ JIY!OdlooY-l f 5/iii£r;e Address or Legal Description 000} IVOVq)O lfq[/., , New &151/e Owner ~Jamfll'll, wencJy r &yi®y/fi t!Jy~iracto.L12.Wl!!.!»ru~fk. ----- Setbacks Front Side Side Rear ThiSTard'Musdle-Posted So !iTs Plainly Visible From The Street Until Final Inspection. ' INSPECTION RECORD Footing 5-'J-0?; A}rvj Driveway Foundation ?l).w ./' /1)/.kl Underground Plumbing g/.df solation II-J.!>~()x:,_,./Y-7 Rough Plumbing '-;17;;? Drywall /-c7-o'7 5< ?u2 Chimney & Vent /b Electric Finan (by State Ins~ l§fllf: 1/f.h Gas Piping .filii inal /-S: IV £.JriA Electric RoUigb (IBy Stale !$~f.'.ww) ~ . Septic Final Framing /1·<4 -0 8' ~ Notes: (To include Roo in place and Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND .. . THIS PERMIT IS NOT TRANSFERABLE For Inspections Call384-5003 103 3th Street Glenwood Springs, Colonvh APPROVED DO NOT DESTROY THIS CARD Date Lf--"---l-lll ~~-~ By f .\o~ ~ \ IF PLACED OUTSIDE-COVER WITH CLEAR PLASTIC COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ()00 1 '/1~ Permit No. / () 8 9C<z Call for Re-Ins ection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. ~ 20 Qi{_-=-7'1- Building Inspector --t~~~""'L-L.:..=:=::::..= _______ _ Date h-\'6 Phone (970) 945-8212 COUNTY QF GARFIELD -BUILDING DEl CORRECTION NOT~ 108 8th St., Suite 401 Glenwood Spring~ Phone (970) 945-8212 Job located at 000 7 lf11vJf[Q Z?A!t.., ;t(c, Permit No. /128 ?"C? I have this day inspected this structure and these premises and found the following corrections needed: z ?call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date ~-'5: 20 _cP~2f~- Building Inspector ----""';:r---'--'-/--"'ft1"-+---l"kt-"'/;'""I''-<·~~S:~o..,,Ad.L)_· -~ Phone (970) 945-8212 I I I I" I~ I~ lo I' I~ IQ lr 15 I" I I I ' ',, SCALE 1 '=60' IMPROVEMENT SURVEY f-- {/) ~ > <I z 30.00' Addition Sirlg\e f"llm~y Res~= Const-Block ancl 'Wood r wn hereon does oot lie b)ect property sh? flood Stl>temen~,:~ ;ulOO year flood p\Ciil'\ N.88'1.0'00'E. 39.82 (xemptlon. OCCO(\fug to the tlor. Parcel 4, Dtetz f!ed for record Legal Descrlp ~1on "'at thereof, tiS f the records of e><e!>p• ,...tlon No. 364400 o Legend C PLS ll14060 • Found Rebar w I Alum. ap OF ouncl Atum. Pipe Ofouncl 5/8' Rebar ___ Set Back Unes Note: . serving this parcel A!l utmt.y hn~~cotion shown of S-63'1.1 '58'E. 45.95 '" ar~,b~~~t ore opproxlmote. $0! ' $' .-"'~ ~ c r ifica n' ;j,. c. Dale . . Bontrage~ Profession Colorado Reg!s~:fg408 Land Surveyor 07 Navaho ~ 81647 New castle, 59 · 97D-984-20 ~ -~ t\ ~ ~--· ~-{.. ~ ~ ' a ~31 ~ ~-~ '-... -......... .. / \\ I r;;;. I I "' --\~ l '-.. \1) -·~ -....... \.( ~ -~ ~ \-\) ·~ -\.:: £ '>.) lA ~ ~ ~ I ,h ~ \A "- I ~I ........ J \\ "' ~ "' I ~y/5-71!1&' ttov:56 tf,61f/H0 0 () ~~~0t(~o.r: P?5t tf place:_s , Page 1 of 1 Andy Schwaller From: sardogs@sopris.net Sent: Monday, September 08, 2008 11:54 AM To: Andy Schwaller Mr. Schwaller- As per your instructions, please amend permit #1 0896 from a cold mudroom to include electric, plumbing, insulation and drywall. Any questions please call 984-2069. The physical address is -0007 Navajo Trail, New Castle. Thank you for your help. Wendy Wampler 9/9/2008 SUBJECT TO NOTED ltXCEPTIONS & INSPECT!~ GARFIELD COUNT't BUILDING DI2~ARtM.EN' Ate :J_J_.L1:)rj5y _AJ_ _ FIELD COPY IGO IMSPECTION WITI'IOI!fil ' HIM I'U\N$ OH lim: "' Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Proper!)' Search I Assessor Subset Query I Assessor Sales Search Clerk & Recorde.LReception Search Basic Buildiug Characteristks I Tax Information ParceLDetail I Value.D.etail I Sales DeJ:.ail I Residential/Comnu~rs;ial Improvement Dei<!il Land Detail I Photographs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 013 II R130313 II 212525100015 II 39.877 I Owner Name and Mailing Address !BONTRAGER, WYMAN E. & WAMPLER, W. I7NAVAHOST !NEW CASTLE, CO 81647-9726 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:25-5-91 DESC: TR IN lsWNE AKA PARCEL 4 DIETZ EXEMPTION IPRE:ROI3052 BK:0817 PG:0003 BK:0674 IPG:0261 BK:0555 PG:0329 BK:0488 IPG:0761 BK:0446 PG:0342 BK:0446 IPG:0171 BK:0361 PG:0121 BK:0356 IPG:0299 BK:0032 PG:0503 BK:0892 IPG:0175 BK:0859 PG:0599 Location I Physical Address: 117 NAVAJO ST NEW CASTLE I Subdivision: I I Land Acres: 112.15 I Land Sq Ft: 110 II II http://www.garcoact.com/assessor/Parcel.asp?AccountNumber=R130313 I I I I I I I I I I I I I 4/2/2008 Parcel Detail Page 2 of4 \i=l =~Se;;;~t;:;;;o~n ==ilii=l =T~o~w;;:;;sh~ip"===HII= =~R;;:;;~~g~e ==ill 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 1os,oooll 8,3601 I Improvements: II 127,87011 10,1801 I Total: II 232,87oll 18,5401 Sale Date: 114/12/1993 Sale Price: 1110,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd 0 Buildings: I Residential Building Occurrence 1 Characteristics I I TOTAL HEATED AREA: 111,404 I ABSTRACT CODE·IISINGLE FAM.RES- . IMPROVEMTS ARCHITECTURAL STYLE·IIMANUF ACTURED WITH • ADDITION EXTERIOR wALL: IIMASONITE ROOF COVER: llcOMP SHNGL ROOF STRUCTURE: IIGABLE INTERIOR WALL: IIDRYWALL I FLOOR: llsHT VINYL I FLOOR: llcARPET I HEATING FUEL: IlGAS I HEATING TYPE: IIFORCED AIR I STORIES: STORIES 1.0 I BATHS: 2 ROOMS: 7 UNITS: 1 BEDROOMS: 3 http://www.garcoact.com/assessor/Parcel.asp? AccountNumber=R130313 4/2/2008 Parcel Detail II YEAR BUILT: 111993 II Tax Information I Tax Year II Transaction Type II Amount I I 2007 II Tax Payment: First Half II ($369.66)1 I 2007 II Tax Amount II $739.321 I 2006 II Tax Payment: Second Half II ($361.26)1 I 2006 II Tax Payment: First Half II ($361.26)1 2006 I Tax Amount II $722.521 2005 I Tax Payment: Second Half II ($361.34)1 I 2005 II Tax Payment: First Half II ($361.34)1 I 2005 II Tax Amount II $722.681 I 2004 II Tax Payment: Second Half II ($425.88)1 2004 II Tax Payment: First Half II ($425.88)1 2004 II Tax Amount II $851.761 2003 II Tax Payment: Second Half II ($478.38)1 2003 II Tax Payment: First Half II ($478.38}j 2003 II Tax Amount II $956.761 I 2002 Tax Payment: Second Half II ($455.36)1 I 2002 Tax Payment: First Half II ($455.36)1 2002 Tax Amount II $910.721 2001 I Tax Payment: Second Half II ($452.64)1 2001 Tax Payment: First Half II ($452.64)1 2001 Tax Amount II $905.281 I 2000 Tax Payment: Second Half II ($360.62)1 I 2000 Tax Payment: First Half II ($360.62)1 I 2000 Tax Amount II $721.241 I 1999 II Tax Payment: Second Half II ($358.70)1 I 1999 II Tax Payment: First Half II ($358.70)1 I 1999 II Tax Amount II $717.401 ThJ;l ofPag~ Assessor Databas~J:!S)JJJ'_ph Option!> I Ire.a.s:rn:erJ2atabase ~earchDpJ:ioJ!s Clerk_&: Recorder_Database Search Options http://www.garcoact.com/assessor/Parcel.asp? AccountNumber= Rl30313 Page 3 of 4 4/2/2008