Loading...
HomeMy WebLinkAboutApplication- PermitGarfield County Building & Sanitation Department 108 8"' Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 Job AddressjSv Nature of Work Building Permit Use of Building Owner NO. scoss i Contractor Cl -,n -a -L Amount of Permit $ Date Clerk Apr 27 04 02:55p TELEPHONE (9711) 945-8212 Battlement Mesa Homes (970)285-7303 GARFIELD COUNTY BUILDING PERMIT APPLICATION GARFIELD COUNTY (GLEN W OOD SPRINGS), COLORADO p.2 ��/ �)� INSPECTION LINE (970) 384-5003 App&rumple* rplele numbered spaces only PERMIT NO. 0. I PARCEL/SCHEDULE NO. J0B ADDRESS 1230 W Battlement Parkway, Battlement Mesa, Colorado ( Building "G', Willow Park Apartments) 1 LOT NO N/A BLACK NO: N/A SUBDIVISION/ EXEMPTION. Willow Park Apartments 2 owt ut Bartlenlerlt Mesa Partners ADDRESS P 0. Box 600U. Baukntent Mess rH. 285-7330 wK PH 285-7330 3 CONTRACTOR Battlement Mesa Homes. Inc ADDRESS P 0 Dox 601X1, Battlement Mesa PH 285-7330 wit PH 285-7330 4 ARCHITECT ENGINEER Greg RobSan ADORE% P.0 Bus 6U(, Battlement Mesa PH 285-7330 WK LH 285-7330 5 SO rt or eunwwc 4.312+8.625+4,312 YI eT OF LOT N/A HEIGHT 33' NO Or FLOORS 2 6 u... OF RUaDINC Group R Divrsrun 1 7 nesarUF ramie Aldr®Yr RIM'IB -,E 1(, 8 CLASS OPWCIRM 0 NEW 0 AD➢n1ON 3 AITFRAFIINJ ❑ MOVE 0 REMOVE 9 GARAGE N/A DSINGLF 0DUDbtt CARPORT N/A DsmeLL 0DOUB,E 10 ❑ DRIVEWAY PERMIT 0 ON SITE SEWAGE DISPOSAL(SEPDCI 0STEL PLAN 11 VALUATION OP WORT F AMSTED VA IUATIONS. S ; OJ /. op 12 SPECIAL L\)NDrONS A SEPARATE ELECTRICAL. COLORADO THIS PERMIT BECOMES NOT COMF.(E CTD ABANDONED FOR I HUIERY CERTIFY THE SAME TO BE TRUE OT WORK WILL BE CANCELCOF CANCEL y-.. CONST' •. BRIM �/ ii.r NOTICE PERMIT IS REQUIRED AND MILT IR ISSUED NULL AND VOIDS' WORK OR CONSTRUCTION WITHIN 130 DAYS LIR IF CONSTRUCTION OR WORK A PERIOD OF MO DAYS AT ANY TIME AFTER WORK THAT I HA VL RFAU AND EXAMNW THIS APPLICATION ANDCOIUIECE ALL PIIOV/5ANS OF LAWS GOVECJING COKALETEt) WITH. WHETHERSPECT1lED HEREIN .RAI)TUOES NV0THEE TO aVF AVFHLIRITY TO VISKINS OF ANY LITHE A ay.'AL LAW REGULATING /PL�RTORMAN . r,. CT; �4• SY THE STATE DF AUTHO€IZEDIS IS SUSPENDED OR HAS COMMENCED AND I VOW THIS TYPE 00. NOT THE VIOLATE OR 0' 1'LANOSECK FEE XA 2toQ 8 PERMTTFTE a 3 J TOTAL FEE- �6(7 �2 ` 7 � I T1 3 66 DATE PLRMTI ISSUED 6S �,.3 (KC GRcur ///'� ,t\ I CONST TYPE II —�f ZONING SETBACKS / ��a /'+N• .T �;/ `I,"zed .agrnl l..r,n5 r flc // �/ •ft / ' i �oirt, „/'// Bldg MANN HOMY 6LRNU & in �W A' Do 1 . aAr LIQ AGREEMENT PERMISSION IS HEREBYGRAN ILL/TOTHE APPLICANT ASOWNER CONTRACTOR AND/OR THE AGENT OF IHE CONTRACTOR ITR OWNER TOCONIS ERUCT THE STRUCTURE AS MAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT INCONSIDERATION OE TH E !SSC ANCE OF THISPIRMrr, THCSIGNER FIERLAY AGREES TO COMPLY WITH ALL BUILDINGCODES AND LAND USE REGULATIONS ADOPTED STCARFIPID COUNTY PURSUAMIN AUTHORITY CIV EN IN 30 20.30! CRS AS AMENDED THE SIGNER FURTHER AGREESTHAT TRITE ABOV E5AB) ORDINANCES ARE NOT FULLY APPLIED WITH IN THE LCICATION, ERECTION, CONSTRUCTIONAND USEOE THE ABOVE DESCRIBEDSTRUCTURE, THE PERMIT MAY THEN SE REVOKED HY NOTICE FROM THE COUNTY AND THAT THEN AND THERE R SHAM BECOME NULL AND VOID LSSUANCE OF A PAIM!T BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVIUNT THE BUILDING OFFICIAL FTEOM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR PDR PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR RLC:UTATION OF THIS JURISDICTION REVIEW or THE St/EMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR IIABILITRS BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DECREPANCIES THE RESPONSIBILITY FOR TILESP ITEMS AND IMPLEMENTA11ON DURING CONSTRUCTION IS SPECIFICALLY WITH THE ARCHITECT. DESIGNER, BUILDER ANQOWNER..COM MENIS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INTDAL 4 Plans to be included for a Building Permit, must be on drafting paper at least 18" x 24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations, all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house wrap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. wind shear, wind exposure B, wind load of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. Yes n/a 2. Does the site plan include, when applicable, the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes No Not Necessary For This Project X 3. Are the plans submitted for application construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes X No Not Necessary For This Project 4. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer: Yes No Not Necessary For This Project X 2 5. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes X 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes No Not Necessary For This Project X 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes No Not Necessary For This Project X 8. Do the plans indicate the location and size of ventilation opening for under floor crawl spaces and the clearances required between wood and earth? Yes No Not Necessary For This Project X 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No Not Necessary For This Project X 10. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea lever), floor loads and wind loads? Yes No Not Necessary For This Project X 11. Do the plans include design loads as required for floor loads under the Uniform Building Code Chapter 16 and Tables 16A, 16B and 16C? Yes No Not Necessary For This Project X 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes No Not Necessary For This Project X 13. Is the wind speed and exposure design included in the plan? Yes No Not Necessary For This Project X 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes No Not Necessary For This Project X 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes No Not Necessary For This Project X 16. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes No Not Necessary For This Project X 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certifica tion? Yes No Not Necessary For This Project X 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No Not Necessary For This Project X 19. Does the plan include a window schedule or other verification that egress/ rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes No Not Necessary For This Project X 20. Does the plan include a window schedule or other verification that windows provide natural Light and ventilation for all habitable rooms? Yes No Not Necessary For This Project X 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No Not Necessary For This Project X 22. Do the plans include a complete design for all mechanical systems planned for installation in the building? Yes No Not Necessary For This Project X 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5-A) Yes No Not Necessary For This Project X 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes No Not Necessary For This Project X 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No Not Necessary For This Project X 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes No Not Necessary For This Project X 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes No Not Necessary For This Project X 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes X No 29. Have you designed or had the plan designed while considering building and other construction code requirements? Yes No Not Necessary For This Project X 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes X No 31. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes X No 32. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes X No 33. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes X No 34. Are you aware that the person signing the permit application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project complying with the Uniform Building Code? Yes X No 35. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes X No 36. Are you aware that prior to issuance of a building permit, you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes X No 37. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes X No 38. Are you aware that on the front of the Building Permit Application , you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance of a building permit? You attention in this is appreciated. Yes n/a No I hereby acknowledge that I have read, understand and answered these questions to the st of my abili Signa • Date Phone: (970)285-7330 (Days) 1 azIL q, 2a74 N/A (Evenings) Project Name: Building "G", Willow Park Apartments Project Address: 1230 West Battlement Parkway, Battlement Mesa, (Willow Park Apartments) Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. Project Summary Willow Park Apartments - Building "G" 1230 W. Battlement Parkway Battlement Mesa, Colorado cf This project is the exterior renovation and re -roof of Building "G" of the Willow Park Apartments in Battlement Mesa, Colorado. The Scope of Work for this project includes: cnI 1. The complete removal of the existing roofing material (asphalt composition shingles over roofing felt) and replacement with 30 year "Architectural" (dimensional) shingles over a new No. 30 (30 pound) roofing felt underlayment. New stepped flashing, continuous ridge ventilation and other accessories will also be installed. 2. The complete removal of the existing siding systems including roof gutters and fascia. The building will be wrapped with "Tyvek housewrap" air infiltration barrier. New fascias will be installed and wrapped with a preformed aluminum fascia material. The majority of the exterior will receive new vinyl siding and accessory trim. The stairway/ entry areas and private patio/deck areas will receive new cement composition panel siding. In order to provide proper nailing of the new vinyl siding, the existing guardrails on the private patio/deck areas will be removed and replaced with new framing. The new guardrails will comply with Section 509 of the Uniform Building Code, 1997 Edition. New "smart" (wood composition) trim will be installed as required. All soffits will receive a full venting vinyl soffit system. The Storage Closet doors (located on the individual patios and decks) .Tfrill be replaced also. All new "smart" trim, panel siding and doors will be painted. 1 �ltisizi wil L Qa 91 (LSCice i a5, 3 3. During construction all decking an substrates will be inspected. Da ed areas will repaired or replaced as required. URk Fl iikepr 400 kik tif4+4c t, iUi'v rbutCa 147% Construction o b ildmgs in the Willow Park Apartments was started in 1981. This work was probably accomplished under the provisions of the 1974 or 1977 edition of the Uniform Building Code. In late 1982, with the closing of the oil shale projects, only the exteriors of Buildings A, B, C, and D were completed. The interior of these buildings were finished in 1986. All buildings, except Building D, house twenty apartments and have a basement level (housing four of those apartments). Building D houses sixteen apartments and does not have a basement level. The attached Elevation drawings are from the original Construction Documents. The building is actually three separate buildings (separated by open breeze i`i roof. The areas of each of these three buildings are indicated on theon. GD+w,e ?o G-„r,Ch u 13C �k "tic- it 44 Cwi 1211- eR.0494 To a►,ss µwI ilda.“P1\ Rigal a) 713 C.. h_ 2 N1 Q a w .,. Qba, e n %wA SUBJECT TO NOTED EXCEPTIONS & INSPECTION! GARFIELD COUNTY i ING DEPD 'date 7 -573/By F tELD CO Nc 4 PECTIO?I wiTHOIJT j 1168 P1 &ML ON SUE =Qr AA 8AM AA BA2 AA oOil, egA OVOH AHHVf10 3NOIS Job Addr Owne Contractor Assessor's Parcel No BUI ' . G ERMIT CASO. Oat G5 - ss Setbacks:�FrontFr�Rear _Piac Soils Test Footing Foundation Grout Underground Plumbing Rough Plumbing Framing Insulation Roofing Drywall Gas Piping -r-0-09/9714_, PAA. OiC Address Address Date RH INSPECTIONS NOTES LH 5-I1-cft ne Phone # Zoning Weatherproofing Mechanical Electrical Rough (State) Electr' al Final State) Final • QI(ecklist Completed9 [/ Certificate Occupancy # Date Septic System # Date Final Other (continue on back) INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued &Aft Zoned Area Permit No 81 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and I%IMEDIATELY BECOME NULL AND V t ID. Use Add or Legal Description Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing Foundation Underground Plumbing Insulation Rough Plumbing Drywall Chimney & Vent Electric Final (by State Ins or) Gas Piping Final ey-a3-by.j Electric Rough (By State Inspector) Septic Final Framing (Toinclude Roof in place and Windows and Doors installed). Notes:,- 281 -or' eta ,Qenrak 1..4-e-- (44-,`(To ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WIIETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD Date, 104 By // 111f IF PLA ED OUTSID OVER WITH CLEAR PLASTIC