HomeMy WebLinkAboutApplication- PermitGarfield County
Building, Sanitation,
& Planning Department
108 8`h Street, Suite #201
Glenwood Springs, Co. 81601
Office- 945-8212 Inspection Line- 384-5003
NO.
8879
•
Job Address
I l� (Y1ulJ3 n5 ir• TD -Ea.. Ea
Nature of Work Building Permit 8/79-/5;2- oa-nnl
Use of Building
Owner kAD n_ru ,e'dlri, knooke
Contractor 1/4 ()QJ
Amount of Permit $ Q�VIo . Lpcp
Date 9-191.0-h3
Clerk
GARFIELD COUNTY BUILDING PERMIT APPLICATION
108 8`s Street, Suite 201, Glenwood Springs, CO 81601
Phone: 970-9454212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003
Permit No: Ztal
ParceUSchedule No: oC 1 is OQ
013(
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND(OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT
THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT.
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY CARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT
IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED
STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING
CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION.
THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF
ANY RESPONSIBILITIES OR LIABLMES BY CARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS
AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE
(MENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Gxrfom.003 ///
1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 4
fro 2O(e. co 4) 9-41, 07
cst it- -he o4
Job Address: /Go MI. D/?. 5/LT (0
Subd. / Exemption: M/NEO7f9 F)' fyfC
1 Lot No: / Block No: F/LA/NG a
2
Owner:
by000Y Mr9/0815oN
Address
s4ME
Ph:
176-0233/
Wk Ph:
3
Contractor:
S,5jk1E
Address:
5,9Mr
Ph:
5/9MF
Lic. No.
4
Architect/Engineer:
5 A PE/GJTAL EN6
Address: ON/7 Ay
DR DASA/r
Ph:
7&7-9542
Lic. No.
5
,j&50/5E7
Sq. Ft. of Building:
Sq. Ft. of Lot:
Height:
No. of Floors:
6
Use of Building:
C,9Rpfratr
7
Describe Work:
OPEN - AORIUE 74'RV c,9,P/'ORT
8
Class of Work: la New ❑ Alteration o Remove
❑ Addition o Move
9
10
Garage: o Single
o Double
Carport: $ Single
o Double
o Driveway Permit o On -Site Sewage Disposal o Site Plan
FY/57/H6 //RJUkW/Ol (Septic)
11
Valuation of Work: $
Adjusted Valuations: $
54010
12
Special Conditions:
NOTICE
A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE
ISSUED BY THE STATE OF COLORADO.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR. IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL
PROVISIONS OF LAWS GOVERNING THIS TYPE OF WORK WILL BE
COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE
GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY
TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE
OF CONSTRUCTION.
�� -1
Plan Check Fee:
0(4/
Permit Fee:
lsc. ?S
dPermit
Total Fee: Dated Issued:
204 4 co
OCC Group: Const. Type:
`/ ]
V
Zoning:
Setbacks:
Manu. Home: ISDS No. & Fee:
iwa1�./1. q"' 2S -C) �i ,%��1,./.R�4
:LI DE .� - V'' ey e/1
' APPRO • DATE -' s • 1 • 8
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND(OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT
THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT.
IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER. HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY CARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT
IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED
STRUCTURE, THE PERMIT MAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING
CARRIED ON THEREUNDER WHEN IN VIOLATION OF THS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION.
THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF
ANY RESPONSIBILITIES OR LIABLMES BY CARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS
AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER, AND OWNER. COMMENTS ARE
(MENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Gxrfom.003 ///
1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): 4
fro 2O(e. co 4) 9-41, 07
cst it- -he o4
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector
2. Permanent address assigned by Garfield County Building Department posted where
readily visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-
absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and
refrigerator, all necessary plumbing;
4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running
water, non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on
balconies or decks over 30" high constructed to all 1997 UBC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration
of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE
ITEMS HAVE BEEN COMPLETED.
****CANNOTOCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISE UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy use and the issuance of a
Certificate of Occupancy for the dwelling under building permit#
Signature 1� Date
7-/&-03
1
BpcontO82002
PLAN REVIEW CHECKLIST
Applicant dAgi {csvlp Date ' 2S --C3
Building
✓Engineered Foundation
4. Driveway Permit
.-----StkweirectSitePlan ) sO
Al 14. Septic Permit and Setbacks
•-"---Grade/Topography 30%
-Attach Residential Plan Review List
✓IVtinimum Application Questionnaire
xl,4 Subdivision Plat Notes
J.(4. Fire Department Review
Valuation Determination/Fees
'Red Line Plans/Stamps/Sticker
,.1. &Attach Conditions
✓Application Signed
�lan Reviewer To Sign Application
c—Pir.ce-WSellednleNo. 41935ta>
40# Snowload Letter- Manf. Hms.
GENERAL NOTES:
Planning/Zonin
Property L. - Setbacks
30ftStre•.a Setbacks
Flood P1
Buildi ' g Height
Z
Sign -off
Ro d Impact Fees
A/DRC Approval
ade/Topography 40%
arming Issues
Subdivision Plat Notes
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and
drawn to scale.
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line.
A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar,
anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house -
rap, (which is required), siding or any approved building material.
A window schedule. A door schedule.
A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square
foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds
per square foot, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC.
Is a site plan included that identifies the location of the proposed structure or addition and
distances to the property lines from each corner of the proposed structure(s) prepared by a
licensed surveyor and has the surveyors signature and professional stamp on the drawing?
Properties with slopes of 30% or greater must be shown on the site plan. NOTE: 106.3.1
(7.) Any site plan for the placement of any portion of a structure within 50 ft. of a
property line and not within a previously surveyed building envelope on a subdivision
final plat shall be prepared by a licensed surveyor and have the surveyors signature and
professional stamp on the drawing. Any structure to be built within a building envelope
of a lot shown on a recorded subdivision plat, shall include a copy of the building
envelope as it is shown on the final plat with the proposed structure located within the
envelope. ,
Yes t/
2. Does the site plan also include any other buildings on the property, setback easements and
utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution
if the property you are applying for a building permit on is located on a comer lot. Special
setbacks do apply.
Yes
3. Does the site plan include when applicable the location of the 1.S.D.S. (Individual Sewage
Disposal System) and the distances to the property lines, wells (on subject property and
adjacent properties), streams or water courses?
Yes
2
Y
4. Does the site plan indicate the location and direction of the County or private road accessing
the property?
Yes
5. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the uniform building code or per stamped engineered
design?
Yes
6. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and the clearances required between wood and earth?
Yes
7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist
spaces's and soffits?
Yes pp)
8. Do the plans include design loads as required by Garfield County for roof snow loads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and yd loads?
Yes
9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construction?�
Yes
10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafters or joists or trusses?
Yes
11. Does the building section drawing or other detail include the method ofpositive connection
of all columns and beams?
Yes
12. Does the plan indicate the height of the building or proposed addition from the highest point
of the building or addition measured at mid span between the ridge and the eave down to
existing (updisturbed) grade contours?
Yes
13. Does the plan include any stove or zero clearance fireplace planned for installation including
make and f del and Colorado Phase II certifications or phase II EPA certification?
Yes No
3
Y
14. Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the Uniform Building ode Chapter 37?
Yes No
15. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping rooms and/or basements comply with the requirements of the Uniform
Building Code?
Yes No ✓
16. Does the plan include a window schedule or other verification that windows provide natural
light and ventilation for all habitable rooms?
Yes No V
17. Do the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as
a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify safety glazing for these,areas?
Yes No
18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan?
Yes No
19. Do you understand that if you are building on a parcel of land created by the exemption
process or the subdivision process, are building plans in compliance with all plat notes and/or
covenants?
Yes t/ No
20. Do you understand that if you belong to a homeowners association, it is your responsibility
to obtain written permission from the association, if required by that association, prior to
submitting an application for a building permit? If you do not have written permission from
the association, do you understand that the plan check fee will not be refunded should the
architecture committee deny or reject your building plans?
Yes J No {pi UE APP,poVAL-
21. Will this be the only residential structure on the parcel?
Yes No If no -Explain: C4 RPOE r
22. Have two (2) complete sets of construction drawings been submitted with the application?
Yes
23. Do you understand that the minimum dimensions a home can be on a lot is 20ft.wide and
20ft. long?�
Yes t/ No
v
24. Have you designed or had this plan designed while considering building and other
construction de requirements?
Yes No
25. Do your plans comply with all zoning rules and regulations in the County related to your
properties zone d%'strict?
Yes ✓ No
26. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes </ No
27. Do you understand that approval for design and/or construction changes are required prior to
the application of these changes?
Yes ✓ No
28. Do you understand that the Building Department will collect a "Plan Review" fee from you
at the time of application submittal and that you will be required to pay the "Permit Fee" as
well as any "Road Impact" or "Septic System" fees required, at the time you pick up your
building p it?
Yes No
29. Are you aware that twenty-four (24) hour notice is required for all inspections?
Inspections will be made from Battlement Mesa to West Glenwood in the mornings and
from Glenwood Springs to Carbondale in the afternoons. All inspections must be
called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for
inspections will delay your inspection one (1) day. Inspections are to be called in to
384-5003.
Yes t/ No
30. Are you aware that requesting inspections on work that is not ready or not accessible will
result in a S47 0 re-inpsection fee?
Yes 1/ No
31. Are you aware that you are required to call for all inspections required under the Uniform
Building Code including approval on a final inspection prior to receiving a Certificate of
Occupancy ar;d occupancy of the building?
Yes No
32. Are you aware that the Permit Application must be signed by the Owner or a written
authority be given for an Agent and that the party responsible for the project must comply
with the Unifo Building Code?
Yes V No
5
33. Are you aware that prior to submittal issuance of a building permit application you are
required to show proof of a driveway access permit or obtain a statement from the Garfield
County Road & Bridge Department stating one is not necessary? You can contact the Road
& Bridge Department at 625-8601.
Yes PA, No
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time of applicable inspection.
Yes ALA, No
35. Are you aware, that on the front of the Building Permit Application you will need to fill in
the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal
of a building permit application? Your attention in this is appreciated.
Yes ✓ No
I hereby acknowledge that I have read, understand and answered these questions to the
best of my ability.
9- /0-03
Signature o wnDate
Phone: 77 6 -o? 531 (days); (evenings)
Project Name:
Hgleie/soN - c4 ;
Project Address: / 6 O M /NFOTA vie
Notes:
SILT
CO
»i65 2
If you have answered "No" on any of the questions, you may be required to provide this information
at the request of the Building Official prior to beginning the plan review process. Delays in issuing
the permit are to be expected. Work may not proceed without the issuance of a permit. If it is
determined by the Building Official that additional information is necessary to review the application
and plans to determine minimum compliance with the adopted codes, the application may be placed
behind more recent applications for building permits in the review process and not reviewed until
required information has been provided and the application rotates again to first position for review,
delay in issuance of the permit or delay in proceeding with construction.
bpminreq
04/2003
6
0
IS
lgoio
co -$-10
L__
•
r
d
\ (‘),
co
vAW
is
cENrSC of
wAt6R"Z
NA 0
0 0 Aty
tr-, . 0 i 4
._..
)it N -o i
o oa�C d° 01
-' x', 714 n ti
Is vii•razci-
,( ai plig
a
k
.
"1
,.^. :,`
• w� -y
'
'�^ p �+'
•v a
ri G 4 're_ (n
ykJ.' P5s
-PA
e'
0 St
J`VVV\..
GENERAL NOTES
CAR PORT
LOT -1 MINEOTA ESTATES
SEPTEMBER 4, 2003
A. DESIGN LIVE LOADS
1. SNOW 40 osf
2. WIND: BASIC WIND SPEED 80 mph
EXPOSURE �•
3. SEISMIC ZONE
B. DFSIGN CODES
1. UNIFORM BUILDING CODE (1997)
2. ACI BUILDING CODE (ACI 318-95)
3. AITC TIMBER CONSTRUCTION MANUAL (4th EDITION)
C. FOUNDATION
BUILDING FOUNDATION SYSTEM HAS BEEN DESIGNED USING AN ASSUMED MAXIMUM
ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. FOOTINGS SHALL BE PLACED ON
UNDISTURBED SOIL. STRUCTURE IS DETACHED FROM RESIDENCE, THEREFORE NO FROST COVER
IS DIRECTED. SOILS ARE ASSUMED TO BE UNIFORM, NON -EXPANSIVE, AND NON -COMPRESSIVE.
THE OWNER SHALL RETAIN A SOILS ENGINEER TO INSPECT THE BEARING SOILS EXPOSED DURING
EXCAVATION TO VERIFY ASSUMPTIONS AND TO SUBMIT A WRITTEN REPORT. NO FOOTINGS
SHALL BE POURED UNTIL A VERBAL SUMMARY HAS BEEN GIVEN TO THE STRUCTURAL ENGINEER
BY THE SOILS ENGINEER. THE SOILS ENGINEER SHALL ALSO BE CONSULTED BY THE OWNER IN
REGARDS TO POSSIBLE FOUNDATION DRAINAGE REQUIREMENTS, AND ANY ADDITIONAL
CONSTRUCTION REQUIREMENTS AFFECTED BY SOILS.
D. CONCRETF
CONCRETE HAS BEEN DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE
AMERICAN CONCRETE INSTITUTE BUILDING CODE (ACI 318-95). ALL SLABS ON GRADE AND
STRUCTURAL SLABS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI IN 28
DAYS. ALL OTHER CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI
IN 28 DAYS. ALL SLABS ON GRADE SHALL HAVE CONTROL JOINTS (KEYED OR SAW CUT) AT A
MAXIMUM 15'-0" ON CENTER EACH WAY UNLESS OTHERWISE SHOWN ON PLAN. REINFORCING
BARS SHALL BE ASTM A615 - GRADE 60. LAP SPLICES, WHERE PERMITTED, SHALL BE A
MINIMUM OF 44 BAR DIAMETERS. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT
REINFORCING AT POSRIONS SHOWN ON THE PLANS. WELDED WIRE FABRIC SHALL CONFORM TO
ASTM A185. LAP WIRE FABRIC REINFORCEMENT ONE FULL MESH PLUS 2" AT SIDES AND ENDS
AND WIRE TOGETHER. ANCHOR BOLTS FOR BEAM AND COLUMN BEARING PLATES SHALL
CONFORM TO ASTM A307 AND BE PLACED WITH SETTING TEMPLATES.
E. STRUCTURAL WOOD FRAMING
ALL WOOD FOR STRUCTURAL FRAMING SHALL BE KILN DRIED DOUGLAS FIR/LARCH GRADED AS
PER LATEST EDITION "NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION" BY THE
NATIONAL FOREST & PAPER ASSOCIATION AND WWPA.
STRI ICTI IRAI JOISTS (> 7X61 NO. 2 OR BETTER,
Fb-900 PSI (x1.15 REP)(xCF) Fv - 95 PSI E - 1600000 PSI
I IR,HT FRAMINrtSTI ITIS 2X4(STUD OR BETTER)
Fb - 700 PSI (x1.15 REP) Fcperp - 625 P51 Fcpar = 850 P51
FRAMING STUDS 2X6 (NO. 2 OR BETTFR)
Fb = 900 PSI (x1.15 REP) Fcperp = 625 PSI Fcpar = 1350 P51
PRESSURE TREATED LUMBER (HFM-FIR NO. 2 OR BEFFR)
Fb - 850 PSI (x1.15 REP) Fv - 75 PSI E - 1300000 PSI
SIZES SHOWN FOR STRUCTURAL WOOD FRAMING ARE NOMINAL SIZES. PROVIDE SOLID BLOCKING
BETWEEN ALL JOISTS AND RAFTERS AT SUPPORTS AND MINIMUM 1 X 4 CROSS -BRIDGING AT
NOT MORE THAN 8'-0" O.C. BETWEEN SUPPORTS EXCEPT AS OTHERWISE NOTED. PROVIDE
BRIDGING AT NOT MORE THAN 6'-0" O.C. FOR STUD WALLS NOT COVERED BY SHEATHING OR
WALL COVERINGS MEETING UBC MINIMUM REQUIREMENTS PER UBC SECTION 2320-11.
CONNECTORS SHOWN ON THE PLANS ARE MANUFACTURED BY THE SIMPSON COMPANY.
CONNECTORS BY OTHER MANUFACTURERS SHALL BE DEEMED AS EQUIVALENT IF THEIR RATED
CAPACITY 15 EQUAL TO OR GREATER THAN THAT OF THE CONNECTOR SPECIFIED. FOLLOW
MANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS. ALL NAILING NOT NOTED SHALL
BE ACCORDING TO TABLE 23-11-B-1 OF THE UNIFORM BUILDING CODE. PROVIDE SIMPSON H2.5
TIE AT EACH ROOF RAFTER BEARING CONDITION, UNLESS NOTED OTHERWISE.
PLYW00Q
FOR ROOFS, FLOORS, AND SHEAR WALL SHEATHING SHALL BE APA GRADE TRADEMARKED CDX
WITH EXTERIOR GLUE. LAY UP PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS AND
STAGGER JOINTS. PLYWOOD OVER DECKING TO BE LAYED PERPENDICULAR TO DECKING.
STAGGER JOINTS TO AVOID PLYWOOD EDGE ALONG PLANK EDGE. ALL NAILING COMMON NAILS;
RING SHANKED FOR ROOF AND FLOOR SHEATHING. REFER TO TABLE BELOW FOR USE
REQUIREMENTS:
USE THICKNESS SPAN/INDEX EDGE INTER
RATIO NAILING NAILING
FLAT ROOF 3/4" 48124 8d@6"OC 8d@12"OC
SLOPED ROOF 5/8" 32/16 8d@6"OC 8d@12"OC
SHEAR WALL 1/2" PLYW'D 24/0 8d@4"0C 8d@1 2"OC
1/2" PARTICLE BOARD 24/0 10d@3"OC 10d@12"0C
ALL EDGES OF SHEAR WALL SHEATHING SHALL BE BLOCKED. PARTICLE BOARD SHEATHING MAY
BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF ARCHITECT AND ENGINEER.
PARTICLE BOARD SHEATHING SHALL COMPLY NOT LESS THAN TYPE M EXTERIOR GLUE AND
SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES.
CONTACT STRUCTURAL ENGINEER AND ARCHITECT FOR SUBSTITUTION APPROVAL PRIOR TO
CONSTRUCTION.
u
PO�RNuu,�
':n'
s i ` 2577'
%/4,SSitZtLrct�� y.
"� mna'Aj inJv.°
F. ALL EXISTING CONDITIONS MUST BE VERIFIED BY THE BUILDER IN THE FIELD. UNKNOWN AND
VARIED CONDITIONS MAY BE FOUND. NOTIFY THE ENGINEER OF ANY STRUCTURAL CONDITIONS
FOUND TO VARY FROM THAT INDICATED. DESIGN REVISIONS MAY BE REQUIRED, AND ARE
EXPECTED AS A PROCESS OF REMODEL WORK.
G. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE VERIFIED AGAINST THE
ARCHITECTURAL AND DISCREPANCIES SHALL BE , BROUGHT TO THE ATTENTION OF THE
ARCHITECT.
H. THE ARCHITECT MUST AUTHORIZE ALL SUBSTITUTIONS. SUCH AUTHORIZATION DOES NOT
RELIEVE THE CONTRACTOR FROM CONFORMANCE WITH THE DRAWINGS AND SPECIFICATIONS.
I. COORDINATE ALL OPENINGS THROUGH FLOORS, WALLS, AND ROOFS WITH THE MECHANICAL
AND ELECTRICAL CONTRACTORS.
J. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION.
LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT.
K. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR
SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING
CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING,
SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE
SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS NOR
WILL THE STRUCTURAL ENGINEER BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS,
TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS
AND THE PROGRAMS INCIDENT THERETO.
03061
• SITr Pi- /9N Y, V
700: 00
I go'
GARAGE
DRY LP
L.
NEW c4Pl°lRT L ocArloAl
wEs— SIDE of G'A2A6
oo'
PERCOLATION TEST HOLES o- E,q/LEV INS,
y'nEEP, 8-17" DIA. ANO
2o'APART
00 WELL I91f55T12/NSi?
COMMUNITY WATiP LINE
OEPTN- 6'
N.
'3-
SCALE: 3":---/001
0
W)LL/AM F HARRISoN
MINEoTA ESTATES
Lor"I - FILING 2
0160 MINEOTR OP.
KS
Noi"'1
Assessor's Parcel NoQr-pa- K52-tQ-ncj
Date (51` p36 -b,
BULLRING PERMIT CABDh� L- I •
Job Add ss 11.0C.) Y-��
Owner J Address 1 Aka
Phone #$,b a3`
Contractolfn y e Address Phone #
Zoning
Setbacks: Front
Rear
Soils Test
Footing (t7 - 1-O''jt
Foundation
Grout
Underground Plumbing
Rough Plumbing
Framing 1-1-1A—P10-
Insulation
Roofing
Drywall
Gas Piping
RH
INSPECTIONS
NOTES
LH
Weatherproofing
Mechanical
Electrical Rough (State) _ /pf
Electri al Fin I (State) /(/
Final - Checklist Completed?
Certificate Occupancy #
Date
Septic System #
Date
Final
Other
(continue on back)
INSPELITI WILL NOT BE MADE UNLESS
THIICARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
Date Issued
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
/ .0.3.oned Area
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL ANI) VOID.
Permit No .4.Q..7.
Use
Add Legal Description r .
Owner
Setbacks Front
Side
Contractor tr d
Side
Rear
This Card Most Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing 10 -a -O' ��
Foundation
Underground Plumbing
Insulation
Rough Plumbing
Drywall
Chimney & Vent
Electric Final (by State Inspector) "tin
Gas Piping
Final G_ /_Oy(--
Electric Rough (By State Inspector)
Septic Final
Framing Cr_/ _0 t`9M
(To include Roof in place and Windows
and Doors installed).
Notes:
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
Phone 384-5003
THIS PERMIT IS NOT TRANSFERABLE
109 8th Street County Courthouse Glenwood Springs, Colorado.
DO NOT DES Y THIS CARD
APP - OVED
Date~
COVER WITH CLEAR PLASTIC