Loading...
HomeMy WebLinkAboutApplication- PermitJob Address Garfield County Building, Sanitation, & Planning Department 108 81" Street, Suite #201 Glenwood Springs, Co. 81601 Office- 945-8212 Inspection Line- 384-5003 NO. 8872 5115 e Roe G /6 S� Nature of Work Building Permit �� Use of Building J /0/ `'� A e -`i Owner \'xj ViTs / Contractor O 60 Amount of Permit $ 3 5 7i Date Permit No: GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8i6 Street, Suite 201, Glenwood Springs, CO 81601 (D��r((jJjJ P ne: 970-945-8212/ Fax: 970-384-3470/Inspection Line: 970-384-5003 Parcel/Schedule No: a) fl - ;SY - 0QYi67c { AGREEMENT PERMISSION 1S HEREBY GRANTED TO HE APILICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT VIAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A FERMI BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF TNS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER. AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Gnfom.003 1 HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): saga. 8(a�/o3 icjay.4o Job Address E W. 333 Read s,�II- Co ii4sa 1 Block No: Subd. / Exemption: 1 Lot No: /� 0r ekard Let ylo (jar, /j 2 Owner tJ 2-A.rr.es P. /3 Are '�yy Address s/` )1 ITW 6 57/*co P/�S-a. PnA4�-krs V7G-o'76S 6I --95/023 3 Contractor:1 // //Jf Ow4U' /LI+.i ceite- Address: Pb: Lic. No. 4 Architect/Engineer: $A.. -int Address: Ph: Lic. No. 5 Sq. Ft. of Building: 3,15-0 Sq. Ft. � f re i Height: d �ol No. of floors: 6 //) �//�� Use of Building: � '!y keSidemA �L (cai)eAa (JCl(,ek 9.1319_ ctwt 7 T Describe Work: 8 Class of Work: )t!‹. New ❑ Alteration ❑ Remove o Addition o Move 9 10 Garage: o Single f.0(nt o Double Carport: u Single iLoht o Double o DrivewayJ P rmit On -Site Sewage Disposal kSite Plan �LY7i (Septic) 11 Valuation of Work: $ D( ^ © Q.' am +;7 Q Adjust Va t ns: t3 Z 29 -T �` 12 Special Conditions: NOTICE A SEPARATE ELECTRICAL PERMIT 1S REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BiCOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 13 NOT COMMENCED WITHIN 180 DAYS, OR, IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GO VERNINC THIS TYPE OF WORK WILL BE COMPLETED WITHIN WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR e AL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE O ONSTRUCTION. 1r , S, _ o Plan Check Fee: 136.5.174 7 Permit Fee: ZO8C.7S' Total Fee: DatedPermitIssued: 1 3 5' 1 , 4 7 OCC Group:( Const. Type: Zoning: Setbacks: Manu. Home: ISDS No. & Fee: s rte{ 3 .� BDG DEPT. r G. APPROV /DATE PP: % PT. eV._ DATE { AGREEMENT PERMISSION 1S HEREBY GRANTED TO HE APILICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPILED WITH IN THE LCOATION, ERECTION, CONSTRUCTION, AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT VIAY BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A FERMI BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF TNS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABLITIES BY GARFIEID COUNTY FOR ERRORS, OMISSIONS OR DISCREPENCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICIALLY WITH THE ARTICTECT, DESIGNER, BUILDER. AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Gnfom.003 1 HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL): saga. 8(a�/o3 icjay.4o The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non- absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOTOCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISE UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Cert;ficate of Occupancy for the dwelling under building permit 2 % a -- p. 8 P.8 Sign re Date BpcontO82002 V -aS-©3 VALUATION/FEE DETERMINATION Applicant Subdivision Gv {�CvS c log yc-/ Address Cil 23 3 S.' i f Lot/Block to -I- U b Date Gq / (6r43 Contractor 0 tone r Finished (Livable Area): Main 2,ohp Upper ice / 0 Lower Other Total Square Feet Valuation Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation Valuation Decks/Patios: Covered Valuation Open Valuation sk 395.0 g = 244M SO 1/38 x ?Y. 281S-12 Total Valuation 211 «2 w Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony. steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house - rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. NOTE: 106.3.1 (7.) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes K 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes X 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent Yproperties), streams or water courses? Yes /\ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes X 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes x 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces's and soffits? Yes >C 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (yttdisturbed) grade contours? Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Pyase II certifications or phase II EPA certification? Yes No 3 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes X No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes Y No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and speci safety glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes x No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes x No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes \l No 21. Yes i( No Ifno-Explain: Will this be the only residential structure on the parcel? 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimensions a home can be on a lot is 20ft.wide and 20f1. long? Yes No 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes x No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes X No 27. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building pe it? Yes ?S No 29. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5OQ 3. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a 847.00 re-inpsection fee? Yes No 31. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occup cy and occupancy of the building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the U rm Building Code? Yes No 2 33. Are you aware that prior to submittal issuance of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Brid e D artment at 625-8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at t e of applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a buil ing ermit application? Your attention in this is appreciated. Yes No I hereby acknowledge that 1 have read, understand and answered these questions to the best of my ability. P. lam- V -?5--03 Siature of Owner Rno- 61? --41403 o -r Phone: COO- ni9-0 )&C (days); Project Name: Project Address: Notes: Date 4')o 1 '?b -0?6S (evenings) ll ec,e 4*t.Ge_ Tt1 cR. a33 , S;/t, co W6s e2 If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 04/2003 08/25/2003 20:02 6258627 ROAD AND BRIDGE PAGE 01 Garfield County Garfield County Road and Bridge Department August 25, 2003 James Bo e 876-0765 Lot 46 of Antlers Subdivision Dar Mr. Bate, You do not need a driveway permit frost Garfield County Read and Badge Department. The Antlers Subdivision does not enter onto a county Road. If you have any questions of problems, please feel fret to aonnct me. Sincerely, Kraig Kuberry District 2 Foreman Garfield County Road and Bridge Department 902 Taugheahs.► Shd'. Seise 305 a CO eau ?bow !l►4SN Pas: 910425-607 az2M44O io G7 Cd G) J C 0 0w CO I -h 1 0 F r 'O£ co a fD //S.0 rt H- 1-1 01 0 7 G a i a co co cn n UJ rt w 0 r O ri G N rt fD a H- m rt rt b '< U w Cn rt n fD r• O G o N iO O O rt I� w a 0 Fano HEawaw a3SS2EIS > >m I-aW n r m w yrz 0 fn cC7 hi m > E m a bCIz w 0 0 m 0 CD a 11 11 H- rt J 61 r' G O N lO O t /n O tO w I-. O • 11 fD I-4 0 W r' a • • aw O Lc) co £ m H- 0 w n raw 7 O rt fD < \77 r• H. --.m MG 0- 1-, 0c0 • II Ur r- 0 I-- ao O C C r; rr m w H. a rt G r- G fn y ›i CO 0 0 x n r x N Cil r3 r LT C m w ✓ O 1 N rr ✓ 0 m 0 • II II 0 O. W N N r' ›i CO w r- 11 131 0tO0 N � o n cora Fa as CD '0 o\O o xTO'cnhi O n O o m rl- C7 G G til G 2 O a 0 - CI Ur fn (0 t t r e CD CC n co N F 171 t - N C7 C7 W 01 0 OJ r m m O 0 0 0 CI O r Hi rA n rt N y r- m m 11 11 11 11 H O 0 0 0 • rt rt • • z F -1 - I -1-N W /n O 0 0 JW(no1 x 2 cn w m W H -J r- rh II G r- n r- • O 0 7 0 0 0 • r'0)fD (0 m o r O 7[n 7 ht Ow Ui (D fD O J (n CO o Op 11 Fi w ut 0•Z= buTJeag uTW ur 0-Z= buTieag uTW H 0 r rrrm w 11 II [1 r LA) rt � N Cn 0 U1 r- (0 J N 0 r r 0 0 r.r.r. QtT0 fn N fn 1_ / 3 - 2x10 HEM -FIR #2 J LL= 720 plf 1 0 0 / H 0 r rrrm w II a II 0 W 0 N rt (nOcnr- p N O • • • 10- 01 Co0) Cl/ N m PLAN REVIEW CHECKLIST Applicant Date 9-9-a% Building pJ4 Engineered Foundation Driveway Permit ✓urveyed Site Plan > CO ptic Permit and Setbacks -trade/Topography 30% Attach Residential Plan Review List �--lMinimum Application Questionnaire Subdivision Plat Notes / 1 Q. Fire Department Review VValuation Determination/Fees d Line Plans/Stamps/Sticker Attach Conditions c/ Application Signed Plan Reviewer To Sign Application Parcel/Schedule No. 40# Snowload Letter- Manf. Hms GENERAL NOTES: Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain Building Height Zoning Sign -off Road Impact Fees HOA/DRC Approval Grade/Topography 40% Planning Issues Subdivision Plat Notes ./St' c ? GARFIELD COUNTY BUIL 109 8t Glenwood Ph INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY © C% / 8/� (� Owner's Name a ret Savhe3 r Present Address +6�/ 710 Si /��ph�ne/' iS '7o26,5- 59% OW gi65) tre pri e( 3 ND SANITATION DEPARTMENT Suite 303 s, Colorado 81601 3) 945-8212 Permit N= 3853 Assessor's Parcel No. aiaei-35V-00 - & This does not constitute a building or use permit • System Location Legal Description of Assessor's Parcel No. SYSTEM DESIGN !off V'& netts a/ecla 'rte 5 [/ Septic Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Number - of Bedrooms (or other) L/ T ,/,//� 'rcr. A/-/9717 Required Absorption Area - See Attached / Special Setback Requirements 703 a1 _97 s_< / 473 rg 0P,irr_7 Date / it' /l/ — O 3 Inspector -------7-27,,., P�j FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity /SO0 Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface f//7 Absorption Area Absorption Area Type and/or Manufacturer or Trade Name^ -hr/ /CT r Adequate compliance with County and State regulations/requirements rijeg, Other / r, Date 4 - (;• L Inspector $ / RETAIN WITH RECEIPT RECORDS AT CTION SITE CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirel4fent of the permit and cause for both legal action and revocation of the permit. 3. Any person -Who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty 011ense ($500.00 Iine — 6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT Monday. SeptImbar 22. 2003 2 28 PM To Alin Teresa From. James Bare. 970-676-0765 Page 1 of 1 The art 2esiknet Alap /atqb-eAtirkerdmel T,rniJ'» S seal. 1/4T at 1 \ irr.s. CS, 333 (;i1- Mcsa ) faislF-- aM,t -Q1 U i rar,finin S : head Wes+ f o»L S; /f nn. Alain SI rNw0.) © — * ti -A Nonik pry 1t-s"S , feIGM/ %r Cut a;0 - Wm* C.k, ?33 Cc -if Atka ki.) O— precede- 403atie.l.2 mijet , /i. e. ,t4r-4. d -n iloor Pt04.P (00 0atrt F.—I4 '�'r�.--f egji 7� r 1 (Aof db g 15 Alt ptsk O t;: sL Sab C ` `O ;44.1 ck,vaisk r 1\ COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 201 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at Jr c 2- 33 Permit No. 97?i I have this day inspected this structure and these premises and found the following corrections needed: 1r v -64,1 Aker on- de lta You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. 3-e -ai 20 Building Inspector Date Phone (970) 945-8212 1 INSPECTION WILL NOT BE MADE UNLESS • -THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT R IELD COUNTY, COLORADO % Date Issuedned Area 71:12%9 Permit No... AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use Add D cription Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing 9a -a3 ,&x Foundation �/ 1/1A--7 .til Underground Plumbing X0_7-03 Insulation 3 h__/ 2.,..0,/ Rough Plumbing 3- Do Ss, Drywall .4. 4'-b4 Chimney & Vent 3 _q Qy Electric Final (by State Ina tor)L_g �' Gas Piping 3 2 b `f Final 4— j_p y. Electric Rough (By State Inspector)}g2,r) Septic Final /— 2-0 tf 7 -74/ - Framing 3 -9-p (To include Roof in place and'Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. Phone 384-5003 AP D THIS PERMIT IS NOT TRANSFERABLE 109 8th Street County Courthouse Glenwood Springs, Colorado. V DDI b'7 I 'retail* IF PLACE i 0 SIDE - COVER WITH CLEAR PLASTIC 9