Loading...
HomeMy WebLinkAboutApplication- PermitGARFiELD. COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 Stix. Street, Suite 303 Glenwood Springs, C0,81601070) 1(470) 946-8212 Job Address ,r ` Nature of Work Building P. Wait * Use of Building j_4 ' ' J de1-4., .LL !J r Contractor 116151116117# j .1 0-- (7V/(1.--,543 — je'- ®/Li , N0.8843 Amount of PermitSr GAIWIILD COUNTY BIJILMNG FE .NIX' ' APPLICATION ` GARFkELD COUNTY (GLENWOODSPJU GS), COLOE DQ INSPECTION LINE: (970)384 5003 PARCELISC}JEIIU,B NO. r2 !13/3 TELEPHONE:.. (970) 945-8212 PERE' NO. C �° JOB ADDRESS: 0213 Creeksi de Court ' o sic 1 LOT NO. 14 . BLOCK NO. , . SUBDIVISION MPT'ION Mitch 11 Creek SUbd. `�a."" 2 - °" "Gregg/Marilee Rippy ''n°" 0213.•Creeksi.de Ct, GS' n5--7 31 G•VXM 3 cram-wmaDM Neuman Const _Co . • ADDS PO Box 231.7, GS cs _ ... SES a- . P '-7502-�raBEST 295( 4 _ ALLCIA EOTALI 7107. Ir.,La./a A4aRE59, PfF .. 3iCNp: 5 S: °FHeimard n Q.FSn/a 3q. E<. OFY ar _ =OAT NO, 0? MOMS 6 TSEOPBVfLD" '• s/f residential . • { extend existing decks . • 8 .C1Asa oFwOR36 woe! xaµD➢mON oAmwomw mmg claw Q 9 7 oARAag ogztq� p4U aBL8 CARPORT: ooDICL6 °mince ° f 10 . . a ORNEWAY PEWIT .. CON ATE SEWAGO DISPOSAL.; (9211-1C) METE PLAN •fIpLVA?YUN6E,1YORK: S1 , 000 "'F/ _ ii.OX FEO WSA TIONS f �. ^ NOTICE A SEPARATE ELECTRICAL mama IS REQUIRED AND MUST SE. ISSUED BY TEE STATE OF COLORADO THIS PERMLT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT CONR•IENCED WITHIN ISE DAYS, ORZFCONSTRUCTION OK WORIC IS SUSPEIJAEP OR ABANDONED FOR A PERIOD OF I30 DAYS AT ANY TIS$ AFTERWORKIS COMMENCED. .. THEREBY .CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW -Gig SAME TO BE TRUE ANIS CORRECT, ALL PROVISIONS OF LAWS GOVERNING THIS TYPE OF WOIU( WILL BE COMPLIED WITH WHETHEP SPECIFIED ' HEREIN OR NOT. THE --.GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE4)...'l IWTIQIUTY TO VIOLATE OR CANCEL THE.PROVISIONS OF ANY OMR STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE .. PERFORMANCE OF - PLANCFftCKFEB: 122121 PERMIT FEE: Sig 3.2,5' TOTAL FEE: DATE PERMIT ISSUED: 48 3 . -i • OCC: CROUP: CONST: TYPE: 1 3 �[ ZONING: • SETBACKS: CONSTRUCTION. , Aa. �/ S"•. '£a �/ •,�-- Tar ii i6' oAI ,i1( A�. 7 i• /'• . TOME: • . ISEIS NO FEE: . .. - . • BulidiagDa.t. ', . QV:VDate - `laaaulg R •. • r _Qvr II, - d .. AC>RE IEbFY PERMISSION IS HEREBY GRANTED 10 THE APPLICANT AS OWNER, CONTRACTOR AND/ORTBE AGENT OF u iL CONTRACTOR OR OWNERTO CONSTRUCT TUE STRUCTURE . DETAILED ONPLAS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED EY 1.W, HUMUINGDEPARTMENr. TNI CONSIDERATION OF TH8 3SSUANUE OF THIS viET., THE SIGNER HEREBY AGREES TO COMPLY WITHAM BUILDINQ CODES AND LAM) -ISE REGULATIONS ADOPTED I GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30,23.201 CRS AS AMENDED. THE SIGNER FURTHERAGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULI COMPLIED WITH TN TUE LOCATION, EREUIION, CONSTRUCTION AND USE OF TBE ABOVE' DESCRIBED STRUCTURE, THE PER 1E MAY THEN BE REVOKED BY NOTICE FRC TIM COUNTY AND. THAT THEN AND TDERRTTSHALL BECOME NUIL., AND VOIR. TVE ISSUANCE OF A prima BASED UPON PLANS, R PEcrETCATLONS AND OTHER DATA SHALL NOT EREVENTTBE BUILDING OFFICIAL FROM TBERRAFTER REQUIRE,* TI CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR PRO PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN VVOLATIONOFTBIS CODE OR ANY OTHER ORDINANCE OR REGULA'T'ION OF THIS JURISDICTION. TI3E REVIEW OF £Iih SUBLM1'ITED PUNS AND - SPECIFICATIONS AND 3NSPECFIONS CONDUCTED TAFdRR•DOES NOT C©NSTTT TE AN ACCi.PIAN.CE OF Al RESPONSIBILFIiiES OR I.JABIL'CTIES EY GARFIELD. COUNTY FOR ERRORS, ONHSSIONS OR. DISGII`i7..8AN£lE5.. THE RESPoNSIBFi. n' TOR, THE ITEMS AND li SPLE iENI`ATB DURING CONSTRUCTION RESTS SPECIFICALLY WTI` -1 T , ARCHSFECF, DESIGNER, B JA'.DER AND OWNER. CaIre4E TFS ARE DITENDED TOB CONS VATIVE• AND RsI SUPPO OTTHE OWNERS INTEREST./q Gazfoaaoo3 IHEREBY ACKNOWLEDGE THAT 'HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE. (moNITIAL) /I `� b,03,\ tsL -5 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from theyColorado State Electrical Inspector; 2. Permanent address assigned;by Garfield County Building Department posted where readily - visible from access road; 3. Afinished roof, a lockable house, complete exterior siding, exterior doors and windows - installed, a complete kitchen with cabinets, a sink with hot & cold runningewater, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator,,all necessary plumbing; 4. A complete bathroom, Witli washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and wallfinished and a privacy door; • 5. Ali steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to 'where water will detour away from the building; .-7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of - extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and;,a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE - ABOVE ITEMS HAVE BEEN COMPLETED: • ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupant use and the issuanceof a Certif eatejof Occupancy for the dwelling under building permit #`750 t'4' Signature - BpcontO82002 Date Applicant g Okr PLAN REVIEW CHECKLIST Date 810,03 Ruiidiug Ai 4 Engineered Foundation /t 4. Driveway Permit i4urveyed Site Plan /4,71 .,Septic Permit and Setbacks AL Grade/Topography 30% Attach Residential Plan Review List ✓4CirnumApplication Questionnaire /4,1,- Subdivision Plat Notes kit 4 . FireaDepartment Review ✓ iTaluation Determination/Fees Red Line Plans/Stamps/Sticker Tid Attach Conditions -Application Signed „..1‘n Reviewer To Sign. Application ✓4arcel/Schedule No. ith 40# Snowload Letter- Man£ Hms. GENERAL NOTES: Planning/Zoning Property Line Setbacks 30ft Stream Setbacks Flood Plain. Building Height Zoning Sign -off • Road Impact Fees HOA/DRC Approval Grade/Topography 40% Planning Issues Subdivision Plat Notes i Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, handrails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house - rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,00Q feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. NOTE: 106.3.1 (7.) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it)s shown on the final plat with the proposed structure located within the envelope. Yes i 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property You are applying for a building permit on is located on a corner lot. Special setbacks doply. Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal Syste) and the distances to the property lines, wells (on subject property and adjacent prope i -s) streams or water courses? Yes r► 7 4. Does the site plan indicate the location and direction of the County or private road accessing the property).? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes it` 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and t e learances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces's anoffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? �� 3 ©'fie • Yes /Y/k LZ' t�-- 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafter or joists or trusses? Yes Ai it 11. Does the building section drawing or other detail include the method ofpositive connection of all columns a d beams? Yes 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (und'sturbed) grade contours? Yes hl 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase certifications or phase 1,I EPA certification? Yes No 3 i) 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Bui1din Code Chapter 37? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable ,gams? Yes No ✓ 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for theses? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No/1//ff 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are bi)ildingplans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? Ifyou do not have written permission from the association, do you understand that tl1.e plan check fee will not be refunded should the architectural ommittee deny or rej egg i . building plans? Yes V No 21. Will this beth only residential structur��cthe parcel? Yes No ;�� If no -Explain: 22. Have two (2�� complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum dimensions a home can be on a lot is 20ft.wide and 20ft. long? Yes No 4 24. Have you designed or had this plan designed while considering building and other constructioJ code requirements? Yes No 25. Do your plans comply with all zoning rules and regulations in the County related to your properties zone istrict? Yes No 26. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes 1/ No 27. Do you understand that approval for design and/or construction changes are required prior to the applicatiyf these changes? Yes No 28. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building perm' Yes tt✓✓ No 29. Are you aware that twenty-four (24)- hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes No 30. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $47.00 re-inpsection fee? Yes No 31. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy an •occupancy of the building? Yes No 32. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the UnifBuilding Code? Yes t/ No 5 33. Are you aware that prior to submittal issuance of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time, applicable inspection. Yes No 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. A#A. Yes No I hereby acknowledge that I have read, understand and answered these questions to the bet of my ability. L6/t1 -r, ' '7 2-I.-- 9 3 Signature of wrier . Date Phone: _ (days); (evenings) Project Name: X l 19 P'1 aCY-5 Project Address: Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 04/2003 r INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS HOURS REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issue .. 6 Zoned Area Permit NoM im:3 i AGREEMENT • In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector an, IMME IATELY1BECOME NUL AND VOID. �,ega1 Descript' This Card Must Be Posted So It is Plainly Visible From The Street,Unti1 Final Inspection. (INSPECTION RECORD r Footing Foundation Underground Plumbing • Insulation Rough Plumbing Drywall Chimney & Vent Electric Final (by State Inspector) Gas Piping Final / 2_, —,c? -o3 _• Electric Rough (By State Inspector) Septic Final Framing (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED WHETHER INTERIOR OR EXTERIOR, AND APPROVED BEFORE COVERING - UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APP ' OVEDDO NOT DESTROY THIS.CARD Date :'It' PLACED OUTS( E - COVER WITH CLEAR PLASTIC