HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-10-15-3931
Aspen Signature Homes, LLC
Ironbridge PUD Lot 289
1291 River Bend Way
GWS, Colorado
1) SEE PLAN ATTACHMENTS FOR BUILDING REQUIREMENTS.
2) ALL WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC)
AND THE MANUFACTURERS INSTALLATION SPECIFICATIONS.
3) GEOTECHNICAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF COMPACTED
STRUCTURAL FILL; 1000 PSF. PROVIDE ENGINEER SEALED APPROVAL REPORT AT
UNDERGROUND PLUMBING INSPECTION.
4) STRUCTURAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF REINFORCEMENT BARS,
HOLD-DOWNS, AND TENDON INSTALLATION. PROVIDE ENGINEER SEALED APPROVAL
REPORT AT UNDERGROUND PLUMBING INSPECTION.
5) STRUCTURAL ENGINEER SHALL FIELD VERIFY MEASURING OF POST TENSIONED SLAB
CONSTRUCTION. PROVIDE ENGINEER SEALED APPROVAL REPORT PRIOR TO FRAMING
INSPECTION.
6) ENGINEERED ROOF TRUSS SHOP DRAWINGS REQUIRED AT FRAME INSPECTION, 40 PSF.
7) ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED FOR FRAMING INSPECTION.
8) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION.