Loading...
HomeMy WebLinkAboutMetal Building Insulation SpecsJ)ivercoie m i n a t i o n Submittal Date 09/01/2015 Submitter Steve Wardlaw Project Bethel Party Rentals Submitted to Bruce Barth silvercote.com Metal Building Insulation Q Energy Saver FP Insulation System Designed for metal buildings, the Energy Saver FP insulation and fall prevention system provides an efficient state-of-the-art way to insulate and create leading edge fall prevention compliant with OSHA standards when installed by certified installers. This product has been tested and complies with: • ASTM C665, Type I • ASTM C167 • Flame Spread <25 • ASTM E84 • ASTM C991 • Smoke Developed <50 • ASTM C553 Single Layer Roof System O R-30 91/2" 0 R-25 8" 0 R-19 6" Double Layer Rood Systems (New construction) O R-43 (R-30 + R-13) 131/2" Q R-40 (R-30 + R-10)121/:" O R-38 (R-28 + R-10) 11" O R-38 (R-25 + R-13) 11" 0 R-38 (R-30 + R-8) 11" 0 R-36 (R-25 + R-11) 111/2" Q R-35 (R-25 + R-10) 11" 0 R-33 (R-25 + R-8)10'/4" O R-32 (R-19 + R13) 10" e R-30 (R-19 + R-11) 91/" Triple Layer Roof Systems (New construction) O R-49 (R-19 + R-19 + R-11)15/" O R-48 (R-19 + R-19 + R-10) 151/2" Q R-46 (R-19 + R-19 + R-8) 141/2" Single Layer Wall Systems Double Layer Wall Systems O R-30 91/" 0 R-25 8" 0 R-43 (R-30 + R-13)13/" Q R-28 8" 0 R-19 6" 0 R-41 (R-28 + R-13) 12" Q R-30 (R19 + R11) 91/2" ❑ Purlin Glide FP Insulation System Designed for metal buildings, the Purlin Glide FP insulation and fall prevention system provides an efficient state-of-the-art way to insulate and create leading edge fall prevention compliant with OSHA standards when installed by certified installers. This product has been tested and complies with: • ASTM C665, Type I • ASTM C991 • Flame Spread <25 • ASTM E84 • ASTM C553 • Smoke Developed <50 • ASTM C167 Single Layer Systems O R-30 91/2" 0 R-20 6" 0 R-13 4" 0 R-10 3" Q R-25 8" 0 R-19 6" 0 R-11 31/2" 0 R-8 24/4" Double Layer Systems O R-32 (R-19 + R-13) 10" 0 R-26 (R-13 + R-13) 8" O R-30 (R-19 + R-11) 91/2" 0 R-23 (R-13 + R-10) 7" 0 R-29 (R-19 + R-10) 9" 0 R-20 (R-10 + R-10) 6" ❑ Unlaced Metal Building insulation An unfaced fiberglass blanket designed to be used as a backfill material in a variety of insulation systems. This product has been tested and complies with: •ASTM C665 • ASTM C 991 • ASTM E84 O R-30 91/2" O R-28 8" Q R-25 8" • Flame Spread <2 • Smoke Developed <50 Q R-21 63/4" 0 R-13 4" 0 R-10 3" O R-20 6" 0 R-12 31/2" 0 R-8 26/4" 0 R-19 6" 0 R-11 3/" Faced Metal Building insulation A faced fiberglass blanket used in metal buildings. It is usually installed between structural steel and sheeting. This product delivers guaranteed recovered R -value prior to installation. For warranty details visit www.guardian-insulation.com. This product has been tested and complies with: • ASTM C665 • ASTM E84 • Flame Spread <25 • ASTM C991 • Smoke Developed <50 Q R-30 91/5" O R-28 8" Q R-25 8" Q R-21 64/." O R-20 6" R-19 6" 0 2" Condensation Blanket 0 R-16 5" Q R-13 4" O R-12 31/2" O R-11 31/2" 0 R-10 3" Q R-8 26/4" Fiberglass Insulation Facts Fiberglass insulation is made from mineral substances processed from molten state to an incombustible fibrous form. Facing Facts • Standard residential building insulation facings will bum and should not be left exposed. • Residential insulation vapor retarder facings should always be installed toward the warm -in -winter side of the dwelling. • Vapor retarders must have a rating of 1 perm or less. • Special consideration should be given to facing choices for metal building insulation products in areas that will be exposed to excessive amounts of UV light such as buildings with open walls, large doors that will be open frequently or to buildings that will utilize indirect lighting. Sound Facts • Fiberglass insulation increases the Sound Transmission Class (STC) rating when properly installed in building assemblies. It has been determined that thickness has greater value in sound control than density. • NRC (Noise Reduction Coefficient) data is available for most commonly -used products.