HomeMy WebLinkAboutMetal Building Insulation SpecsJ)ivercoie
m i n a t i o n
Submittal Date 09/01/2015
Submitter Steve Wardlaw
Project Bethel Party Rentals
Submitted to Bruce Barth
silvercote.com
Metal Building Insulation
Q Energy Saver FP Insulation System
Designed for metal buildings, the Energy Saver FP insulation and
fall prevention system provides an efficient state-of-the-art way to
insulate and create leading edge fall prevention compliant with
OSHA standards when installed by certified installers. This product
has been tested and complies with:
• ASTM C665, Type I • ASTM C167 • Flame Spread <25
• ASTM E84 • ASTM C991 • Smoke Developed <50
• ASTM C553
Single Layer Roof System
O R-30 91/2" 0 R-25 8" 0 R-19 6"
Double Layer Rood Systems (New construction)
O R-43 (R-30 + R-13) 131/2"
Q R-40 (R-30 + R-10)121/:"
O R-38 (R-28 + R-10) 11"
O R-38 (R-25 + R-13) 11"
0 R-38 (R-30 + R-8) 11"
0 R-36 (R-25 + R-11) 111/2"
Q R-35 (R-25 + R-10) 11"
0 R-33 (R-25 + R-8)10'/4"
O R-32 (R-19 + R13) 10"
e R-30 (R-19 + R-11) 91/"
Triple Layer Roof Systems (New construction)
O R-49 (R-19 + R-19 + R-11)15/"
O R-48 (R-19 + R-19 + R-10) 151/2"
Q R-46 (R-19 + R-19 + R-8) 141/2"
Single Layer Wall Systems Double Layer Wall Systems
O R-30 91/" 0 R-25 8" 0 R-43 (R-30 + R-13)13/"
Q R-28 8" 0 R-19 6" 0 R-41 (R-28 + R-13) 12"
Q R-30 (R19 + R11) 91/2"
❑ Purlin Glide FP Insulation System
Designed for metal buildings, the Purlin Glide FP insulation and
fall prevention system provides an efficient state-of-the-art way
to insulate and create leading edge fall prevention compliant with
OSHA standards when installed by certified installers. This product
has been tested and complies with:
• ASTM C665, Type I • ASTM C991 • Flame Spread <25
• ASTM E84 • ASTM C553 • Smoke Developed <50
• ASTM C167
Single Layer Systems
O R-30 91/2" 0 R-20 6" 0 R-13 4" 0 R-10 3"
Q R-25 8" 0 R-19 6" 0 R-11 31/2" 0 R-8 24/4"
Double Layer Systems
O R-32 (R-19 + R-13) 10" 0 R-26 (R-13 + R-13) 8"
O R-30 (R-19 + R-11) 91/2" 0 R-23 (R-13 + R-10) 7"
0 R-29 (R-19 + R-10) 9" 0 R-20 (R-10 + R-10) 6"
❑ Unlaced Metal Building insulation
An unfaced fiberglass blanket designed to be used as a backfill
material in a variety of insulation systems. This product has been
tested and complies with:
•ASTM C665 • ASTM C 991
• ASTM E84
O R-30 91/2"
O R-28 8"
Q R-25 8"
• Flame Spread <2
• Smoke Developed <50
Q R-21 63/4" 0 R-13 4" 0 R-10 3"
O R-20 6" 0 R-12 31/2" 0 R-8 26/4"
0 R-19 6" 0 R-11 3/"
Faced Metal Building insulation
A faced fiberglass blanket used in metal buildings. It is usually
installed between structural steel and sheeting. This product delivers
guaranteed recovered R -value prior to installation. For warranty
details visit www.guardian-insulation.com. This product has been
tested and complies with:
• ASTM C665 • ASTM E84 • Flame Spread <25
• ASTM C991 • Smoke Developed <50
Q R-30 91/5"
O R-28 8"
Q R-25 8"
Q R-21 64/."
O R-20 6"
R-19 6"
0 2" Condensation Blanket
0 R-16 5"
Q R-13 4"
O R-12 31/2"
O R-11 31/2"
0 R-10 3"
Q R-8 26/4"
Fiberglass Insulation Facts
Fiberglass insulation is made from mineral substances processed
from molten state to an incombustible fibrous form.
Facing Facts
• Standard residential building insulation facings will bum and
should not be left exposed.
• Residential insulation vapor retarder facings should always
be installed toward the warm -in -winter side of the dwelling.
• Vapor retarders must have a rating of 1 perm or less.
• Special consideration should be given to facing choices
for metal building insulation products in areas that will be
exposed to excessive amounts of UV light such as buildings
with open walls, large doors that will be open frequently or to
buildings that will utilize indirect lighting.
Sound Facts
• Fiberglass insulation increases the Sound Transmission
Class (STC) rating when properly installed in building
assemblies. It has been determined that thickness has
greater value in sound control than density.
• NRC (Noise Reduction Coefficient) data is available for most
commonly -used products.