HomeMy WebLinkAboutIndustrial Inspection Services, Special Inspector's Final Report 08.18.2015INDUSTRIAL INSPECTION
SERVICES
Special Inspector's Final Report
JOB NAME Bethel Party Rentals - Bldg B
ADDRESS: 5447 County Road 154 B, GWS
BUILDING TYPE Commercial
FINAL INSPECTION DATE 6-12-15
PERMIT #: BLCO-11-14-3459
GENERAL CONTRACTOR: Bethel Party Rentals
WALL TYPE: Metal Building / Steel stud framed
DESCRIPTION OF INSPECTION WORK PERFORMED: Special inspection for erection and high-strength bolt tensioning
of Pre-engineered metal buliding (Rhino Fabrication) and field welding of structural steel mezzanine / office
steel (beams and columns) as well as miscellaneous connection tabs as required by the 2009 / 2012 IBC,
structural engineer and local building jurisdiction.
LOCATION IN STRUCTURE: Special inspection provided during installation / field erection of pre-engineered metal
buliding components foundation through roof as detailed and approved by Dale Kaup (structural engineer).
REMARKS FOR STRUCTURAL STEEL: Witness pre -tensioning of A325 high-strength bolted steel -to -steel connections
as well as miscellaneous field welding at relocated connection plates as detailed by Dale Kaup (structural
engineer / design professional of record).
All shop welding and fabrication performed by Rhino Builders (AISC approved fabricator) and miscellaneous field
welding performed by certified welder (certs kept on file). Any weld discontinuities were corrected in inspector's
presence and re -welded In accordance with AWS D1.1/ AISC specifications. No problems noted. MW
certifications for steel elements reviewed and kept on file by fabricator.
REMARKS GENERAL Special Inspection on this project was performed per the special inspection requirements
adopted from the 2009 / 2012 IBC by the Garfield County Building Department as part of the approved pian.
ALL WORK REFERENCED ABOVE WITNESSED BY INDUSTRIAL INSPECTION SERVICES PERSONNEL, PERFORMED FROM
JUNE ONE THROUGH TWELVE, TWO THOUSAND AND FIFTEEN, WAS SATISF
APPROVED PLANS, THE 2009 / 2012 INTERNATIONAL BUILDING COD
AND THE AISC MANUAL OF STEEL CONSTRU .. N (9n EDITION). TH
AOF THE STRUCT RE WHICH SPECIAL IN N WAS • ' ESCRIB
Special le dor el Record:
Date:
TORILY COMPLETED AND CONFORMS TO THE
THE ADOPTED PROVISIONS OF THE AWS D1.1
ENT APPLIE ' DIRECTLY TO THOSE PORTIONS
T OF THE AP ;It VED PLANS.
/ I/ . R
tv +I 4
J�,;iiT
ID Number: