HomeMy WebLinkAboutElectrical Permit InfoTo: Admin
Subject: Inspection Report for Permit: 782842
[gJ COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, Colorado 80202
Automatic email - Do not reply to this email.
Permit #:
Permit
Holder:
Site:
Owner:
Status:
Inspection Report
782842
CLINT HOSTETTLER
PO BOX 867 RIFLE 816500867
Phone: (970) 625-5192 Fax: (970) 625-1977
Email: ADM IN@WALKER-ELECTRIC.BIZ
288 S Meadow Dr Rifle County: Garfield
West
West
ACCEPTED
Inspection Type: Rough In
Constuction Type: NEW
Date Inspected: 31-JUL-15
Phone: (970) 625-5192
Trim Permit: N
Building Type: RESIDENTIAL
Inspector: Norman Feck 303-869-3442
Corrections: 1) Missing nail plate near east bath 2) Missing receptale under study room? TV receptacle.
Receptacle outlet installed is less than 5 1/2' elevation but will be covered by a TV.
Comments: Partial Rough Inspection 1) Temporary heat meter release ok 2) Ok to cover walls and ceiling
everywhere other than correction item areas 3) Marking this as a comment instead of a correctic
but could probably cite 110.2 or 110.27B - Three north exterior cans are same depth as wood
member they're attached to and should be protected from nails roofing or re -roofing by 1116"
steel plate or swapping with shallower cans that clear deck by 1 112" (similar to 300.4E or
410.1017). I'll make up my mind if it's a violation or not. It's the right call. In the past I discusses
it with the GCs on site who took care of it.
NOTICE: This email message is for the sole use of the intended recipient(s) and may contain
confidential and privileged information. Any unauthorized review, use, disclosure or distribution
is prohibited. If you are not the intended recipient, please contact the sender by reply email and
destroy all copies of the original message including attachments and any other method of
retention.
Jim Wilson
From: Kelly West [titanfieldservice@gmail.coml
Sent: Monday, August 03, 2015 9:57 AM
To: Jim Wilson
Subject: Fwd: Inspection Report for Permit: 782842
Good Morning Mr Wilson
Here is the State Electrical Inspection you asked for from Walker Electric. Clint said he would send someone
out this morning to look at the issues.
Thank you
Kelly West
Sent from my iPhone
Begin forwarded message:
From: "West, MaIinda" <mwest@2rhd.or
Date: August 3, 2015 at 8:45:27 AM MDT
To: "titanfieldservice0a gmail.com" <titanfie Idservice@gmail.com>
Subject: FW: Inspection Report for Permit: 782842
From: Clint Hostettler [mailto:clintCgwalker_ele tic,biz]
Sent: Monday, August 03, 2015 8:27 AM
To: West, Malinda
Subject: FW: Inspection Report for Permit: 782842
I told Kelley I would send you this so he can pass on to County inspector.
Thanks
Clint Hostettler
TValker Electtzc, Ittc.
PO Box 867
Ride, CO 81650
970.625-5192 o
910-625-1977 f
From: dora electrical board@state.co.us [mailto:dora electrical board-ii-state.co_us]
Sent: Saturday, August 01, 2015 12:05 AM